subiec. Asbestos Sar.p3.ing at AT&T Co. , Raritar. River Center, Piscataway New Jersey, May 3, 1978
K/fr. Tbp<SL
f~~C C--
Bell Laboratories
date: June 15, 1978 from V. R. Cohen
MEMORANDUM FOR RECORD
INTRODUCTION
At the request of Mr. Ted Inge an environmental survey was performed "where bulk insulation had been installed on struc tural members of the Raritan River Center. Bulk analysis of the insuiatjng material performed on May 26, 1976 showed the material to contain from 14% to 50% asbestos (analysis per formed by ES Laboratories, Marlton, New Jersey). The results of these analyses were sent to Mr. R. J. Gonzalez on June 29, 1976.
Summary
To access a possible health hazard due to airborne asbestos fibers, environmental measurements were performed on May 3, 1978. Fiber concentrations determined from phase contrast analysis were well below the current Occupational Safety and Health Administration (OSHA) Standard of two fibers per cubic centimeter longer than 5 micrometers (ym).
No asbestos was detected in any of the air samples analyzed by transmission electron microscopy. The lower limit of detection of these analyses was .03 fibers per cubic centimeter.
Standards
The present standard for asbestos promulgated by OSHA is two fibers per cubic centimeter greater than five ym in length. The two fiber limit refers to an eight hour time-weighted average permissible exposure limit and includes a ten fiber per cubic centimeter ceiling concentration which is not to be exceeded.
003721
2
The recommended standard proposed by the National Institute for Occupational Safety and Health (NIOSH) is 0.1 fibers per cubic centimeter greater than 5 ym in length as an eight hour time-weighted average permissible exposure limit and a C.5 fiber per cubic centimeter ceiling concentration.
Sampling Techniques
Samples were collected on 37mm open faced Millipore cellu lose ester and Nucleopore polycarbonate filters with a 0.8 ym nominal pore size diameter. Air was p< lied through the filters with portable, battery powered Mine Safety Appliance and Bendix Corporation pumps at 2.5 liters per minute.
The pumps were calibrated with the soap bubble flowmeter technique. Analysis for asbestos using phase contrast micro scopy as required by OSHA was performed by V, R. Cohen at Bell Laboratories and by McCrone Associates Chicago, Illinois. Transmission electron microscopic analysis was performed by McCrone Associates, Chicago, Illinois. This procedure provides analytical identification of the various mineral phases present as well as better fiber (<1.0 ym in diameter) resolution.
In addition twc bulk samples collected in the hallway of building 3 and the telephone closet, room 1C-207, of building 1 were sent to ES Laboratories for analysis by X-ray diffraction.
Discussion and Results
Table I shows the fiber concentrations measured in various loc-tions at the Raritan River Center. Samples were collected in each of the three buildings. An outside ambient sample was taken as well. In all areas where air samples were collected., false ceilings were installed. Low fiber concentrations were found in all samples analyzed by phase contrast microscopy. The results are all well below the current OSHA Standard. The transmission electron microscopic results are found in Table II. There were no asbestos fibers detected in the analyses.
The bulk sample from the telephone closet of building 1 was shown to contain 20$ chrysotile asbestos. The bulk sample from the hallway of building 3 contained 25$ chrysotile asbestos.