Document V0eYB1Zpae6jrBgNKbM7zN2p
- B-l -
Monsanto
EXHIBIT B
MONSANTO INDUSTRIAL CHEMICALS CO000 N. Un(b*r|h levlivird St. Louis. Missouri 09100 Pfcenp: (914) 604>tOOO
January 23, 1976
Mr. James Laubscher
Woodson Tenant Laboratories
P. 0. Box 2135
Memphis, Tenn. 38102
'
Dear Mr. Laubscher:
I am writing to summarize the results of the round robin testing of ASTM
0-3306, In which your laboratory participated. Twelve laboretorles agreed to participated in the round robin testing of the water portion of ASTM
0-3304, "Analysis of Environmental Materials for Polychlorinated Biphenyls." To date, results hcve been received from nine of these laboratories. Results
from laboratory K were rejected when It was learned that one critical step of the method was omitted. Laboratory I reported a high background on the river and distilled water blanks relative to the low concentrations ("vl ppb) being analyzed. Their results for the low concentrations were not Included In the tabulation. The sample listed in the first column for laboratory E was obviously contaminated since high values of both Aroclor 1016 and Aroclor 1256 were reported. Theso values were not included In the tabulation.
Current results of the study as of 1/22/76 are attached. The mean and standard deviation have been calculated for each sample. The bottom row lists values expected based on the experimental recoveries of Bellar and Llchtenberg.
Several trends are evident:
1. All mean values Indicate Incomplete recovery.
2. Mean values for PCB's In distilled water agree wall with values predicted from Better and Llchtenberg.
3. Mean values for PCB's In river water are significantly lower then predicted from Bellar and Llchtenberg.
4. Overall accuracy and precision for different laboratories, as
Indicated by the standard deviations, Is low.
.
unil oi
Company
MGNS 093460
Hr. James laubscher
-2-
- B-2
January 23, I376
Host laboratories utilized only the extraction, concentration and measurement portions of the method. Hence the accuracy and precision found in this round
robin testing may be typical of values obtainable with other methods which rely on similar principles. Differences In recoveries for distilled water versus river water (Meramec River, Kirkwood, Ho.) are probably not attrlbut~
able to biodegradation, since the river water samples were preserved with sulfuric acid. Only laboratory L achieved close agreement for the different
waters.
On behalf of ASTN Committee 0-27> thank you for your participation In this
study.
'
Sincerely
st Attachment
HONS 093461
- B-3 ASTH 8-330*1 PRELIMINARY RESULTS
All Concentrations Expressed as pg/t (ppb)
Laboratory A B
' tT 0
1-12 0.8 0.78
-
13-2b 0.5 1.0
------ ^ 25-36 37-b8 b9-60
23.b -- 93
18 15 10
61-72 0.6 0.61
73-8b 6.6 8.8
85-96 97-108
0.3 0.0
0.3b
t
--
109-120 0.0
--
E
27.5* 0.86 19.8
17.7 9.8 0.3b
7.8 0.29
f
t.00 0.82 19.3
20. b 8.93 0.39
b. 87 O.bb
0.09
0.00
6
1.22 1.03 25.3 22.8 12.b .56 7.22 0.6b
.08
.08
H
I
2.78* 2.97* 21.8
9.98 16. b 2.71* b.b2 b.6b* 2.55
l.b3
J
0.67 1.2
18.5* 25.0 9.63 0.69
8.26 0.19
...
--
K
L
CB (1016) Vdded (125<t)
1.23 0.72
1 .b 1.0
19.1 i5.8
16.7 19.b 1.00 16.6 1.32
0.09
0.2
23 23 25.8 1.0
River fclstllle
l.b Water
Water
Blank
Blank
Hein
.95 .88 20.7
Std. Deviation .2b .23
2.6
PCB Added X .7** .98 .70 18.1
18.2 12.0 .60 8.1
5.0 3-9 .22 3.8
16.1 18.1
70 16.1
.50 .39 98
* Not Included In tabulation.
** T. A. Bellar and J. J. LIchtenberg, Water duality Parameters, ASTM STP 573, report 70% recoveries of PCB's In water stored in glass bottles longer than 10 days.