Document VGmNR0Vr1XbZk2v7o12Znr1Q4

PPG INDUSTRIES, INC. INDUSTRIES i INDUSTRIAL CHEMICAL DIVISION P. 0. BOX 10Q0 December 19, 1983 LAKE CHARLES, LA. 70602 Mr. Gus Von Bodungen Department of Natural Resources Air Quality Division Office of Environmental Affairs P.0. Box 44066, Capitol Station Baton Rouge, LA 70804 Re: Incinerators No. 1, 2, & 3 Performance Test Dear Mr. Von Bodungen: In accordance with the Louisiana Emissions Standards for Hazardous Air Pollutants regulation Section 76.18 enclosed is the final report for the performance test of the VCM continuous monitoring system on Incin erators No. 1, 2, & 3, gathered on December 10, 1983 through December 14, 1983. Incinerator No. 4, which is temporarily out-of-service, was not tested due to problems with the in-stack analyzer. Per the verbal approval granted by your office. No. 4 Incinerator will be tested during the next period in which the Incinerator is operational. Itemized below is a table of contents for the enclosed report on the performance test. If you should have any questions concerning this report, please-call me at 318/491-4576. Respectfully /bf end. cc: Mr. Joe Withers Philip S. Trew Environmental Control Specialist bcc: R. J. Samel son J. Fike E. J. Tullier B. Salter C. Lona File #106.5.03 (letter only) (letter only) (letter only) SL 047835 TABLE OF CONTENTS Performance Specifications and Results Description of System 2hr & 24hr Zero and Calibration Drift Relative Accuracy Test Calibration Error Auto Zero Test Response Test Gas Cylinder Certification Page No. 1 2-4 (Table I) 5-7 (Table II) 8 (Table III) 9 (Table IV) 10 (Table V) 11-14 (Table VI) 15-17 SL 047836 PERFORMANCE SPECIFICATIONS AND RESULTS PARAMETER 1. Conditioning Period 2. Operational Test Period 3. Calibration Error 4. Response Time 5. Calibration Drift (2-hour) 6. Calibration Drift (24-hour) 7. Resolution: a. Data Recorder Chart b. Data Logger Printer 8. Relative Accuracy SPECIFICATION >96 hours >96 hours <5% of each (midrange & Tiigh-range only) calibration gas valve <10 minutes <0.5ppm VC <1.0ppm VC <0.05% of fullscale 0.1ppm VC _<0.5ppm VC RESULTS >96 hours 96 hours 0.7% of span gas 1.5% of midrange gas 5i minutes (ea) 0.045ppm 0.15ppm <0.05% of full scale <0.1ppm VC 0.05ppm VC Pg. 1 SL 047837 DESCRIPTION OF SYSTEM G. C. The central portion of the monitoring system is an Areas process gas chromatograph Model 905. The G. C. is equipt with an FID and a column system as outlined in Figure 2. The recorder used in the system was manufactured by Linear Instruments Corporation and is a Model 142 with multiple ranges. Pg. 2 SL 047838 16/W& 5cAe-/?f&r7 VC/W Pa. 4 SL 047840 TABLE I 3*U Iff 1*4. Itffn Oiu Itidtnf Spin Spin (>) (tSpAA-Alcfft) OCM J LOO 1 1 10:00 10:06 12/10 .01 -.07 6.25 7 12:06 12:12 12/10 .03 .02 6.20 -.05 .05 -.01 3 14:02 14:14 12/10 .05 -.02 6.33 -113 .11 < 16:03 16:14 12/10 .00 -.05 6.32 -.01 .04 i 18:00 18:16 12/10 .06 .06 6.32 0 -.06 i 19:59 20:10 12/10 .05 -.01 6,29 7 08:00 08:39 12/11 .00 6.17 -.03 - .12 -.02 ` -.07 8 10:58 11:10 12/11 .00 0 6U0 -.07 -.07 13:04 13:10 12/11 .03 .01 _6.11 .01 0 to 15j.05_15;11 12/11_,00. -.01 6.06 n 17:_Q1 17:06 12/11 .01 .01 6.01 19:07 19:13 12/11 .00 .-.or' 6.10 -..05 -.05 .09 -.04 -.06 .1 n 08:00 08:26 12/12 .03 .03- _6.24 .14 .11 t 10:09 10:21 12/12 .00 -.03 _6.24 0 .03 if itr1o 2:27* 12:38 12/12 if-MA itro Drift* nfiu .01 CT .01 6.21 -.03 -.04 CiltbratiftK ftflii * LMttft iDKiHinn^ ti tsiiVio:r- Jrvtasppin *Abiolut Vaiwt, (J(J4 041 .U4bppm MfVPt.ia 3. Iir* CtUbrttlM Orlft (1 Hmf). 3ate and Time Zero Reading Zero Drift (aZero) . Span Reading (After zero adjustment) 1LT*- Calibration Drift (aSpan) 12/10 08:15 -.08 12/11 08:00 .00 12/12 08:00 .03 12/13 08;-15 .03 12/14 08:05 .02 -.08 .03 .00 -*;01 10.59 10.65 10.52 10.46 10.54 .06 -.13 -;06 ' .04 . Jcro Drift [Mean Zero Drift* .015 .0986ppm . 4 C.I. (Zero) .0836 ] Calibration Drift - [Kean Span Drift* .007 - ilMnpro ,, + C.I. (Span) . 14 * Absolute value 1 Figure 3*2. Zero and Calibration Drift (Z<-hour) ZERO AND CALIBRATION DRIFT (TWO-HOUR) II 1 o XI XjM, ro *oo *oo Xi .02 .02 -:05 .06 -.01 -.05 .00 -.01 -.01 .01 -.01 .03 -.03 .01 ZXi o i A Zero Xi2 .0049 .0004 .0004 .0025 .0036 .0001 .0025 0 .0001 .0001 .0001 .0001 .0009 .0009 .0001 = .0167 A Span xi xi2 -.02 .0004 -.05 .0025 .13 .0169 -.01 .0001 .0 -.03 .0009 -.12 .0144 -.07 .0049 .01 .0001 -.05 .0025 -.05 .0025 .09 .0081 .14 .0196 .0 -.03 .0009 = -.06 EXi2 = .0783 Zero Drift = | Mean Zero Drift | + C.l.(Zero) 1 IT (-.07) + -/T5(0.0167) - (-.07)' .005 + 0.0189 = 0.0239 Pg. 6 SL 047842 Calibration Drift Mean Span Drift | + C.l.(Span) 1 2.145 ^/l5(.0783r^(-.06)2 15 (-.06) + T57IT 0.004 0.045 + 0.041 Pg. 6a SL 047843 ZERO AND CALIBRATION DRIFT (TWENTY-FOUR HOUR) A Zero Xi Xi2 .08 .0064 .03 .0009 .0 .0 -.01 = -.06 .0001 EXi2 = 0.0074 A Span Xi Xi2 .06 .0036 -.13 .0169 .06 .0036 .04 EXi = 0.03 .0016 EXi2 = .0257 Zero Drift = | Mean Zero Drift | + C.l.(Zero) 1 (-.06) + ^4(0.0074) - (-.06)' 0.015 0.0986 + 0.0836 Calibration Drift = Mean Span Drift | + C.l.(Span) {(0.03) + -yj4(oTo257) -- ("-03)1 0.0075 0.154 + 0.1466 Pg. 7 SL 04784^ TABLE II RELATIVE ACCURACY TEST xi 6.27 6.25 6.20 6.33 6.32 6.32 6.29 6.17 6.10 6.11 6.06 6.01 6.10 6.24 6.24 6.21 EXi = 99.22ppm xi2 39.31 39.06 38.44 40.07 39.94 39.94 39.56 38.07 37.21 37.33 36.72 36.12 37.21 38.94 38.94 0 38.56 ZXr - 615^2 Relative Accuracy - Mean Reading + C.l. (Reading) = ^ (99.22) + 16(615.42) - (9922)2 = 6.2 + 0.05 = 6.25ppm (for 6.3ppm standard) Pg. 8 SL 047845 TABLE III CALIBRATION ERROR ^Calibration Error (2 hr) - vc^onc^ln stlnda^d hr) X 100 = 0-^53X 100 = 0.71% %Cal1bration Error (24 hr) = Calibration Drift (24 hr) X 100 VC cone, in standard __ -0--.-1--5^4 x---1--0-0= 1.47% Pg. 9 SL 047846 - TABLE IV Date of.Test: TABLE V FIGURE 3-3 RESPONSE Incinerators No. 1 & .2 (Stack No. 1) 17/1?/ft3 Span Gas Concentration: 10.5 PPm Response: A. Upscale > 1 2. 1 cycles 10.5ppm cycles 10.57ppnf 3. 1 cycles 10.53ppm Average i cycles X cycle time: 330 - Average upscale response time; 330 sec. se c/cycl< i B. Downscale 1. __ 2. __ 1 1 cycles cycles O.lppm 0.06ppm 3. i cycles 0.19ppm Average 1cycles X cycle time: 330 sec/cycle = Average Downscale response time: " 330 sec. Gian ge gases at the same time the GC injects the sample. Pq. 11 SL 047848 sL 0^78*9 Date of.Test: TABLE V FIGURE 3-3 RESPONSE Incinerator No. 3 (Stack No. 2) 12/13/83 Span Gas Concentration: 10.5 ppm Response: A. Upscale '' _1 2. 1 _____ cXc,es 10.43ppm _____cycles 10.44ppm' 3. 1 _____cycles 10.41ppm Average 1_______ cycles X cycle time; = Average upscale response time; 330 330 sec. sec/cycle B. Downscale 1. __ 2. __ 1 _ cycles __ cycles .OOppm ,05ppm 3. 1 __ cycles .51ppm Average J____ _ cycles X cycle time; 330________ sec/cycle = Average Downscale response time; 330 sec. Change gases at the same time the GC injects the sample. pg. 13 SI* 047850 I I SL 047851 TABLE VI LIQUID AIR INC. GAS MIXTURES Cylinder No. SPAN GAS T-125687 MIDRANGE GAS ------2UU93------- Composition: Vinyl Chloride Nitrogen 10.5ppm Balance 6.3ppm Balance NBS Std. No. CC-36469 CC-36452 CC-36416 CC-36469 CC-36452 CC-36416 Cylinder Exp. Date 12/8/85 12/8/85 Pq. 15 SL 047852 I AIR LAB A division of LIQUID AIR INC. P.O.Box 1020 ' Lake Charles. Louisiana 70602 ANALYSIS CERTIFICATION VALVE 350 Customer PPG CYLINDER NO._____ P. O. No. DATE COMPONENT Requested, "I. VINYL CHLORIDE NITROGEN - ........... 5 PPM t t [BALANCE .;-r ' .* x i* J i . .. Dec. 8/1983 ANALYSIS PPM `i J, > f NBS STO #00-36469 CC-36452` CC-36416 ' . i , < Make Date 12/8/83 , Exp. Date 12/8/85 In general, the accuracy of Analysis is + 1% of Component Value. ______ GvMx Cylinder Pressure 200Q# * Analysis is Percent by Volume Unless Otherwise Specified. SL 047853 I AIR LAB A division f 1 LIQUID AIR INC. P. O. Box 1020 * Lake Charles, Louisiana 70602 ANALYSIS CERTIFICATION VALVE,_____3_5_0_ Customer PPG Oirior Data 12/8/83 CYLINDER NO. Shipped 12/8/83 I. T P. O. No. - i.D! No. DATE Dec* 8, *1983 COMPONENT REQUESTED ANALYSIS* VINYL CHLORIDE NITROGEN 10 PPM BALANCE \G, 5 PPM NBS SID #OC-36469 OC-36452 OC-36416 * Make Dale 12/8/83 Exp. Date 12/8/85 Cylinder Pressure In general, the accuracy of Analysis is . 1% of Component Value: ^ _______ ____________________________ ' ANALYST 2000# * Analysis is Percent by Volume Unless Otherwise Specified. 17 SL 047854