Document RpnrwR5rJVyyRpR93nNn6G27k
KEWANEE TYPE "(T BOUND STEEL BOILER
JACKETED OR UNJACKETED
in the new No. 1733 T\pe "R Round Boiler, for oil or stoker, Kewanee engineers have developed a product that is outstanding in rugged construction, high quality and excellent efficiency. It meets the needs of the smallest home. Rated at 275 sq. ft. actual radiation for steam, and 440 sq. ft. for hot water, it is the smallest size steel boiler made. It's in a class by itself.
The No 1733 possesses all the famous features of Kewanee craftsmanship that have given the Kewanee line the high reputation it bears for dependable perform ance. Its ample, correctly proportioned fire chamber absorbs a high percentage of direct heat from the fire; the Two-Pass Tubes extract usable neat from the remaining hot gases on their way to the chimney: thus an efficiency of practically 80% is attained, resulting in unusual economy and effectiveness.
The Boiler has an attractive steel jacket, with baked enamel crinkle finish in two tones of green It is regularly equipped with an Indirect Hot Water Coil of 55 gallon capacity for storage tank. Or, an Instantaneous Hot Water Coil of 135 gallon capacity, which needs no storage tank, can be furnished at moderate cost.
This newest addition to the complete line of Kewanee Round Steel Boilers, as illustrated and described on the following pages, provides a range of capacities from 275 sq. ft. to 900 sq. ft. of steam radiation.
RATINGS AND DATA
BOILER NUMBER
Oil Stoker
UNJKTD.
ROUND JACKET
1733 1733J
0733
0733J
Ratine Net Load (Actual Radiators piua Domeatic Hot Water Load)
Steam or Vapor.....................................................
....
. . .Sq.Ft.
Hot Water Syatem
..................................
Sq.Ft.
B.t.u. per Hour...............................................
............................
Gallon* of Oil per Hour.
...
See Page A 36-C for ratiugi of larger boiler*.
275 440
M 9
275 440 06
.9
Ftbruory 1, 1940
A 36-A
^AURICAIV
24559
KEWANEE TYPE "IT ROUND STEEL BOILER
NO. 1733 OIL-NO. 0733 STOKER
Cutaway View, No. 1733
18 REASONS FOR "1733" SUPREMACY
1. Safety Vabx.
2. Steam Gauge
3. Gauge Glass aod Trimmings.
4. Compression Gauge Cocks
5. High Steam Space, for Dry Steam.
6. Built-in Kewanee Pure Copper Coil--heats 55 gals, of water 100 in 3 hours--regular equipment. Instan taneous coil heating 135 gals. 100 per hour also available at small extra cost.
7. Connections to Coil, pipe size.
8. Equivalent 6-inch Smoke Pipe Con nection.
9. Two-Pass Tubes--of heavy gauge copper-alloyed steel, absorb maximum heat from hot gases as they pass to chimney Easily accessible for cleaning.
10. Spinner Blades (in oil boilers)-- create spiral flow of hot gases to obtain greater transfer of heat to water, for extra efficiency,
i I. Sturdy Flue and Fire Doors-- thoroughly protected by refractory
linings and gas-tight grooves sealed with asbestos rope gasket.
12. Sight Opening in fire door, with swinging cover.
13. Factory-formed Refractory Block diverts products of combustion into lower tubes and also protects smoke box cover plate.
14. Large, scientifically proportioned fire-box for complete combustion with out waste.
15. Ample Waterways for rapid inter nal circulation and quick steaming.
16. 4-Piece Base, comes bolted together, with convenient cover plate for oil burner or stoker. Front, rear, side or angle firing by turning base.
17. Shell made of heavy steel plate to withstand all strains. One-piece welded construction. All ready to set on base.
18. (Not shown) Has all required tap pings for necessary controls with automatic firing.
Ftbruari 1. 1910
A 36-B
,Y" f K TI A \
KEWANEE TYPE "R" ROUNO STEEL BOILER-
ROUND OR SQUARE JACKETS--UNJACKETED
Round Jacket--Hand Fired Coal
Round Jacket--Oil or Stoker
For 70 years the name Kewanee has meant the best in steel heating boilers. The Type "R'* line of Round Boilers carries on the tradition and embodies all the features of efficiency and dependability assured by Kewanee modern methods of fabrication and high grade materials.
One of the outstanding features of Kewanee Round Boiler design consists of the Two-Pass Tubes, the function of which is tojhold the useful heat in the boiler as long as possible. These tubes are clearly shown in illustration above.
After the direct heating surface absorbs the radiant heat of combustion, the hot gases pass through the lower set of tubes, then back through the upper bank, before reaching the chimney. This gives the gases a longer travel and permits the water to absorb the maximum of the available heat, instead of wasting it up the chimney.
As a result, Kewanee Round Boilers use 80% and more of the heat in the fuel for the actual work of warming the building. Temperature readings show that the gases passing into chimney are at least 1000 degrees cooler than in many heating boilers of similar size, a saving of approximately onc-third.
RATINGS AND DATA
BOILER NUMBER
OIL
STOKER
BITUMINOUS ANTHRACITE HAND-FIRED HAND-FIRED
Unjacketed.................. 1734 1735 1736 1737 0734 0735 0736 734 735 |736 2734 2735 2736
Round Jacket .. . . .. . 1735J 1736J
D73SJ0736J
735J 736J
2735J 2736J
1734M 1735M 1736M 1737M
734MC
2734MC
Short Extension Jacket. 1734MQ 1735MQ 1736MQ
Ixng Extension Jacket 1734MG 1735MG 1736MG 1737MG
...
Rating Net Load
(Actual Radiators plus Hot Water Load] Steam or \ apor. So.Ft.
Hot Water
System........... Sq.Ft. B.t.u. per Hour--I.OOO'i Gals, of Oil per Hour. .
400
MO 96 1.4
540 680 900
860 1000 1440 130 163 216
1.8 2.3 3.0
400 540 680 246
640 860 1090 392 96 130 163 77
320 423 246
512 577 392 98 132 77
320 423
512 677 98 132
Heater Rating-- 100 in 3 Hours.Gak.
750 900
550 750 900 500 700 800 500
700 800
See Page A 36-A for ratings of No. 1733 Boiler.
F5rar t. 19*0
.yu E R ICA X
KEWANEE TYPE "R" ROUND STEEL BOILER
SQUARE JACKETED
*
FLUSH JACKET "M" Oil or Stoker
Nos. 1734M, 1735M. 1736M. 1737M
FLUSH JACKET "MC" Hand-Fired Coal
Nos. 734MC. 2734MC
SHORT EXTENSION JACKET "MO" Oil
Nos. 1734MQ. 1735MQ. 1736MQ
LONG EXTENSION JACKET "MG" Oil
Nos. 1734MC. 1735MG. 1736MG. 1737MG
To keep pace with the modem trend of dressing up basements and converting them into attractive rooms for work or play, we offer a choice of smartly styled and exceptionally neat Square Jackets, in addition to the conventional but goodlooking Round Jacket preferred by many.
These jackets are made of sturdy steel, with a permanent baked-ename! crinkle finish in two tones of green. They make a clean-cut, sightly installation that adds greatly to the appearance and cleanliness of any basement
Regularly furnished in the following types, for boilers as listed under each illustration:
Flush Jacket 'M"--For Oil or Stoker.
Flush Jacket "MC"--For Hand-fired Coal.
Short Extension Jacket "MQ"--For Oil (conceals completely any short-gun or rotary burner).
Long Extension Jacket "MG"--For Oil (conceals completely any burner).
Ftbruary 2, 19^0
A 36-D
American
KEWANEE TYPE "R" ROUND STEEL BOILER
SPECIAL KEWANEE FEATURES
Shell made of heavy steel plate to withstand all strains One-ptece welded construction Ml ready to set on base
Firebox Large and correctly proportioned to permit complete combustion without waste
High Steam space for dry steam
I'wtv-Pass Tubes of extra thick copperalioveJ sceel absorb remaining available heat from hot gases as they pass to chimney Save fuel Easily accessible for cleaning
Spinner Blades in tubes on all oil boilers-- create rotating flow of hot gases through tubes ror greater heat transfer
Ml Doors are ample size and properly in sulated with refractory lining or baffle liner Door castings have gas-tight ground joints or grooves sealed with asbestos rope gasket
Fire surfaces are smooth and self-cleaning
Front, rear, side or angle firing--oil burners and stokers
Tappings for all necessary controls
MI Plate work extra heavy and substantial for long-life
All Boilers equipped with inbuilt coil for Jomestic hot water Not an extra Larger coils and instantaneous flow coils at slight extra cost
Heavy Rocking Grates and Shaker on all coal boilers Assembled so that each grate bar can be removed separately Grates easily replaced if necessary
Inspection Shutter in firedoor of oil fired boilers
Special Kewanee Draft Adjuster (patenced) for accurate draft control, on ail oil and stoker boilers (Not furnished on No 1733 )
Two-Way Smokehood with automatic draft control on coal boilers--for convenience and reduced attention
Quick Pick-up--rapid steaming Reserve capacity above usual rating to care for unusual requirements in sub-zero weather.
DOMESTIC HOT WATER COILS
55 Gal Coil for No. 1733
Instantaneous Flow Coil for No. 1733
65 Gal. Coil for all ocher Boilers
i
FOR AMPLE HOT WATER SUPPLY
All Kewanee Round Boilers are equipped with an inbuilt one-piece Kewanee Pure Copper Coil for domestic hoc water. It is not an extra.
Instantaneous Coil for Larger Boilers
The coil for the new No. 1733 heats 55 gallons of water 100 in three hours, in 212 boiler water. An Instantaneous Flow Coil, for use without storage tank, and heating 135 gallons 100 per hour in 180 water, is available at small extra cost.
On larger Round Boilers coils are furnished as follows: Regular Coil (comes with boiler, not an extra), heats 65 gallons in 3 hours. At small extra cost coils of 95 or 150 gallon capacity are available for all boilers, and 200 gallon capacity on Nos. 1736 and 1737 only. Instantaneous Flow Coils (for use without storage
) tank) are available at moderate cost in capacities: 170 gal.--all boilers except 1733; 210 gal. on Nos. 1735, 1736 and 1737; 250 gal. on Nos. 1736 and 1737 only.
February 1, 1940
A 36-E
RICAN
I
24561
KEWANEE TYPE "R" ROUND STEEL BOILER
SPECIAL FEATURES
SPINNER BLAOES -- These spinner blades are set inside the boiler tubes of all oil boilers to create a rotating How of hot gases, compelling them to make intimate contact with walls of tubes, thus transferring more heat to boiler water Removing these spiral baffles, which takes only a moment, also cleans the flues of accumulated soot.
TWO-WAY DRAFT ADJUSTER -To provide the smooth even control of draft required with oil or stoker boilers, the Kewanee Draft Adjuster (patented) was designed, it is set in the rear smoke outlet casting Accurate draft control is automatically accomplished hy an adjustable weight, which permits the swinging vane to open im mediately at the slightest extra puff. ADJUSTER not supplied ivuh No 1733 Boiler
SPECIFICATIONS AND MEASUREMENTS-
| iBOILER NUMBER
OIL
STOKER
^ANTHRACITE OR
BITUMINOUS
HAND-FIRED
Unjacketed Round Jacket Flush Jacket . . Short Extension Jkt. Long Extension Jkt. .
1733 1734 -1735 173b 1737
1733J i
1735J 1736J
1734M 1735M I736M *
1734MQ 1735MQ1736MQ
! 0733 0734 0735 0736 734 |735 736
0733J
O735J0736J
735J 736J
734MC1. ;'
1734MG 1735MG 1736MG 1737MG
Keating Surface.... Firebox \olume Grate Area Average Firebox Ht.
Su.Ft. Cu.Ft
Sq.Ft. In.
Boiler Shell Diameter In
Boiler Shell Height
In
Boiler Shell I naide Diam. In i
Smoke Outlet Diam.. Chimney Site.. Chimney Height . .
. In.1
In 1 Ft .
16 2 1
2 8 11
17 (
24 44 22
21 ! 23*4 40 17 ! 20
6I 7
8x8 8x8 30 ' 30
i 32 64
1
i 24
27*4 43 23
9 8x12
30
! 40 ! 89
26
30h 47*4 26
9 8x12 35
; 33 , 16 2 ' 24 < 32 j 40
1 8 9 | 2 2 J3 7 i 5 4 1 7 4
124i 26
i 17 22
1 | 26
j 30H , 21 48J, l
| 26 | 17
23*4 27UI30H 42*4 43 1 47** 20 23 126
9 10x10
40
6 79 9 8x8 8x8 8x12 8x12
30 30 30 35
24 j 32 1 40 I3 7
!2.2 [2 t
22 24 | 26
23H 27*430*4 42*4 143 20 123 >
7 1919 8x8 8x128x12 30 j 30 35
Outlet and Return Siie Safety Valve Sixe.
In In
u
H
Height All Jackets. --In Width All Square Jackets In Length--Flush Jacket In* Length--Short Ext. Jkt. In Length--Long Ext. Jkt. In
54
54* 33
2"H 45 59*4
1
55'4 36 36 5Oh 65
4
59h 39h 39*4 54 68h
i
61 39*4 54
88 H
3 44
H H1
1
4 44 H1
54
........ ..........
54**1 55** 59*4 54*4 33 36 39*4 33 27W36 54 27*4 45 50*4 54
59*4 65 68*4 .. ..
55**59*4
Jacket Clearance in Front
Flush Jacket.
.In.
Short Extension
. In.
Base Front to Firebox
Boiler Base Diameter Water Liae Water Line with Coils
In. '
.In. 23 In. 46 In. 46
Vi I7h 32 3`4
26** 44 44
3 17*4 32
29*4 44 45
3h 18 32H VA
32H 46 47
18H
32*4 4H
32H 49 49
H 3 3*4 UVi 17*4 18 32 32 32*4
3!i H 4H
J*
23 26*4 29?* 32H 26** 32** 85 46 14 44 46 44 44 46 46 44 45 47 44 45 47
Smoke Outlet Ht., End In. 30
Smoke Outlet Ht., Top In.
Smoke Out. to Blr. Cen In. 14
Water Heater
Connection Height
In. 43
Rear Clearance
from Jacket.
In. 2H
Floor to Boiler Door
Opening................
In. 21
Clear Opening
I4l
in Base Front.......... .. In. 12H
43** 20
<1H
15
19*4 lOJii
15
48 24
44*4
12*4
20 lOx
ISH
50 25*4
46*4
13*4
20** lOx
ISH
... 50 - 438* 48 25*4 14 20 24
39*4 42*4 44*4 50 44H 49 51 25*4 20 24*4 25**
46*4 43 4LH 44M 46H 41H H 46*4
13H
2*4 15 12*4 13*4 12 16 16
20*4 lOx
15*4
21 19*4 20 20*4 19*4 20 204* i4K* \m tOx lOx llx lOx lOx 12*4 >15 ISH ISH 13 15J4(15*4
Outside Surface to Cover, Unjktd.... Sq.Ft. 17
24
33
40
47
17 24 33 40 24 33 40
Shippin^Weight,
Lfaa. 600 800 920 1130 1400 600 800 920 1130 880 10401280
"Same data applies to both Anthracite and Bituminous; Anthracite Boiltr Numbers are 2734, 2735 and 2736.
YI H1CA\
A 36-F
February /, 1940