Document RpMD5DGDx0da59LRk21aebGNX

DOW CHEMICAL U.S.A. 50963_______________________________________________ _ TEXAS DIVISION FREEPORT, TEXAS 77541 ENVIRONMENTAL HEALTH REPORT AIRBORNE ASBESTOS SURVEY CATHODE CLEANING UNIT OYSTER CREEK DIVISION FILE NO. OCD-327 datf April 9, 1974 H.author N. Edwards A-'' CHECKED DATE____ d/a L Summary A survey for airborne asbestos was made at the cathode cleaning unit. All analyses were below the levels required for the asbestos standard established by the Occupation Safety and Health Act (OSHA). ^"H o CD cn CD CO Distribution M. E. Sanders OCD C. J. Barras OCD c. E. Caldwell OCD R. c. Miller OCD R. E. Flake B-101 J. D. Laman B-1226 JU c. L. Sercu- Cleveland * R. * / *'Fil Vaughn (2) Plaquemine H. R. Hoyle 1707 Bldg. -Midland 'F. D. Axe - Pittsburg AN OPERATING UNIT OF THE DOW CHEV STOO14508 STQ0I4509 File No. OCD-327 -2- INTRODUCTION The Occupational Safety and Health Act (OSHA) requires that occupational exposure to airborne asbestos dust be controlled so that no worker is exposed to more than 5.0 asbestos fibers per cubic centimeter of air based on a count of fibers greater than 5 micrometers in length. These are determined as a time-weighted average (TWA) exposure for an eight hour work day, and no peak concentrations of asbestos more than 10.0 fibers per cubic centi meter as determined by a minimum sampling time of fifteen minutes. This survey evaluated the airborne asbestos at the cathode cleaning unit. METHODOLOGY The cathode cleaning area was surveyed and ten locations were selected as stationary points for monitoring (Fig.l). Four other samples were collected from a monitor worn by a Technician during four hours of work. Airborne samples were collected using the Micronair permissible air sampling pump (Bendix Environmental Science Division, Baltimore, Maryland). The asbestos was collected by pulling air through a millipore filter. Flow rates for the pumps were cali brated at 1500 cubic centimeters per minute and the sample times for the stationary pumps were thirty minutes while the time for sampling of the personnel monitor was one hour each for four hours. All analyses were done by Lee Martin B-1218. RESULTS There were no asbestos levels that exceeded the limits established by OSHA, (Table I). This operation seems to keep everything damp at all times and therefore asbestos levels are low. CONCLUSIONS Airborne asbestos measured during this survey are well below the current Threshold Limit Values (TLV). ST0014509 File No. OCD-327 -3- RECOMMENDA TIONS (1) Even though the concentrations of asbestos are below the TLV, care should always be used when handling the material. (4) When the weather is warm and outside the cleaning area is dry, another survey should be made. This would evaluate the levels created by the truck traffic along the roadways. STOO I 45 I 0 EHS HNE/bbs 4-9-74 ST0014510 ST00I45!I TABLE I AIRBORNE ASBESTOS Fibers greater than 5.0 micrometers per cubic centimeter LOCATION NO. OF FIBERS (1) (Fig.I) Change Room, dirty clothes area 0.30 (2) (Fig.l) Lunch Room, on table 0.16 (3) (Fig.l) On cathodes that have been cleaned 0.27 (4) (Fig.l) On wall (51 from floor) - 0.86 (5) (Fig.l) Between motors (5* from floor) 0.67 (6) (Fig.l) On wall (51 from floor) 0.10 (7) (Fig.l) On cathodes - ready forcleaning 0.16 (8) (Fig.l) Along road on cathodes (5' from ground) 0.10 (9) (Fig.l) Along road on cathodes(41 from ground) 0.12 (10) (Fig.l) Along road on cathodes(4* from ground) 0.13 PERSONNEL MONITOR First hour------------------------------------------------------------------------ 0.73 Second hour------------------------------------------------ ,-------------------- 0.13 Third hour----------------------------------------------------------------------- * Fourth hour--------------------------------------------------------------------- 0.10 * Filter became wet during work (unable to evaluate) EHS HNE/bbs 4-9-74 ST0014511 ST0014512 ST00 I lj 5 I 2