rnoM _E,._W _R._L ! HARRINGTON__________________CLEVElANp,,ORFIOE FT FLU FD'NT TOOLE CLEVELAND OFFICE dA45Q STAFFING FOR OSHA CHLORIDE REGULATIONS PATC iHit ^Tf^H Each of the FVC plants has approached the problems of staffing to handle the activities involved in compliance with the VCM standard in a little different way. The size of the plant, age of equipment, diversity of products, and plant "personality" have been factors leading to different approaches to the additional burden involved in adapting to the new way of life. Comparison is most inexact but the recent attempt to obtain sim ilar data from each plant has provided some interesting comparisons. ALGO HENRY LOUISVILLE LONG BEACH FEDRICKTOWN Total Employees PVC Employees 642 164 Authorized Employees 339 Number of Regulated Areas 4 Nuiriber of Personal Monitorings/ Month 396 319 ll4 182 1 130 1039 215 425 5 454 142 47 57 1 124 247 58 136 2 170 EstiBBted Time - Man-hours/Month (MH/M) Personal Monitoring Leak Detection 300 230 90 200 Anal. Laboratory Record Keeping 1090 130 174 50 Medical Surveillance (Nurses) 356 87 350 740 850 135 356 90 90 520 35 43 84 145 215 153 273 Total Estimated Time (MH/m) Monitoring, Leak Detection, Analytical, Record Keeping, and Medical 2150 557 2430 778 870 Equivalent Number of People 12.4 3.2 14 ^5 5-0 Equivalent Number Per 100 PVC Employees 6.7 3-5 6.5 9-5 ** * 8.6 Assignment of Safety People Total Safety (Including Nurses) Number for OSBA VCM Total Nurses Number for OSHA VCM 8 3-7 3 2 3 0.7 1 0.5 11 2 3 . 0.5 51 2 0.25 3-5 1.1 1 0.6 NCY. 11 73 LIT HO IN U A. A. NGC 17674 E* V* Harrington -2- September 5* 1975 Who Handles Personal Monitoring ALGC Environmental Health (Safety) Henry S/E Operators (4 Special Production People) Louisville - Environmental Dept. (3 engineers, 6 operators) Long Beach - Laboratory Operators Pedricktown - Technical Trainee Leak Detection ALGC - Foreman, Operators (Regular Production) Henry - s/e (4 Special Production People) Louisville - OVA (4 Special Mfg. Processes People) Long Beach - Foreman, Operators (Regular Production) Pedricktown - Operators (Regular Production) Record Keepii-g ALGC Nurse, Operators, Environmental Dept. Henry Nurse, OSHA Administrator, Professional Service Emp. Louisville - Nurse, OSHA Administrator Long Beach - Nurse, OSHA Administrator Pedricktown - Nurse, Technical Trainee, Chemist Overall, it seems that 3*5 to 95$ of people assigned to the PVC departments are devoted to the specific Jobs of Personal Monitoring, Leak Detection, Record Keeping and Medical Surveillance. These tasks might be considered direct involvement in OSHA VC1 compliance. In addition, of course, is the rather substantial effort in the less direct engineering, production and technical areas. RLT:Jmh cc: OSHA Administrators H. Waltemate J. KLupar R. L. Toole NGC 17675 B.F.COODRICH CHEMICAL COMPANY ENVIRONMENTAL HEALTH AGENDA Second Meeting; October 20, 1975 " 8:30 a.m. - 10:30 a.m. Cleveland Office - Conference Room 1-B The first meeting set the policies and objectives of the committee. Subsequent meetings will cover details of specific chemicals. I. VCM review. a) Whitney's letter of 10/6. b) New GC for NIOSH/OSHA method. c) Criteria for method acceptance. II. Medical exams for Carbopol employees. III. Benzene - review and clarification. IV. Lead a) Proposed OSHA standard - should we comment? b) Monitoring frequency, sampling procedure, etc. V. Carbon monoxide - procedure for OTA. VI.Acrylonitrile - frequency, analytical procedure, abatement. VII. Butadiene - frequency, analytical procedure, abatement. VIII. Styrene - frequency, analytical procedure, abatement. IX.Computer storage of data other than VCM. JAK:cj 10/13/75 cc: Committee O.F. Beckmeyer L.B. Crider E.W. Harrington M.N. Johnson, M.D. E.B. Katzeruneyer, Jr. J.A. Klupar W. Moorehouse P.D. Terry H. Waltemate T M WVi { f.A. Klupa Others J.L. Nelson R.W. Strassburg J.E. Stroope V.C. Holbrook B.M.G. Zwicker NGC 17676