Document V3B0XxzMd6Gjjdz1Dopxm0vrK
Boilers
Leader Iron Works
General offices: 3010 N. Jasper St., Decatur, Illinois
New York 21 E. 40th Street
Chicago . 451 W. Erie Street
St. Louis 2091 Ry. Exchange Building
KOOLSTACK BOILERS
for
OIL BURNING, COKE, and ANTHRACITE COAL
Low Stack Temperature. Leader Koolstack Boilers operate with stack tempera tures of less than 300 deg. fahr. Economy is the result.
Heating Surface. Koolstack Boilers have far more than the usual amount of heating surface.
Fire Travel. Flue gases pass from com bustion chamber to the top of rear tubular section, then down through the tubes and out at the bottom.
Economy. The unusual economy of Leader Koolstack Boilers is due to the fact the flue gases are held in the boiler until all of the effective heat has been released.
Automatic Damper. Tempo rary draft acceleration at the initial firing period is provided by an automatic damper which by-passes the products of combustion direct to the chimney. This damper closes automatically when the stack temperature reaches 250 deg.
For Oil, Coke, and Anthracite Coal. While this is primarily a boiler for Oil Burning, it shows remarkable performance records on Coke and Anthracite Coal. It is not intended for use with soft coal.
Koolstack Boiler Specifications
(A3.M.E. Code)
STEAM HEATING
Type
OS-2848 OS-2854 05-2860 OS-3954 OS-3963 OS-3972
Net Rating Sq. Ft. Note X
800 1000 1200 1600 2100 2600
Approximate
Shipping Weight
Lb. ,
Grate Diameter
In.
I2000
2200 2400
3500 33'%
3900
33'%
4300 33>/j
Width Overall
In.-
&
46 46
Height Overall
In.
52>/4-
61 to/, 79>/
Length Overall
In.
P
90 90 .
Size Smoke Outlet
In. 10 10 10 12 12 12
Size Size Height Flow Return of Water Opening Opening Level In. In. In.
33
Iy/i y/%
k
4 y4'%/i
5 56
HOT WATER HEATING
OW-2S48 OW-2854
4 P 2% siOW-2860
OW-3954 OW-3963
1280 1600 1920. 2880 3520
2000 2200 2400 3500 3900
fi
46
52V. 68% 61 90 70% 90
OW-3972
4160
4300
46 79% 90
$AU of these ratings are based on actual boiler capacity at outlet.
546
10 10 10 12 12 12
33
y/i y/t 44
t*4>/: */i
4'A 5
Boilers
Monitor Boiler Company
1505 Race Street
Philadelphia, Pa.
pATT STEEL HEATING BOILERS
LU1L AND WATER HEATERS
OIL OR COAL BURNING
It is the amount of heating surface, provided it is properly placed in relation to the fire, that determines the amount of oil or coal used to heat a building. The amount of heating surface per unit of rating in the Coil Boiler is exceptionally high and is tremendously effective because it is within view of the flame, hence, capable of absorbing the radiant heat.
NET RATINGS
The Coil Water Tube Steel Boiler is rated on the amount of direct cast-iron radiation the boiler will carry. Example: A boiler rated at 800 ft. will carry 800 ft. of direct cast-iron radiation. A sufficient reserve has been figured in the rating to take care of piping, except where unusual con ditions exist, such as exposed piping, insufficient radiation, etc., where allowance must of course be made.
DIMENSIONS AND RATINGS
COIL WATER TUBE STEEL HEATING BOILERS
COIL STEEL WATER HEATERS
Number of
Boiler
SAW 1181 SAW 1201 SAW 1231 SAW 1251 SAW 1281 SAW 1282 SAW 1311 SAW 1312 SAW 1351 SAW 1352 SAW 1401 SAW 1402
Net Steam Rating
325 450 550 675 800 950 1150 1400 1600 1950 2350 3000
Net Water Rating
525 750 900 1100 1325 1575 1900 2325 2600 3250 3800 5000
Crate Sq. Ft.
1.8 2.2 2.9 3.4 4.3 4.3 5.3 5.3 6.7 6.7 8.8 8.8
Tapping*
Size
m
4-3 4-3 4-3 4-3 4-4 4-4 4-4 4-4 4-4 4-4
Smoke Pipe
7* 7" 8* 8* 10* 10* 10* 10* 12* 12* 14* 14*
BrarNumber Ggcity
Heater per Hour
Smoke Pipe
Size
10 400 7* 12 500 7* 14 750 8* 16 950 8* 18 1150 10* 20 .1450 . 10* 44 1650 10* 48 2050 12*
4-21/j 4-2Vz +-3 4-3 4-3 4t4 4-4 4-4
Above ratings based on raising tem perature of water 50 deg. per gallon
Working pressure 125 lb.
All Boilers and Heaters built in accordance with' the A.S.3T.E. Code.
547