Document RpOzrM60D04g2mjM6rJ0aYq97
r. a . Dollar' and J. J. Lichtvnberg'
Some Factors Affecting the Recovery of Polychlorinated Biphenyls (PCB's) from Water and Bottom Samples
REFERENCE: Bellur. T. A. and Lielucuberg, J. J . "Some Factors Affecting (lie Re
covery of Polychlorinated Biphenyls (PCB's) from Water and Bottom Sample*/' Water
Quality I'aruwtvrs. AS I'M STt1 57.?. American Society for Testing and Materials, 1975,
pp. 2(Xi-2l9.
'
ABSTRACT: During studies on analytical method** for PCIfs in water and bottom sam ples, variable recoveries from dosed samples and apparent decreasing recoveries with the age of the sample were observed. Losses from dosed river waters as high as 10 per cent in one day amt greater than 90 percent in one week were common. Recoveries from bottom samples varied widely with the sample pveUeatmcnt and the method of extrac tion. In an effort to define some of (he laetors affecting the recovery of PCB's from water, (he following parameters and conditions were studied: sample container, extremes of pH. aging under ambient conditions, and several preservation techniques. Several methods of sample preparation and extraction of bottom samples were studied. Environ mentally contaminated water and lake bottom samples and dosed natural samples were studied.
The separatory funnel liquid-liquid extraction method wns found to be the most efficient fvn the extraction of PCB's from natural waters. The air'dried. moisture-added soxlilet extraction procedure proved to be the most efficient for recovery of PBC's front environmentally contaminated lake bottom samples. Formaldehyde was found to be effective for preserving PCB's in dosed natural waters for at least two weeks.
KEY WORDS: water quality, water pollution, pesticides, toxicity, recovery, aquatic ani mals. polychlorinated biphenyls (PCB's)
Polychlorinated biphenyls (PCB's) have been recognized for several years as ubiquitous environmental pollutants. These complex mixtures of variably chlorinated biphenyls have occurred in nearly every environmental media [1.2].1 Their presence in water, sediment, biota, fish, birds, ant) animals have been reported [J-5|. While the PCB's are reported to be less toxic than the chlorinated hydrocarbon pesticides, acute toxic effects to aquatic life have been demonstrated (T 6]. Since they do exhibit acute
* * hcniisi and chief. Organic Analyses Section, respectively. Methods Development :iml Duality Assurance Research Laboratory. National Environmental Research Center, U S. Hnviromuentni Protection Agency. Cincinnati. Ohio 95268.
' I he iulic number'* in brackets refer to the list of references appended to this paper.
206
DSW 033873
STLCOPCB40'
BELLAR AND LICMTFNBGRG ON POLYCHLORINATED BIPHENYLS 207
toxic effects and, like the chlorinated pesticides, they arc biologically magnified 17), it is important to mainlnin surveillance of the PCB levels occurring in the environment.
The PCB's are chemically similar to many of the organochlorine pesticides; therefore, the same analytical procedures are applied to both. Being complex mixtures, the PCB's present a serious interference problem when determining many pesticides. Therefore, special separation and cleanup procedures arc required for analyses when both occur in a given sample. Much work has been published on the separation and the determinative aspects of the analysis 18-10}. However, little has been reported on factors that might affect the extraction and recovery of PCB's from environmental samples.
During our studies on water, we noted variable recoveries from dosed samples and an apparent decreasing recovery with the age of the sample. In an effort to define some of the factors affecting the recovery, the following parameters were investigated: the sample container, extremes of pH, aging under ambient conditions, and several preservation techniques. Liquid-liquid extraction and extraction with urethane foam plugs were studied. During our studies on recovery of PCB's from bottom samples, several methods for preparation and extraction of bottom samples were compared. We were particularly interested in the newer column extraction procedures since they appear to be becoming very popular. Environ mentally contaminated samples and dosed natural samples were studied.
Experimental
Apparatus--The high frequency mechanical dispersion instrument used in one phase of the bottom sample extraction study was (lie Super Dispax Tissumizer, Model STD 182N (Tckmar Company. Cincinnati, Ohio).1
Reapeuts--Reference Standard PCB's Aroclors 1242, 1254, 1260. and 1016 (Monsanto Chemical Company. St. Louis. Mo.) prepared in acetone solution, formaldehyde--27% aqueous solution.
Procedure--The samples were collected in l-qt to 6-gal glass containers at various times over a period of one year.
The primary liquid-liquid extraction procedure employed for water samples was that recommended by the U.S. Environmental Protection Agency (EPA) for organochlorine pesticides [//]. In addition, the semi automatic magnetic stirring (Vortex) system of Kawahara ct al 1/2) was icsted. The urethane foam procedure for extraction of PCB's from water was that published by Gesscr et al (/_?). A modification of Gcsscr's procedure, that of soaking the foam plugs in the sample with occasional shaking, was also tested.
'Mention ot` products and mamil'aclvirers is lor identification only and does not imply vudorscmcul by the Methods Development and Duality Assurance Research Laboratory of \\\< U.S. Ianiummcittul Protection Ajjemry.
DSW 033874
208 WATER QUALITY PARAMETERS
Several methods for extraction of bottom materials were investigated. The soxhlct extraction procedure of Breidenbnch et al [I4\, column elution procedures of Hesselberg and Johnson [/5J and Southeast environ mental Research Laboratory [16], (he high frequency dispersion procedure of Johnson and Starr [17], the mechanical shaking procedure of Goerlilz and Elrown |/| and Shell Chemical Company [79], and the blender extraction method of Muth [20] were tested.
All bottom sample extracts were cleaned up in the same manner. The standard Florisit column procedure [//] and the semi-micro silica ge! procedure of Leoni [9] were employed. When necessary, elemental sulfur was removed from the extracts using mercury according to the method of Gocrlit/. and l aw [2l\, Table I lists (he conditions for preparation and extraction of bottom samples.
t AHU: Met luxl
SuxhitM
Shake 1
Shake It UlcMikT Column l
Column II
Hl|*h frequency dis persion
pnn't'ilurvs fr.vfn/ far rcroirrv ofPCH's ffvw bononi sump/vs.
Prcliminj ry
Dry Mat Water
lixlriKting
Red
Drying
ter. % Added
Solvent
|/T|
|/V|
|/l U//| W5)
1/61
1/71
air dry at room
temporal ure. grind--mortar and pestle air dry at room temperature, grind--mortar ami pestle none
' os > `>5
Na,SO, added
partial air dry a(
room temperature, mix with Na,SO, amt grind partial air dry at
room temperature, mix with Na,SO< and grind none
-- 70 -50-70
10% hexane-acetone (1:11
slurry hexane-isopropyl alcohol (3:1)
none none none
acetone with hexane added later
acetonitrile-acetone (1:1)
hexane
none hexane-acetone (1:1)
none acetone
Dosing Procedures--Water Samples (880 ml) in 1-qt sample bottles
were individually dosed by pipetting the PCB's in acetone solution (1
pg/ml) and shaking vigorously to achieve uniform mixing.
.
Bottom Samples--Approximately 400 g of an air dried sediment (98.7
percent dry matter) was ground with a mortar and pestle and passed
through a 20 mesh screen. The sediment was then placed in a 1-qt wide
mouth glass bottle. Distilled water (200 ml) was added and mixed to form
a slurry. Aroclor 1242 (50.0 pg) and Aroclor 1254 (50.0 pg) in 1 pg/pl
SW 033875
BELLAR AND LICHTENBERG ON POLYCHLORINATED BIPHENYLS 209
acetone solution was added to the slurry with continual mixing. The bottle was sealed and allowed to equilibrate for 20 h with occasional shaking. Appropriate aliquots of the dosed sample were taken and treated as required by the extraction methods to be tested. The high frequency dispersion device, Column II, and soxhlet extraction were selected for testing recovery on dosed bottom samples.
Quantitation Techniques--Two methods were used to reduce the electron capture gas chromatographic data:
(<j) When a dosed or environmentally occurring PCB equivalent to or closely resembling a standard Aroclor was present, a simple calcula tion was made by summing all the peak heights of the unknown and comparing it to the sum of the peak heights of the reference Aroclor.
(b) When mixtures of PCB's, not representing a single Aroclor were present, the method of Webb [10] was used to determine the PCB concentrations and the most likely Aroclor represented.
All results for bottom samples were calcualtcd on a dry weight basis. T he dry weight was obtained by oven drying an aliquot of (he sample at approximately 105C overnight.
Gas chromatography and mass spectrometry techniques were used to confirm the identity of the PCB's in the environmentally contaminated samples.
Kcsults and Discussion
Water Samples Initial studies to determine the cause of low and variable recoveries of
l'CB's from dosed natural waters centered around (he bottle cap liners. Tellon lined caps which are used routinely arc considered the best choice when collecting samples for organic analysis. It was thought that the Teflon may be sorbing some of the PCB's. However, no PCB's were recovered from Tellon liners after soaking in hexane for 1 It. Sub sequently, a comparison of recoveries using Tellon lined caps and aluminum lined caps was made. T he samples were stored under ambient conditions in the laboratory, up to 11 days. Figure 1 shows that (here is a tendency toward higher recoveries when using aluminum lined caps. In each case, samples stored with aluminum cap liners yielded greater recoveries than those stored with Tellon lined caps.
Sample Preservation Figure 2 shows the results of aging on recovery of PCB's from dosed
natural river waters. Samples held at ambient conditions in the light showed variable and often low recoveries with a general decrease in
DSW 033876
STLCOPCB4017838
210 WATER QUALITY PARAMETERS
l-TG. I--kfleet of cap liner on recovery of PCll s front dosed river water {dose of I #i$ per ><ttnpie).
2- i.'lf cct of 'acini' on recovery ttf PCH s front dosed river water at amhient tempera ture. preserved versus nott`preserved {dose of I per sample).
DSW 033877 STLCOPCB4017839
percent recovery
BELLAR AND LICHTENBERG ON POLYCHLORINATED BIPHENYLS 211
recovery will) lime. Recoveries ranged from 102 percent in a low of 67 percent over a period of 15 days. The recoveries from samples preserved with formaldehyde were quantitative over the time period, averaging 105 percent and ranging from 92 to 116 percent. Figure 3 depicts ty pica I losses of the isomers of Aroclor 1016 that occur after aging a dosed sample for 15 days. The greater losses occur in the isomers that contain three or fewer chlorine atoms. The greatest losses occur in peaks 37 and 40 which represent PCB's containing three chlorine atoms. All natural water samples tested showed a trend toward reduced recovery with the age of the sample. The rate of loss appeared to be affected by the variation in physical, chemical, and biological characteristics of the samples.
Table 2 compares the recoveries of Aroclor 1016 obtained from dosed river waters that have been preserved with formaldehyde up to 15 days to the recoveries obtained at lime zero (<8 h after dosing). A statistical
DSW 033878
I'lG. 3--I'.U'i'tron cupturv gas chromato^ratn of nfvrvm'v .uanthtrd and m-orrm/ Arnclnr
1016-
STLCOPCB4017840
212 WATER QUALITY PARAMETERS
I AHI 1-. 2--Kfct/vcry t>( Arnclur 10/6 /rom rtVcr uf urm' zvro versus sunipU'S //rrjcnr*/ ilnil ttxc(f (dose. / Mg Minipic).
Recovery. %
l ime Zero "
109 107 107
08
IIP 11(> 11 1
107
Mc:m No, of samples .Standard deviation Variance Coefficient of variation Blank value (average) Corrected mean
II w 111
too
<w 105
105.4 M (,.l 40.4
6.0 (1.0 99.4
Preserved `
92 107 1 10 111 109 9.1 1 10 111 104 105 IDH 111 l>5
105.5 IT 7.0 57.8
7.2
6.0 99. S
MTime zero <8 h after dosing. ^Preserved with formaldehyde (15 nil of 37%
solution).
comparison of the data shows very good agreement between the time zero and preserved samples.
The pH of the sample had no effect on the extraction efficiency from dosed samples over the range of 2.7 to 10.5. That is, the average recovery at time zero for the pH levels listed in Table 3 was quantitative, 'fhe accuracy and precision was essentially equivalent to that obtained for the untreated samples shown in Table 2. The limited data obtained suggest an apparent effect on the recovery as the sample ages at pH 5.3 and 7.3. Recoveries at these pH levels decreased with time although the decrease was not as great as noted in other studies. Recoveries at pH 2.7. K.H, and 10.5 were near quantitative throughout the time period studied.
The effect of storing samples at ambient temperatures in the light, dark, and under refrigeration was studied. The results are listed in Fig. -1 and compared to results obtained for samples preserved with formal dehyde. Samples stored in the dark yielded higher recoveries throughout the period of study than those stored in the light. Refrigerated samples gave slightly better recoveries than those stored at ambient temperature iu
DSW 033879
BELLAR AND LICHTENBERG ON POLYCHLORINATED BIPHENYLS 213
TABLE 3--Recovery of Aroclor 1016 front dosed river water al various pf-f levels (dose. I sample).
I'll
2.7 2.7 2.7
5.3 5.3 5.3
7.3 7.3 7.3
8.8 8.8 8.8
10.5 10.5 10.5
A^r. days
2 6 14
2 6 14
2 t> 14
2 6 14
2 b 14
Recovery.
98 102 91
107 89 86
109 87 84
107 106 95
107 105 100
NoTlC-- Hlank value = . 7%. Pay Zero value (mean recovery)
107%.
033880
|'}(;. 4--Recovery of A roclor lOlf) front dosed river wafer when stored of o/nhient tent fh raiure (in light and the dark), under refrigeration, a/ul preserved with fonnaltlehyde (dose
I Mp l"'r
STLCOPCB4017842
214 WATER QUALITY PARAMETERS
11 ip dink. However. the Irani of decreasing recovery was evident under all three conditions. Samples preserved with formaldehyde gave the highest and least variable recoveries and showed no decreasing trend in recovery with the age of the sample.
The use ol the semi-automatic liquid-liquid extraction system of Kawahara et al 112\ was considered. A preliminary evaluation showed it to he inferior to the separatory funnel shake out. Therefore, it was not tested further. Al time zero, the mean recovery using this system was 84 percent with a range of of 77 to 92 percent.
/'u/vim f/miiic Fuiims
The use of urethane foam plugs as reported by Cesser et al [13) appeared to show promise as a means for concentrating and isolating I't B's. Thus, we evaluated the technique on dosed distilled and natural river water. Table 4 lists the data obtained using the column procedure of Cesser and by soaking the plugs in the sample. The column method worked well on distilled water and was more efficient than the soaking procedure. However, the column method was not at all suitable for use on
I Altl.l-. 1 /O'erurn' oj Amclnr 1016 from ilisiillrtl miWr ,(mg l>iilvtm'lhiiiic fount />lugs (</<e. I fJf'/stwt/;/<).
Kkvovcrv. %
Mi .in Si samples
Si.iiul.ntl tlcvialiol?
\ .11 I.UK'C
( iK'U'it-icnl of variation
Column I'llilion
84 79
too
95 91 71 I0Q 91
too
86 98 76 91 88 94 QS 84 99 114
... *
91.8 IQ 10.7 114.6
It.6
Soaking
61 89 77 58 77 95 106 109 86 50 77 50 97 60 75 114 66 98 99
too
82.2 20 20.0 399.0 24.3
DSW 033881
BtLIAR AND LICHILNBtKG ON POL YCHLOHIN A1 b L) DIPHt'NYLS 215
natvii'iiI waters. Suspended material in the samples plugged the eolumn. We were unable to pass the total volume of a 1-liter natural river water sample through the column without adding external pressure, in which ease channeling occurred. Soaking the plugs in dosed river water worked, however, the accuracy and precision was poorer than that obtained with distilled water. Coating the plugs with SE-30 did not improve the efficiency. These results coupled with the high background material from lhe foam which had significant adverse effects on the gas chromatographic (GC) eolumn and the detector were the bases for rejecting the method.
As a result of the foregoing studies, the separatory funnel liquid-liquid extraction technique was shown to be the most efficient for recovery of I'CB's from natural waters. Therefore, this method was used for analyzing all wastewater samples described next.
Wastewater samples
Several industrial wastewater samples were collected and analyzed for environmental levels of PCH's. In one ease, additional aliquots of the sample were then dosed with 5 pg/liter of Aroclor 1242 and again analyzed. Table 5 presents the results and statistical data derived from the
I
S-- Hrcuvrrv of
s front rrnimtttnrnfallv cnnttnninatrJ industrial wiistr st/mfdcs.
rom'cntnilian of A rm'lor 12d2 (pli lifer).
Koplioaics
N70
X`,0
83 2
81.1
1 2 3 4 5 h n
Mv:il! No 'l s.implcv
tics iatioii V.irijncc lodlkiaii ol ' ^nation
2.17 1.02 1.Sh 2 "*7 l.K<> I .~(1 t ..73
l.u.l 7
0.214 O.OJh 11. II
a |)oscd with 5 liicr of Aroclor L?42.
7.M) 7. 74 ".-\2 (>.07 ().42 0.70 h.75
7.15
/
0.575 0.430 8.03
SH.7 t.7.0 h-1.8 hh (> MU (ill. 3 hi.7
(.3,1 7 3.07 4.4h 4.87
13.7
1
samples. The results show good precision for two levels of environmental contamination. The precision for (he dosed samples was equally good. The recovery lor the dosed sample averaged 103 percent.
Huttoin Samples
Bottom samples collected from a large man-made lake in Ohio were found to Ire contaminated with Aroclor 1242 and 1254. Samples collected from three locations in the lake were selected in order to evaluate seven
033682
STLCOPCB4017844
216 WATER QUALITY PARAMETERS
extraction procedures. The total quantity of sample available to us limited the numbers ol' analyses that could be made. Nevertheless, useful informa tion was derived from the results. Table () lists the results of our study on the lake bottom samples. The mechanical dispersion apparatus was not available at (he lime and no comparison of this technique could be made
TAM.! <> /\Yr*Mv/r of I'CII .v (rani environmentally cwttaminuted fake bottom samples.
MciIuhI
1 >ry At.-dnr
Aiuefui
Sample (/ Matter.
1 242. Recoxerv, ^ 1254. Recovery b
Ud A re a
% " ng-'Vg
%'
Soxhlet
\u\
,T
%.7 *'
2h.2
too . 12.5
too
Simla- 1
1 r>]
.1
96.7 15..1 58.4
7.4 59.2
Blender
\2(I\
3
.17.3
5.6 21.4
9.4 75.2
SImKc tl
UM
T
37.3
t.U
T.8 2.7 21.6
Soxhlet Column 1
|/'l
UM
5
*X..4 '
54.3
too
24.7 too
s 7(vo 6.4 11.8 8.9 36.0
Soxhlet
l/'l
8
dM.d
0
Shake i
|/V|
X
0
Column 1
1 Ad
8
08.4
0
Column 1
1 AM
8
70.2
0
Blender
|.TI
8
70.2
0
Mender
1*4
8
50.0
0
Shake 11
1 AM
8
70.2
0
Shake 11
|/Y|
8
5(>.0
0
40T 100 .177 93.5 .14,1 85.1 318 78.9 343 85.1 246 61.0 321 79.7
258 64.0
0 Samples from Areas 3 and 5 were nuiek; samples from Area 8 were sandy muck. ^Recovery fur soxhlet procedure considered to be 100%. *' 10% waler added prior in extraction.
on these samples, flic results obtained show that the air-dried, 10 percent moisture-added soxhlet procedure provides significantly greater efficiency than any of the other methods tested.
In addition, a study of the recovery of Aroclor 1242 and 1254 from dosed bottom samples was carried out using three methods--mechanical dispersion, column 11, and the soxhlet. Results of this test (Table 7) show the superiority of the air-dried moisture-added soxhlet extraction pro-
TABUS 7--Recover)1 of PCR's from dosed bottom samples (dose 2.17 pg/A# total PC11 s).tl
Method
Dry
Matter. ltd %
Recovered
High frequency dispersion Column II Soxhlet
1/71 |/l (//I
S2.S 89.7 98.4
1 2
b 210 208 187 230 226
Average Recovery.
%
88.7 83.5 96.2
a Mixture of Aroclors 1242 and 1254. 118.5 pc-ky ol each. ^'Sample Insl due in malfunction of dispersion apparatus.
DSW 033883
CELLAR AND LICHTENBERG ON POLYCHLORINATED BIPHENYLS 217
cedure over the other extraction procedures as far as bottom sediments are concerned.
We acquired a sewage treatment plant sludge which was lound to contain PCB's. Aroclors 1242 and 1260 were identified in the sample. Two extraction techniques were employed in the analysis--mechanical dispersion and soxlilet extraction. The results are listed in Table 8. In this case, equivalent results were obtained with the two methods.
TABI.l: 8--Recovery <>! PCB 'n from environmentally contaminated treatment plant slmlge.
Aroi'Jor Recovered
Sumpk' No.
Method
Dry Mailer. %
1242
1260
8.11 A 8.11 H
hi^li frequency dispersion
soxlilet
18.1 'LL 2
34.4 34.4
14.2 12.5
The results of these studies show the air-dried, 10 percent moistureadded soxlilet extraction procedure to he the most efficient method for recovery of PCB's from bottom samples. This is consistent with the results reported by others for recovery of certain organochlorine pesticides from soils |22~25|. The hotter efficiency of this procedure is probably due to the smaller particle si/.c achieved when pulverizing (he dry sediment and to the longer solvent contact time provided by the soxlilet method as reported bv Saha el al |26] and Chiba and Morley 127\. Nash ct al |2<S'| evaluated soxlilet, shake, and column procedures somewhat different from those that we studied and concluded that his soxlilet and shake procedures gave near equivalent recoveries for nine pesticides from soil. In this case, the samples were not air dried or ground with a mortar and pestle prior to soxlilet extraction.
The cleanup procedures employed, the standard Plorisil and the micro silica gel columns, were adequate for all industrial waste and sludge samples. However, all bottom samples required further treatment with mercury to remove sulfur. All procedures which required a water wash of the extracts, the shake. Column II. blender, and the high frequenev dispersion methods, produced severe emulsions and additional manip ulative steps not required by the soxlilet procedure.
The high frequency dispersion technique looks promising, at leasi. for sludge samples and should be evaluated further. However, sonic problems have been encountered in its use. Small stones, pea size and even smaller, arc a hazard. They are thrown at terrific speeds into the wall of the container and w ill shatter glassware. Further, even small particle size sand causes excessive wear on the stator and rotor, in which case frequent parts replacement is required.
DSW 033884
218 WAlfcR QUALITY PARAMt 1 ERS
Conclusions
The separatory funnel liquid-liquid extraction procedure is the method of choice lor recovery of RGB's from natural waters. The air-dried soxhlcl extraction procedure is the method of choice lor recovery of RGB's from bottom and sludge samples. Formaldehyde effectively preserves PCB's in dosed natural water samples, at least up to two weeks.
Ai`kn<twLulf>mcni.s
The authors wish to thank James O'Dell for his assistance in collection, preparation, and extraction of the samples used in this study. 'Hie GC-MS confirmatory analyses were performed by J.W. Eichelbcrger and L.F.. 1 larris.
References
[/| IV;ik:ill. I>. n. ami l.invei. L L.. JW.vVmcv. Vol. 20. 1070, p. 9S8.
U7| Gustafson, C. G.. F.nvironmentul Sciatic urn/ Technology. Vol, 4, 1970. p. 815.
I d 1 >\*kc. 1. VV.. el al, Bulletin of Lneironmental Contattiinaluut and I'oxicology. Vol. 5.
1971. |>. 171.
`
|/| Veilh- G. IT. and t.ee. (I. h\. Water Rese<ireh. Vol. 5. 11>71. p. 1107.
J.SJ Veith, G. D. and Lee. G. F.. Proceedings, 14th Conference on Great Lakes Resources. International Association of Great Lakes Resources. 1971. pp. 157M69.
p>j /ilko. V.. Bulletin of lineironmental Contamination and Toxicology, Vol. 5. 1970.
p. 279.
'
171 Sanders H. O. and Chandler. J. H.. Bulletin of Environmental Contamination and Toxicology. Vol. 7. 1972. p. 257.
|A'l Armour, J. A. and Burke, J. A., Journal of the Association of Official Analytical Chemists, Vol. 53, 1970, p. 761.
|9| lx`oni. V.. Journal of Chromatography, Vol. 62. 1971. p. 63.
\I0\ Wohb. K. G. and McCall, A. C., Journal of'Chromatographic Science. Vol. It. 1973. p. 366.
|//j "Methods tor Organic Pesticides in Water and Wastewater." U.S. Environmental Pro
tection Agency. National Environmental Research Center. Cincinnati, Ohio. 1971.
|/2| Kaxvahani. F. K. el al. Journal of the Water Pollution Control Federation. Vol. 39. !9(7. p. 572.
|/3| Gcsser. H. L). et al. Analytical Letters. Vol. 4. 1971. p, 883.
(//) Breidcnbach. A. W. et al, "The Identification and Measurement of Chlorinated Hydro
carbon Pesticides in Surface Waters.*' U.S. Department of the Interior, Federal Water Pollution Control Administration, Publication WP-22. 1966. |/51 Hessclberg, R. J. and Johnson, J. L.. Bulletin of Environmental Contamination and
Toxicology. Vol. 7. 1972. p. 115. |/6) "Pesticide Residue Methods for Sediment and Fish." Method SP-8/71. Southeast En
vironmental Research Laboratory. Environmental Protection Agency. Athens, Ga.
|/7| Johnson. K. I*, and Starr. K. I.. Journal of Agricultural and Food Chemistry, Vol. 20.
1972. p. 48.
' '
(/A) Goerliu, D. F. and Brown. E.. Techniques of Water Resources investigations of the
United States Geological Survey, Book 5. Chapter A3, 1972. |/(/| "C'hlnnmilcd Pesticide Residues in Water. Soils, Crops, and Animal Products," Method
PMS-91 /67. Manual of Methods for the Determination of Residues of Shell Pesticides.
Shell Chemical Company. I%7.
DSW 033885
BELLAR AND LICHTENBERG ON POLYCHLORINATED BIPHENYLS 219
J7Y7J Muili. J . unpublished work. September 1971.
|?/) Gocrlil/.. D. P. and Law, L. M., Bulletin of Environmental Contamination and Toxi cology. Vol. <1. 1971. p. 9.
122\ Williams, !. H.. Journal of' the Association of Official Analytical Chemists. Vul. 51,
1908. p. 715.
'
....
|27) Woolsoit. fi. A. and Kearney. P. C.. Journal of the Association of Official Analytical Chemists. Vol. 52. 1^69. p. 1202.
|.V) Nash. K. G. and Harris, W. G.. Journal of the Association of Official Analytical
Chemists Vol. 55. 1972. p. 532.
....
(2.51 Tcnslcy. J. 1. and Cox. W, S.. Journal of Agricultural and Food Chemistry, Vol. M.
19(>(>, p. 519.
`
'
12/51 Saha. J. G. el al. Journal of Agricultural and Food Chemistry, Vol. 17, |%9. p. 877.
|27| Chiba. M. and Motley. Jl. V.. Journal of Agricultural and Food Chemistn1. Vol. 16.
1908. p. 9Hi.
'
'
'
12,S') Nash. R. G. cl nl. Journal of the Association of Official Analytical Chemists. Vol. 56.
197.1. 729.
'"
a.
QSW 033886 STLCOPCB4017848