Document VGaX40rgOao64Gn9ry1r1Dywo

CertairileedH Technical Bulletin December 16, 1980 TO: All P&PG Sales and Marketing Personnel District Sales Managers Territory Managers Sales Engineers A/C Customer Service Managers A/C Quality Control Managers FR: James R. Alley Q a - ^s<' v J * or V' SUBJECT: IAPM0 - RECOMMENDATION OF PLUMBING RESEARCH COMMITTEE ASBESTOS-CEMENT FLUID TITE PRESSURE PIPE 3", 4", 6", 8", 10" & 12" Attached is a copy of the Research Committee Approval. Product listing will appear in the Directory of Research Recommendations. Approval covers classes 150 and 200 of pressure pipe in the subject sizes. If you require additional copies, please contact the A/C Marketing Specification Engineer at Valley Forge. BULLETIN: 37 DATE: 12/16/80 CTD000082 INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS A NON-PSOfIT CORPORATION RECOMMENDATION OF THE PLUMBING RESEARCH COMMITTEE The product described herein has been reviewed, tested and recommended for acceptance by the Re search Committee of the International Association of Plumbing and Mechanical Officials as meeting the requirements of the UNIFORM PLUMBING CODE. This recommendation is subject to the conditions set forth in the characteristics below and is not to be construed as assurance or guarantee by the Association of product acceptance by local jurisdiction or authorities using the UNIFORM PLUMBING CODE or other wise affiliated with the Association. , September 1980 Accepted September 1981 Void after______________________ PRODUCT: Asbestos Cement Pipe & Fittings (Water) FILE NO. 1449 APPLICANT: Certain-Teed Products Corp. Pipe and Plastics Group P.O.Box 860 Valley Forge, PA 19482 MODEL: Fluid Tite Pressure Pipe: 3", 4", 6", 8", 10", 12" IDENTIFICATION: Manufacturer's name or trademark, and pipe size, class and UPC logo on pipe and fittings. CHARACTERISTICS: Class 150 and 200 asbestos cement pipe and fittings for use in water pressure systems, when installed in accordance with the manufacturer's installation guide. This rcommendation it lor the period indicated herein ond is void oHer dote shown above. Any change in mAi. design without having first obtained the approval of the Research Committee or evidence of inferior work follow on equitable service policy may be deemed as sufficient cause for revocation of this recommendati reference to this form for advertising purposes may be mode only by specific written permission of Inte Plumbing ond Mechanical Offiaalrljiis authonies the use of the UPC shield or^producls covered by this CHAMMAN MHARCK COMMITS| (UK , Sponsor of Uniform Plumbing Code, Uniform Swimming Pdoi Cods, Uniform Solsr Energy Cods tnd Uniform Mochsnlcsl Cods