neunng systems. g^oa Rite Engineering and Manufacturing Gorp. 144 South Mission Road, Los Angeles 33, California ` Phone ANgelus 9-7329 RITE HEATING and HOT WATER SUPPLY BOILERS GAS and OIL FIRED Water-tube type, designed for maximum efficiency and for every water heating pur pose. They are constructed and tested in accordance with the ASME steel boiler code, and we are authorized to apply the appropriate code symbol. Boilers are built with steel or copper 2 in. O.D. tubes. The boiler fire-box is cast at the factory. The boiler is insulated with rockwool and is covered with baked enameled steel jacketing. Boilers are shipped completely assembled with burner, operational and safety controls, and factory-installed wiring. RITE boilers are available with natural gas, L.P.G., mixed gas, Mfg. gas, light oil and gas-oil combination burners. DATA .. wtn a WJ oSQ5 J5 Si u Pu-s e- s & 5. O E.D.R fit &OH w PL 6 2 a K PL d X CO.03. XtQ <cp<lur 15 150 120 20 200 160 25 250 200 30 300 240 36 360 288 42 420 336 48 480 384 55 550 440 63 633 504 76 760' 608 90 900 720 105 1,050 840 120 1,200 960 135 1,350 1,050 150 1,500 1,200 165 1,650 1,320 180 1,800 1,440 200 2,000 1,600 225 2,250 1,800 250 2,500 2,000 275 2,750 2;200 300 3,000 2,400 325 3,250 2,600 360 3,500 2,800 375 3,750 1,000 400 4,000 >,200 425 4,250 400 450 4,500 ,600 475 4,750 (3.800 500 5.000 14,000 800 240 140 1,066 320 190 1,333 400 240 1,600 490 290 1,920 580 350 2,226 680 430 2,560 780 470 2,933 900 540 3,360 1,020 610 4,053 1,230 740 4,800 1,460 870 5,600 1,700 1,020 6,400 1,950 1,170 7,200 2,200 1,320 8,000 2,430 1,460 8,800 2,680 1,600 9,600 2,920 1,750 10,666 3,250 1,950 12,000 3,660 2,190 13,333 4,060 2,420 14,666 4,470 2,680 16,000 4,880 2,920 17,333 5,280 3,160 18,660 5,690 3,410 20,000 1,100 3,660 2212,,363636 >,500 1,900 1,900 4,140 24,000 .310 ,380 25,333 ,700 1,610 26,666 .120 1,860 7 8 9 11 13 15 18 20 24 28 35 43 48 53 58 63 68 73 84 91 98 105 113 120 127 134 141 148 155 163 520 600 650 700 760 820 850 950 1050 1300 1600 1800 2000 2200 2400 2600 2800 3000 3100 3350 3600 3850 4100 4350 4600 4850 5100 5350 5600 5850 OUTSTANDING FEATURES COMPACTNESS BOILER-BURNER-CONTROLS UNIT --Completely packaged unit. RUGGEDNESS--Designed for 125 lb W.P. VERSATILITY--Space heating or hot water supply. SWIMMING POOL HEATING--Boilers equipped with copper tubes and nonferrous coating on a steel header. LOW DRAFT LOSS--Combustion prod ucts travel upwards. Minimum of stack required for gas-fired operation. COPPER TUBES--Are available in all RITE boilers. EASY TO CLEAN & MAINTAIN--Head plates remove easily. COMBUSTION CHAMBER--Fire-box high - temperature resisting refractory. Insulation thick layer of rockwool. QUIET OPERATION OIL BURNERS--Equipped with best available. CUSTOM BUILT--Special equipment or controls as specified. OPTIMUM WATER SURFACE ELECTRONIC PILOT SAFETY--Stand ard on 2,250,000 larger burners. 1404 Heating Systems Radiation Shaw-Perkins Manufacturing Company 201 E. Carson St. ' Pittsburgh 19, Pa. Cutaway--Shaw Modd A MANUFACTURERS OF Shaw Panel .Radiators--Wall Hung or Free Standing Perkins Industrial and Ceiling Radiators Shaw Baseboard Panel Radiators Corner Radiators Marine Radiators FEATURES---------- Long Life--Steam or water path 100 per cent non-ferrous. Strong box-type sec tional construction. Entirely factory as sembled. Space Saving--Only three inches thick. High output. Safe--High pressure test. Rounded cor ners and grilles. Clean--Wide fin spacing. Smooth sur faces. Comfortable--Warm Panel Heating. Gentle air circulation. Shaw-Perkins Panel Radiators combine two of nature's basic elements--warm circulating air and mild radiant heat rays--in exact engineered proportions to pro duce activated, vitalized heat which permeates the entire room. Air is heated in each section of Shaw-Perkins Panel Radiators by the full length rigid steel plates which are positively bonded to the copper tubing containing the steam or hot water. The side walls of each section are also positively locked to the copper tubing and conduct heat directly to the radiant panel. .This unique construc tion assures the exact engineered proportions of warm circulating air and mild radi ant heat rays which are necessary for health, well being and efficiency. Shaw sizes from 3.9 sq ft EDR to 110 sq ft (I lb steam); Perkins sizes to 187 sq ft (1 lb steam). As high as 582 sq ft in one unit (150 lb steam). Shaw heights from 8 in. to 26 in. in front or top air outlet; Perkins heights from 14H in. to 32)4 in. Supply and return tappings on same or opposite ends. Shaw and Perkins radiators may be used on hot water systems, steam or vapor systems, high pressure steam systems and high temperature water systems. The many sizes and models of Shaw-Perkins Panel Radiators make it possible to select and to cover--with one specification--the correct Shaw-Perkins unit for any heating requirement--from one catalog--one set of heating tables--one source--one company. All sizes and types retain the same basic appearance which gives every Shaw-Perkins installation "the professional touch." Represented in all principal cities. Send for catalog "Modern Radiation." 1405