Document VGmx0xzV5q0BbYOd7NakkBqYZ

On pages *43-*504 will be found the Catalog Data of 319 man ufacturers whose products are described and illustrated. For the convenience of the user of THE GUIDE 1958 there are eleven main divisions: Air Conditioning......................................................................................#43-#125 Air Conditioning and Heating Piping....................................... # 126-#129 Air System Equipment............................................................. .. #130-#279 Controls and Instruments....................................................................#280-# 311 Expansion Joints...................................................................................#312-# 315 Fittings and Flanges..............................................................................#316-# 320 Floats...........................................................................................................#321 Heating Systems.......................................................................................#322-# 450 Insulation..................................................................................................#451-# 488 Vibration....................................................................................................#489 Publications .,..........................................................................................#490-# 496 On pages 11- 40, under each of the index headings--Air Clean ing Equipment, Fans, Humidifiers, Ventilators, etc., will be found a list of manufacturers of any desired products, fully cross-indexed, and the page numbers in the Catalog Data Section where the prod ucts are described. By reference to these indices, the manufacturers' names and the page numbers, any item of equipment or materials, and the pro ducer's address, may be located quickly. Air Conditioning Air & Refrigeration Corporation 439 Madison Avenue, New York 22, N. Y. 271 Milton Avenue, S. E., Atlanta, Ga. A\ Representatives in all major cities /u\L Foreign Representative--Rocke International Corp., ( ^ 13 East 40th St., New York 16, N. Y. v" Air Conditioning, Humidifying, Dehumidifying, Cooling, Scrubbing, Air Washing and Purification Apparatus D Air & Refrigeration Corporation specializes in the design and manufacture of indus trial and comfort-conditioning apparatus where maintenance of suitable humidity mid temperature within closely controllable limits is essential. This specialization is based on technical knowledge and ingenuity born of extensive experience in the solution of the more difficult problems of air conditioning. A complete line of air conditioning equipment is available to contractors and owners for all phases of humidifying, dehumidifying, cooling and washing. * Capillary Air Washers provide a superior type humidifying, dehumidifying, air washing, cleaning and cooling unit for central station apparatus. For most purposes the Capillary Washer requires the volume of water at H the pressure used by conventional spray equipment. They are available with factory insulated casings and tank for central station applica tions. For complete data, see Capillary Bulletin. * Capillary Unit Conditioners are factory insulated and as sembled, ready for use. They include fan, motor, drive, heating I coils. Capillary Cells with suitable sprays, spray pump and ] mixing dampers. Units are designed for floor mounting or for ceiling suspension, and can be arranged for the reception of cooling coils, if required. Complete description and engineering Factory Insulated Class I Capillary Air Washer data will be found in Capillary Unit Bulletin. Spray Type Air Washers for washing, humidifying and dehumidifying air are all basically the same. A & R Spray Washers include special features of design developed to insure more efficient and dependable operation, lower maintenance costs, and, in many cases, lower installation costs. Such features relate especially to eliminators, collecting tanks, flooded baffles, nozzle arrangement, etc. Spray Washers can be supplied with factory insulated casings and tank for central station applications. For details, see Air Washer Bulletin. Sprayed Coll Dehumldlfiers for year-round treatment of air are complete with cooling coils, sprays, circulating pump and glass mat eliminators. Sprayed coil denumidiners are factory insulated and complete, ready for assembly in the field, special features in design insure continuous washing and cleaning of finned surfaces and easy accessibility to all parts. For engineering information and detailed descrip tion, see Sprayed Coil Bulletin. , A * R Insulated Panels consist of insulation between metal sheet on one side and nard liber board on the other, the three laminated and cemented together. This unique panel design includes the structural frame to form units which require only oouing together to make enclosures of any required shape for plenum chambers and tni'/fiTv PurP3?8- Panels are available iD widths from 3 in. to 48 in., and in lengths R,;; ,,,eir use insures tremendous economies in field labor. For details, see Panel n . "'rile for catalog and engineering data. Registered Trade Mark T'/g'SS AirWmhtr rectory Undated 43 Factory Insulated Plenum Chamber