Document VGyYmozk6dgbJYkOwY3ggeKM8
UNITED STATES ENVIRONMENTAL PROTECTION AGENCY
SUBJECT:
PCS Inspection, Monsanto Krunmrlch Plant, Sauget, ITHnols
_A__ ,,.v on B76 DATE:
PROM:
Chief, Air Surveillance Branch, Surveillance and Analysis Division
TO: Karl Bremer, Member, Lake Michigan Toxic Substances Comnlttee
A preliminary survey was made of the above Installation to Identify and sample point sources of potential PCB emissions to the atmosphere.
The sampling and analysis were carried out at this source to furnish Information to arrive at a further decision that may require and Intensive
testing program to quantify the PCB emissions. The sample analysis revealed the following:
SAMPLING LOCATIONMO. OF SAMPLES
PCB CONCENTRATION uq/H3
Steam Ejector - Ground Level, Site #1
2
* 3A - 27.5 38 - 33.9
Steam Ejector - Top Level, Site *2
2
3A - N.A. 3B - N.A.
Calculated Storage Tank Emissions
Virgin Product Product Loading and Waste Storage
59,7 kg/year 0.02 kg/year
Monsanto has performed a stack test at the Sauget location quantifying the PCB amissions to the atmosphere. Stack-sampling and other reports
describing process and sampling methodology used at this site are attached.
* 3A - Right Side of sampling train - 3B - Left Side
CORRECTED COPY M n ins* no,. *-n>
MGNS 094828
2'
Emissions:
Kg/yr. 460,000 x .0283 x 1.41 x 1 kg 104 wg
Kg/yr. - 0.0184
Esilsslons from handling of Masts aroclors:
Total waste material recalved Into p)ant..as. reported by Monsanto for?nos. of 1975 r I>431,000 lbs. Assume that all this natVTaTTs received and stored at 70*F and that It displaced an equal volume of tank headspace gas at 70*F.
Volume of grodoct - 1.431.000 lbs. x
,, 3.785 m.r
xlbJiUers. . %7, *3
The concentration would be the same as In the loading operation that Is 1.41 mg/M3.
Emissions: Kg/yr. 471 m3 x 1.4 ng/M3 X I ta 10* mg
Kg/yr. - .00066
HONS 0948^9
Clarence Buckley of Monsanto estimated that storage and loading operations at the plant Mould displace the following volume of
1. Storage tanks 635,000 ft3
2. Loading
460,000 ft3
Calculation of emissions:
From Fig. 2.2 from the Draft Mitre report the vapor pressure of Aroclor 1242 Is 0.3 no Hg at 100*C and 10-4 at 21*C. The aroclors are stored at 100'C. It may be assumed that the temp. In the tanks being loaded would be approximately 70*F (21*C).
From Dolton's law of partial pressure:
Bx Px where Bx proportion by volume of a gas component P mix.
Px partial pressure of gas component and P mix. absolute pressure of gas mixture.
Bx 0.3 .039 or 390 ppm 75ff 1
To change ppm to mg/M3 use the following formula:
mg/M3 ppm x
mol, wt.
molecular volume
molecular volume 30.62 ltters/mol. at 100*C
mg/M3 390 x^261^ 3324
Emissions from storage tanks: Emissions kg/year Vol. of gas displaced/year x concentration
Of PCB
Kg/yr - 635000 ft3 x .0263 M3 x 3324 x 1 ka 7t3 10b mg
Kg/year 59.7
Emissions from loading operations:
Bx Px - 10~* 1.3 x 10-7 or .13 ppm Tnsnr. ~m
mg/M3 - .13 x 261 - 1.41 mg/M3 24704
MONS 094tt30
VAPOR PRESSURE (ts s E g ) .
11000/1 WO"1
Source: liutzlngcr, 0., S. Safe, and V. Zitko, "The Chemistry of PCBa," CRC Press, Cleveland, Ohio, 1974. FICURE J.2 . VAPOR PRESSURES OF DIFFERENT AKOCLOR PREPARATIONS
2b
MONS 094831