Document V3Kmbe6JkxYZXm15Or0Vg78ZZ

ABD00342707 CQNOCO CHEMICALS - ABERDEEN PVC PLANT DOSIMETRY CARD (A) SAMPLE N2 1347 Analyst: .Analysis Date Hazard VCM Noise Lead {Micrograms)l PEL: 1 PPM Over ( ) TOT: Under ( ) PEL: 115dBA Per M3 TWA Exposure ) PPM % of PEL Per M3 ABD00342708 HAZARD VCM SAMPLING/ANALYTICAL METHOD Personnel dosimetry (breathing zone) for 8-Hr. TWA, using carbon in REAL "Minimonitor," followed by analysis using Perkin-Elmer F42 Headspace analyzer. LEAD NOISE Personnel dosimetry (breathing zone) for 8Hr. TWA, using - Bendix Mod. B DX-44 Pump @ 1.5 1/min. flow rate and Gelman #4337 filters; followed by atomic absorption analysis. Method complies with 1910.1025 Lead. Personnel dosimetry (hearing zone) for 8-Hr. TWA, using Dupont Mod. D-100 Audio Dosimeter, followed by noise cell analysis using Dupont Mod. R-225 Dosimeter Readout. CONOCO CHEMICALS- ABERDEEN^1?^NT DOSIMETRY DATA CARD (B) _ M0 SAMPLE nnA _ I 04/ Hazard: VCM {/> Lead ( } Noise ( }( i Date ft'tIf4 if. ,Time Clock ( Lead Sampling Only) :IN: ) PM|^) 0UTl_^_22S AM(^T PM( List areas you spent most time in and estimate amount of time (nearest hour is sufficient) sp^nt. Area Time Area Time (/'*'/L ) List most likely causes of possible overexposure to the hazard. 1________________________________________________ 2________________________________________________ 3________________________________________________ Check respiratory protection you used: None ( ) Dust Mask ) Air-line Respirator Signature Please cooimplete and return to guard Scott Air-pak