Document RpLom5Qpqd0DJ7jQBRv2L6dkX
i
V?
~>Mr. F. A. Barker Mr . Jack Clegorn
January 21, 1947
rjdf'iV.. . .
xw?
^1 t* . vV-
--
;Mr. J,- Fred Beeves
GBHEBAL ELECTRIC - PETSFISID
c? *1#? *i'f-C*Kv*
' "" asIa referenc# to.Hr; tpieelo<*if'letter of January 15, Attached, 1 have dieeussed the Annistoni analysis ofAroclare VithMr^w
?4 V5 ,, Cfl, i*.v#fL . %*$ /ii-p.
|U ~~^"*jrS2 &*-?* fs.
Clegorn, Sir* Jenkins and Mr, Barker and I do not Believe that
Anniston is far off Base, If at all, on our Aroolcrs or their
analyses* Ton will note Mr. Barker's letter, attached, concern-
lng the pour point of our Aroclor 1254. Mr. Barker has checked
pour points on the same material By five different people who
formerly analysed drooler regularly, These five people Inde
pendently arrived at a 10q pour point on the same sample.
~
Our laboratory, using the ASTM method and ASTM standards, states
that Individual results on the same oil In any one laboratory
may vary by 5F, whloh is 2.8^3 and that different labcratarles
may vary By 109F, which la 5,6C although the average of three or
more results in different laboratories should show the differences
Between averages no greater than > which is 2.8C.
J ...
The test that Mr, Saab ran shows a reproductivity of results of
-4 plus or minus cflC and you will note that the tabulation of our pour point with the G.S. pour points varies By only 1.89F on the average.
This is well within the limits allowed Bj dSTK standards.
.
.
-
y-V : .!
m/' . :.
* Yi;
The ASTM standard method calls for the use of ice to cool the
sample. In the range for Aroclor 1254 the G.S. analytical calls
far the use of liquid air or liquid oxygen. It Is my belief that
the cooling By liquid, air Is very rapid at the outside of the tube
and that the Aroclor can Be stiffened Before a true and correct
temperature is shown on the thermometer near the center of the tube.
The use of Ice does not allow such rapid chilling and I Believe
that our thermometer will probably read closer to the true tempera
ture of the Aroclor. In any case, If G.S. uses liquid air and we '
latC7, V *; vV<V^F/-
' use Ice, this. Is probably the .reason for the difference In pour .. v pointsi A Furthermore, I d^|o^|k|xcwiwhdt3^?r.'|t''.E. haA^s|ted their^|;|j;
-?V 'll,.
method wlreproductivity .ofiresults as/haaBu* labaw^ary*: have not 1 Believe that this should Be done, - vi`
they./'.
..
* ^V4**
, i-S'-ts* jvj
G.E. also states that Anniston resistivities of 300 z 10^ Is Below ,
specification. This is not so as our specification statea that resistivities shall Be above 100 x 10^. I am sure that Both G.S. and our Sales Department Is aware of this. I am unable to see why there Is a difference between the resistivity results of our labora tory and G.S. They state that we may have a dirty cell. It may
DS\N 330987 STLCOPCB4077631
T i
Mr. J. I. Beeves * Pags #2.
1/21/47
also 1>e that there 1b a difference In methods or In the machines
used for this test. Z have been unable to find anything about
this. : - ; r*
. V \ ' ' `
-
- " rikyS r
M *4*h General Jleotrlc has. also stated that a value of .,125 for /Chlorides,
* *>
t **l
4-
1'*' *4** 1 * - /2//<~v - t ,. _ 'u'^' :^_^ >. . - -s.
^
in the corrosion test,Is above specification,
Shis Is not so as
:
, :
*
*
they *do?"
fojt&i^'^tes^^^^|^^aat1^:|^^dlse^i^';a^ great!
length some >ears ago and that' it was discovered that due to differences
in the quality of vlcoelmeter or to the differences in methods It
was impossible to check on this determination, I do not know the .....
whole story but Hr. Jenkins has it in his files and has promised to
, send it to me. However* It seems that Q.Tt, is aware that they normal
ly get approximately 15 seconds higher and Z do not understand why
G.l. now complains about a difference. / 1 ,
..
Z note that on the third and last page in the table of defects that the refractive index 1b above specification for two lots. The speci fications for refractive index for Fyranol 1467 are 1.6137 to 1.6l47, Z do not understand why these lots are high. ,
GJC. evidently Is worried about a discrepancy in analytical results
rather than about any defective or off grade Aroelor or they would
be complaining about the quality of the material rather than about
analytical results. With the exception of the refractive Index of
1467 and poesibly the resistivity of 1254, I see no serious error
.
on the part of the Anniston plant or laboratory and it Is quite like
ly that a careful cheok of resistivity will reveal a condition similar
to the pour point and viscosity determination where the differences
can easily be explained. - /*
*
,,
-.
<
k, ,v yiy*
fsii
' %.
"*
y
,,< ^
. '/ 1 V .*% > ,
v,lt. ?. Leaven
#gtT' ^ fl
r
*
____
- .
DSW 330988 STLCOPCB4077632