538 CHAPTER 36 1960 Guide Table I____ Minimum Stack Areas for Oil and Stoker-fired Boilers" RECTANGULAR ROUND CoL 1 /= Banter Capacity (Net Overt Cal CoL 2 Nottfcwrf Stack Dimensions tft. CoL 3 Inside Dimensions of Umr In. CoL 4 (4=8 Burner Capacity (Not Over) Gal Col. S Inside Diameter of Liner In. 2.1 3.5 5.3 7.7 11.5 8X8 8 X 12 12 X 12 12 X 16 16 X 16 6* X 6* e* x iom %x 9K 9* X 13* 13* X 13* 1.3 1.8 2.5 4.5 5.6 6 7 8 10 11 15 16 X 20 13 X 17 7 21 20 X 20 16* X 16* 12 26 20 X 24 16* X 20* 19 33 24 X 24 20* X 20* 28 41 24 X 28 20* X 24* 40 12 15 18 21 24 52 28 X 28 24* X 24* 53 59 30 X 30 25* X 25* 69 76 30 X 36 25* X 31* 88 100 38 X 36 31* X 31* 109 27 30 33 36 . * Table E, Put 11 erf Tcotmt and Ratint Coda for Lee Prtosttro Cast Iron Hcatutt Bede* (1958). Tbe inside dimensions or diameter ot liaer shown in Cols. 8 or S en (or cbimmey* lined with standard day chimney tile end ere the largest standard sixe that will fit within the dimensions specified (or un- iaed chimney. deucy of different models, the possibility that soot on the lining will restrict the chimney area, and the variation in combustion air requirements of different solid fuels. Figs. 6 and 7 show that a given chimney produces a maximum avail able draft and a effidency for some intermediate muss flow rate for any selected inlet flue gas temperature. For mafia flow rates lower than the optimum the greater cooling of the gases in the chimney causes lower available draft, whereas for mass flow rates above the optimum the greater friction losses reduce the available draft. A chimney Rg. 9- . .Ideal Draft for Short Chimneys at Outside Temperatures of 0 F and 60 F for a given heating system should probably be designed to operate at its point of wMimnm efficiency and maximum available draft for its full rated output. A chimney would have an accelerating effect" on the combustion rate of a solid-fuel burning device if it were operating to the left of the optimum point in Fig. 6 because an additional increment in mass flow rate would increase the available draft a small amount and tend to increase the mass flow still more. On the other hand, a chimney operating to the right of the optimum point in Fig. 6 would tend to decelerate the combustion rate for any small increase in mass flow rate. Data are not complete for the selection of proper chimney areas for heating plants of different capacities, but some in formation on the effect of cross-section area on the capacity of masonry chimneys is provided by tests*' u on several chim neys with liners having nominal outside dimensions: 9-in. diameter, 12-in. diameter, 9 x 9-in., and 9 x 13-in. These tests showed that for flue gas rates up to 200 lb per hr, and entering flue gas temperatures from 200 to 1000 F, the 9-in. round liner provided an available draft equal to, or greater than, that produced by the other three larger liners. When the flue gas rate was increased to 320 lb per hr, the three larger liners produced a little more draft than the smallest one for entering flue gas temperatures above 600 F. Other data* show that metal chimneys with an internal diameter of 6 in. should not be used for mass flow rates greater than 130 lb per hr. Table 3 shows approximate values of the mass flow rates and flue-gas velocities at the chimney inlet that produce the maximum available draft for masonry chimneys* of several conventional sizes and with an effective height of 15 ft. This table shows that a 9-in. round chimney is best suited to mass flow rates from 130 to 170 lb per hr, a 9 x 9-in. chimney Chimneys and Draft Calculations 539 Table 2 .... Efficiency of Short Chimneys A. Masonry Chimneys Internal liner Size, in. Height Hue Got h How Rete 11 ft tb/br 7 (dial 7.7 / x II and 10 (dial urti 5 to 15 Effidency, Percent 90 75-82 65-76 65-80 200 83-84 67-85 82-88 315 75-89 67-86 81-89 (Inlet Flue Gas Temp. 200 to 1000 F) B. Jninsutated Metai Chimney* J(11 r 1_! Height fl 4 to 8 Hoe Ga* Flow Rate Ib/hr 90 200 315 Internal Diameter, in. 16 B Effidency, Percent 90-100 1 85-95 83-88 70-80 (Inlet Flue Gas Temp. 200 to 600 F) C. Metal Chimneys* rrr Jr[jT [f Height J Uninsulated 1-in. Insulation with dead air space around chimney 1-in. Insulation with 1-av open air space around chimney Efficiency, Percent 8 to 14 76 85 81 * Sit-inch chimney net recommended (or these flow Kite. * Internet die 6-in.; flue pa flow rete SO to 1JS lb/hr; inlet flue pa temp. 800 to (000 P. Table 3.... Approximate Flue Gas Bow Rates for Maximum Available Draft in Masonry Chimneys Hue Cat Temperatvre at Chimney Iniet, F Nominal interne/ Area 200 External liner of Liner Dimensions, fa. Sq. la. 600 IOOO Mass How Rate, Ib/Hr 20o|dOO IOOO Hue Gas. Velocity at Chimney Met, 9 (dia) 9x9 12 (dia) 9 x 13 38.5 49 78.5 77 170 150 130 215 306 334 290 Above Above 320 320 295 Above Above 320 320 175 250 300 175 4QC 600 150 -- -- 150 height or chimney area may be a contributing cause, but smoky combustion with coal is related to fuel characteristics and firing methods. Therefore, an increase in chimney area will usually not cure smoky combustion of a coal-burning device, but can be expected to lengthen the interval between cleanings. New standard sizes of clay flue linings were developed by the industry and approved by the American Standards As sociation, in order to effect economies that can be derived from coordination of the dimensions of building materials. These linings are known as modular clay flue linings, and the dimensions and tolerances are summarized in ASA Standard A62.4-47. As the effective areas of these liners are somewhat smaller than those of the corresponding linings used pre viously, they cannot be used in certain municipalities where building codes specify minimum areas based on tbe older dimensions. DRAFT REQUIREMENTS OF APPLIANCES Typical flue-gas temperatures and drafts required at rated output for several kinds of domestic heating appliances0 are contained in Table 4. Chimney height and chimney area for performs best for flow rates from about 200 to 300 lb per hr, and 9 x 13-in. and 12-in. round chimneys are best suited to flow rates above 300 lb per hr. These results were obtained with clean chimneys, so that conclusions about chimney areas require some modification if soot deposits are taken into con sideration. Soot deposits in chimneys reduce the effective area of the liner and may in some cases entirely close the passage. Soot deposits are'likely to be greater in the horizontal passages in the heating plant, the breeching, and the smokepipe, than in the vertical chimney liner. An increase in the liner diameter of one inch. above that required for a clean chimney will probably make adequate allowance for soot deposits in all but the worst cases. Where smoky combustion is likely to occur and the mass flow rates on a clean chimney basis ap proach those listed in Table 3, the next larger commercial size liner should be used. Smoky combustion with oil-burn ing devices, particularly with vaporizing oil burners, is likely to be caused by inadequate draft which is often due to insufficient chimney height. For coal, inadequate chimney FUlC CAS FLOW-POUNDS PCT HB 7.05 (b per gaf, 60 f. Fig. 10.... Graphical Evaluation of Rate of Flue Gas Flow from Percent CO* and Fuel Rate*