Document V9K3B0KLD801Q4NeakDZqYDg
PLAINTIFF'S EXHIBIT
10961 ' | l id V l l D OC N *|!i
boiler-burner units and boilers
A-5 oil-fired boilers
A-MERiCAN-^tandard. 12868
A-5 oil-fired boilers--efficient design, economical installation, durable construction
Au**otie ail hsefisg for medium-tit* auiidtngt --Tile A-5 Oli-fireo unit is designed for installation in large domes and small to medium-sire apart ments and commercial buildings. This modern boiler has been engineered specifically for oil operation and outstanding performance. It's available in a full range of eight sires for hot water or steam (six sires available as boiler-burner units). Exclusive design for medium-range heating requirements, the A-5 boiler is available with jacket extension.
four oulllonding tngm**r-d*tign*d Immih-First, MW vertical flue section design reduces weight. Second, unique hot water tankless heater arrangement permits adaptable installation to meet varying domestic re quirements. Third, cast iron sections assure long, dependable service. Fourth, wet base construction extends waterways beMath combustion area for addi tional heat-absorbing bottom surface.
inttoHotion rim* and co ur-Vertical flue design considerably re duces weight of boiler for easier handling on job. Wet base construction provides a built-in base for each section - no special base required - and permits unit to be installed on combustible flooring. Pre-cast combustion chamber saves time of building chamber. Largest steam assembly can be installed with a single 4" supply-eliminates cost of added header.
New tankless heater arrangement -- A-5 center sections incorporate a new design principle which allows a separate tankless heater to be easily inserted in each center section. With this unique arrangement only one size tankless heater is required for any size hot water or steam boiler. The A-5 economically meets modem domestic hot water requirements. For example, one heater may supply high-temperature water for automatic washers, another heater may supply faucet water and a third for snow melting, first tankless heater rating is 4 gpm, each additional tankless heater 3 gpm. A special copper manifold assembly is available for con necting multiple heaters in parallel, pre-fabricated to reduce installation time. Special center sections are supplied on all A-5 boilers ordered for tankless use. The first tankless heater is installed in the first center section behind the front section. Each additional heater is placed in the following center section. The number of special center sections varies depending on boiler size. Boilers can be ordered with special center sections throughout, at no extra cost, when so specified.
American-Standard A-5 oii heating units have ratings approved by the Institute of Boiler and Radiator Manufacturers and are constructed to the specifications of the American Society of Mechanical Engineers. Model DH-5 and Model LF-A Arcoflame oil burners, used with A-504 through A-509, are listed by Underwriters' Laboratories, Inc., for No. 1 and No. 2 fuel oil, comply with Commercial Standard CS-75 and are approved by the New York City Board of Standards and Appeals, by the State Fire Marshal of the Commonwealth of Massachusetts and by the Department of Police. State of Connecticut.
12869
net l = l = R rating
* >l*r-bu mer units
steam
watar
numhara
ttaam
watar
steam Btu/hr
ft
tu/hr
grata 1=1=1 output
I = R= R burner capacity
(Phe
chimney
size inchea
height feet
A-504-SB A-504-WB A-504-S
A-504-W
195.800
816 195,800
261
2.55
A-505-SB A-505-WB A-505-S
A-505-W
259.600
1082
259^600
346
3J0
A-506-Sb A-506-WB A-506-S
A-506-W
319.600
1332
319.600
426
4.00
A-507-SB A-sng-^B
A-509-SB
A-507-WB A-509-VYB A-509-W5
A-507-S ASMS A-509-S
A-507-W
a erte m n-vwvr n
A-509-W
381,100 441,100 501.100
1588 1838 2088
381,100 441,100 501,100
508 096 668
4.75 5.55 6JO
-
--
A-510-S A-510-W
561.100
2338
561,100
748
7.00
--
--
A-511-S
A-511-W
622.700
2594
622,700
830
7.65
Add suffix latter T to boiler number when one or
-------------------------- ---------- --------- -------------- ------- ....
Note: TANKLES* HEATER KATINS* - First tankless heater 4 torn, each additional tankless heater 3 gpm.
8x12 8x12 12 XL? 12x12 12x16 12x16 12x16 16x16 neeiertsf No. 530.
15
20 20 20
25
25
25
30
e Nozzle size, coh, furnished 5.00-WH; A-509. S.OO-WH.
with
A-5
units
are
as
follows:
No.
A-504,
2.50-60*
or
70*S:
A-505.
3.00-60`H;
A-506.
l.S0-*H;
A-507,
4,S0-80*H;
A-508.
dimensions and tappings
M
boiler number
A-504 A-505 A-506 A-507 A-508 A-509 A-510 A-511
r -3-: i :e . j.v
number ana size tappings-inchas
flew
2-4" 24" 2-4" 24" 2-4" 24" 24" 2-4"
return
4-2W' 4-2%" 4-2%" 4-2 %" 4-2%" 4-2V4" 4-2%" 4-2 %"
A
18 22Vz 27 31Vfz 36 40 % 45 49%
13% 16% 16% 16% 16% 16% 16% 16%
center section showing tankless water heater
dimensions--inches
L C flush jacket
9 22% 9 27% 10 31% 10 36% 10 40% 12 45% 12 49% 12 54%
L jacket extension
47% 52% 56% 61% 65% 70% 74% 79%
assemblage of sections
bbiler number
A-504 A-505 A-506 A-507 A-508 A-509 A-510 A-511
srrsngsmtntA of sections
fTcTcTb
F, C, C, 0, B F, C, C, Cs C, 8 F, C, C, C, C, C, B F, a c, Cs Cy 0, C, 8 F, C, Cf C, C, C, Cs C, B F, Ct C, C, C, C, Cs 0, C, B F, C, C, C, C, C, Cs C, Cs C( B.
F-Front connecting section C--Center section B-8ack connecting section
ACT section with heater opening substituted for C section as specified
control a oplications
location
size
on boiler inehes
steam
water
J
F 2% low water cut-off
not used
G % pressure limit control temperature limit control
H
% operating control tankless heater
not used
J % pressure gauge
combination altitude gauge and thermometer
K % not used
operating control tankless heater
L % not used
reverse acting control
snowing control taoomgs
Note:--2" Blow-off on back of back section 2" Safety or relief valve on top of back section.
4 H
^ American-Standard A-5 Oil-Fired Boilers are another development in hydronics--the science of heating and cooling with water.
12871
A.MERiCAN-c$tandard plumbing and heating division
uo :
AMERICAN RADIATOR & STANDARD SANITARY CORPORATION A0 WEST AOTH STREET . NEW YORK 18, NEW YORK