ABD00313391 Interoffice Communication To A. H. Sather From J. V. Uptain Date January 23, 1980 Subject VCM DOSIMETRY - SAMPLING FREQUENCY (L&/K A As requested, I have reviewed the results of VCM dosimetry during the last half of 1979 (See Table I) to determine what, if any, changes need to be made in sampling frequencies. Based on these results and the probable exposure potentials, I recommend the sampling frequency scheme in Table II. Note that "quarterly" sampling would be discontinued and the number of samples per year reduced by 310 (22%). c: Plant Manager, Department Heads