INTERDEPARTMENTAL. COMMUNICATION
TOx
ALL GYPSUM DIVISION REG I ONA^. MANAGERS
PROM: ^ T. R. Godfrey
SUBJECT: 5/8" FIRESTOP TYPE X
DATE:
December 5, 1969
LOCATION:
LOCATION: Portland
We now have a letter interpretation from Underwriters
Laboratories listing the use of 5/8" Type X Wallboard on all of
our 1-hour and l^-hour rated f1oor/cei1ing assemblies.
This will clear up the confusion as to whether Type X or Type XXX is required, The_ojiLy^.a.$sembHes now still reoui ring..
5/8" Type XXX are the 2-hour ratings (UL Designs $217 and V/2~59)_
Those f1oor/cei1ing assemblies allowing Type X are: Floor and ceiling Designs UL //l 1-hour. //19 1-hour, $13 l?-hour, and the 2-hour beam constructions, UL #254 and #255. Also, of course, continue to sell Type X on all wall assemblies.
This new listing will cover the use of 46 to 54 inch
wide wallboard and 2 foot wide Backer Board. As our sales in volving the 2-hour floor/ceiling assemblies are small, 5/8" Type XXX board shortly will be on a special order basis only, so anticipate the requirements.