Document VGD9yN4nmrDVo050YqeVDagzK
MILBS O. COLWBLL, M.D PITTSBURGH OPTICS
(.
m. A. M. HUNT PITTSBURGH OFFICE - 30
September 8, 1971
Rat OCCUPATIONAL HEALTH AND SAFETY ACT OP 1970
Thuik you vary nch for sanding tha material to am you racaivad at tha naating of tha Board of Diractora of Allandala Mutual Incuranca Company concerning tha abova notad Act. Tha summaries ara good and I hava placed than in ay fila for futura usa.
You might ba intarastad in Alcoa's praparation to data to naat tha requirements of tha Act. Wa brought all plant managers to Pittsburgh on April 1, 1971 for a seminar concarning tha Mtning of tha Act and thair rasponsibilitias undar sum. Sinca then wa hald similar saminars in Pittsburgh for tha Allied.Products group and ona at ARL for thair kay parsonnal. Ms hava assistad tha plants in raorganlsing thair staff rasponsibilitias ra environmental activities where necessary. Me hava had tha Pittsburgh Organisation and Compensation people visit with our staff a"* also visit two plants to assist us in present reorgani sation and in tha development of futura staffing requirements.
In spite of all of tha abova preparation, I'm certain we will hava som difficult days ahead as tha Federal Occupational Safety and Health Act of 1970 is implemented. However, I am confidant wa can respond in a professional marnwr to any problems presented to our staff.
MILES O. COLWBLL, M.D.
MOCtdb
P.Ss
After I finished this note to you, I read tha attached cover latter from T.B.Bonney to our plants--I thought you might ba interested in tha type support wa provide our
plant parsonnal.
Att
M.O.C.
-CCA
411682 0099
FROM
THCMAS B. BONNEY PITTSBURGH OFFICE
TO INDUSTRIAL HYGIENISTS
September 3, 1971
RE: OCCUPATIONAL SAFETY AND HEALTH STANDARDS ________
Of the Occupational Safety and Health Standards published in the Federal Register on May 29, those of primary interest to the industrial hygienist are contained in Subparts G, H, I and Q. All of you must become intimately acquainted with the provisions in these subparts that apply directly to operations at your location.
In looking over these subparts, we noted several items that could stand some clarification. Other important, ones were clear enough, but their brevity might cause them to be overlooked. The follow ing comments concern these types of entries. They are offered in hope that they may be of assistance to you.
SUBPART G - OCCUPATIONAL HEALTH AND ENVIRONMENTAL CONTROL
Sec. 1910.93 Air Contaminants. This section states that exposures above the concentrations listed in the ACGIH list of Threshold Limit Values for 1970 shall be avoided. We interpret the listed concentrations, except those designated with a "C" (Ceiling Value) to mean time-weighted averages for any 8-hour workday of a 40-hour workweek. This interpretation is clearly stated by the governmental hygienists from whomt. the OSHA Standards were taken, in the Preface of the Threshold Limit Values which was omitted in Part 1910. Even Table G-2, which includes values taken from ANSI Standards, indicates that time-weighted averages are intended. Amendments to the first group of standards subsequently published by the Department of Labor in the August 13 Federal Register eliminate the ambiguity and conform with the above interpretation.
It is important that when an air sample collected in a working area shows a value above the TLV, a sufficient number vof additional samples must be taken so that it can be determined if the timeweighted average is above or below the TLV. Care must .be taken with record keeping. Unless otherwise indicated, a single number recorded will be interpreted as the time-weighted average.
When excessive values are recorded, one must note if employees are actually exposed to these concentrations. If so, note if they are wearing personal protective devices. If personal protection is worn, an excessively high contamination level may not constitute a violation.
We would further point out the wearing of personal protective devices does not automatically put one in compliance with Section 1910.93. Paragraph 1910y9^(b):.atatasf.thkf {.'feasible administra tive or engineering controls must' first be determined and implemented in all cases." It is obvious that the Department of
ALCOA
L
411582 0100
Industrial Hygienists September 3, 1971 Page 2
Labor intends that contaminants be controlled at the sources. The test of feasibility of other control methods will determine whether or not personal protective equipment may be used to achieve compliance.
Section 1910.94 Ventilation. Paragraph 1910.94(b)(2J is of special interest in view ofthe large number of grinding, polishing or buffing units throughout the Company. The paragraph states that "Every establishment performing dry grinding, dry polishing, or buffing shall provide suitable hood or enclosures that are connected to exhaust systems."
Paragraph 1910.94(d)(8)(ii) refers to ventilation of open surface tanks. It states that "Recirculation (of exhaust air) shall only be through a device for contaminant removal which will prevent the creation of a health hazard in the room or area to which the air is recirculated." We interpret the necessary degree of air cleaning to be that which reduces the concentration of the contaminant to a level below its Threshold Limit Value. This interpretation applies not only to recirculated air from open surface tank exhausts, but other exhausts as well.
One must always be careful about recirculating exhaust air because state and local authorities may I^ave stricter regulations than those promulgated by the Federal Government. Pennsylvania, for instance, will allow no recirculation without the approval of their Industrial Hygiene Division, and they donft approve many
Section 1910.95 Occupational Noise Exposure. The enclosed booklet, "Guidelines to the bepartment of Labors Occupational Noise Standards," was prepared by the Department of Labor to explain the provisions of the Walsh-Healey Occupational Noise Standard, and to show what is expected of the employer in order that he be in compliance. Because the Walsh-Healey noise standard was included, in toto, in the regulations under the Occupational Safety and Health Act, the contents of the booklet are applicable to all industrial establishments, not only those having government contracts. The booklet offers excellent guidance in carrying out a hearing conservation program.
SUPBART I - PERSONAL PROTECTIVE EQUIPMENT
Sec. 1910.134 Respiratory Protection. The requirements for users of respiratory equipment are quite detailed and specific. Those having responsibilities for respirator protection programs should read this section carefully. Generally, both the Safety Director and the Industrial Hygienist are involved. Among other
*11582 0101
Industrial Hygienists September 3, 1971 Page 3
things, the OSHA regulations require maintenance and care of respirators including inspection for defects, cleaning and disinfecting, repair, and storage.
SUBPART Q -WELDING, CUTTING AND BRAZING Sec. 1910.252 Welding, Cutting and Brazing. Included in this section are the usual ventilation requirements. One unusual requirement is the labeling of all hazardous materials used in these processes (1910.252(f)(l)(v)). Even filler metals must be tagged with a precautionary statement beginning with ''Welding may produce fumes and gases hazardous to health." The responsibility for appropriate labeling should be passed back to your suppliers.
General. As you can realize, the next several months working with OSHA will be a period of learning together. However, if you have any questions about the Act or the Standards under it, please let us know. We'll try to come up with an answer.
TBB:mh Attachment cc: G. H. Farrah, ATC
J. M. Plunkett, ATC V. W. Rieke, Pittsburgh R. H. Watson, Pittsburgh L, V. Cralley, Pittsburgh
411582 0102