fi/TY UNION CARBIDE CORPORATION CHEMICALS AND PLASTICS P.O.BOX 471, TEXAS CITV, TEXAS 77590 April 21, 1980 Mr. Howard Houston (2) Texas Air Control Board 6330 Highway 290 East Austin, TX 78723 Subject: Supplemental Statistical Evaluation of Additional Six-month Analytical Data, Request for Change in Sampling and Analytical Program Under Part 61, NESHAPS Regulation for Vinyl Chloride Monomer Control Dear Mr. Houston: In January 1980, we sent you a request for the above noted change and have received your response that you had directed it to the TACB Source Evaluation Section for review and subsequent forwarding to the Regional EPA office in Dallas with TACB recomnendations. We would appreciate your forwarding us a copy of the recommendations developed by your Source Evaluation staff when it is available. We would like to keep this issue alive and accordingly would need to know to whom in the Dallas EPA offices you had sent this communication so we can answer any questions or determine what course to follow to expedite the request. We are spending considerable funds (over $50,000/year) wastefully In order to follow the program specified in the NESHAPS Regulation and would like to get relief as soon as possible, realizing that the route will be circuitous and involved in bureaucratic procedures and personnel. Since the original request was made, we have accumulated an additional six months of data for this regulation under the same provisions as before. We have analyzed the new data statistically in the same manner as before and have again come to the conclusion that our prior request for a once-per-week schedule of sampling and testing would more than meet the needs of the regulation and would afford us savings of over $50,000 per year. Please see the attached information developed for the period September 1979 thru February 1980. Please direct any questions and comments on this matter to my attention. We would appreciate receiving the information requested in the first paragraph of this letter at your earliest convenience. Thank you for your help and understanding. Very truly yours. AI.'F. Erdmann, P.E. Environmental Protection Coordinator (713) 948-5126 0FE:ir Attachments cc: Mr. Sabino Gomez, Region VII, Bellaire, Texas Dr. E. R. Ibert, GCACD bcc: R. E. O'Bryan/NESHAPS (VCM) File S. A. Dickerson J. B. Leverton/J.S. Knight R. M. Arnold J. H. Barrett D. G. Reese G. F. Tacquard P. D. Smith R. R. Rankin - CLC J. D. Martin - 510 W. T. Gray, Jr. D. R. Reem UCC 051468 NAME: _ POSITION ucc 051469 DATA EVALUATION, SEPTEMBER 1979 - FEBRUARY 1980 (Data Tables Appended) Individual twenty-four hour weighted average VCM concentrations (dry resin basis), A_., were determined and reported for this period in our last Semiannual1Report submitted April 7, 1980. The following statistical parameters were determined from these daily VCM concentrations: 1) Number of daily average values of A.^. = n = 182 2) Population Mean, y = 20.45 3) Standard Deviation, Sx = 72.59 4) Predicted upper range for mean values, 99% confidence level. v= X + Sx ( z) , Z for 99% level = 2.33, for n > 30, rr ' ' upper limit only. y = 33,00 This valuation indicates that the mean value for the VCM concentrations based on this second six-month data period would be below 33 ppm 99% of the time. This compares to an upper limit of 400 ppm specified by the regulation. y - maximum specification level Determine t = standard deviation, S,, 20.45 - 400 t= 72.59 _ -379.55 72.59 -5.23 However, from Table A In the text, a t-value of -3.1 is shown for a 99.9% confidence level (0.0010). The larger t-value of -5.23 would correspond to a considerably greater degree of confidence than expressed by the 99.9% level. By using the following notation, a calculation can be made to determine the sample size (n), which would provide 99.9% confidence that we would not exceed the 400 ppm limit. Ucc 0S147Q Let a = risk of rejecting an acceptable value = 0.001 and let 0 = risk of accepting a rejectable value = 0.001 for a = 0.001, ^ = 3.1 = K - u = K - 20.45 ^ Sx 72.59 Hr vr For 6 = 0.001, T2 = -3.1 = K - upper limit S ""if = K - 400 (6) 72.59 ~T Subtracting equation (A) from equation (B): t2 - T1 - -3.1 - (3.1) = K - 400 - K - 20.45 72.59 72.59 -6.2 = K - 400 - K + 20.45 72.59 -379.55 72.59 Kn 6.2 379.55 {T, (T = 1.186 (just over one sample required) 72.59 n = 1.41 This value for n is slightly greater than 1, so a sample of 2 is the next nearest whole number. If we use this value of n * 1.41 to solve for K, the mean value of At. that would assure not exceeding 400 ppm more than 0.1% of the time, we get the following: -3.1 = K - 400 -3.1 = K - 400 72.59 m 61.20 -2- ucc 051471 K - 400 = -189.7; K = 210.3 However, we can't take part of a sample, so using n = 2, -3.1 = K - 400 -3.1 * K - 400 72.59 51.33 = 1.414 K - 400 = -159.1 K = 240.8 which is the value of ATi for two samples every six months below which there is over 99.9% confidence that the 400 ppm limit has not been exceeded. However, we plan to sample once per week to get A_. for a regular 3-shift day, sampling each stripper each shift for'a total of 12 samples from which one weighted average concentration can be determined for that day. In six months, 26 such A-. values would be available, and If their mean value doesn't exceed the following K value, there is 99.9% chance that all values are below the 400 ppm limit. -3.1 = K - 400 72.59 K - 400 72.59 TT~ K - 400 14.23 -(3.1) (14.23) = K - 400 -44.1, K = 356 ppm UCC 051472 -3- Date 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 SEPTEMBER, 1979 Ati 4.49 1.81 0.18 596.67 2.36 0.64 2.04 0.17 1.50 0.00 0.00 5.97 18.14 31.61 3.25 2.41 0.88 25.41 5.57 2.86 2.71 1.15 0.15 4.33 6.64 23.70 11.60 14 .40 368.20 168.35 Ucc OSf73 Date 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 OCTOBER, 1979 Ati 7.17 4.99 0.91 7.93 0.03 1.77 5.79 18.80 41.84 118.33 5.44 17.52 5.58 0.69 30.87 4.30 7.72 13.47 17.14 37.86 6.42 40.56 54.93 2.33 181.66 49.26 58.61 4.06 6.89 6.33 1.46 ucc 051474 Date 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 NOVEMBER, 1979 Ati 4.09 18.66 19.30 2.89 34.60 22.40 27.33 5.68 12.70 5.88 2.16 4.90 0.35 3.48 0.43 1.00 0.86 5.97 147.27 6.44 2.32 2.03 11.68 1.31 0.87 0.00 0.84 8.38 9.91 6.75 ucc 051475 ) ) # Date 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 DECEMBER, 1979 Ati 0.00 167.13 6.49 7.31 3.49 17.97 60.82 2.51 0.34 0.40 0.26 4.80 1.40 8.90 2.70 73.90 4.20 8.50 13.28 6.90 4.37 6.76 31.71 8.58 18.06 2.28 7.15 2.21 14.35 1.06 0.00 ucc 051476 Date 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 JANUARY, 1980 Ati 0.22 8.01 3.89 611.95 2.27 .48 .44 .52 2.16 1.73 2.11 0.00 24.71 52.84 .33 .10 0.00 .35 1.93 .13 .83 2.68 .71 .58 .03 3.52 .33 5.17 9.50 .65 1.43 ucc 051477 Date 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 FEBRUARY, 1980 Ati .23 .31 .45 1.46 .52 3.26 1.11 .57 .15 1.29 6.44 .55 .13 .26 7.15 .38 3.12 2.74 6.77 1.99 3.02 2.03 1.10 1.89 .38 0.00 .97 8.48 0.00. Ucc sn?a