TABLE OF CONTENTS
Convert To Therminol for Dramatic Savings.. 1 Total Therminol Systems in New Buildings. .3 Therminol for Heating and Cooling In
Campus -- Type Buildings........................ .5 Therminol FR-1.................................. .......6 Therminol FR Safety of Handling..................... 8
a NEW concept in heating
Therminol high temperature liquid phase heating offers new answers to questions you may be facing in heating system design. Questions like:
How do you tower the capital investment for heating/ cooling equipment?
How do you cut operating costs -- particularly rising labor expenses?
How do you save valuable floor space? How can your system meet rapid changes in heat demand ? How can heating system safety be maximized?
A liquid phase system designed around Therminol heat transfer fluid - in a new building or in the modernization of an old one -- may be your answer to many or ell of these questions.
LITHO IN U.SA 2-307. 0970
1st Proof --SUPERIOR 5086-9-29-70
I
I
0^31730
)
TOWOLDMONOQ32094
PAGK 1
THERMINOL FOR DRAMATIC SAVINGS
When the need to modernize a heating system arises, you will find that Therminof liquidphase heating offers:
Superior operating efficiency. Elimination of licensed boiler operators in many cities. Maintenance reduced by up to 80 percent.
Easy conversion and installation.
Operating Savings
The use of high temperature Therminol eliminates the need for system pressurization. A high tem perature primary loop (see diagram below) is vented to atmosphere, and thus the heaters usually are not classified as pressure vessels. This in turn eliminates the need for a crew of licensed low pressure boiler operators, 8 major factor in the cost of many old systems.
Cut Maintenance Costs
Operation of the new plant is entirely automatic except for pre ventive and operational mainten
ance and system shutdown and startup. These operations can be performed by the regular building maintenance staff.
Easy Conversion and Installation
Installation basically involves re placing steam boilers with fluid heaters. A steam generator can furnish hot water during the con version to minimize inconvenience to your building's occupants. Each of the fluid heaters are con nected to heat exchangers. These converters generate hot water for building heating and domestic hot
water heating and steam for kitchen equipment, garage heating systems and the building ventilation.Two pumps recirculatethe fluid between heaters and converters.
Space No Problem
All system changes can be con fined to the previous boiler room area. Existing piping and equip ment for the secondary services, including building heating service pumps, domestic hot water pumps, and condensate receivers remain in place. Thus, your building's services can continue to utilize water and steam as before.
River House Cooperative Apartments -- Detroit
This system, which has been in operation for more than five years, provides an annual savings of $36,000 compared to the old steam systems; $25,000 through the elimina tion of licensed boiler operators and $11,000 through reduced foe! costs. The latter saving results from an increase in over-all efficiency from 60 percent with the old system to 83 percent with the new, and from switching to gas firing.
lit Proof -- SUPERIOR 5086--9-29-70
0431731
)
TOWOLDMONOQ32095
PAGE 3
TOTAL THERMINOL SYSTEMS IN
BUILDINGS
From open flame, to steam, to liquid phase fluids. Unhappy with early direct-fired heating, engineers centralized the fire and used steam to bridge the gap. Now you can bridge that gap more efficiently with new, high temperature liquidphase heating. Some examples of the ways others have designed Therminol into their heating systems are detailed on this page.
Therminol Versus Steam in an Eleven Story Hospital
Kaiser Engineers sought the most economical heating system for the Tower addition to an Oakland, Calif. Hospital. Consequently, they made a detailed analysis of steam versus Therminol for their 243,000 square foot expansion. Their findings: Therminol's initial installation cost is $21,850 less than steam. The reduction in capital costs was due to the elimination of low and high pressure steam boilers, deaerator feed water heaters, condensate drainage system for absorption chillers, steam piping, related equipment and me chanical equipment floor space. Therminol's operating cost is $8,000 less than steam; a 22 percent annual savings. The reduction in annual operating costs were due primarily to the an ticipated added thermal efficiency of the Therminol System end the reduc tion in preventative maintenance and repair. It was projected that if licensed boiler operators had been required, as is generally the case, sn additional operating savings of approximately $25,000 per year would have been realized by utilizing the Therminol System approach. In addition to these outstanding cost savings, the study found Therminol: 1. Provided excellent response to
building load changes. 2. Created no venting problems. 3. Offered increased safety because of
the non-pressure characteristics of the system. On this basis, a number of hospitals have used Therminol in their heating systems or incorporated it into their designs. Diagrams detailing the design of these two systems 8re on the next page.
PAGE 2
Holy Cross Hospital - Detroit
7he conversion ol this 250-bed hospital addition to therminol liquid phase heating yielded an annual savings of S40.000 in operating costs. This saving was estimated to pay lor the cost of conversion in three years. Moreover, the improved el/iciency ol the system added additional savings through lower fuel costs. J. P. Noble. Detroit consulting engineer, received the firs! honor awardfor mechanical engineering in the 1968 awards competition of the Consulting Engineers Council of Michigan for his design of this system.
PAGE 8
This Monsanto office and laboratory building in Akron. Ohio, was the first to use a high temperature, non-pressuriied, fire-resistant fluid system for atI direct heat needs. These include refrigeration, pre-heat, re-heat, base board, steam generation and hot water. The completely automatic end unattended system utilizes conventional off-the-shelf heating and air conditioning hardware. Installation costs were S10.50, per square foot, or 13 percent of the total building cost.
lit Proof--SUPERIOR 5086-9-29-70
0431732
PACK r,
THERMINOL FOR HEATING AND COOLING IN
BUILDINGS
In addition to high-rise structures, Therminol healing systems offer considerable savings for campus-type buildings, Ferris & Hamig, fnc,, St, Louis consulting engineers, prepared a feasibility study comparing a conventional system with high pressure steam distribution to four varieties of Therminol systems. The Monsanto office complex in Creve Coeur, Missouri, was used as a basis for comparison. This complex comprises a powerhouse and five office buildings totalling 425,000 square feet and including a cafeteria and kitchen. Here's a summaiy of the five systems and their comparative costs:
The report's conclusion: for this campus, applica tion, a Therminol heating system costs less than a conventional system using high pressure steam. And, in addition to eliminating an operating engineer on each shift, the Therminol system would offer; no trap maintenance, no water treatment and lower liability insurance rates.
System
Description
Initial and Operating Cost*
1. High pressure steam distribution to thetive office buildings: with steam pressure reduced in each building to 10 lbs pressure. Low pressure steom was distributed to heating coils in the air conditioning units A central electric motor driven centiifugal water chilling system with condensing water pumps and cooling tower would be installed in the powerhouse. Chilled water meins would be run parallel to the Steam mains in the tunnels with braches to the air condilioning units in each building.
2. Varies from No. 1 in that Therminol healers replace pressure boilers. Therminol supply and return piping are used in the tunnel with branches to each building. At each building e booster pump with a three-way valve would be installed to teduce the temperature of Therminol from 550' to about 276". The Therminol would then be pumped to heating coils in the air conditioning units. The wetei chilling system would be the same as in No. 1.
3. This system is the same as No. 2 except that centrifugal water chillers would be replaced by absorption units in the powerhouse; the cooling tower end condensing water pumps would be increased to reject the additional heat from the absorption units.
4. This system varies from No. 3 in that individual absorption units wifi be insfelfed (n each building.
Condensing water from a central cooling tower and condensing water pumps at the powerhouse will
supply condensing water through the tunnel to these units.
6. This system varies from No. 4 in that individual cooling towers and condensing water pumps would be installed in each building.
$86,997
$83,614 $94,606 $77,476
'These costs do not include savings in labor. 1st Proof -- SUPERIOR 5086--9-29-70
0431733
I
TOWOLDMONOQ32097
PAGK C
The Monsanto Therminol heat transfer fluids have been used for a number of years in a variety of heat transfer ap plications; from rubber rolling to food processing. Therminol PR-1 represents the best fluid for space heating systems. Therminol FR-1 is unique. It permits installation of a non-pressurized system operating with a liquid which has no fire point and will not support combustion. Therminol FR-1 is so fire-resistant, it has been listed with Underwriters' Laboratory. Still another unique property of Therminol FR-1 is its unusual chemical inertness. It is among the most oxidation-resistant compounds known. This inertness pre vents the formation of oxidation sludges if the hot fluid comes in contact with air. This extends the useful service life of the fluid; occasionally allows economies in design. However, Therminol FR-1 is not intended for use in open vessels but in properly vented, closed systems. Chemically, Therminol FR-1 is resistant to strong acids, mild alkalies and dilute solutions of strong alkalies.
PAGE 8
THERMINOL FR SAFETY OF HANDLING
On the basis of animal toxicity studies, THERMINOL FR may be eonsldeted only slightly toxic from the standpoint ot accidental massive skin exposure or accidental ingestion. Similarly, single exposures to high concentrations ol vapors (when heated sufficiently to volatilize) or high concentrations of decomposition products (It the fluid is accidentally discharged into the lire chamber) ere not serious hazards because the irritating charectei ol such concentretions preclude voluntary exposure. Repeated or prolonged akin exposure should be avoided einee THERMINOL FR acts as a solvent for fats and oils of the akin.
chapping such as occurs with exposures to paint thinners More important, THERMINOL FR may be absorbed It It Is allowed to remain on the unbroken skin. For these reasons, wa recommend that the skin be washed with eoap and water if there is contsct. A skin burn resulting from accidental contact with hot fluid ehould be treated in the normal manner for any thermal burn due to hot oils. Because of Its low vapor pressure, there is no significant vapor inhalation hazard whan THERMINOL FR is at room temperature. For example, there is no vapor exposure problom while transferring the fluid from its shipping corifainor to the heat transfer system On the other hand, the vapors emitted by THERMINOL FR heated to alovated temperatures are injurious on prolonged exposure ft is indicated that the "threshold limit value" or atmospheric vapor concentration which cannot be safely exceeded (on a daily bails) is 0.6 - 1.0 milligrams of THERMINOL FR vapor per cubic meter of air in the workroom. In heel transfer installations, the fluid must be used in a closed system free from leaks with the expansion tank vented to the out doors. Accordingly, there should be little or no opportunity tor workers to come In contact with vapors.