Document Rp41nL9DzxJDq3R6Nm5ZrJd0B
Gns-Liquitl Chromatography--Mass Spectrometric
Characterization of Aroclor 1242 ami 1254 Components (i l>y S- N. HnnvK, It. E. Uonciunu, L. 0. Hanskn, and H. L. Mi.tcali V UeftuTUnent of Phyt-iotopy aml I'hurmutolnpy
College of roturinarv Medicine Xlnivoraity of llliiwit
1: Urbanity UL 61801
I!
I!: The recently discovered toxic hazards of PCB have encour aged a search for alternative cnemicals but the millions of pounds of PCB already produced will continue to pose a threat for many years. PCB residues are virtually ubiquitous and to attempt enforcement of very low tolerance levels would impose tremendous hardships on several industries And geographical locations (e.gv communities where fish from Lake Michigan are dietary staples)* Thus, it is necessary to establish the toxic hazards of low level PCB intake, the rates of accumulation and depletion of residues, and the most offensive and persistant components of the complex mixtures introduced into the environ, ment. In order to accomplish these goals, a monitoring system which will discriminate among the various components of these complex mixtures must be developed.
Several laboratories (HUTZINOER gt al. 1970, SISSONS and WELTI 1971, STALLING and HUCKIMS 1971, ROTE and MURPHY 1971, WEBB and McCALL 1972, and ROTE and MORRIS 1973) are investi gating the PCB components In commercial mixtures and are using GC-MS methods for analysis and confirmation of PCB. This lab oratory is investigating the pharmacokinetics and tissue resi dues of the Individual components after administration as Aroclor 1242 or 1254, This should single out the more persis tant components of the mixtures and provide metabolic profiles of the PCB to permit more precise recognition of PCB after exposure to biological systems* Since each batch of Aroclor differs slighty from other batches, this paper is intended to characterise the Aroclor mixtures we will use in all subsequent investigations and to Introduce our peak identification system for future reference* A subsequent publication (WELBORN ( }, in press) will discuss extraction and quantitation procedures.
MATERIALS AND METHODS
The designation of peaks by letters a through t are based on the tritium electron capture gas chromate .raphy TeC-GC) tracing of both Aroclor 1242 and 1254 combined in equal amounts by weight. The later peaks (longer RRT) of 124? and the early peaks (shorter RRT) of 1254 occur at similar retention times; thus, some letter codes appear In the standard tracings of both Aroclors (Figure l)* The instrument used was a Varlan Aero graph Model 2700 with 6' x glass columns packed with 3& OV-1
138
Bulltiia (
S Tt-iroWi*y,
Vpl. 12, No- I 15 IJ7 S,rlnti'Nr*r Y*>k in*.
on 100/120 eliromosorb W. Nitrogen carrier gas flow was adjusted to give a standard retention time for peak and injector, column, and detector oven temperatures were maintained at 24oC, 200C, and 24oC respectively.
In order to determine the percentage of chlorine found in each component of Aroclor 1242 (peaks a through p) and Aroclor 1254 (peaks g through t_), a mass spectrum of each Aroclor was obtained. The present study was carried out on a Hitachi-Perkin Elmer mass spectrometer RMU-6E with Varlan 1200 gas chromato graph. The stainless steel column (6' x 1/8" O.D.) was packed with 3* OV-1 on 80/100 chromosorb W HP. The mats spectra were recorded at 22 ev electron energy with 1875 v accelerating volt age and filament emission current was 3.2 uA. Helium carrier gas flow rate was 35 mls/min and injector and column tempera tures were maintained at 290, 280 respectively. The mass spectra were scanned magnetically over the range of me/e 600.
To determine the amount of PCB contributed by each compon ent (peak) to the total Aroclor, a tracing for each Aroclor was obtained from thermal conductivity gas chromatography (TC-OC). Even though EC-GC is the most sensitive method for detecting chlorinated biphenyls, the peak areas do not necessarily corre spond to the amount of each coiqponent present In the mixture. The peak areas obtained by TC-GC are directly proportional to concentration and can be used to calculate the percentage that each component contributes to the total amount injected. Thus, If peak n contributes 16.7% to the total Aroclor 1254 mixture, then a 2T0 og injection of 1254 will contain 0.167 x 2.0 * 0.334 ng of component n.
A Varian Autoprep A-700 gas chromatograph with a thermal conductivity detector was used. The 5' x 1/4 " stainless steel column was packed with 20% SE 30 on 60/B0 AW DMC3 chromosorb W with column-oven, injector and detector temperatures maintained at 225, 280, 380 respectively. The flow of helium was 24q mls/min.
To confirm that the peaks used for area calculation were indeed the same peaks designated on the EC-OC treeing, fractions from TC-OC, corresponding to those peaks were collected. Re tention times relative to , g'-DDE were identical to those of the Aroclor a.
RESULTS AND DISCUSSION
Figure 1 Illustrates the EC-GC profiles of the Aroclors, while Figures 2 and 3 represent the TC-GC profiles. Peaks are identified by letters (a through t) for later reference. The samples from which the figures were produced and which will be used in subsequent investigations were supplied by Monsanto Chemical Company (Electrical Grade, Lot Numbers: 1242, KB-05-415; 1254, KB-04-612). These samples differed slightly from other
Jlip^
111
mi
mM
ft#?!
11J.
^
,,'; V" V'J-,
C ;, ':
.*.. Jr-,\"r;
M0NS 081<,a4
">. -T '
* .-
..
Peak
a b c d e f 1 h 1 j k 1 a n 0 P
Table I Peak Composition and peak contribution to total Aroclor 1242
HUT1)
13 21 26 31 37 41 18 53 57 70 61 99 105 127 149 176
Per cent composition of peak
* Total
l-Cl
2-C1
3-Cl
4-C1 -Jbi_ PCB
100 -- -- -
T
2.7 97.3 -
--
- 100 - - -
- - 100 - -
0.5 3.4 8.8
- - 100 - - 15.5
--
90.3
9.7 -
5.7
--
au.2 75.8 -
27.4
--
26.9 73.1 -
11.0
--
3.8 96.2 -
11.5
-
-
-
13.9 86.1
9.0
-
-
-
11.6 88.4
4.2
---
3.9 96.1
1.1
- - - - 100 1.2
- - - - ND 0.5
- - - - ND 0.3
-- -- -- - ND
T
tmi m'ft
.*>.-
...
V- >
wwwii)iww.jfmrtmn
;'-A/v:-;
\:A- - '-''.V.'
MONS 001486
nim1
" '<:'`rii
' ,-v'
i.V.7 *' -n-iiZi
Table II Peak Composition ana peak contribution to total Aroclor 125U
Peak
RRT1)
-> ,,,Per cfnt COBV*ition of peak
----- --------------- !tzi____ 5-Cl
6-Cl
c 26 - - --
JO)
d 31 -- -- -
KD
e 37 f 4l -
-
-- KD KD
8 46 --
100 --
-- ..
h 53 3.8
96.2 -
-- __
i 57 3.8
96.2 --
-- ..
j 70 1.7 h 64 --
98.3 96.8
3.2
--
--
..
1 99 105
-- "
--
100 97.3
2.7
n 127 0 149
--
-
87.5 77.6
18.5 82.4
..
P 176
-
--
5-5 94.5 ..
q 208
--
-
12.0 88.0 __
r 253
--
-
-
75.7
84.3
8 286
--
-
-
-- 100
t 338
-
--
-
-- KD
% Total
T T .2
2.0 1.0 0.8
16.1
16.4 20.2
16.7
13.7
8.2 2.1
1.9 0.6
T
mi
^jv | ftf
1 Total PCB
r T
.2
2.0 1.0 0.8 S.l 3.4
>.
*.7 .7 .2 .1 1-9
samples obtained from Monsanto and from the lots (not designated by number) analyzed by WEBB and McCALL (in press). The indus trial process by which Aroclors are produced will introduce minor variations between lots; these variations, however, are small compared to the profile changes introduced when the PCB is subjected to light and/or biological systems (COOK 1972; WELBORN ei aj., in press; BORCHARD et al., in press).
Tables I and II show quantitative comparisons of the Aroclors based on TC-CC and GC-MS determinations. The composi tion of the peaks In terms of the number of chlorine atoms as well as the percent contribution of each peak to the total PCB are presented. Thus, in Lot KB-05-415 of Electrical Grade Aroclor 1242, peak g is the predominant component, constituting over 27 percent of the total PCB; It is composed of 25 percent trichloro- and 75 percent tetrachlorobiphenyls. On the other hend, in the Aroclor 1242 examined by WEBB and McCALL (in press), component g (RRT 47) constituted less than 9 percent of the total PCB and was composed entirely of tetrachlorobiphenyls as is the same peak in Aroclor 1254. The synsetrical analog, 2,21,5,5'-tetrachlorobiphenyl, has been confirmed aa the major component of this peak (WEBB and McCALL, 1972).
In Aroclor 1254, the major components are peaks J through p, primarily tetra-, penta-, and hexa- chloro-biphenyla, As might be expected, the analog composition of peaka with the same retention times varies from Aroclor to Aroclor as well as from batch to batch (TabletI and II); thus, rates of metabolism or accumulation of components (peaks) may be expected to change as peak composition is altered by the biological systems. Blood levels of peaks k and o, for example, parallel each other up to fifteen hours~after~administration of an l.v. bolus of Aroclor 1254 to sheep; changes in rates of disappearance between 14 and 24 hours, however, result In the reversal of relative concen trations of the two components (BORCHARD et al., in press).*
ACKNOWLEDGMENTS
This work was supported by funds from the Department of Health, Education end Welfare, Pood and Drug Administration, Bureau of Veterinary Medicine, Contract No. FDA 72-116.
The authors would like to thank Monsanto Chemical Company for supplying the Aroclor samples and for their advice and assistance on analytical procedures. Dr. E. B. Perkins and E. W. Mayhood for running the mass spectral analyses, snd Dr. R. P. Hyatroa for Ms cooperation and suggestions.
MGN5 0014ad
REFERENCES
BORClttRD, R. E., L. G HANSEN, W. 0. HUBER, R. L. METCALF, and
M. E. WELBORNr Arch. Environ* Contaa. Toxicol*. In press.
COOK, J. w.: Environ. Health Perspec. 1, 3 (1972).
HUTZINGER, C., W. JAMIESON, and V. ZITXO: Nature 226 , 66b (1970).
ROTE, J. w. and W, J. M3RRIS: J. A. 0. A. C. 6, 155 (1973).
ROTE, J. W. and P. MURPHY: Bull. Environ. Contaa. Toxicol. 6,
377 (1971).
~
SISSONS, D. and D. WELTIt J. Chroaatogr. 60, 13*
STALLING, 0. and J. HUCKIWSi J, A. 0. A. ST 5b, 801 (1971).
WEBB, R. 0., and A. C. McCAU: J. A. 0. A. C. 5^. 7^6.
WEBB, R. 0., and A. C. McCALL. J. Chroaatogr. Science, in press.
WELBORS, M. B., R. t, EORCHARD, L. G. HANSEN, and R. L. METCALF:
Bull. Environ. Contaa. Toxicol., in press.
i
A-'