Document Rp7M8jOvZqKo3oJpNm7XwQEQ7

Boilers Spencer Heater Company Williamsport, Pa. NEW YORK BOSTON SYRACUSE PHILADELPHIA BALTIMORE ALBANY HARRISBURG Builders of Spencer Heaters BUFFALO ROCHESTER SCRANTON SPENCER HEATERS Give uniform heat over long periods and use small size hard coal with least attention to the fire. . The magazine-feed feature is built into the heater and requires no,adjust ment The magazine holds a supply of coal sufficient for 8 to 12 hours ip severe weather or for a proportionately longer period in milder weather. Spencer Heaters are economical and efficient. .... .. . Due to the magazine-feed feature of the Spencer Heater it is impracticable to obtain a firing period of less than 8 hours. Therefore ratings of Spencer Heaters are based upon an evaporation of 8 lbs. of water per lb. ot coal burnea, the rated evaporation having been obtained in actual test using fresh mmea No. 1 Buckwheat coal as fuel. too i iSerieis 50 Series^ s Y* 5 S S 5 S SO Series. Spencer Tubular Heater 100 Series. Spencer Tubular Heater SPENCER TUBULAR STEAM HEATERS Heater Number Rating Sq. Ft. Radia tion Fire Surface Heating Surface krk Tapping Return Sq. Ft. Sq. Ft. Overall Length Ins. Overall Width Ins. Water Line Ins. Draft to Develop Rating Ins. H2O Size Chimney Flue 15 ,417 19 20 21 2.000 2.500 3.000 3.500 4.000 12.00 13.50 15.00 16.50 18.00 282 309 337 365 393 2-4* 2-4* 2-4* 2-4* 2-4* : 2-2%' 2-2%' 721/; 78% 84% 96% 62% 62% 62/2 S6 56 56 56 56 4.500 5.000 5.500 6.000 7,000 18.05' 20.24 22.56 24.83 27.00 389 429 468 506 547 2-5' 2-5' 2-5* 2-5'2-5' m 2-2(4' 2-2%' 99'/, 105% 112 118% 124% 81% 81% 81% 81% 81% 59 59 59 59 59 8,000 9.000 10,500 12.000 14.000 16.000 30.35 34.70 39.05 43.40 47.75 52.10 560 621 683 745 607 869 1-8* 2-21/," 98 116% 66 1-8' 1-8* 2-2%' 104% 2-2%' 110% 116% 116%- 66 66 1-8' 2-2Vf 116% 116% 66 1-8* 2-2%' 123 116% 66 1-8*. 2-2'%' 129% 116% 66 .23 I8'xl8'x50' .24 18*xl8*x55' .25 18*x18**60' .26 I8*x!8*x65' .27 18*xl8*x65' .24 I8**18'x50' .25 18*x18'x55' .26 18*x18*x60' .27 20* Diam. x 65' .28 20* Diam. x 70' .27 24* Diam. x 65' .28 24* Diam. x 65' .29 30* Diam. x 65' .30 30* Diam. x 70' .32 36* Diam. x 70' .34 36* Diam. x 70' Heaters No. 8-45 to 3-160 are furnished with steel jackets and 1H in. Rockwool asbestos covering, also pipe header. .................... , Heaters No. 15-21 are furnished with steel jackets only. ^ _ , *, * , cTM ^ Chimney Flue sizes are based on a maximum Flue Temperature at Boiler Smoke outlet of 500 deg. fahr. 440 Spencer Healer Company 1 SPENCER Jare adaptable for residences, apartment houses, churches, schools, public and commercial buildings, theatres, green houses ogarrhaoget swaantedr.all other types of buildings heated by low pressure steam, va^por For over 25 years SPENCER HEATERS have been tried and tested under the most severe climatic conditions. There are thousands of successful installations throughout the entire country. Write for illustrated catalog containing complete information. Boilers rfWTir. i>. ? ii r * k k: 4 No. & Series. Spencer Sectional Heater No. I Series. Spencer Sectional Healer SPENCER SECTIONAL STEAM HEATERS Heater Number Rating So. Ft. Radiation Fire Surface Sq.Ft. Tapping Tapping Flow Return Overall Length Ins. Overall Width Ins. Water Line Ins. I--5--S 1-6-S 1-7-5 1-8-S 1-9-S 2-6-S 2-7-S 2-8-S 2-9-S 2-IO-S 2-1l-S 1-5-W 1r6-W 1-7-W 1-8-W I-9-W 2-6-W 2-7-W 2-0-W 2-9-W 2-10-W 2-11-W 600 750 900 . 1,050 1,200 1,300 1,600 2,000 2.400 2,800 3,200 1.000 1,250 1.500 1,750 2.000 2,100 2,600 3,200 3.800 4,500 5.100 I2.26 1-4* 2-4* 2.82 1-4* 2-4* 3.38 1-4* 2-4* 37% 37% 37% 3.95 1-4* 2-4* 66% 37% 4.51 1-4* 2-4* 73% 37% 1%5.64 ' 6.77 2-4* 2-4* 2-4* 2-4? 68% 74% 7.90 2-4* 2-4* 81% 57% 89.03 10.16 11.28 2-4* 2-4* 2-4* 2-4* 2-4* 2-4* 87% 93% 99% 57% 50* 50* 50* 50* 50* 50* 50* 50* 50* 50* 50* SPENCER SECTIONAL WATER HEATERS 2.26 2.82 3.38 3.95 4.51 5.64 6.77 7.90 9.03 10.16 11.28 2-4* 2-4' 2-4* 2-4' 2-4* 2-4* 2-4* 2-4* 2-4* 2-4* 2-4* 2-4* 2-4* 2-4* 2-4* 2-4* 2-4* 2-4' 2-4* 2-4* 2-4* 2-4' 48% 343/S 60% 66% 73% 68% : 74% 81% 87>/S 93% 99% 37% 37% 37% 37% 37% 573/. 57% 37% 573/, 57>% 57/, 441 Draft to Develop Rating Ins. H]0 Size Chimney Flue 0.12 0.13 0.14 0.15 0.16 0.17 0.18 0.19 0.20 0.21 0.21 8%*il3*x35' 8%*xl3*x35' 8%*x13*x40' 13* x13*x40' 13* x!3*x40' 13' x13*x40'. 13* x!3*x40' 13' x13'x40' 13* xl3*x40' 13* x18*x45' 13* x18*x45' 0.12 0.13 0.14 0.15 0.16 0.17 0.18 0.19 0.20 0.21 0.21 8%*x13'x35' 8%*x13*x35' 8%'x13*x40' 13* x13*x40/ 13* x!3*x40' I3*x13*x40' 13*x13*x40' I3'xl3'x40' 13*x13*x40' I3*x18*x45' 13*xl6'x45'