Document Rp9dK375nx3DmejLNa4ELNJRv
Gas Turbine Carries Load On Texas Lines
Regional utility finds gas tur bine does' excellent |ob in back ing up transmission line and on peaking service*
In May 1952, Texas Power & Until Co.placed Sia fim gas turbine in service in its Dixon Street Station at Gaines ville, Tex. The 3500-kw, regenerative, 2-thaft unit drives a 5000-kvn genera'tor. The get turbine was InstsUcd in parallel with a 1000-kw dual-fuel intemal-combustion engine.
These units were telecied after an exhaustive economic tludy comparing Various types and sites of steam units, internal-combustion engines and gas turbines. With the station completed, the investment proved to be very close to the estimate, and fuel consumption less than expected. Other costs and fac tors (ell close in line with the estimete.
The-gas turbine has run over 1100 hours, being used almost daily for peak ing service. Both units con be started quickly in transmission-line failure. It
has been the practice to run the gas turbine when ice storms are expected. With a thermal efficiency over 23% (based on HHV of gas) the gas turbine
K competes with the system steam plants, considering (he remoteness of Gaines ft ville ond unavoidable transmission-line
. losses. - The 2-shaft unit has both turbine wheels In one casing. The single-stage high-pressure turbine drives the only Hiioge axial-flow compressor, while the
single-stage low-pressure turbine drives (Continued on page 230)
'iNVMN Ni "Binwilln Om TvrMiw-Ovwrtlir fw Ouitnl SMUao Santa." by 9 C D*rii, Tmi rmr a Lift* c. u< b l jMta*. owti fttavit Ca. R**d Mn Haitian Frif CiMrMftri. OliiM uinfc iS-ti. list.
HOT Aid AND GAS DUCTS run under operating floor connecting goi tuibine uf"^ ond outdoor regenerotor. Combustors oheod of turbine ore homed under large cov**:
64 I ENGINEERING AND MANAGEMENT SECTION