POLYMER PRODdcTS OEPT. WASHINGTON WORKS
GLOVE TESTIHS FOR 6 (Amman jiuin Perfluoreoctanoate) PERMEATION
Haskell Laboratory Report No. 612-81 i<^Mp----a*f
Results of the evaluation of five types of gloves for their permeation resistance to a 30 aqueous solution of C-8 and C-8 dry powder are reported below. Samples of the gloves ware tested in duplicate in 10 oL glass Baskell permeation cells with water used as a collection medium on the inside surface of the gloves. A 10 mL aliquot of the collecting medium was analyzed for C-8 after 4n 8 hour exposure 'ay spactrophotometry following the methylane blucf method for determination of C-8 and C-9
dispersing agents.l1^ Breakthrough was determined when a detectable amount
of C-8 was found in the collection medium. The minimum detection limit for C-8 was 1 ug/mL in the collection medium.
Results;
:
The results of the evaluation are shown in Table 1.
Discussion;
Results of the evaluation show that three of the glove samples do have a measur.uile breakthrough time and permeation rate after 8 hours of continuous exposure to a 30% solution (jf C-8. However, the permeation rates are very low indicating that the materials do offer some resistance to C-8.
Results of the tests performed with C-8 powder show that in four of the glove samples no breakthrough was observed after eight hours of continuous exposure and only a very small amount permeated in the yellow latex sample from Best Manufacturing Company.
Therefore, depending on the intended use of the glove for protection against C-8, either the Nova 327-y (latex glove) or Best Manufacturing Article 724 (neoprene rubber) glove would offer the best protection against C-8 in solution or as a dry powder.
CompanySanittead. Does not contain TSCACBt
Report by.- y"^**-
^. Monnan W. Henry,
ill Research Chemist
Approved by: ' JJ-t^^^*J^ jj4^1i /^ji^i^-^Bruce M. Monroe Section Supervisor Analytical Chemistry Section
(1) Polymer Products Dept. Method Code number W 240.240 10/9/69 pgs. 1-5
MWHsBMM.-jms
Date Issued: October 23, ,SL Report So.: 612-81
1981
a
-2-
^
Company Sannixed. Doss not co^ai!, TSCA C&?
TABLE: 1
Glove Material
Color
Thickness
mm
Edmont-Wilson Scorpio (Neoprene)
London Rubber Limited (Neo-synthetic- latex-- -
rubber, floe lined)
Green Pink
1.42 .64
Nova Rubber Company,
Yellow
.76
i^ Nova 327-Y (Latex)
Best Manufacturing
Yellow
.S3
Article 702
(Natural Latex)
Best Manufacturing
Black
.71
Article 724
(Neoprene Rubber) .
(2) none detected after 8 hours continuous exposure
Breakthrough Time
Hours
30t sol.
powder
<6
N.D.
<8
N.D.
(2) N.D.
<8
N.D.
<8
N.D.
N.D.
Permeati Mg^mi
30% sol. 0.5 0.1
U.D. 0.3
N.D.
Company Sanitized. Does no