238 THE PHILIP CAREY MFG. COMPANY/CINCINNATI, OHIO 45215 Gs&srtsmp PIPE and BLOCK INSULATION... up to 1600 F. Careytemp is an all-purpose industrial insulation composed of expanded silica reinforced with inorganic fibres and offering all the properties you need for high efficiency. Lighter than other industrial insulations, yet exceptionally strong, Careytemp offers high, moisture resistance, low shrinkage, low thermal conductivity and high acid and cor rosion resistance. Sizes in clude blocks up to 24" wide,pipe insulation in half sections through 24'pipe size; precast elbows. W through 16* pipe size, and traced pipe insulation 3* through 12' pipe size. Cutegietttff 2000* BLOCK INSULATION...up to 2000 F. A strong, high density, diatomaceous earth insulation for furnaces, ovens, kilns, boilers, etc. This is a diatomaceous earth base material with an ideal combination of proper ties. Low K factor low shrinkage, high resistance to abrasion and high compressive strength make Careytemp "2000" a logical specification for the most demanding high temperature applications. Flat blocks are available in many sizes and thick nesses from 1' through 6' in W increments. DUAL Cuteyle*tu PIPE INSULATION... 35 to 350 F. A dependable insulation for piping systems carrying hot, cold or alternating hot and cold liquids through a temper ature range of 35* to 350* F. Extremely low moisture ab sorption, high flame resistance and high rigidity make Dual Careytemp an ideal insulation for any dual temperature job. It comes in molded half sections--with a factory ap- plied, fire-resistant vapor barrier jacket -- in thicknesses of through 3*aHd in a variety of to meet specific job requirements. THERM0GLAS PIPE COVERING Thermoglas pipe covering is used for pipe temperatures up to 350* F. It simply snaps in place. It .is recommended for hot water and low-temperature steam piping in indus trial plants, commercial buildings and institutions. It can also be used as an outside layer over a high-temperature insulation. Tough, semi-rigid and resilient, Thermoglas is an exceptionally light insula tion composed of tong, blown glass fibres bonded with phenolic resin. It comes in one-piece sec tions made in 3 ft lengths. .Canvas and felt jackets are available. PLUS a complete line of accessory products and low pressure insulations including Thermoglas Roll Form and Board, Industrial Mineral Wool Blankets, 7CF Mineral Wool Board (700 F.), Flexible Tubing, Mineral Wool Insulating (MW-50) and one coat finishing (MW-One) cements and numerous weatherproofing compounds and jacketing materials. Also a complete range of asbestos insulating, finishing cements and many other products. For new Careytemp Catalog, Form No. 6627, or complete line catalog. Form No. 6551, ask your Philip Carey representative or write Dept AS-65, The Philip Carey Mfg. Company, Cincinnati, Ohio 45215. Catalog Data Section Boiler Engineering & Supply Co., Inc. Continental Boiler Division * 5-Manavon St-, Phoenixville, Pa. A HALF CENTURY OF BOILER MANUFACTURING EXPERIENCE 239 Continental Automatic Boilers 15 to 700 HP FOR PROCESSING AND HEATING STEAM ... 15 to 250 PSIG HOT WATER . . . LOW, MEDIUM OR HIGH TEMPERATURE OIL, GAS OR COMBINATION FIRING WITH ON-OFF, LO-HI-LO, OR MODULATING CONTROLS * f I % HP 15 20 25 30 40 50 60 70 BO 100 125 150 175 200 250 300 350 400 500 600 700 Ib/Hr Steam 518 690 863 1035 1380 1725 2070 2415 2760 3450 4313 5175 6040 6900 8625 10350 12075 13800 17250 20700 24150 Output Btv/Hr (1000) EDR 503 670 837 1005 1340 1675 2010 2345 2680 3350 4185 5025 5862 6695 8370 10045 11720 13390 16740 20085 23435 2094... 2790 3490 4185 5560 6975 8370 9765 11160 13955 17445 20935 24425 27915 34895 41875 48825 55830 69790 83750 97635 EDR Water 3350 4465 5585 6695 8930 11165 13395 15625 17860 22330 27915 33500 39080 44665 55830 67000 78136 89330 111665 134000 156215 SPACE-SAVING COMPACTNESS--Simplified 2-Paw design provides optimum bolter capacities in minimum overall dimensions. FUEL-SAVING EFFICIENCY--All Continental Boilers hove a guaranteed minimum efficiency of 80% with any oil or the equivalent with gas fuel "SPINNING GAS" TECHNIQUE Exclusive Continental combustion principle provides high rate of heat transfer through large diameter water cooled furnace, and completes combustion In approximately % of furnace length. BALANCED INTERNAL CIRCULATION--High efficiency ond long serv I ice life are ossured by equal spocing of return tubes concentrically around the centrally-located furnace. Adequate "Downcomer" space along the shell and flow path around the Tumace permits free ond rapid I water movement and unrestricted steam release. NO COSTLY BAFFLES--Continental 2-Pass design dim!nates the need for troublesome interlocking refractory shapes, brickwork and seals al I boiler front or rear. TIME-SAVING ACCESSIBILITY--Hinged front door, burner cover, burner heod ond davited rear door minimize "down** time for inspection and maintenance. Front or rear tube removal is possible. Adequate hand holes and manhole faciltate care of waterside surface. QUIET FORCED DRAFT--Pressurized furnace assures proper placement of combustion air with supply completely controlled at all times. Forced draft eliminates need for costly stock. RELIABLE AUTOMATIC OPERATION--AU Continental units hove the finest industrially-rugged electronic programming, flame monitoring ond safety controls that meet Underwriters laboratories requirements. Con formance with Factory Mutual, Factory Insurance Association, Stole ond local codes arranged where applicable. QUALITY STEAM A specially designed built-in steam separator as sures high purity dry steam. EFFICIENT BURNERS -Mechanical pressure-atomizing oil burner and nozzle-mix gas burner combine high combustion, maximum flexibility and very law maintenance. They hove no moving ports. TUBE END PROTECTION--Where hot combustion gases enter the return tubes. Its# exclusive Continental gas flow impeller has a sleeve which protects the tube entrance from overheating and corrosion. Integral im peller vones direct gases into high velocity spinning flow through entire length of return tube, giving high rate of heat transfer and resulting low stock temperature in one return pass. LOW STACK TEMPERATURE--Flue gases leaving Continental Boilers are guaranteed not to exceed I25*F above boiler water temperatures. This is proof of the high combustion efficiency of the Continental 2-Pass THERMAL SHOCK GUARANTEE--Advanced design--two pou boiler construction eliminates thermal stress in tube sheets--eliminates "thermal shock" (crocking of tube entrance and ligaments). Continental provides a three-year warranty against "thermal shock." We recommend that such warranty be specified for hot water boilers for low, medium ond high temperature heating systems. SINGLE SOURCE RESPONSIBILITY--All Continental Boilers are de signed and built into completely factory-assembled package units at the Boiler Engineering A Supply Co. plant. After rigid testing they are de livered ready for efficient operation. WORLD-WIDE SERVICE--Experienced boiler service men and com petent technicians ore available through authorized Continental dis tributors throughout the United States ond abrood. Ask for Bulletin BE 500.