Document RpReVyM5VbxpavdqB6ZX65Rrn

* mxm Mtu orrwi koppers COMPANY, INC #^ TO, JaOr. q. f. P'Alello. hamf SVoT**eT .^iSMSOfPirtiSi. umct--------Proposed Thermal Insulation Manual -,>cns rcv.rAiw.iNC. i aaiwv- 4 MAR 2 8 K3 Production Departneut i CeolIMT Pittsburgh. Pa. I i *<L -Etrsh 77i 1???. i[*P~lCTYO NU I Thor* Id enclosed herewith on* copy of a draft of a propoaod Thermal Insulation Manual. The purpoaa of this distribution in draft font to to permit tin* to review and study this draft and prepare ecansnts and suggestions for rtvlalon for conaldaratlon at a sooting of tha Toohnical Standards Coanitteo to bo called the latter part of April. 1952. . Xt la planned in tho completed manual to elaborate on certain eeetiona of thia draft, particularly Section T on Application of Material*, and Section VII which will include a number of sketches of approved sethods of application, and aketchea of insulation accessories. Also, the information in Tab "A" will be expanded to include the characteristics of all principal materials. Tho information contained in Tab "A" outlining tho characteristics, advantages, and disadvantages of certain products should bo treated as confidential. Thia Information has been obtained from various sources, and is subject to further verification, which will be accomplished before placing the annual in operation. Additional copies of this preliminary manual are available for distribution within your Division as you desire. Additional eoplss may be secured by memorandum or telephone call to L. J. Dillon, Extension 684. Enclosure 0 Fred Denlg SC-BE-00765 ft?J;-' 2 w$ I8$fe Si m -vjr-5 v W| i;; ' ;,:>-^V* vtu^ci :V`jfASf^S 34 y.^h t.*V .VV^.S<K\:tif seas ': `M"*# ^w /'S-V-ft? ^11 ...v :.^m CSifI K0PP'ft3 caw, INC. PROPOSPP THERMAL INSULATION HANUAI, `.vk..*5 A \" V'?| :l$h APRIL 1952 n 2S222 The importance of Thermal Insulation in Industrial Plants is Just beginning to receive the consideration it deserves. In the past, thermal insulation has been thought of as anything that could be applied to a heated surfae*. The question of obtaining the material with characteristics that would as nearly as possible match the require ments for the specific job has been neglected in many cases. Tot. this means the difference between the successful Job that will fulfill the requirements and wear well in service, and the hit or miss Job that does not meet the operating conditions and in short period of time deteriorates so that replacement at considerable expense is necessary. In these days of high cost of labor and material, we cannot afford to put the wrong type of insulation on a job; we cannot afford to use improper accessories; we cannot afford to use the wrong type of weatherproofing; and last but not least, ve cannot afford to use the wrong method of application. How are we going about to select the best insulation for the specific job, especially in these days when there are many types of insulating materials on the market, and new ones being developed every year? How are we going to know that when we do select material that the particular lot of the material which we happen to receive on the Job will have the same characteristics as those advertised in the manufacturer'a catalog? How do we know that the method of application of the insulating material on the piping, tank, or equipment, is a method that will properly secure the material under the operating conditions which prevail. For use as an aid in resolving the above important problems, and also some of lesser importance, is the purpose of this manual. i m ?: IV SECTION I GENERAL INFORMATION A. GENERAL Thermal Insulation may be defined as those materials or combination of materials employed to offer resistance to the flow of heat under ordinary conditions. In its broadest sense, the insulating materials are used to control heat by delivering or preserving the correct amount of heat at the right place and at the proper tine, and also for keeping heat away from where it is not wanted. B. DEFINITIONS In discussing Heat Insulation, it is important that we define the components which make up the finished item: ' 1. Insulating Material is defined as the material which retards ' the transfer of the heat. . 2. Insulating Cement is usually a dry mixture of insulating material which when mixed with a suitable proportion of water applied as a plastic mass and dried in place offers resistance to the flow of heat. 3. Lagging is defined as the protective covering or Jacket placed over the actual insulating materials. - A. Weatherproofing is the term cownonly referred to the compound which is applied over the insulating material or the insulating cement to protect the materials from one or a combination of hazards such as moisture, corrosion, acids, and fire. 5. Insulation accessories include bands, hangers, studs, reinforcing metals and similar appliances used in the application of the insulation. 6. Insulation is defined as the composite covering or the finished product in place. 0. THEKKAL CHARACTERISTICS Thermal characteristics cover the behavior of heat flow through the insulating material* Thermal conductivity is usually expressed as the k value. It is defined as the thermal conductivity expressed in Btu in. per hr. per sq. ft. per F. The heat transmitted through a material is influenced to a considerable degree by the density and structure of the material, and to a lesser degree by the temperature at time of testing and whether any moisture is in the material. Therefore, in order to accurately evaluate the k value of different materials, it is necessary to know the thickness and density of the material tested, the mean temperature at time of test, and whether the material was thor oughly dry before testing. Manufacturing literature, unfortunately, seldom gives this information. Furthermore, there has unfortunately crept into the literature on insulation too much emphasis on the k value. The relative importance of thermal conductivity depends upon the specific Job. It may be that the operating conditions demand that a mavimim rate of heat loss be specified. Or, it may be that certain processes may require that a definite amount of heat be lost, but not to exceed a given figure. In such cases the thermal conductivity characteristic is of great importance. On the other hand, it may be that a reasonable amount of heat loss will be accepted and certain physical characteristics would be the determining factor selection, A typical case such as this would be the top of a tank where the heat control was not too exact and where it might be necessary for operating personnel to walk over the insulation. Here flexural and compressive strength of the material would be more important than the k value. The principal thermal characteristics are as followsi 1. Conductivity 2. Temperature Range -- maximus and minimum 3. Expansion and Contraction 4. Resistance to Flame B. PHTSTCAL CHARACTERISTICS It may be atated, as a general rule, that from a users viewpoint at least one or more physical characteristics will be an important factor in the selection process. The physical characteristics must meet the requirements of transportation and handling and also of the operating conditions. Some insulation applications are supported by lagging, while in other applications the insulation must not only support itself but also the outer finish. More often than the reverse, the material must be capable of withstanding a certain amount of mechanical abuse, such as being walked on or resisting heavy leaning objects. In such applications suitable high flexural and compressive strengths aro highly desirable. It may be that the insulation is subjected to repeated shocks, and in such case, a high Impact value would be Indicated. The principal physical characteristics are as follows: 1. Density 2. Dimensional Accuracy 3* Resistance to Moisture A. Resistance to Abrasion 5 Hardness - surface 6. Flexural Strength 7. Resistance to Compression S. Impact Strength 9. Temperature Effect on Strength 10. Linear Shrinkage at Maximum Temperature F. CHEMICAL qiATtACTFSISTICS The chemical characteristics of insulating materials have not been stressed to any great extent In the past by manufacturers of Insula tion. These characteristics are, however, of considerable Importance, especially in chemical plants and similar installations. It is altogether possible that some fires of undetermined origin in chemical plants have been the result of the reaction between outside finishing materials and certain chr.ieal fumes. It is also a well-known fact that certain materials constantly subjected to alkalinity will deteriorate very fast. For these reasons it is important that the operating conditions in various parts of certain plants be carefully determined, it is entirely possible that in one part of a plant where a certain type of fumes are prevalent, some insulations might not stand up. Whereas, they would be perfectly satis factory in another part of the plant. The following are the important chtmical characteristics! 1. Alkalinity Resistance 2. Acid Resistance 3. Flash Point A. Auto Ignition Point 0. ELECTRICAL CHARACTERISTICS It Is very rarely that electrical characteristics will be the governing factor in the selection of insulating material. It is only in procedures where the process heating is performed by electrical means that those characteristics need be considered. The important electrical characteristics are! 1. Resistance to Electrical Current 2, Galvanic Action H. SELECTION OF INSULATING MATERIALS 1. General After the operating conditions for the spoclfie job have been oarefully reviewed and set forth, the important problem confronting the user is then in the selection of the most suitable material that will meet these requirements. It is amazing the amount of improper insulating material that has been placed on piping and equipment. One of the most common causes of such failure is that of the use of material not suitable for the high temperature to which it is actually subjected. Other failures have been sustained due to moisture absorptive materials being used where moisture was permitted to reach the insulation either during the applica tion or in the subsequent operation of the equipment. Still other failures have been caused by materials failing to withstand the physical abuse to which it was subjected. 2. Temrerature Ranres As an aid in the selection of insulating materials, the products of the principal insulation manufacturing companies have been catalogued according to tho following temporature ranges: Low temperature Medium temperature High temperature - flOF and below from 90F to 600F 600F and above 3. Characteristics of Acceptable Products The company, trade name of product, together with thermal, physical, and chemical charaotcristlos of acceptable products ore catalogued and tabulated in Tab "A". J. Selection of Suitable Materials A method of selection utilizing an analysis sheet, together with explanatory information, is contained in Tab "Bn. - 5- SECTION III FINISH3S AND ACCESSORIES A. INSVLATP.'O CaiHOT There aro a number of Insulating cements on the market, some of which are furnished for their insulating properties, and some are supplied merely to act as finished surfaces 'Then insulating cement is used in connection with insulation of Industrial equipment, it is coercion practice to apply two layers of the cement. First, a mesh wire netting or a glass fabric is usually placed directly on the insulating material. The first layer is then applied over this reinforcing material, usually about 1/2" thick, left rough, and allowed to dry thoroughly. The second layer is then applied also about 1/2" thick and trowelled to a smooth surface. In connection with the application of insulating cement, it is of the utmost importance that the esent have good bonding qualities. A msaber of contents are on tho market which do not have good adhesive qualities; and serious difficulties have teen experienced after tho equipment has been placed in service, We should, therefore, be sure that tho cement to be usod has good bonding qualities, first to the Insulating material over which it is applied, and second between the two layers of the content Itself. B. LAGGING Lagging protects the Insulating materials from mechanical abuse and from abrasion due to Inherent working conditions. Depending upon the severity of those conditions, logging varies from galvanised iron Jackets to textile er paper covering, '.here used Indoors, the lagging strengthens a surface and provides a suitable finish for painting. *hen used outdoors, the Jacket also provides strength and a painting surface, and In addition oftan provides protection from spillage of process fluids which might seriously damage the insulating material. Also on outdoor piping, espec ially near tho connection to vessels or tanks, the lagging protects the Insulation from blowing steam from traps. C. ACCESSORIES It is Important that tho accessories usod in the application of the insulation be correctly designed, and most important that they be of the proper materials. With many materials now being on the critical list, it la necessary that substitutions be used. However, these substituted mater ials should be carefully scrutinized t.o be sure that they are capable of resisting the hazards involved such as corrosion, fire hazards, and similar agents. . It is recommended that banding wire and wire mesh be monel metal and that banding straps and holding clips be stainless steel. -6- ) SECTION IV VftATHERraOOriNS A. OPrSRAL Weatherproofing, as the name implies, is the protecting cost on the outside of the Insulation. Li the Insulation Industry, there are two common types of weatherproofing very predominately used. These are cut back bltunastle materials and emulsified asphalts. The tyue of weather proofing to use will, of course, depend on the type of the Insulating material which is to be protected and also from the operating conditions where the insulation is to be used. One type of weatherproofing used over Insulating materials which are susceptible to moisture might be selected for this characteristic, whereas, a condition existing which demands the protective coating bo Incombustible might enure the selection of the other type. It is, of course, important that the weatherproofing coating be well bonded to the insulating material. It is also important that it be adapt able for spraying. Also, the acid resistance, alkaline resistance, and certain physical characteristics such as tensile strength are important. The temperature range of the piping or equipment may also influence the selection. In the low temperature range, any moisture is driven inward through the insulation by heat. In this case, it is important the surface of the eqt:ipoent or piping be protected arainst corrosion as any moisture will be driven by the hot outside air through the Insulation, and the moisture will collect on the outside surface of the piping or equipment. In toaneratures of medium range, any moisture in the insulation is driven outward or inward, depending on temperature of atmosphere in relation to that of piping or equipment. This breathing action will for a msaber of months of the year depend on the time of day, being exerted inward during the day time and outward at night,. Corrosion may occur at both the surface of the piping or equipment and at the outside of the Insulating material provided that mesh wire or other reinforcing materials have been used in the application. There have been many insulation failures due to corrosion of the mesh wire or other reinforcing materials, and there are on record failures of vessels in Industrial Diant* which caused plant shutdowns due to corrosion of the steel under the insulating materials. Finally, in the high temperature range, the heat of the piping or equipment drives any moistubs outward. Hero, while moisture in the insulation must be considered, it is nofso important as in tho lower limits. Frctt these considerations, it can be seen that the vapor sealing qualities of the weatherproofing are also Important. At certain temp eratures with certain types of insulation and certain types of weather proofing, it is possible that any moisture in thu insulating materials will te moro or less scaled within. Here the insulation conditions wculd be similar to a person trying to keep warm wearing a wet overcoat. It is possible that on certain construction when conditions are Just right that the pressure might build up sufficient to disrupt the weather proofing. Unfortunately, we do not have a material at present on the market so that entrapped moisture could be expelled through the surface of the material to the atmosphere but which would not permit moisture fro* entering from the outside. In other words, a type similar to a flap valve. Where the insulating material is subjected to extraordinarily heavy physical abuse, it may call for a metal Jacket. V.hlle this method is more costly as far as first cost is concerned, in some particular cases it has proved most economical in the long run. Also, for indoor Installa tion, where the insulation is cowrtd with a canvas Jacket, a good grade of fire resistant paint is very effective. - 0- ,XTaS.'-- - * ----- SECTION V APPLICATION A. C^.HtAL The effectiveness of an insulation depends to a largo extent on the manner in which it is applied. Generally speaking, an Insulating material with a high k value properly applied will be sore effective than a material with a low k value incorrectly applied. As a matter of fact, the principal insulating materials on the market today vary only slightly with regard to thermal conductivity. There is, however, a great difference in the effectiveness of the manner in which they are applied and also In the manner as to how they stand up in service. This, indeed, may very well be the crux of the matter in determining the selection of an insulating material. B. ECUirM??.T l&enever possible-, the type of Insulating material and method of application on new equlcraont should be determined before purchase. Studs, angle iron, clips, and other devices for fastening the insulation which require welding should be completed before shipment. This is especially important when the vessel or equipment is stress relieved. c. Esum irr m "ick The following are the ten cardinal rules for the application of insulation. Strict adherence to these rules will orevtnt a great deal of faulty insulation bolng installed on piping and equipment. Piping, vessels, and other oncratlng equipment shall be inspected and tested for leaks and mechanical defects. All repairs shall be made before applying insulation. Protection of metal surfaces from corrosion is Important. The same care with regards to preparation of metal surfaces over which insulation is to be placed should be exercised as in the case of preparation of metal for painting. During installation. It Is important that the insulation doos not absorb any moisture. Contractors must be warned not to leave any insulation in process in an exposed condition, -fticn it is not possible to weatherproof each days work, it should be carefully crotected before leaving the Job. If moisture gets into the insulating material and is sealed in by the weatherproofing, it may be extremely hard to get out, and serious corrosion both to the equipment and the reinforcing material mas* result. -9- V* For a good job. It Is necessary that the dimensions of tho insulating tutorial be uniform. Tolerances to plus or minus me eighth of an inch are comsonly required. Moisture is tho arch enemy of insulation. Moisture usually gets into insulation from tho top by not having proper overhang of roofing; from the bottom by a wicking action of the moisture which has penetrated tho bottom flashing and at right angle junctures where filets ore not used in the weatherproofing and the insulation cracks at tho junction. Insulation is only as good as the fastening which holds it on. Be sure that the method of fastening is proper and that not too much weight of insulating material is permitted between supports. This is particularly true of tank installations, both vortical and horizontal. 'Whenever possible to obtain, fastenings should be oif tho non-corrosive type. Any insulation which might be subject to mechanical abuse or scorehing shall be provided with a suitable protection such as sheet metal. Wherever chemical spills may occur over insulation, a hood, should be provided to protect the insulation from damage. Firu is still public enemy number one in Industrial Plants. In hazardous locations where spread of fire could cause serious damage, the weatherproofing over the insulation should be fire resistant. Where the insulation is subjected to fUaes, it is very important that the proper kind of material be selected. Some materials art acid resistant but rapidly deteriorate in alkaline conditions and vice versa. In the same plant, ono Insulation nay stand up in one part of the plant, whereas, it would soon go to pieces if used in another location. SECTION' VI TESTS A. GTERAL One of the principal difficulties experience! in the insulation field is'connected with tests. Unfortunately, there is no standard method of testing from an Industry wide standpoint. The Mineral Wool Institute has recorded with the National Bureau of Standards a Caanorcinl Standard for testing and reporting Mineral Wool products. The Magnesia Manufacturers Association is working with the Amorican Society for Testing Materials, looking toward a similar arrangement. While these two associations are attempting to work out standard procedures and tests within their own respective associations, each is different and there is nothing on an Industry wide basis. Also, a standardized method of testing is lacking. It is a well known fact that one testing laboratory will obtain different results than Another laboratory on the same material, caused by varying testing conditions or equipment. In view of these circumstances, it is important that the reports of the tests be carefully evaluated. B. SPECIFIC The following are the tests usually required for insulation. However, when the insulation must meet certain abnormal conditions, then, of course, tests for such conditions must be specified. 1. Handluability. This test is designed to insure that the material can be transported without damage and can be handled as a unit. 2. Thickness. It is customary to specify both a minus and a maximwa tolerance, and usually hold to tolerance of plus or minus 1/8 inch. 3. Length and width. For batts and blocks those dimensions arc specified, and usually held to tolerance of plus or minus 1/8 inch. A. Density, It Is co.-rsson practice to specify density as the maximum number of pounds per cubic foot. 5. Thermal Conductivity. The k value is specified for certain temperatures within the rango of the insulating material Involved. The density of the material for a given k value should be stated. 6. Fire Resistance. The specific type test is usually specified tdten this factor is desired. - 11 - 7. Modulus of Rupture. Usually specified is m<w<mnn pounds per square inch. 8. Moisture Absorption. The corison practice is to specify the maximum percent Absorption by weight, and sometimes also by volume. 9. Resistance to Abrasion. Usually specified as maximum percent loss in weight during a specified time of testing. 10. Linear Shrinkage. Exposure to soaking heat at manufacturer's recommended temperature limit for 24 hours after which a measurement is made for shrinkage. 11. Resistance) to corrosion, acid3, ilkalines, etc. Specified according to desired time of testing. C. TEST PS^CMUIlES 1. General. Mint to test, whsrc to test, and how to test aro usually perplexing problems for Industrial Plants. This is especially so when the plant does not have a laboratory or when the laboratory facilities are limited. 2. v~hat to test. Every insulation Product arriving at a plant should receive some kind of a test. It has been argued that the values for the various characteristics as listed ' in the Manufacturers Catalog should be accepted as the statement of re'put.-.blc firms. That, however, is not the question. It often happens in manufacturing operations that due to certain defects in the raw materials us..d or defects in processing, a particular lot ia not up to standard. This, for one reason or anoth.r, may not be- considered by the plant as cause for scrapping the particular lot In question. There is no way to be sure that the purchaser gets value received except by test either at point of origin or after delivery. 3. Where to test. The best place to test is at tho point of origin before shipping. Unfortunately, this is seldom possible when dealing with Insulation Materials. Vc then have to conduct the tests At the plant, and this should bo accomplished as soon after delivery as possible. 12 iffir. Sli '* How to teat. How to test insulating materials received at plant presents a considerable problem. None of our plants, and for that matter, very few plants are equipped to make such tests as thermal conductivity, compression strength, shrinkage, and similar tests requiring very special equipment. All plants are, however, by using a little Ingenuity, able to make simple tests, and fortunately these simple tests give much valuable information. It is therefore recommended that the following tost procedures be adopted for plant tests of Insulating material. For plants equipped to make additional tests of specified characteristics, that Is highly desirable. a. Handleablllty. This test Is designed to measure how well the material transports and how it stands up as a unit. The American Society for Testing Materials have at present under consideration a testing machine which will measure this factor. However, for practical considerations, a machine is not necessary. When the shipment is received at the plant, a representative sample should be inspected and any damage noted. For example, if 100 boxes of material mads up the shipment, 10 boxes should be opened and examined. Each unit should be sufficiently coherent to transport without breakage or damage. If a unit does not transport well under ordinary shipping conditions, it is good evidence that difficulty may also be expected when it comes to the application. If there is over five percent damage of the sample tested, it is sufficient cause for rejection. Breakage or damage is defined as of such severity as to render the unit either difficult to apply or substantial decrease in efficiency. For example, a slight corner of a block chipped off might be accepted, tfcereas, a crack extending through the block would be rejected, b. Dimensional Accuracy. This test should also be performed on a representative sample. For a shipment of $000 pieces, 10 pieces selected at random shevie oo taken as ample. This proportion should apply for all sizes of shipments except the sample should never be less than 5 pieces. (1) Blocks. For Blocks, the length, breadth, and thick ness should be carefully measured by best available plant methods. Each block making up the sample should be mcaeurod and the averago taken. These measurements should be checked against the manufacturer's specified dimensions. A tolerance of plus or minus one eighth inch is peraissable. ... mg-#,- J. r.r.bt.'S)' ' v : V ; it S*,.v - 13 - * #! (2) Pipe Insulation. For pipo insulation, the a me procedure should be followed in testing for length, inside diameter end thickness of the insulating material. A tolerance of plus or minus one eighth inch is permissible. (3) Blankets. The length and width of each unit shall not be less than the specified dimensions. Measurement of length and width shall be on the insulating material and not on the facing. The thickness of each unit shall b as specified with a minus toler ance of one eighth inch and a plus tolerance of one quarter inch. (it) Batts. The length and width of each emit shall be not lens than t.io specified dimensions. The measured thickness of each unit shall be as specified with a minimum tolerance of one eighth inch. (5) iteKctlona. Two percent rejects of the sample taken is sufficient ciu3o for rejection. If the sample falls to conform to this requirement, a second samole similar to tho first shall be taken and tlisted. The results of the re-tests shall bo averaged with the results of the original test, and if this average is greater than two percent, the shipment will be rejected. Density. Density is a very important characteristic of an insulating material, and fortunately this te3t can readily be made at Plant level. Density has a direct influence on thermal conductivity, and also on tho compression and flexural strength of a material. Unfor tunately, in the trad*; literature, this important char acteristic is often expressed in a loose manner -- for ex mplo, aoc.e manufacturers express tho density of their product with a range of 6 pounds per eu. ft. without stating at which density the thermal conductivity and some of the other characteristics were measured. Density should be expressed as the maximal pounds per cu. ft., and tho relating characteristics such as thermal conduc tivity and compression and flexural strength should be based on this maximum figure. Density is expressed os the weight per cu, ft. 'jid may be calculated as follows! . weight per cu. ft. s W x 1728 ADC VT S weight of test specimen A - length of test piece in inches B - width of test piece in inches C - thickness of test piece in inches Rejection - anything over the maxima specified figure should be rejected. .-5 !!!!& * r. yy\ f : Vh- - ; . - sfr-Ci:: : -: = : . . pfer:,' K ' t-'.s: , e: ' SECTION VII SKETCHES OF a PLICATION METHODS aND ACCESSORIES SKETCHES It la proposed to Incorporate In this section a number of sketches shoving anproved mothoda of aopllcatlon of the various forma of insulated materials and accessories* Aiso will be Included here tables shovdng optlsua thickness of piping and block insulation, and other uscfll tables* 15 - SECTION VIII MAINTENANCE a. c,o?*m 1. Periodic Inspection with corresponding maintenance Is almost unheard of In the field of Insulation. Plants that stake inspections at prescribed intervals and designate the Jots that are to be repaired before they deteriorate to the point of causing excessive danago are few and far between. Yet it is a simple procedure that can save many thousands of dollars in the course of a year in a medium sized plant. In the first placo, it saves on the magnitude of th<> Job of repair, and in the second place it saves on shut down time of cquif*ient and loss of heat due to defective insulation. If ;*ou walk through almost any Industrial Plant, you will find insulation that has buon off piping, valves, and even some equipment for as long as a year. It seuas as though the maintenance force never gets caught up with tho rcnalr of insulation. Ttds immediately brings up another point. It may bn that this condition Is caused by using the wrong type of Insulation for tho Job in question. Unfortunately, most plants do not maintain historical records. It is not possible to determine with any degree of accuracy the typo of insulation on a run of piping or a piece of equipment, the date it was installed, ar.d a record of repairs which were necessary. If more of this kind of information was available, it would go a long way to avoid repeating the same mistakes. Such records are main tained by some plants in the form of "Historical Records". Thoy have proven their worth in establishing valuable information in connection with future plant maintenance. 2, Inspection. It is recommended that all piping insulation and all Insulated equipment be inspect id twice each year. It has been found that the bent periods for making this inspection are during tho months of Avgust and Kerch. The repairs necessary after the August inspection can be effected in order to place the insulation In goed ope rating condition for tho winter season and the March inspection will indicate tho repairs necess ary as the result of the usually more severe operating conditions during tho winter months. 3, Historical Record. It is recommended that all principal runs of piping insulation and all insulated equipment be listed on a "Historical Keoord Card." These records should include the insulated materials used, date installed, cost, and a record of all repairs made, and recommended Inspection dates. This record will not only be valuable in determining how the Insulating material stands up in service but will serve as an aid to insure Inspection at specified dates. - 16 - "I !; ; ;' :i! : j . ;r i: ; 1 : i -i j :7V m laid r? .V-.rv THERMAL INrKUTION MATERIALS L. W. CHARACTERISTICS 85% MAGNESIA Resistance to enter Fair STD. UNIBESTOS Excellent FI8ERGU3 AEROCOR Excellent FOAMGLAS Excellent KAXLO Good MINERAL WOOL BLOCX Excellent Composition Advantages Disadvantages 85% Magnesia 10% Long Fiber Inorganic Binder Long Fiber asbestos with binder ______ Handles and transports well. Fairly easy to apply. I Handles well. Excellent resist ance to water and weather. Fine glass fibers wLth binder Pure glass Calcium silica Mineral containing separate blended with fibers with sealed cells asbestos fibers binder Very flexible. High compressive High coopressiv Flexible. Fibers will not strength. Pract strength. Cuts MU stand break down. Light ically vapor proof. clean. Ea3y to expansion weight. Excellent Does not depend on handle. and con for piping and weatherproofing for traction valves. Eliminates vapor barrier. weU. pipe size stockage Incombustible. Hard to obtain Dimensions not tight fit. Fairly always exact, soft. Poor making application resistance to watey somewhat diffi and poor bond cult. surface. No physical strength Must be protected from physical abuse Requires close Not suitable fitting and must for bridging. be protected Non-flexible. against abrasion. Soft. WiU not resist mechanical abuse. Notet This is la sample sheet only Similar sheets w 11 be added to covei all principal products. At this tise this irtforaatdon should be kept n Company channels and not shown to mar ufacturcrs or their (agents. While me st of the information shorn is ac urate, some is sub, ect to further check Similar information will be fumlch ed with resoect ko selection of wea< .herproofing and In: u1ation Accessories Compression and FI xural strength represents strengths at which material failed. In Ph val%,e, 7.0 represents ncjutrality. Below th:. point indicatet acidity, and above thpt point, alkalinity Other values su< th as Impact, Resistance to .braslon, and Shrinkage will tje added . when thhlijns sample 6hect is rivisod. wm A METHOD FOR THE SELECTION OF IB3UUTIHO MaTHT.IA^ A. GBiaAL . Tho determination of tho insulating material most suitable for a specific Job is a very important as well as difficult procedure. One of the reasons why it is difficult is the fact that the literature of the various manufacturers seldom lists all of tho characteristics which are important in meeting tho operating requirements for the Jab. It is, therefore, necessary to obtain this additional Information cither by special inquiry from the manufacturers or by information obtained as the result of tests. P. PR0CT2CRKS In order to assist the various activities of tho Company which are responsible for selecting tho most suitable insulating material for tho specific Job, the following procedure is recommended -a 1. Using the "Analysis Sheet" (copy attached), the operating temperature rsngo of the piping or equipment is entered. 2. The next step is to determine from "Tab A" all of tho products tdiich moet the operating temperature requirements and enter the names of these products in the proper columns. 3. Next, the characteristics for the various products are obtained from "Tab A" and listed in the proper columns. A. Each characteristic on the "Analysis Sheet" is then carefully considered with respect to the importance for the particular Job being considered, and the rating for each characteristic is entered In the " Import vco Factor" column. In this rating, tho designation "A" for "Absolutely necessary", "B" for "Oasirablc", and "C" for "Unimportant" will bo used. C. VALUATION ( The final stop is to ovaluato tho ctiaractcristies of the various products in consideration of the actual requirements for tho Job. Xn this evaluation it ia doeirod to call attention to tho fact that there is no one perfect insulation, and not often will this systun automatically select the one perfect material for the job. It will, however, eliminate undcslrablo products and will often indicate two or more products which are about the same with respect to balancing the operating requirements against the characteristics of the products. ~hun this condition occurs, then "Cost in Place" of tho insulation will probably be the governing factor. w*m. *! !! : !i ! ; .r:; 0- ;