Document VG2a6aBQQ40zm9yLMR8y4wxkq

116 Air Conditioning Mutiiil Heating, DtrMt-FM tiuicti E. K. CAMPBELL COMPANY Manchester at 18th Kansas City 26, Mo. Sales and Service Offices in Principal Cities Heavy Duty Warm Air Furnaces Capacities to 8,000,000 btu Builders of Custom Heating'Equipment Since 1910 "Thermidaire'' Design 10 "Thermidflire" Design 40 "Thennidaire" Design 41 "THERMIDAIRE" DESIGN 10 HEAVY DUTY FURN ACES--CUSTOM HEAVY DUTY EQUIPMENT FOR ENGINEERED APPLICATIONS. Typical Problems for which Design 10 Furnaces Offer an Excellent Solution: Need for constant ventilation--To maintain freshness in any structure, particu larly where high occupancy loads occur, modulating face and by-pass zone ar rangements are used to obtain constant air circulation with "Thermidaire" Design 10 Heavy Duty Furnaces. Need for air conditioning--Since most modem structures have either present cooling requirements, or will have at some future date, the large air capacities needed ana the basic distribution system required are readily available in the structure using "Thennklaire" Design 10 Heavy Duty Furnaces. Need for very large capacity equipment--Where large loads exist, the high output capacity available from single units simplifies the solution. "Thermidaire" Design 10 Heavy Duty Furnaces available in standard sizes with output to 8,000,000 Btuh and 145,000 cfm, larger on special request. Need to meet special design requirements--For balancing Btuh vs. cfm component sizing, separate sizing of furnace and blower elements permits "Thermidaire" De sign 10 Heavy Duty Furnaces to meet special requirements for very high or low air volumes, or temperature rises, and to handle unusual jobs, process needs, or exceptional buildings. Need for flexible or special equipment arrangements--Where building di mensions limit outlet or inlet duct arrangements, location of firing front or position of blower relative to air conditioning or furnace components "Thermidaire" Design 10 Heavy Duty Furnaces are excellent due to the extreme flexibility possible in arranging equipment. Need for foil convertibility to any fuel--Where dual fuel equipment is required, or in event of future changes in fuel requirements, (including gas, L. P., oil light or heavy, and solid fuels), "Thermidaire" Design 10 Heavy Duty Furnaces offer com- Slete protection since any of these fuels can be efficiently burned. eed for extra quality equipment--"Thermidaire" Design 10 Heavy Duty Fur naces are the highest quality equipment available, designed for continuous duty and long life on tough jobs and large loads. Only Heavy Duty blower equipment is used. Only highest grade burner and control equipment used. Extra Heavy welded steel construction throughout. Baked enamel exterior finish. Fiberglas insulated casing. Low Internal resistance to flue gases. Operating efficiencies up to 84 percent with resultant fuel economy. Counter-Flow heat transfer. Positive pressure or Drive through principle. Need for special services-- Our half-century of application experience in the specialized field of heavy duty warm air heating is available to assist in arriving at the proper solution to your problem. We recognize that satisfactory solution of the Users problem is the end objective and we back our equipment with competent field service to accomplish this. "THERMIDAIRE" DESIGN 40 HEAVY DUTY FURNACES Standard heavy doty equipment for general heating applications--Available from 250,000 to 2,000.000 Btuh output'in vertical, horizontal, and inverted models--avail able for gas, oil or combinations. Provides convenient compactness, high efficiency, simple installation. Blower, burner, ID fan and controls, mounted, wired and fire tested. Normally shipped assembled. "THERMIDAIRE" DESIGN 41 HEAVY DUTY FURNACES Standard heavy duty equipment for engineered applications--designed for usej_ with face and by-pass, constant ventilation, or air conditioning--requires separate blower--has built in by-pass section--available in same models and fuels as Design -40, in sizes from 250,000 to 3,000,000 Btuh output. Provides convenient compactness, high efficiency, simple installation. Burner, controls and ID fan, mounted, wired and fire tested. Normally shipped assembled. OTHER DESIGNS AND SPECIAL EQUIPMENT AVAILABLE ON REQUEST Air Conditioning 117 1 CHICAGO STEEL FURNACE CO. Home Office & Plant 9326 S. Anthony Ave., Chicago 17, Illinois Engineering Sales Offices from Coast to Coast TUBE AND TtANSFE* BOX ACCESS REgent 1-0280 TWO-PASS ALUMINIZED STEEL EXCHANGE Up Flow and Counter Flow Horizontal Furnaces and Duct Heaters 120,000 to 2,500,000 Btu Output Single and Dual Fuel; Oil and/or Gas 442 SX, RIBBED TEAR DROP CONSTRUCTION, 2-PASS COMBUSTION CHAMBER FOR STRENGTH AND EFFICIENCY Horizontal Furnace Duct Heater Chicago Steel Furnace Co. announces the production of a new line of steel furnaces made of stronger 442 Stainless in capacities to 2H million Btu'a in all popular designs. Chicago's 442 Stainless line supplements the refractory lined series still available. Stainless Steel Unit All models available with either duct flange connections or (optional) with 4-way adjustable diffuser beads and screened intakes. Cuts and features here shown pertain to our stainless steel series of furnaces only. Firing equipment, all fuels, UL and A.G.A. inspected and approved. SPECIFICATIONS STAINLESS STEEL SERIES* COUNTERFLOW HORIZONTAL Outlet 120,000 100,000 200,000 2SO.OQO 300.000 400.000 ' $00,000 000.000 700.000 300.000 000,000 1,000,000 1.250.000 1.600.000 .1.750.000 2 000.000 2.350.000 2.800.000 7.500 8.800 10,000 23.000 35.000 38.000 32.000 8M X 6H SH X SH 8K X 5H SHXW sh x m 88)M4 XXSSHH 8J4-X SH 1QM X m 10M X SH tin x m UK X 7H IW X 7H ilk X> 7M ISM > 13)4 X SH 13)4 X OH HH X OH UT- 130 UT- ISO UT- 200 UT- 250 UT- 300 UT- 400 UT- 500 ut- eoo UT- 700 UT- 800 UT- 800 UT-1000 UT-1250 UT-1600 UT-1750 UT-2000 UT-3350 UT-2500 HT- 120 HT- m HT- 300 HT- 350 HT- 300 HT- 400 HT- 500 HT- S00 HT- 700 HT- 800 HT- 900 HT-1000 HT-12J0 HT-IS00 HT-I7B0 HT-2000 HT-33S0 HT-2500 tll40 DT- 130 DT- ISO DT- 200 DT- 350 DT- 300 DT- 400 DT- 500 DT- 600 DT- 700 DT- 800 DT- 900 DT-1000 DT-1350 DT-1500 DT-1750 DT-2000 DT-32S0 DT-1500 * Specifications sad dimensions subject to change without notice. Contact factory for certified dimensions. Some changes currently being considered. 1000 1380 1380 1750 1750 3040 2040 REFRACTORY LINED SERIES** SPECIFICATIONS COUNTER-FLOW HORIZONTAL DUCT HEATER 130.000 1.600 160.000 2,000 200,000 2.500 250.000 3.300 300.000 3.800 400,000, 5.000 500.000 6,200 600.000 7,600 700.000 8.800 800.000 10.000 900.000 11.300 1,000,000 12.500 1.250.000 15.600 1.500.000 18.600 12.,070500,.000000 23.000 35.000 4 X SH k 4 X 6H H 4 X 6H H 4 X SH H 4 X 5W W 4 X 6H H 4 X 544 H 4 X SH H 4X1)4 M 4 X SH M 4 X 7H H 4 X 7H H 4 X 7H k 4 X 7H H 13H ) 13H > UR- 130 UR- 160 UR- 300 UR- 250 UR- 300 UR- 400 UR- 500 UR- 600 UR- 700 UR- 800 UR- 900 UR-1000 UR-1350 UR-1500 UR-1750 UR-3000 CR- 120 CR- 160 CR- 300 CR- ISO CR- 300 CR- 400 CR- 506 CR- 600 CR- 700 CR- 800 CR- 900 CR-1000 CR-1250 CR-ISOO CR-1750 CR-2000 HR- 130 HR- im HR- 300 HR- 250 HR-300 HR- 400 HR- 600 HR- 600 HR- 700 HR- 800 HR- 900 HR-1000 HR-1250 HR-1500 HR-J750 HR-3000 DR- 130 DR- 100 DR- 300 DR- 250 DR- 300 DR- 400 DR- 500 DR- 600 DR- 700 DR- 800 DR- 900 DR-1000 DR-1230 DR-1500 DR-1750 DR-2000 Over 3,000,000: Contact factory on seeds, custom manufactured. `Draft.Inducer b Optional on Rcdractory-lened Serien. * 8peciorations and dimensions subject to change without p-t!^ Contact factory for certified dimensions. Some changes currently being considered. 3400 3400 4306 4300 4800 6400 6300 7030