Document Rpk7no0xgJB6pEydq88xRBKpn

St. Louis - Ceneral Offices May 11, 1970 H. S. BERGEN J. E. SPR1NGGATE W. B. Pspsgeorge Attached hereto are copies of charts I uaed in the preaeatation with the CMC this morning. The CMC gave its approval for us to implement the plan as outlined on the two sheets marked "PRESENT PLAN". We are required to report to the CMC should we make any major deviation from these plans and we are also required to make a progress report probably around the 1st of August. Would you please go ahead and take the necessary action within your Individual business groups and keep me advised of progress. Att. JOHN MASON TRAN 085281 HARTOLDMON0027140 v > COST OP RAPID PHASE-OUT ALL CHLORINATED BIPHENYLS EXCEPT DIELECTRICS 1970 LOSS IN SALES - LOSS IN CROSS PROFIT $ 5.4 M $ 2.6 M IN ADDITION COGS WOULD INCREASE GIVING TOTAL LOSS IN GROSS PROFIT OF - $ 2.73 M. 1971 LOSS IN SALES - $ 12 M TOTAL LOSS IN GROSS PROFIT - $ 6.1 M PLUS POSSIBLE WRITE-OFF OF SOME $ 2.6 M KRUMMRXCH AROCLOR FACILITIES. 1. TRAN 085282 HARTOLDMON0027141 OBJECTIVE TO, MAINTAIN A PROFITABLE BUSINESS SERVING THE NEEDS OF FUNCTIONAL FLUIDS USERS AND THE CARBONLESS DUPLICATING PAPER INDUSTRY WHILST MINIMIZING THE ESCAPE OF NON-BIODEGRADASLE CM a - BIPHENYLS INTO THE ENVIRONMENT. COMPANY . CONFIDENTIAL TRAN 085283 HARTOLDMON0027142 3. ACTION TO ACHIEVE OBJECTIVES 1) MARKET NON-BIODECRADABLE CHLORINATED BIPHENYLS ONLY FOR CLOSED SYSTEM APPLICATIONS WHERE CONTROL IS POSSIBLE. 2) PHASE OUT OF ALL NON"CONTROLLABLE APPLICATIONS . REPLACING WITH BIODEGRADABLE CHLORINATED BIPHENYLS OR OTHER SATISFACTORY PRODUCTS. COMPANY CONFIDENTIAL TRAN 085284 HARTOLDMON0027143 TRAN 0 8 5 2 8 5 pen1 PRODUCTION g*.oo THE CLOSED LOOP REGENERATION &' RECYCLE v' PCB'a USAGE INCINERATE ADSORPTION FROM AIR & WATER // 4 / BIODEGRADATION HARTOLDMON0027144 5. DO WE HAVE THE CAPABILITY TO CLOSE THE LOOP ? COMPANY CONFIDENTIAL TRAN 085286 HARTOLDMON0027145 6. BIODEGRADATION 1) GOOD PROGRESS AT BOTH RUABON AND ST. LOUIS. 2) . LOWER CHLORINATED ISOMERS RESPONDING WELL, BUT 5 & 6 CHLORINE ISOMERS EITHER NOT RESPONDING OR VERY SLOW. 3) CRITICAL PRODUCT IS 1242, CONTAINS SOME 50 ISOMERS -- GOOD RESPONSE ON 2, 3, & SOME 4 CHLORINE ISOMERS. . 4) WORK IN HAND ON FRACTIONATED 1242 GOOD PROGRESS TO DATE. COMPANY CONFIDENTIAL TRAN 085287 HARTOLDMON0027146 I FICURE 2 Semi-Continuous Activated Sludge Modegradat ion TRAN 085288 / HARTOLDMON0027147 FIGURE 3 Aroclor 1254 Raw Hllk Extract Ik to at i / / / / J TRAN 0 8 5 2 6 9 HARTOLDMON0027148 FIGURE 1 HARTOLDMON0027149 REPLACEMENT PRODUCTS 7. 1) 1242B SHOWS GOOD PROPERTIES AS CAPACITOR DIELECTRIC NOW MAKING 500 GALS. AT DAYTON FOR CUSTOMER TRIALS. ALSO WORKING ON 1230B. 2) GOOD PROGRESS ON PHOSPHATE ESTER REPLACEMENTS FOR HYDRAULIC FLUID APPLICATIONS. -- TCP -- CDP -- TBP -- NONYL PHENYL/COMYL PHENYL DIPHENYL PHOSPHATE. 3) HEAT TRANSFER FLUIDS -- USING MAINLY ESTABLISHED PRODUCTS, E.G. HB-40 -- EXAMINING POSSIBLE ENTRY INTO DIPHENYL OXIDE PRODUCTION EITHER OWN PROCESS OR LICENSING. TRAN 085291 HARTOLDMON0027150 8. TOXICITY 1) NO CHANCE SINCE LAST REPORT - HAVE DISCUSSED RESULTS WITH DR. BURGER, EXECUTIVE OFFICE OF THE PRESIDENT. 2) WE HAVE ANALYZED AROCLORS 1248 AND 1254 FOR OCTOCHLORO DIBENZO p-DIOXIN -- NONE FOUND. 3) CENTRAL INSTITUTE FOR NUTRITION AND FOOD RESEARCH, ZEIST, HOLLAND -- EXAMINED BAYER,PRODELAC AND MONSANTO CHLORINATED BIPHENYLS FOR DIBENZO FURANS -- NONE FOUND IN MONSANTO MATERIAL. , COMPANY CONFIDENTIAL TRAN 085292 HARTOLDMON0027151 INCINERATION 1) SUCCESSFUL TRIAL AT JOHN ZINC CO., TULSA. 1242, 1260, 1254 DESTROYED AT 2000 F. -- OFF GAS HC1. ENGINEERING WORK NOW IN HAND TO BUILD SUITABLE INCINERATOR. ESTIMATED COST $250,000 M. 2) INTEND TO CARRY OUT FURTHER TRIALS ON STILL BOTTOMS. ' 3) INCINERATOR PROBABLY LOCATED AT KRUMMUCH. COMPANY CONFIDENTIAL TRAN 085293 HARTOLDMON0027152 5,000 ppb CONTROL OF PLANT EMISSIONS 3,500 ppb 3,000 ppb 11. COMPANY CONFIDENTIAL 73 > 2 o 00 VJ> ro > ANNISTON * 5 lb3./day ' KRUMMRICH 200 lbs./day NEWPORT - 0.5 lbs. HARTOLDMON0027153 12. CLOSING THE LOOP FOR INDIVIDUAL BUSINESSES. COMPANY confidential TRAN 085295 HARTOLDMON0027154 13. TRANSFORMER & CAPACITOR DIELECTRICS 1) RESPONSIBLE INDUSTRIES USING 1254 AND 1242. 2) FIRE RESISTANCE EXTREMELY IMPORTANT. 3) COLLECTION AND RETURN OF SPENT AND ARCED FLUID. 4) REGENERATION AND RECYCLE. 5) TRIALS PLANNED FOR 1242B AND 1230B IF SATISFACTORY. 6) LABELLING OF ASKAREL TRANSFORMERS. c TRAN 005296 HARTOLDMON0027155 14. HEAT TRANSFER FLUIDS 1) EDUCATION OF USERS WHERE FIRE RESISTANCE IS OBLIGATORY * MAJOR INDUSTRIAL CORPORATIONS -- E.G. GOODYEAR AND CHEMICAL COMPANIES. 2) PHASE OUT OF ALL FOOD APPLICATIONS -- LETTERS WILL BE SENT OUT MAY 15th -- NO SALES AFTER AUGUST 15th -- WILL COLLECT AND DESTROY OLD FLUID. 3) INSTITUTION OF REGULAR COLLECTION REGENERATION OR INCINERATION SERVICE. 4) PHASING IN NEW PRODUCTS WHERE CONTROL NOT POSSIBLE. COMPANY CONFIDENTIAL TRAN 085297 HARTOLDMON0027156 HYDRAULIC FLUIDS 1) RECOGNIZE THAT CONTROL OF SPILLAGE AND PUMP LEAKAGE MAKES THE USE OF NON-BIODEGRADABLE CHLORINATED BIPHENYLS UNDESIRABLE. 2) ALREADY REFORMULATED PYDRAUL 625, ACWG, 280 and F9 -- REPLACEMENT COMPLETE BY AUGUST 1 3) OTHER PRODUCTS IN INTERIM STAGES (E.G. PYDRAUL AC FORMULATION ON COMPRESSOR TEST AT JFQ). 4) AIM TO COMPLETE 90X PHASE-OUT BY'DECEMBER, 1970. COMPANY CONFIDENTIAL TRAN 08529H HARTOLDMON0027157 16. 1) U.K. HAS APPROVED HB-40, NOW PLACED REGULAR ORDERS -- EXPECT COMPLETE PHASE"OUT BY let JULY. 2) U.S. RUNNING TRIALS ON M.I.B.P., EXPECT DECISION 22od MAY -- PRELIMINARY XNTERIUM PRODUCTION OF 40 M POUNDS PER MONTH TARGETED FOR 30th AUGUST -- PLANNING FULL SCALE PLANT 10 M LBS. PER ANNUM ON STREAM END JANUARY 1971 -- ESTIMATED NFC $1 - 1.2 M. ' TRAN 085299 HARTOLDMON0027158 17. PLASTICIZER & MISCELLANEOUS APPLICATIONS 1) DISTRIBUTORS ALREADY ADVISED NO MORE SALES AFTER 30th AUGUST. (200 CUSTOMERS) )2 LETTERS TO 661 CUSTOMERS WILL BE SENT OUT 27th MAY ADVISING NO MORE SALES AFTER 30th AUGUST -- DISPOSAL INSTRUCTIONS WILL BE GIVEN. 3) IN CONTACT WITH U.S.D.A. THROUGH AG DIVISION ON SILO PAINT PROBLEM. . - 4) BY 30th AUGUST ALL BUSINESS IN THIS AREA WILL BE PHASED OUT. TRAN 065300 HARTOLDMON0027159 PRESENT PLAN 1) TERMINATE SALES OF ALL NON-BIODEGRADABLE CHLORINATED BIPHENYLS TO NON-CONTROLLABLE END USES. COMPLETE - AUGUST 30th 1970. 2) DISCONTINUE SALE OF AROCLOR 1242 TO NCR AND REPUCE WITH HI-40 IN U.K., AND MIBP IN U.S.A. COMPLETE - U.K. -- JULY let, 1970 COMPLETE - U.S. -- JANUARY 30eh, 1971 3) CLOSE THE LOOP ON HEAT TRANSFER APPLICATIONS WHERE P/R IS VITAL AND REPUCI WITH ALTERNATES IN OTHER CASES. COMPLETE - DECEMBER 30th, 1970 TRAN 085301 HARTOLDMON0027160 ,,, w 4) REPLACE ALL NON-BIODECRADABIE^ CHLORINATED BIPHENYLS IN HYDRAULIC APPLICATIONS. COMPLETE 2OX - AUGUST 1st, 1970 " 4OX - NOVEMBER lit, 1970. ' 1001 - DECEMBER 30th, 1970 5) CLOSE THE LOOP ON ALL NON-BIODEGRADABLE CHLORINATED BIPHENYLS IN TRANSFORMER APPLICATIONS. COMPLETE - AUGUST lit, 1970 6) CLOSE THE LOOP ON CAPACITORS AS FAR AS POSSIBLE AND REPLACE 1242 WITH 1242B. ' COMPLETE - DECEMBER 31st, 1970 TRAN 085302 HARTOLDMON0027161 NEV' CAPITAL NEEDED HE-40 EXPANSION - ANNISTON SANTCWAX X REFINING - ANNISTON N3-40 CAPACITY - NEWPORT NIB? CAPACITY - ANNISTON.? - $ 275,000 - $ 250,000 - $ 1,000,000 - $ 1,200,000 CUMYL/NONYL PHENYL DIPHENYL PHOSPHATE JFQ -$ 575,000 INCINERATOR/RECLAIMING EQUIPMENT - $ 2S5,000 TOTAL MEW FIXED CAPITAL - $ 3,585,000 cow^S COHF'0 TRAN 085303 HARTOLDMON0027162 PROFITABILITY FORECAST 1971 ' SALES C. ?. . N.I.A. T. CROSS INVESTMENT EXISTING PC LOR BUSINESS $ 22.0, K $ 8.5 >1 $ 2.9 M $ 25.4 Jl R.O.I. 11.57. AROCLCRS L ne;: r.-.cx-:' 5 20.0 M $ S.o M $ 2.7 M $ 29.0 F: 9.57; COMPANY. CONFIDENTIAL TRAN 085304 HARTOLDMON0027163