Document Rpk7no0xgJB6pEydq88xRBKpn
St. Louis - Ceneral Offices May 11, 1970
H. S. BERGEN J. E. SPR1NGGATE
W. B. Pspsgeorge
Attached hereto are copies of charts I uaed in the preaeatation with the CMC this morning.
The CMC gave its approval for us to implement the plan as outlined on the two sheets marked "PRESENT PLAN".
We are required to report to the CMC should we make any major deviation from these plans and we are also required to make a progress report probably around the 1st of August. Would you please go ahead and take the necessary action within your Individual business groups and keep me advised of progress.
Att.
JOHN MASON
TRAN 085281
HARTOLDMON0027140
v
>
COST OP RAPID PHASE-OUT ALL CHLORINATED BIPHENYLS EXCEPT DIELECTRICS
1970
LOSS IN SALES
-
LOSS IN CROSS PROFIT
$ 5.4 M $ 2.6 M
IN ADDITION COGS WOULD INCREASE GIVING TOTAL LOSS IN GROSS PROFIT OF - $ 2.73 M.
1971
LOSS IN SALES
- $ 12 M
TOTAL LOSS IN GROSS PROFIT - $ 6.1 M
PLUS POSSIBLE WRITE-OFF OF SOME $ 2.6 M KRUMMRXCH AROCLOR FACILITIES.
1.
TRAN 085282
HARTOLDMON0027141
OBJECTIVE TO, MAINTAIN A PROFITABLE BUSINESS SERVING THE NEEDS OF FUNCTIONAL FLUIDS USERS AND THE CARBONLESS DUPLICATING PAPER INDUSTRY WHILST MINIMIZING THE ESCAPE OF NON-BIODEGRADASLE CM a - BIPHENYLS INTO THE ENVIRONMENT.
COMPANY . CONFIDENTIAL
TRAN 085283
HARTOLDMON0027142
3.
ACTION TO ACHIEVE OBJECTIVES
1) MARKET NON-BIODECRADABLE CHLORINATED BIPHENYLS ONLY FOR CLOSED SYSTEM APPLICATIONS WHERE CONTROL IS POSSIBLE.
2) PHASE OUT OF ALL NON"CONTROLLABLE APPLICATIONS . REPLACING WITH BIODEGRADABLE CHLORINATED BIPHENYLS OR OTHER SATISFACTORY PRODUCTS.
COMPANY CONFIDENTIAL
TRAN 085284
HARTOLDMON0027143
TRAN 0 8 5 2 8 5
pen1 PRODUCTION
g*.oo
THE
CLOSED
LOOP
REGENERATION &'
RECYCLE v'
PCB'a USAGE
INCINERATE
ADSORPTION FROM
AIR & WATER
//
4
/
BIODEGRADATION
HARTOLDMON0027144
5.
DO WE HAVE THE CAPABILITY TO CLOSE THE LOOP ?
COMPANY CONFIDENTIAL
TRAN 085286
HARTOLDMON0027145
6.
BIODEGRADATION
1) GOOD PROGRESS AT BOTH RUABON AND ST. LOUIS.
2) . LOWER CHLORINATED ISOMERS RESPONDING WELL, BUT 5 & 6 CHLORINE ISOMERS EITHER NOT RESPONDING OR VERY SLOW.
3) CRITICAL PRODUCT IS 1242, CONTAINS SOME 50 ISOMERS
-- GOOD RESPONSE ON 2, 3, & SOME 4 CHLORINE
ISOMERS.
.
4) WORK IN HAND ON FRACTIONATED 1242 GOOD PROGRESS TO DATE.
COMPANY CONFIDENTIAL
TRAN 085287
HARTOLDMON0027146
I
FICURE 2 Semi-Continuous Activated Sludge Modegradat ion
TRAN 085288 /
HARTOLDMON0027147
FIGURE 3
Aroclor 1254
Raw Hllk Extract
Ik to
at i
/
/
/
/
J
TRAN 0 8 5 2 6 9
HARTOLDMON0027148
FIGURE 1
HARTOLDMON0027149
REPLACEMENT
PRODUCTS
7.
1) 1242B SHOWS GOOD PROPERTIES AS CAPACITOR DIELECTRIC NOW MAKING 500 GALS. AT DAYTON FOR CUSTOMER TRIALS. ALSO WORKING ON 1230B.
2) GOOD PROGRESS ON PHOSPHATE ESTER REPLACEMENTS FOR HYDRAULIC FLUID APPLICATIONS. -- TCP -- CDP -- TBP -- NONYL PHENYL/COMYL PHENYL DIPHENYL PHOSPHATE.
3) HEAT TRANSFER FLUIDS -- USING MAINLY ESTABLISHED
PRODUCTS, E.G. HB-40 -- EXAMINING POSSIBLE ENTRY
INTO DIPHENYL OXIDE PRODUCTION EITHER OWN PROCESS OR
LICENSING.
TRAN 085291
HARTOLDMON0027150
8.
TOXICITY
1) NO CHANCE SINCE LAST REPORT - HAVE DISCUSSED RESULTS WITH DR. BURGER, EXECUTIVE OFFICE OF THE PRESIDENT.
2) WE HAVE ANALYZED AROCLORS 1248 AND 1254 FOR OCTOCHLORO DIBENZO p-DIOXIN -- NONE FOUND.
3) CENTRAL INSTITUTE FOR NUTRITION AND FOOD RESEARCH,
ZEIST, HOLLAND -- EXAMINED BAYER,PRODELAC AND MONSANTO
CHLORINATED BIPHENYLS FOR DIBENZO FURANS -- NONE
FOUND IN MONSANTO MATERIAL.
,
COMPANY CONFIDENTIAL
TRAN 085292
HARTOLDMON0027151
INCINERATION
1) SUCCESSFUL TRIAL AT JOHN ZINC CO., TULSA. 1242, 1260, 1254 DESTROYED AT 2000 F. -- OFF GAS HC1. ENGINEERING WORK NOW IN HAND TO BUILD SUITABLE INCINERATOR. ESTIMATED COST $250,000 M.
2) INTEND TO CARRY OUT FURTHER TRIALS ON STILL
BOTTOMS.
'
3) INCINERATOR PROBABLY LOCATED AT KRUMMUCH.
COMPANY CONFIDENTIAL
TRAN 085293
HARTOLDMON0027152
5,000 ppb
CONTROL OF PLANT EMISSIONS
3,500
ppb
3,000
ppb
11.
COMPANY CONFIDENTIAL
73 > 2
o
00
VJ>
ro >
ANNISTON
*
5 lb3./day '
KRUMMRICH
200 lbs./day
NEWPORT - 0.5 lbs.
HARTOLDMON0027153
12.
CLOSING
THE
LOOP
FOR
INDIVIDUAL
BUSINESSES.
COMPANY
confidential
TRAN 085295
HARTOLDMON0027154
13.
TRANSFORMER & CAPACITOR DIELECTRICS 1) RESPONSIBLE INDUSTRIES USING 1254 AND 1242. 2) FIRE RESISTANCE EXTREMELY IMPORTANT. 3) COLLECTION AND RETURN OF SPENT AND ARCED FLUID. 4) REGENERATION AND RECYCLE. 5) TRIALS PLANNED FOR 1242B AND 1230B IF SATISFACTORY. 6) LABELLING OF ASKAREL TRANSFORMERS.
c
TRAN 005296
HARTOLDMON0027155
14.
HEAT TRANSFER FLUIDS
1) EDUCATION OF USERS WHERE FIRE RESISTANCE IS OBLIGATORY * MAJOR INDUSTRIAL CORPORATIONS -- E.G. GOODYEAR AND CHEMICAL COMPANIES.
2) PHASE OUT OF ALL FOOD APPLICATIONS -- LETTERS WILL BE SENT OUT MAY 15th -- NO SALES AFTER AUGUST 15th -- WILL COLLECT AND DESTROY OLD FLUID.
3) INSTITUTION OF REGULAR COLLECTION REGENERATION OR INCINERATION SERVICE.
4) PHASING IN NEW PRODUCTS WHERE CONTROL NOT POSSIBLE.
COMPANY CONFIDENTIAL
TRAN 085297
HARTOLDMON0027156
HYDRAULIC
FLUIDS
1) RECOGNIZE THAT CONTROL OF SPILLAGE AND PUMP LEAKAGE MAKES THE USE OF NON-BIODEGRADABLE CHLORINATED BIPHENYLS UNDESIRABLE.
2) ALREADY REFORMULATED PYDRAUL 625, ACWG, 280 and F9 -- REPLACEMENT COMPLETE BY AUGUST 1
3) OTHER PRODUCTS IN INTERIM STAGES (E.G. PYDRAUL AC FORMULATION ON COMPRESSOR TEST AT JFQ).
4) AIM TO COMPLETE 90X PHASE-OUT BY'DECEMBER, 1970.
COMPANY CONFIDENTIAL
TRAN 08529H
HARTOLDMON0027157
16.
1) U.K. HAS APPROVED HB-40, NOW PLACED REGULAR ORDERS -- EXPECT COMPLETE PHASE"OUT BY let JULY.
2) U.S. RUNNING TRIALS ON M.I.B.P., EXPECT DECISION
22od MAY -- PRELIMINARY XNTERIUM PRODUCTION
OF 40 M POUNDS PER MONTH TARGETED FOR 30th AUGUST
-- PLANNING FULL SCALE PLANT 10 M LBS. PER
ANNUM ON STREAM END JANUARY 1971 -- ESTIMATED
NFC $1 - 1.2 M.
'
TRAN 085299
HARTOLDMON0027158
17.
PLASTICIZER & MISCELLANEOUS APPLICATIONS
1) DISTRIBUTORS ALREADY ADVISED NO MORE SALES AFTER 30th AUGUST. (200 CUSTOMERS)
)2 LETTERS TO 661 CUSTOMERS WILL BE SENT OUT 27th MAY
ADVISING NO MORE SALES AFTER 30th AUGUST -- DISPOSAL INSTRUCTIONS WILL BE GIVEN.
3) IN CONTACT WITH U.S.D.A. THROUGH AG DIVISION ON
SILO PAINT PROBLEM.
.
-
4) BY 30th AUGUST ALL BUSINESS IN THIS AREA WILL BE PHASED OUT.
TRAN 065300
HARTOLDMON0027159
PRESENT
PLAN
1) TERMINATE SALES OF ALL NON-BIODEGRADABLE CHLORINATED BIPHENYLS TO NON-CONTROLLABLE END USES. COMPLETE - AUGUST 30th 1970.
2) DISCONTINUE SALE OF AROCLOR 1242 TO NCR AND REPUCE WITH HI-40 IN U.K., AND MIBP IN U.S.A. COMPLETE - U.K. -- JULY let, 1970 COMPLETE - U.S. -- JANUARY 30eh, 1971
3) CLOSE THE LOOP ON HEAT TRANSFER APPLICATIONS WHERE P/R IS VITAL AND REPUCI WITH ALTERNATES IN OTHER CASES. COMPLETE - DECEMBER 30th, 1970
TRAN 085301
HARTOLDMON0027160
,,,
w
4) REPLACE ALL NON-BIODECRADABIE^ CHLORINATED BIPHENYLS
IN HYDRAULIC APPLICATIONS.
COMPLETE 2OX - AUGUST 1st, 1970 " 4OX - NOVEMBER lit, 1970. ' 1001 - DECEMBER 30th, 1970
5) CLOSE THE LOOP ON ALL NON-BIODEGRADABLE CHLORINATED BIPHENYLS IN TRANSFORMER APPLICATIONS.
COMPLETE - AUGUST lit, 1970
6) CLOSE THE LOOP ON CAPACITORS AS FAR AS POSSIBLE AND
REPLACE 1242 WITH 1242B.
'
COMPLETE - DECEMBER 31st, 1970
TRAN 085302
HARTOLDMON0027161
NEV' CAPITAL NEEDED
HE-40 EXPANSION - ANNISTON SANTCWAX X REFINING - ANNISTON N3-40 CAPACITY - NEWPORT NIB? CAPACITY - ANNISTON.?
- $ 275,000 - $ 250,000 - $ 1,000,000 - $ 1,200,000
CUMYL/NONYL PHENYL DIPHENYL PHOSPHATE JFQ
-$
575,000
INCINERATOR/RECLAIMING EQUIPMENT
- $ 2S5,000
TOTAL MEW FIXED CAPITAL
- $ 3,585,000
cow^S
COHF'0
TRAN 085303
HARTOLDMON0027162
PROFITABILITY FORECAST
1971
'
SALES
C. ?.
.
N.I.A. T. CROSS INVESTMENT
EXISTING PC LOR BUSINESS
$ 22.0, K $ 8.5 >1 $ 2.9 M $ 25.4 Jl
R.O.I.
11.57.
AROCLCRS L ne;: r.-.cx-:'
5 20.0 M $ S.o M
$ 2.7 M $ 29.0 F:
9.57;
COMPANY. CONFIDENTIAL
TRAN 085304
HARTOLDMON0027163