Document Rp4oZ50j7Ln1wK0292rMYK8OV
ELECTRICAL HAZARDS
Test equipment
Most electrical
equipment is designed
for safe operation un der limited overload conditions for varying periods of time. Op erators should be thor
oughly familiar with the limitations of their equipment and should be trained to observe and report abnormal oondibons Continued overload may intro duce additional oper ating hazards by caus ing fire, short circuits, circuit failures, or ma chine failures
Through the use of
various types of elec
trical testing meters,
many of these condi
tions can be detected
before they get out of
control and cause Hg. 31-8. An electrician checking equipment with on insulation
damage
resistance tester His findings will be recorded on a chart
The following types similar to thot shown In Fig 31-9
of equipment are standard and should
Courtesy Associated Research, /nc
be considered even by
plants with limited budgets split-core am ure voltage and an ammeter to measure
meter, voltmeter, ammeter, megohmmeter, current When these two instruments are
ground fault indicators and locators, watt used, more accurate readings can be taken
meter, industrial analyzer, recording instru Also separate instruments are useful when
ment, and specialized testing instruments simultaneous voltage and current readings
The split-core ammeter can be used with out tapping into the circuit The instru ment's core is slipped around the electnc leads, and the scale is then read for the
are needed Such readings might be neces sary when tests are being made to check on voltage surges or dips and unusual power conditions while current is on
amount of current flow A current read
When the current to be measured exceeds
ing in excess of the rated full-load current the ammeter's range, shunts should be used
gray indicate an overload or a grounded They are generally limited to direct current
motor winding.
instruments and to current transformers for
When test leads are used with this instru alternating current measurement Likewise, ment, the line voltage can be checked to see when voltages exceed the voltmeter's maxi
if it equals the motor voltage rating This mum rating, resistors or potential trans check is important because low voltage can formers must be used to step down voltage
cause excessive current flow which may re
The megohmmeter ("megger") is a high-
sult in a complete breakdown, arcing, or scale ohmxneter which gives the value of
electrical fires
insulation resistance Almost every wire in
Voltmeter and ammeter When the voltage a plant (including the wires on motors, gen
and current used in a plant exceed the range erators, and transformers) is wrapped in of a split-core ammeter, separate instru electrical insulation
ments should be used a voltmeter to meas-
Not all electrical insulation provides a
31-17