Document Rp7M8jOvZqKo3oJpNm7XwQEQ7
Boilers
Spencer Heater Company
Williamsport, Pa.
NEW YORK BOSTON SYRACUSE
PHILADELPHIA BALTIMORE
ALBANY
HARRISBURG
Builders of Spencer Heaters
BUFFALO ROCHESTER SCRANTON
SPENCER HEATERS
Give uniform heat over long periods and use small size hard coal with
least attention to the fire.
.
The magazine-feed feature is built into the heater and requires no,adjust
ment The magazine holds a supply of coal sufficient for 8 to 12 hours ip
severe weather or for a proportionately longer period in milder weather.
Spencer Heaters are economical and efficient.
....
.. .
Due to the magazine-feed feature of the Spencer Heater it is impracticable
to obtain a firing period of less than 8 hours. Therefore ratings of Spencer
Heaters are based upon an evaporation of 8 lbs. of water per lb. ot coal burnea,
the rated evaporation having been obtained in actual test using fresh mmea
No. 1 Buckwheat coal as fuel.
too i iSerieis 50 Series^ s Y* 5 S S 5 S
SO Series. Spencer Tubular Heater
100 Series. Spencer Tubular Heater
SPENCER TUBULAR STEAM HEATERS
Heater Number
Rating
Sq. Ft. Radia
tion
Fire Surface
Heating Surface
krk
Tapping Return
Sq. Ft. Sq. Ft.
Overall Length
Ins.
Overall Width
Ins.
Water Line Ins.
Draft to Develop Rating Ins. H2O
Size Chimney
Flue
15
,417
19
20 21
2.000 2.500
3.000 3.500 4.000
12.00 13.50
15.00
16.50 18.00
282 309
337 365 393
2-4* 2-4* 2-4* 2-4*
2-4* :
2-2%' 2-2%'
721/; 78% 84%
96%
62%
62% 62/2
S6 56 56
56 56
4.500 5.000 5.500 6.000 7,000
18.05' 20.24 22.56 24.83
27.00
389 429 468 506 547
2-5' 2-5' 2-5*
2-5'2-5'
m
2-2(4' 2-2%'
99'/, 105% 112
118% 124%
81%
81% 81% 81% 81%
59 59 59 59 59
8,000 9.000
10,500 12.000
14.000
16.000
30.35
34.70
39.05 43.40
47.75 52.10
560 621 683
745 607 869
1-8* 2-21/," 98
116%
66
1-8' 1-8*
2-2%' 104% 2-2%' 110%
116% 116%-
66 66
1-8' 2-2Vf 116% 116%
66
1-8* 2-2%' 123
116%
66
1-8*. 2-2'%' 129% 116%
66
.23 I8'xl8'x50' .24 18*xl8*x55' .25 18*x18**60' .26 I8*x!8*x65' .27 18*xl8*x65'
.24 I8**18'x50' .25 18*x18'x55' .26 18*x18*x60' .27 20* Diam. x 65' .28 20* Diam. x 70'
.27 24* Diam. x 65' .28 24* Diam. x 65' .29 30* Diam. x 65' .30 30* Diam. x 70' .32 36* Diam. x 70' .34 36* Diam. x 70'
Heaters No. 8-45 to 3-160 are furnished with steel jackets and 1H in. Rockwool asbestos covering,
also pipe header.
.................... ,
Heaters No. 15-21 are furnished with steel jackets only.
^ _ , *, * , cTM ^
Chimney Flue sizes are based on a maximum Flue Temperature at Boiler Smoke outlet of 500 deg. fahr.
440
Spencer Healer Company
1 SPENCER
Jare adaptable for residences, apartment houses,
churches, schools, public and commercial buildings, theatres, green houses
ogarrhaoget swaantedr.all other types of buildings heated by low pressure steam, va^por
For over 25 years SPENCER HEATERS have been tried and tested under the most severe climatic conditions. There are thousands of successful installations throughout the entire country.
Write for illustrated catalog containing complete information.
Boilers
rfWTir. i>.
? ii
r *
k k: 4
No. & Series. Spencer Sectional Heater
No. I Series. Spencer Sectional Healer
SPENCER SECTIONAL STEAM HEATERS
Heater Number
Rating So. Ft. Radiation
Fire
Surface Sq.Ft.
Tapping Tapping
Flow
Return
Overall
Length Ins.
Overall
Width Ins.
Water
Line Ins.
I--5--S 1-6-S 1-7-5 1-8-S 1-9-S
2-6-S 2-7-S 2-8-S 2-9-S 2-IO-S 2-1l-S
1-5-W 1r6-W 1-7-W 1-8-W I-9-W
2-6-W 2-7-W 2-0-W 2-9-W 2-10-W 2-11-W
600 750 900 . 1,050 1,200
1,300 1,600 2,000 2.400 2,800 3,200
1.000 1,250 1.500 1,750 2.000
2,100 2,600 3,200 3.800 4,500 5.100
I2.26 1-4* 2-4*
2.82 1-4* 2-4* 3.38 1-4* 2-4*
37% 37% 37%
3.95 1-4* 2-4* 66% 37%
4.51 1-4* 2-4* 73% 37%
1%5.64 '
6.77
2-4* 2-4*
2-4* 2-4?
68% 74%
7.90
2-4*
2-4*
81%
57%
89.03
10.16 11.28
2-4*
2-4* 2-4*
2-4* 2-4*
2-4*
87%
93% 99%
57%
50* 50* 50* 50* 50*
50* 50* 50* 50* 50* 50*
SPENCER SECTIONAL WATER HEATERS
2.26 2.82 3.38 3.95 4.51
5.64 6.77 7.90 9.03 10.16 11.28
2-4* 2-4' 2-4* 2-4' 2-4*
2-4* 2-4* 2-4* 2-4* 2-4* 2-4*
2-4* 2-4* 2-4* 2-4* 2-4*
2-4* 2-4' 2-4* 2-4* 2-4* 2-4'
48% 343/S 60% 66% 73%
68% : 74% 81% 87>/S
93% 99%
37% 37% 37% 37% 37%
573/. 57% 37% 573/, 57>% 57/,
441
Draft to
Develop Rating Ins. H]0
Size
Chimney Flue
0.12 0.13 0.14 0.15 0.16
0.17 0.18 0.19 0.20 0.21 0.21
8%*il3*x35' 8%*xl3*x35' 8%*x13*x40' 13* x13*x40' 13* x!3*x40'
13' x13*x40'. 13* x!3*x40' 13' x13'x40' 13* xl3*x40' 13* x18*x45' 13* x18*x45'
0.12 0.13 0.14 0.15 0.16
0.17 0.18 0.19 0.20 0.21 0.21
8%*x13'x35' 8%*x13*x35' 8%'x13*x40' 13* x13*x40/ 13* x!3*x40'
I3*x13*x40' 13*x13*x40' I3'xl3'x40' 13*x13*x40' I3*x18*x45' 13*xl6'x45'