Document RjjnY60Nd4nq5KV8jB957Ok5X
ELEVATORS AND PLANT RAILWAYS
should meet the requirements of existing state laws for ladders except that an en closing cage should not be provided since the ladder should be accessible from either side throughout its entire run
Inspections
Every manlift should be tested and in spected at least every 30 days On discovery of a defect, the manlift should be put out of operation immediately and not used until re paired Each penodic inspection should cover, but not necessarily be limited to, the following items
Steps Step fastenings Rail supports and
fastenings Rollers and slides
Belt and belt tension Handholds and fas
tenings Floor landings Guardrails Electric switches
Lubrication Warning signs and
lights
Signal equipment Dnve pulley
Bottom (boot) pul
ley and clearance
Pulley supports Motor Driving mechanism Brake
The safety mechanism of a manlift should be inspected daily for free operation and for accumulations of dirt and grease A man lift should be completely dismantled once every three years and defective or exces sively worn parts should be replaced
General precautions
The maximum speed of a manlift belt should not exceed 30 fpm and should be uniform on all mankfts throughout the plant If the lift carries a great deal of traffic, a maximum speed of 60 fpm is rec ommended
Floors should be numbered m large fig ures in full view of both ascending and de scending nders A constantly illuminated sign, reading in block letters at least 2 in high "Top Floor--Get Off," should be con spicuously placed not more than 2 ft above the top landing, in full view of an ascending passenger If such a sign is not used, at least a 40-watt red light should be so lo cated immediately below the top landing as to shine in an ascending rider's face
Signs carrying instructions for use of the manlift should be displayed prominently at
each landing. Only employees should be
permitted to nde manlifts, and signs so stat ing also should be displayed at each landing.
The entire manlift should be illuminated at all times while it is in operation, with at least 1 foot-candle at all points and at least 3 foot-candles at landings
Nothing that cannot be placed entirely in side a pocket or in a sling or pouch should be earned by a nder on a manlift Tools may be earned in a leather-bottom canvas bag not larger than 11 by 13 in and pro vided with carrying loops or handles While nding the manlift, the passenger should hold the bag m his hand
Employees, particularly new ones, should be carefully instructed in safe use of the manlift and should be cautioned to report immediately any defects or irregularity ui operation of the manlift or the safety de vices
Plant Railways
Clearances and warning methods
Insofar as possible, plant railway hazards should be eliminated m the design of a new plant Horizontal and vertical track clear ances are primary considerations
It is recommended that m this and all other phases of track construction, AREA standards" be adopted, provided municipal, state or federal regulations do not conflict Fig 19-13 shows AREA recommended clearance standards
Where platforms, building entrances, or structures are located along curved track, additional clearance must be allowed on both sides of the curve for lateral movement of cars and loaded flatcars at center and at ends
Additional track clearance must be al lowed also when awning or jalousie win dows are installed in adjacent buildings
Close clearance warning signs should be placed at points where buildings or other obstructions are so close to a track that they will not clear a moo riding on the side of a car Side or overhead telltales some times are installed to give positive warning of approach to structures with close clear ance
4Association of American Railroads, En gineering Division (American Railway En
gineering Association), 59 East Van Buren
St, Chicago, 111 Manual of Recommended Practice
19-24