Document Rjn3gpNo2Oq5br2YQE9nDEy27
PLAINTIFF'S EXHIBIT
BuDiac' Telecommunications Industrial Hygiene Survey Kit
AftT
Bell Laboratories
late January 26, 1985
i>om. Charles P. Lichtenwalner MH 77621 1F-110 X5399
MEMORANDUM FOR FILB
This note details procedures for conducting an industrial hygiBne survey using the telecommunications industrial hygiene survey kit. This kit has been assembled to assist safety coordinators to respond to health or environmental complaints by performing a survey of conditions.
Hi?'a and procedures for use of the equipment are given in tl ppendices to this memorandum.
Appendix A: Equipment and Procedures for Sampling Various Substances
Appendix B: Measuring Noise Exposure (OSHA Dose)
Appendix C: Calibration and Use of Colorimetric Detector Tubes and Pumps
Appendix D: Calibration and Use of Personal Sampling Pumps
Appendix E: Wet wipe Sampling Procedures for PCBs
Appendix F: Parts List for Telecommunications Industrial Hygiene Survey Kit
Additional equipment that may prove useful:
1. A camera (preferably instant) to document conditions.
2. Manuals of equipment and a sampling manual such as this note and the attached exercises from the REOHH courses.
3. Appropriate detector tubes for any gases or vapors to be sampled.
LLA 001476
Memorandum for File - 2
Note that the techniques liBted in Appendix A may not always be the best or most accurate methods available but they are usually adequate for screening or to assess the extent of the problem.
MH-77621-CPL-jve
Copy to: J. L. Stuart ATST-C
S. R. Bagels H. R. Fitch M. Glowatz W. J. Schreibeis G. M. WilJcening
Charles P. Lichtenwalner
LLA 001477
APPENDIX A Equipment and Procedures for Sampling Various Substances
Substance
Equipment
Notes
Asbestos (bulk)
MSA pump Millipore AA filter
Collection tubes
Plow rate about 2 L/min. at least 2 hour sample. Do not use numbered filters - they are PVC.
To avoid exposure while sampling take a wet sponge with hole cut in middle same diameter as tube. Press wet sponge against ceiling then insert tube through hole and with screwing motion pierce insulation and cut out a core of material into tube.
REDACTED
LLA 001478
OUMtoa ad Ito cf Pmul Sanglng Props
The Sow rite can be detennised only through ctlibradcn d the swropting pump.
The cammrt imtrwauauioo and ttxppiia used for wad mnpSag by Btntian are dscrbed below.
A fi'/frr Cassette
The filter assent, a an assembly with three baok aaspanatv
-- Sampling FOts
-- Back Up Pad
-- Rlter Holder (Cassette)
The--Star maty be on? of several material types mrfmfiy
-- Mixed Cdhdaae Ester Fitters QACEF) -- GLua Fiber FQtm
-- Polyvinyl Chloride (PVC) Filters
-- SbmbSeaistmmHtan
They may also be of various pare axes end dbuoetm.
The cuaette may haw two a three para or stage*- The two stage caaette a toed only far dawd tee Mttqiing; the three date caaette may be toed either daed a open face mode.
The seketkn of the type of Star, the Wf pore ahs, aid the --mfifag wnfc (open or dosed face) wO depend on the rnntamioaot rotgiod
Far --had sod mbeem, a eobced cafiukae ester Stsr with a tiametrr cf 37 mm is required. The fiber b mounted hi a cassette with a back up pad. Sanp&tg most be conrinctwl daad tee for ked (2 or 3 sage cassette) and qpea face for mtsema (3 stage cassette aaly).
B. Sampling Pump
Btftcsy cpcnttiSd dfaipfcnjpj jpocopj dUfld pcxsooBi
puDUVy fb ousd to draw m
forcugt the Star which then tnpi the particles. Mat panaul umpifog pumps win operate
fat up to 9 hows sampling time befere needmg rwfcargfag. Rccfaargiag time b usually
owmigbt (16 hours). The pump must be capable of pulling a hast 2 liters of sir per minute
through foe fiber. A rotameter (or flowmeter) cn foe ride cf meat pomps can be used to
deunoiae foe flow rate st which foe pump b operating.
faktii GaUhrathm of Swaging Ptaxpa
Calibration is foe proas* by which foe flaw rets ccirespaxSqg to each pump tviaraeia setting is /twmineri The pnp irtamnar may be calibrated a using primary or secondary standard. The soap meter a a primary standard, and calibration using this method mvohts (fired mtnarrmemrx of volume end time. Secondary standards such as prerisiaa rotametas are reference rmtrunvntv which asst be periodically calibrated agsiat a primary standard.
APPENDIX F
Parts List for Telecommunications Industrial Hygiene Survey Kit
Parts List
2100 Supplier - MSA Cost: $513 (412)273-5000
Part No. Purpose
459054 MSA Tube Holder 456226 Sampling Line Assembly 466117 Portable Pump Assmebly Model G 456059 Battery Charger Assembly Sampling Lead, Asbestos, Metals, Sulfuric Acid Mist, Solvents, PCBs
Part No. 31968 Sling Psychrometer Purpose Temperature and Relative Humidity
3900 Supplier - Dupont Cost: $936
Part No. Purpose
2639 10 Charcoal Tubes 109/100 2641 10 Florisil Tubes 54/50 Sampling for Solvents, PCBs
Part No. 5300
Mark 1 Audio Dosimeter 925
Purpose A-weighted Noise, OSHA Noise Dose
350 Supplier - Gilmont Cost: $85
Part No. P2260 No. 12 Compact Shielded Rotameter Purpose .Calibrate Sampling Pump
700 Supplier - National Draeger Cost: $150 (412)273-8383
Part No. Purpose
6726065 Model Jl Gas Detector Pump
Sampling for variety of gases or vapors must be ordered for each substince before sampling due to limited shelf life.
Supplier - Millipore Cost: $10
Part No. Purpose
MAWP037 Six 0.8 urn MCEF Filters Sampling Lead, Asbestos, Metals, sulfuric Acid Mist
Supplier - Clayton Cost: i-50
Purpose
3 Pre-weighted PVC Filters Sampling for Total Dust
LLA 001480