Document VG2Kpd6jkRrOYYVx4GmpVvV04
PAGE 1 Of 4
NOTE;
Monsanto material safety data ooo
NO REPRESENTATION IS MADE AS TO THE ACCURACY OF THE INFORMATION AND RECOMMENDA
TiONS HEREIN. SEE PAGE 4 FOR CONDITIONS UNDER WHICH DATAWARE FURNISHED
fcrrrrgjgjj t, ffriM,iami.1, a.a MONSANTO PRODUCT NAME
POLYCHLORINATED BIPHENYLS - PCB's* See page 4 tor definition and note*
MONSANTO COMPANY 800 N, LINDBERGH BIVD ST. LOUIS. MO 63166 EMERGENCY PHONE NO (CALL COLLECT)
<3M) 694-1000
PRODUCT IDENTIFICATION
Synonyms
Trade Names (Commonly ustd Monsanto products)
o
o
PCB'S
Chlorodiphsnyl {__ % Cl) Chlorinated biphenyl Polychlorinated biphenyl Chlorinated biphenyls
(approx. __ 4 Cl)
Askaral** Aroclor*' Series 1016, 1221, 1232, Pyranol*1 Series Inerteen*' Series TherminolB1 FR Series----------
1242,
1348,
1254,
1260 Q
0
*
See page 4 for notae
CAS No. 001336363, 053469219, 021672296, 01109769 , 011096825 and Others
WARNING STATEMENTS Federal regulations under the Toxic Substances control Act require PCB's end PCB items to be marked. (Check regulations fox details.*)
o
CAUTION
PCBs
MmINWM
tAHSsi^maslHsTeIaIH 4mm mayaaeA
Ip m. . ------
THIS EQUIPMENT CONTAINS
PCB
CAPAcrroRts)
! CAUTION
PCBs!
! !ft Rm mort
tuweua now i
I contact u s iMVMOMMfwrai
MOKCTWaClWCT
1
EMERGENCY AND FIRST AID PROCEDURES
O ro CO Dl =3
Ingestion - Contult physician, bo not induce vomiting or give any oily laxatives. o
HOTS TO PHYSICIAN - If lerga amounts ingested gastric lavege la suggested.
Skin * If liquid or solid PCB's ere splashed or spilled on skin, contaminated clothing should be removed and the skin washed thoroughly with soap and water.
S >
--i
NOTE TO PHYSICIAN * Hot PCB's may cause thermal burns.
m 00
Eyes - Eyes should be irrigated immediately with copious quantities Of running water > for at least 15 minutes if liquid or solid PCB's get into them. A petroleum-based
opthalmic ointment may be applied to the eye to relieve the irritating effects of PCB's.
U>)
Inhalation - Remove to fresh air. If skin rash or respiratory irritation persists, consult a physician. NOTE TO PHYSICIAN - If electrical equipment arcs over, PCB's or other chlorinated hydrocarbon dielectric fluids nay decompose to produce HC1, hydrochloric acid, a respiratory irritant.
3
C?
$
G 4048
HONS 002353
TOWOLDMONOO11651
WATER_PCB-00004767
OOO Monsanto material safety data
PAGE 2 OF 4
OCCUPATIONAL CONTROL PROCEDURES
Inhalation * Workplace sxposurs should bs maintained below tha OSha eight-hour, tims-weighted average Threehold Limit Value (TLV). At room temparaturea, tha hacard of inhalation ia considered alight or abeent. Chemical cartridge respirators or gas masks approved for protection againet organic vapors are noossnended in the event of spllla or leaks of hot fluids. These will provide good protection up to the concen trations shown on the approval labele and the odor will give ample warning if it cornea through tha device. Self-contained breathing apparatus should be worn when PCS 'a are encountered in an enclosed apace.
Threshold Limit Value (TLV) - Chlorodiphsnyl (42%) 1.0 mg/cu.m. Chlorodiphenyl (54%) 0.5 mg/cu.m. -
Skin Contact - Avoid prolonged or repeated akin contact, tfhara smployeas may come into direct contact with PCB'a, protective clothing impervious to PCB's should be worn. Glovee. boots, overshoes and bib-type aprons thst cover the boot tops ehould be used when necessary. This protective equipment ehould be regularly inspected for defects and to ensure that it is in clean and satisfactory working condition. Contaminated clothing, gloves, etc., ehould be disposed of as prescribed by regulations.
Bye Contact - Eye protection ehould be used where there ie a possibility of liquid plashes.
Ingestion - Ingestion of these materials is generally not a problem in Industry.
PHYSIOLOGICAL EFFECTS SUMMARY:
Skin Contact - Can be absorbed through intact akin. Local action on akin ia similar to that of common organic aolventa where contact leads to removal of natural fats and oila with aubaequent drying and cracking of the akin. A potential estate for the contracting of ehloracne.
Eye Contact - The liquid products and their vapors are K>35rately irritating to eye tissues.
Ingestion - The acute oral toxicitias of the undiluted compounds aret LDso rata 8.65 gm/kg for 42% chlorinated, and 11.9 gm/kg for 54% dilorinated - "slightly toxic".
Inhalation - Animal experimenta of varying duration and at differant air concentra tions show that for similar exposure conditions, the 54% chlorinated material produces mors liver injury than tha 42% chlorinated material.
Monsanto sponsored animal feeding studies on Aroclor* 1242, 1254 and 1260. These '-ompounds, fed to both eases of rats, did not produce cancers. Svfcsequently. a study rsportsd In ths literature with female rets using Aroelor 1260 stated that Aroclor 1260 caused liver cancers. The national Cancer Institute performed a study in 1977 using Aroclor 1254 with both ssxes of rsts. NCI ststed that the PCS, Aroclor 1254 was not carcinogenic under the conditions of their bioassay.
`
The consistent finding In animal studiae with PCB's is that they produce liver injury following prolonged and repeated exposure by any routs, if the exposure is of suffici ent degree and duration. Liver injury ia produced first, and by exposures that are leas than that alleged to cause cancer in rodents. Therefore, exposure by all routes ehould ba kept sufficiently low to prevent liver injury.
FIRE PROTECTION INFORMATION
HONS 002354
Fire and explosion - ChlorocUphenyls are essentially non-ccmhustible compounds. They may doconposV'to forr. CO, 00j, HC1, phenolics and aldehydes under severe conditions such as exposure to flame or hot surfaces. No phosgene is formed.
MATERIAL SAFETY DATA Monsanto
TOWOLDMONOO11652
WATER_PCB-00004768
PAGE 3 Of 4
Monsanto material safety data o o
Standard fire fighting waring apparel and aelf-oontained breathing apparatus should be worn when fighting fires that involve possible exposure to chlorodiphenyls. Fire fighting equipment must be thoroughly cleaned and decontaminated after use.
PHYSICAL DATA table 1 Properties of Selected AroclorsO
tapert.
C*l U,IU) fhy*Ie*l ttit.
lability Mntltv
*CJ fpoettie yrnvlty ft/14.4'C ftiitUlitlon ran** j*CI
heiiitr mq K0V|, PA ElBUM pir point t*c)
TilCOlitf
iiM'n
ittc Milt *11
1MII 11. H
i*4-i.r
most
*
BOM tO Ml lift* pot ot n-
mi 100 obi i *n
loort VvtS 1.14-1,14 4**4* moit
,*14
in
Mvll
111) 1M Skill Bll iBtft 1MI 1*21*1.14 -14*
,4)4
lit
Ml
1141 It* JDbll* Oil
l,,rt U.M
UH.1I -at* 114*144
.11)
MM tO oillB point 1**1
U4 III Mllll Oil
Iwt 11.44
1*44*1.41 1-41* M**in
til
MM to bOiliBp point. 1*1-144
1114 144 OlpcOM lion * loort 11.11
l.44*lkM 44* Ni.ni
*414
MM tO Mill II* point 14*4-1444
1141 14* tlc*r rntl* inort 11,44
1.44-1 44 *4* MS-414
.411
Mill** point
*
REACTIVITY DATA
PCB's are very stable, fire-resistant compounds. ______________________________________________ _________ __
SPILL, LEAK & DISPOSAL INFORMATION* 1 2 3
If PCX's leak or era spilled, the following steps should be taken Immediately:
All non-essential personnel should leave the leak or apill area.
The area should be adequately ventilated to prevent the accisvulation of vapors.
The apill/leak ehould be contained. Loea to sewer aysterns, navigable waterways and atrearns should be prevented. Spills/leaks ehould be remowd promptly by means of absorptive material, such as sawdust, veneiculite, dry aand, clay, dirt or other similar eaterlaIs, or trapped and removed by pimping or other suitable Means (traps, drip-pans, trays, ate.).
to OJ
Personnel entering the spill or leak area should be furnished with appropriate personal protective equipment and clothing as needed.
g
Personnel trained In the eeergency procedures and protected against the attendant >
bssards should shut ofr sourest of PCX's, clean up spills, control and repair
^
leaks and fight fires in PCS areas,
3)
All wastes and residues containing PCS's (e.g., wiping cloths, absorbent material, ^
used disposable protective gloves, clothing, etc.) should be collected, placed in propor containers marked end disposed of in the Manner prescribed by EPA regulatione (40 CFR 761).
Vsrious federal regulations require reporting of PCS spills' that
rj
m 3
1) pose s "sits tan tisl risk" to human health and the environment, 2) enter weterweys, drainage systems, water courses, shorelines, etc., or 3) the voliSM or .extent of the spill is unknown.
As soon as possible, notify the V.S. Coast Guard national Response Center, (BOO) 424-8602 and the nearest EPA offloe of such a spill.
O> >-I
HON
TOWOLDMONOO11653
WATER_PCB-00004769
Monsanto material safety data
PAGE 4 OF 4
NOTE # although the information and recommendations set forth in this sheet are believed - TO BE CORRECT AS OF THE DATE HEREOF, MONSANTO COMPANY MAKES NO REPRESENTATION AS TO THE COMPLETENESS OR ACCURACY OF SUCH INFORMATION AND RECOMMENDATIONS
a MONSANTO COMPANY SHALL IN NO EVENT BE RESPONSIBLE FOR ANY DAMAGES OF WHATSOEVER w NATURE DIRECTLY OR INDIRECTLY RESULTING FROM THE PUBLICATION OR USE OF OR RELIANCE A UPON SUCH INFORMATION AND RECOMMENDATIONS.
NO WARRANTY, EITHER EXPRESS OR IMPLIED, OF MERCHANTABILITY OR FITNESS OR OF ANY OTHER NATURE WITH RESPECT TO THE PRODUCT OR TO THE INFORMATION AND RECOMMENDA* o TIONS HEREIN IS MADE HEREUNDER.
o This form has been approved by the Occupational Safety and Health Administration aa "equivalant to"
o OSHA Form 20
POLYCHLORINATED BIPHENYLS
o For regulatory purposes, under the Toxic Substances Control Act the term "PCB's refers to a chemical substance limited to the biphenyl molecule that has been chlorinated to varying degrees or any combination of substances which contain
t 50 ppm (on a dry weight basis) or greater of such substance (40 CFR 761) .
Chemically, however, PCB's are defined as a series of technical mixtures, consisting of many isomers and compounds that vary from mobile oily liquids to white crystalline solids and hard non-crystalline resins. Technical products vary in composition, in the degree of chlorination and possibly according to batch.
The mixture generally used contains an average of 3 molecules chlorine per molecule (424 chlorine) to 5 molecules chlorine per molecule (54% chlorine) . They are used as dielectric fluids in transformers and capacitors. Prior to 1972, PCB applications included heat transfer media, hydraulic and other industrial fluids, plasticisers, carbonless paper, paints, inks and adhesives. "Federal regulations now specify that non-totally enclosed PCB activities are permitted only if specifically exempted or authorised." (40 CFR 761, see FEDERAL REGISTER, Vol. 44, p. 31514, May 31, 1979)
CAS No. 001336363.- For general class of compounds
TRADE NAMES
**ASKAREL - Generic name for a broad class of fire-resistant synthetic chlorinated hydrocarbons used as dielectric fluids.
S1 Registered tradsmark of Monsanto Con?any ! Registered trademark of General Electric Company J Registered trademark of Hestinghouse Electric Corporation
MATERIAL SAFETY DATA Monsanto
This list of trade names is representative of several commonly used Monsanto products (or formulate^ with Monsanto products) . Many other trademarked products were marketed by Monsanto and other chemical manufacturers. PCB's were also manufactured and sold by several European ana Japanese producers. Contact the manufacturer of the trademarked product directly, if not in this listing, to determine if the formulation contained PCS's.
DATE September 15, 19C0REVISED
x
SUPERCEDES All prior to 9/15/90
FOR ADDITIONAL NON-EMERGENCY INFORMATION. CONTACT
RONS 002356
John H. Craddock, Manager, Product fi Environmental Safety
Monsanto Industrial Chem. Co. BOO North Lindbergn Boulevard st. Louis, Missouri 63166 17141 94--4764
TOWOLDMONOO11654
WATER_PCB-00004770