Document RjMmO4nB98NKKvaqYMy8N6nrv
design manual
1970
EDITION
DSW 433901 STLCOPCB4087007
CONTENTS
Section 1
Page
1. Why use Santotherm...................... ............................................ 2. The Santotherm Range.............................................................. 3. Santotherm - Application Unlimited...................................
1 2 4
Section 2
1. High Performance Fluid - Santotherm 55...................... 2. High Performance Fluid - Santotherm 66...................... 3. High Performance Fluid - Santotherm 88...................... 4. Fire Resistant Fluid - Santotherm FR-LO-TEMP ... 5. Fire Resistant Fluid - Santotherm FR-0........................ 6. Fire Resistant Fluid - Santotherm FR-1 ........................ 7. Fire Resistant Fluid - Santotherm FR-2........................ 8. Special Purpose Fluid - Santotherm 77............................. 9. Special Purpose Fluid - Santotherm 130........................ 10. Special Purpose Fluid - Santotherm 190........................
6 10 14 24 28 32 36 44 48 52
Section 3
1. General Design Hints for Santotherm Systems............. ..
2. Typical System Layouts ..............................................................
3. Suggested Start-Up Procedure for New Systems...............
4. Suggested Operating Instructions
...................................
5. Units Conversion Tables..................................................... ..
59 66 70 72 77
DSW 433902
STLCOPCB4087008
'
1.
WHY USE SANTOTHERM? More than 2,500 customers have specified Santotherm for new installations and conversion of existing systems in Europe and the U. S. A. The main reasons they chose Santotherm were:
Safety Santotherm systems operate at or near atmospheric pressure in the liquid phase. Working at atmospheric pressure means safer systems.
In applications where the risk of fire has to be minimised the Santotherm FR fluids are chosen because they bring the added benefit of fire resistance (together with approval from Factory Mutual U. S. A., and certification as fire-resistant by Underwriters' Laboratory. Lower Capital Costs Without pressure you can usually save 25 to 50 % of your capital because you don't need heavy piping, relief valves or other devices associated with pressurised systems.
Lower Operating Costs Very little fluid make-up is normally required. Temperature and heat losses expected with vapour systems are very much reduced. Routine maintenance is minimised and expensive operating personnel needed for pressurised systems are often unnecessary.
Santotherm is a Registered Trade Mark.
DSW 433903
STLCOPCB4087009
2.
THE SANTOTHERM RANGE . ..
... offers you a series of heat transfer fluids covering the operating range - 73C (-100 F) to 427C ( 800F). And for the future as your process temperature demands change you can choose a new Santotherm fluid to match your new needs. Many of the Santotherm fluids are interchangeable in your liquid heating system.
The Santotherm range includes ten fluids falling into three groups.
Santotherm 55 Santotherm 66
Santotherm 88
) j
.)
High Performance Fluids
Santotherm FR-LO-TEMP )
Santotherm FR-0
j
Santotherm FR-1 Santotherm FR-2
) ^
Fire Resistant Fluids
Santotherm 77 Santotherm 130 Santotherm 190
) | Special Purpose Fluids
)
DSW 433904 STLCOPCB4087010
. `css^rssr.-
THE SANTOTHERm RANGE OF HEAT TRANSFER FLUIDS
=_ STE`:?* r,, ` 'fHigh Perfprmance Fluids '
..... Fire-Resistant Fluids
P"" f -
'
[ Special Purpose Fluids
C 140 420
.. 400 1
1 380 i
360 ISSlIjig 340 ; 320 i 300 280 260 240
220
200 180 160 v
140 120
100 80
60 ? 40
20
o :
-20
-40 ' -60 " -80
C
m.jAi yJAtljtkn.il
- 2J- t-- -J-Ls.*-2. -- t
PHI I
pjjlSi liSS
CO CO
I O _ CJ gplppl
CO : 0* 3
*
! LU
1<c CO CO CO CO CO
CO
Slilii&sislsj isss
DSW 433905
HHp
-
`0H
STLCOPCB4087011
4.
SANTOTHERM - APPLICATIONS UNLIMITED
CHEMICAL PROCESSING ... especially where flammable materials are handled. Santotherm has proved particularly successful for heating reactors, autoclaves, heat exchangers distillation columns, reboilers, mixers, dryers etc.
RESIN PROCESSING ... where a single "circuit" with multiple users and varying temperatures is desirable.
PLASTICS AND RUBBER MOULDING; PAPER AND TEXTILES ... where uniform heating, rapid temperature flux and pint-point control is essential such as heating corrugating and drying rolls, crimping presses, calendars, platens and moulds.
FOOD PROCESSING ... for controlled, quality "cooking" of potato chips, pre-cooked/ frozen products, other foodstuffs.
PETROLEUM AND OFF-SHORE DRILLING .. . offers control over a wide temperature range and the ability to accommodate sudden fluctuations in processing loads automated with complete safety.
SHIPS AND BARGES ... eliminates expensive boiler operators with a system that can heat fuel, cargo and living quarters.
SPACE HEATING ... ideal for hospitals, hotels, apartment houses and office buildings where the goal is safety, low maintenance and reduced operating costs.
DSW 433906
STLCOPCB4087012
Section 1
DSW 433907 STLCOPCB4087013
HIGH PERFORMANCE FLUIDS Santotherm 55 Santotherm 66 Santotherm 88
DSW 433908 STLCOPCB4087014
6
HIGH PERFORMANCE FLUID - SANTOTHERM 55
MAXIMUM BULK OPERATING TEMPERATURE
315C 600F
RECOMMENDED MAXIMUM FILM TEMPERATURE 335C 635F
Santotherm 55 is a synthetic heat transfer fluid developed for use in non-pressurized, indirect heating systems. Added to the extensive Monsanto line of heat transfer fluids to meet exacting needs, Santotherm 55 demonstrates thermal stability superior to that of petroleum oils.
Non-pressurized liquid systems using Santotherm 55 - type fluids are finding increasing use in applications which traditionally used steam as the heating medium. Savings in capital and maintenance costs are often gained.
DSW 433909 STLCOPCB4087015
9 9 ........... *
......V ' '
-------- ' /
HIGH PERFORMANCE FLUID - SANTOTHERM 55
TYPICAL PHYSICAL, CHEMICAL AND THERMAL PROPERTIES
. Composition Appearance
Synthetic hydrocarbon
Clear, brown liquid
Odour
slight
Coefficient of Expansion C F
0.00085 0. 00047
Density at 25 C (77F) kg/m;?
lb/ft 3
885 55.2
Boiling Range
C F
Pour Point
C F
335 - 390 635 - 734
- 29 - 20
Flash Point, Pensky-Marten (ASTM-D93 - 46) C
F
180 355
Fire Point (Pensky-Marten)
C o
F
Autoignition Te mperature o C o
F
210 410
354 670
Viscosity at 0C cS
300 ....... ..............
4339i 0
STLCOPCB4087016
Santotherm 55 Variation of properties with temperature
t
KG/M'
KCAL/KGC -->
KCAL/M. H R .C --*-
c --
DSW 433911 STLCOPCB4087017
i--------
Santotherm55 Kinematic Viscosity
1000
100
t
VISCOSITY CS
-20 0
DSW 433912 STLCOPCB4087018
' Santotherm 55 Vapour Pressure
'. v I
9.
HIGH PERFORMANCE FLUID - SANTOTHERM 55
System Design Hints ( see also Page . 59...) Santotherm 55 contains no additives. Its compatibility with materials of construction is similar to petroleum oil - use of copper should be kept to a minimum.
To reduce fluid oxidation the expansion tank temperature should be kept below- 38 C (100 F ); otherwise an inert gas blanket should be used.
Fluid Maintenance ( see Page . ?9... )
Safe Handling of Santotherm 55 ( see Page
)
DSW 433914
_Jt STLCOPCB4087020
10.
HIGH PERFORMANCE FLUID - SANTOTHERM 66
MAXIMUM BULK OPERATING TEMPERATURE
343C 650F
RECOMMENDED MAXIMUM FILM TEMPERATURE 371C 700F
Santotherm 66 was developed for use in non-pressurized systems. As a result, the capital costs of a Santotherm 66 system are generally lower than a diphenyl/diphenyl oxide system.
Santotherm 66 can also be used as top-up in liquid phase diphenyl/ diphenyl oxide systems. Addition of 15 % of Santotherm 66 will depress the solidification point of the eutectic to around -9C (15F).
Santotherm 66 is being used in Europe and the U. S. A. for the following applications:
Resin manufacture Sodium processing Phthalic anhydride distillation Deodourising of fatty acids Polyamide extruders Polyethylene manufacture Waste heat recovery Polyester manufacture Insecticide manufacture
DSW 433915
-
STLCOPCB4087021
HIGH PERFORMANCE FLUID - SANTOTHERM 66 TYPICAL PHYSICAL, CHEMICAL AND THERMAL PROPERTIES
h_.
Composition Appearance
Odour
Coefficient of Expansion C
F
Density at 25 C (77F) kg/m3
lb/ft 3
Boiling Range
C F
Pour Point
C F
Flash Point, Pensky-Marten (ASTM-D93 - 46) C
F
Fire Point (Pensky-Marten)
C 0
F
Autoignition Te mperature o C o
F
Viscosity at 0C cS
Synthetic hydrocarbon
Oily liquid practically colourless
faint characteristic
0.00070 0.00039
1005 62.7
340 - 396 644 - 745
- 25 to - 28 -15 to-18
179 - 180 354 - 356
190 - 200 374 - 392
374 705
800 STLCOPCB4087022
DSW 433916
KG/M5
KCAL/KG C --
Santotherm 66 Variation of properties with temperature
STLCOPCB4087023
KCAL/M. HR. C --
3
3
3 3
Santotherm 66 Kinematic Viscosity
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
>
3
VISCOSITY CS
? 3 > #
V
>
DSW 433918 STLCOPCB4087024
Santotherm66 Vapour Pressure
0.001
DSW 433919
400 STLCOPCB4087025
13.
HIGH PERFORMANCE FLUID - SANTOTHERM 66 System Design Hints ( see also Page . ,5.9... ) To minimise fluid oxidation Santotherm 66 systems should be blanketed with nitrogen unless the fluid in the expansion tank can be kept below 38C ( 100F ). Copper and its alloys should be used sparingly as materials of construction.
Fluid Maintenance ( see Page . ?P... )
Safe Handling of Santotherm 66 ( see Page . 21... )
DSW 433920
STLCOPCB4087026
t * /A -A f / '
14.
HIGH PERFORMANCE FLUID - SANTOTHERM 88
V1AXIMUM BULK TEMPERATURE
425C 7 95F
IE COMMENDED MAXIMUM FILM TEMPERATURE 435C 815F
Santotherm 88 is a fluid for high temperature operation in the liquid phase. Santotherm 88 is a solid material which melts at 145C ( 293F ) to become a thermally stable fluid for use in high temperature chemical processing plant. Santotherm 88 is the latest addition to the Santotherm range and should be considered for applications at present using molten salt.
DSW 433921
STLCOPCB4087027
-dru.'.i/.a .yVa..*!... *.
15.
HIGH PERFORMANCE FLUID - SANTOTHERM 88 TYPICAL, PHYSICAL CHEMICAL AND THERMAL PROPERTIES
Composition Appearance
Odour
synthetic hydrocarbon
Wax-like flakes at ambient temperature Light amber liquid above melting point.
faint, pleasant
Coefficient of Expansion
C o
F
Density at 25C (77F) kg/m lb/ft
Boiling Range
C F
Melting Point begins to soften at...................................... completely liquid at........................... ..
Viscosity at 149 C 300 F cS
Flash Point, Pensky-Marten
( ASTM-D93 - 46 )
C
F
Fire Point (Pensky-Marten)
C F
Autoignition Temperature C 0 F
Latent Heat of Fusion
kcalAg BTU/lb
0.00085 0.00047
1133 (solid) 1020 at melt, point
70.7
63.7 ( 149 C)
364 - 418 687 - 784
60 C ( 140 F) 145C (293F0
1.6
191 375
238 460
above 538 above 1000
21.7 - 22.2 39.1 - 40.0
DSVV 433922
STLCOPCB4087028
HIGH PERFORMANCE FLUID - SANTOTHERM 88 VARIATION OF PROPERTIES WITH TEMPERATURE
16.
Tempe rature
Density
Specifi c Heat
Thermal Conductivity
Viscosity
F- *C. lb/ft3 Kg/m3 BTU/lb. Kcal/Kg. BTU/ft. hr. *F Kcal/m. hr. `C Ib/hr. ft
"F c
cP
cS
Vapour Pressure
mmHg Kg/cm2 absolute
300 149 63. 0 400 204 59.9 500 260 57.4 600 316 54.9 700 371 51.8 800 427 49. 3 900 482 46. 2
1010 960 920 880 830 790 740
0. 467 0. 49 7 0. 525 0. 554 0. 584 0. 613 0. 642
0. 467 0. 497 0. 525 0. 554 0. 584 0. 613 0. 642
0. 0738 0. 0712 0. 0686 0. 0660 0. 0634 0. 0608 0. 0581
0. 1077 0. 1060 0. 1021 0. 0982 0. 0943 0.0905 0. 0865
3. 84 2.20 1.24 0. 813 0. 584 0. 440 0. 341
1.585 0. 835 0.506 0. 335 0. 241 0. 1815 0. 1405
1.57 0. 87 0. 55 0.38 0. 29 0. 23 0. 19
1. 2 11 65 260 800 1500 3000
0. 00163 0. 0150 0. 0885 0. 354 1. 087 2. 04 4. 08
/
DSW 433923
STLCOPCB4087029
W ^ * #*'\ /.//:>_ \ :
Santotherm 88 Variation of properties with temperature
KG/M*
KCAL/KG C --
1000 900 800 700 0.700 0.600 0.500 0.400
0.110-
0.100 0.090 0.080
DSW 433924 STLCOPCB4087030
KCAL/M. HR. C --
STLCOPCB4087031
VAPOUR PRESSURE KG/CM2
Santotherm 88 Vapour Pressure
DSW 433926 STLCOPCB4087032
grtfwat"
17
HIGH PERFORMANCE FLUID - SANTOTHERM 88 SOLUBILITY IN MISCELLANEOUS SOLVENTS
Solvent
3A Alcohol..................................................... Turpentine....................... .............................. Fuel Oil, API 36, 38 S.U.S. at 100 F.. Benzene........ .................................................. Trichlorobenzene............................................ Stoddard's Solvent......................................... Nitromethane................................. ................ Nitroethane..................................................... 1- Nitropropane............................... .............. 2- Nitropropane..................................... ........
Grms. Santotherm 88 per 100 ml.of solvent
25 C.
75 C.
0.008 1.2 1.66 6.0 9.0 0.7 0.2 2.0 2.0 2.0
0.6 9.0 8.4
42.0 4S.0
8.0 7.5 15.0 20.0 20.0
DSW 433927 STLCOPCB4087033
HIGH PERFORMANCE FLUID SANTOTHERM 88
Heat Transfer Correlation
This equation and j-factor plot is adequate to approximately plus/minus 7%
.i . -i .* ,, r- i . h>'
mi
HEAT TRANSFER FACTOR, j
104 1 05 5X 10s
REYNOLDS NUMBER
DSW 433928
STLCOPCB4087034
19.
HIGH PERFORMANCE FLUID - SANTOTHERM 88 System Design Hints (see also Page 59)
A combination drop and pump tank is used to conveniently drain high melting point Santotherm 88 from the system. On shut-down the fluid is drained into the tank which is large enough to contain all the Santotherm 88 fluid in the system. The tank is fitted with heating coils to melt the fluid for start-up.
A submerged pump is used to circulate the molten Santotherm 88 to the user equipment.
Tracing of the external system can be accomplished if necessary with an auxiliary Santotherm system or with high pressure steam. The combination tank can be easily blanketed, filled and vented as required.
Draining the secondary system depends on the fluid used to melt the Santotherm 88 in the drop tank.
Copper and its alloys should not be used as materials of construction.
Fluid maintenance (see Page 20)
Safe Handling (see Page 21)
DSW 433929
STLCOPCB4087035
v *
w
** ij;* i.*
20.
HIGH PERFORMANCE FLUIDS - SANTOTHERM 55. 66, 88
Fluid Maintenance
Samples of fluid should be taken and tested every 3 months during the first year of operation. Afterwards, 6-monthly sampling is generally sufficient. Analytical procedures are available from Monsanto who will also comment on the results and advise in any corrective action required .
!
DSW 433930 STLCOPCB4087036
21.
HIGH PERFORMANCE FLUIDS - SANTOTHERM 55. 66, 88 Safe Handling Both animal toxicity studies and manufacturing and handling experience indicate that no special precautions are required in the handling of these products at ambient temperatures. Vapours on the other hand whilst not dangerously toxic can rise to discomfort and systems should be made as leak tight as possible. Repairs to leaks of hot fluid should be carried out under well ventilated conditions.
os***931
...t
STLCOPCB4087037
I
Section 2
DSW 433932 STLCOPCB4087038
22.
FIRE RESISTANT FLUIDS Santotherm FR-LO-TEMP Santotherm FR-O Santotherm FR-1 Santotherm FR-2
DSW 433933 STLCOPCB4087039
FIRE RESISTANT FLUIDS - SANTOTHERM FR SERIES
23.
Flammability in Heat Transfer Systems
Santotherm FR fluids are fire-resistant. To the design engineer, the factor of "safety" must be weighed as heavily as reliability and efficiency. The "flammability" of industrial fluids for applications such as heat transfer can be defined as the ease of ignition combined with the ability to propagate flame. Many apparent anomalies occur in judging fire resistance unless these two aspects are considered together. Nearly all organic liquids pyrolize or oxidize if exposed long enough to a suffiently high temperature. The tendency is inherent in the type of chemical bonds. Volatile oxidation products can be formed which are flammable. The judgement of a fluid being "fire-resistant" - unless based on a number of applicable and accepted fire resistance tests - can be unfounded and dangerous. Not one test ( other than the actual use and proof of safety in a service failure ) can indicate the degree of fire resistance of a fluid nor the degree of fire resistance required for a given application.
The fire resistance of Santotherm FR fluids has been evaluated using
the following tests
.
High pressure spray-test Low pressure spray-test Hot manifold test Wick test
.
Results obtained in these and other tests have enabled Santotherm FR fluids to be listed as fire-resistant by Underwriters Laboratory Inc. USA. and approved by Factory Mutual.
Santotherm FR fluids are recommended for use whenever the risk of fire
has to be minimised.
DSW 433934
STLCOPCB4087040
?*
v A * ' J*vv* i . F> " 4.' - _ \..V. *w .
A 4 .j*.*: .. V v
24.
FIRE RESISTANT FLUID - SANTOTHERM FR-LO-TEMP
MAXIMUM BULK TEMPERATURE
205C 400F
RECOMMENDED MAXI MUM FILM TEMPERATURE
316C 600F
Santotherm FR-LO-TEMP can be used in a wide range of applications such as space heating and cooling, gas processing and distribution and industrial heating/cooling under conditions of low ambient temperature. A recent application is marine heating in Arctic conditions.
0S\N 4339^5 STLCOPCB4087041
FERE RESISTANT FLUID - SANTOTHERM FR-LO-TEMP TYPICAL PHYSICAL, CHEMICAL AND THERMAL PROPERTIES
Composition' Appearance
Chlorinated hydrocarbons
Pale, yellowish liquid
Odour
characteristic
Coefficient of Expansion C F
0.000513 0.000285
Density at 25 C (77F) kg/m3
lb/ft 3
1440 89, 9
Boiling Range
C F
Pour Point
C F
222 - 331 432 - 627
-51 -60
Flash Point, Pensky-Marten (ASTM-D93 - 46) C
F
138 280
Fire Point (Pensky-Marten)
C 0
F
Autoignition Te mperature 0 C o F
None to boiling
over 593 over 1.100
Viscosity at 0C cS
16
*2?
STLCOPCB4087042
Santotherm FR-Lo-Temp. Variation of properties with temperature
STLCOPCB4087043
VISCOSITY C S ^
STLCOPCB4087044
Santotherm FR-Lo-Temp. Vapour Pressure
DSW 433939 STLCOPCB4087045
27.
FIRE RESISTANT FLUID - SANTOTHERM FR-LO-TEMP
System Design Hints
( see page .. 39.. )
Fluid Maintenance
( see page . ,4Q . . )
Safe Handling
( see page . .4T.. . )
DSW 433940 STLCOPCB4087046
FIRE RESISTANT FLUID - SANTOTHERM FR-0
28.
:f
4" i
f
-!;
K
!
i
MAXIMUM BULK TEMPERATURE
260C 500F
RECOMMEINDED MAXIMUM FILM TEMPERATURE 316C 600F
Santotherm FR-0 was developed specifically to eliminate freeze-up during cold weather shut down for in-transit heating of sulphur, pitch, asphalt, naphthalene, heavy fuel oil and high melting point resin materials. Santotherm FR-0 eliminates the need for high temperature reheating in order to pump out the material at its destination.
DSW 433941
..
STLCOPCB4087047
Mf ili ii''nAJ--
FIRE RESISTANT FLUID - SANTOTHERM FR-0 TYPICAL PHYSICAL, CHEMICAL AND THERMAL PROPERTIES
Composition Appearance
Chlorinated, hydro carbons
Pale, yellowish liquid
Odour
1 Characteristic
Coefficient of ^Expansion C F
b'
Density at 25 C (77F) kg/m3
lb/ft 3
0.000415 0.00023
1410 88.0
Boiling Range
C F
271 - 324 520 - 615
Pour Point
C F
- 26 -15
Flash Point, Pensky-Marten (ASTM-D93 - 46) C
F
151 305
Fire Point (Pensky-Marten)
C o
F
Autoignition Temperature o C o
F
Viscosity at 0C cS
None to boiling
Over 649 Over 1.200
130
DSW 433942
STLCOPCB4087048
Santotherm FR-0 Kinematic Viscosity
VISCOSITY CS
OSVJ
STLCOPCB4087049
OS\N 433944
j
STLCOPCB4087050
? .V*
Santotherm FR-0 Vapour Pressure
100 C
300 DSW 433945
350
STLCOPCB4087051
31.
FIRE RESISTANT FLUID - SANTOTHERM FR-O
System Design Hints ( see Page ... 39.. )
Fluid Maintenance
( see Page . . .4Q . )
Safe Handling
( see Page .. AX . )
DSVV 433946
STLCOPCB4087052
FIRE RESISTANT FLUID - SANTOTHERM FR-1
32.
MAXIMUM BULK TEMPERATURE
315C 600F
RECOMMENDED MAXIMUM FILM TEMPERATURE 340C 644F
Santotherm FR-1 is a general purpose fire-resistant fluid. It is being used in Europe and the U. S. A. for the following applications :
Copper concentration Mould heating Resin reactors Bitumen coating Plywood presses Calendering rolls Rotational moulding Thin film processors Glycol dehydration
Solvent recovery Wax coating Space heating Asphalt heating Drying ovens Maleic anhydrid production Oil additive production Rubber chemicals production
DSW 433947 STLCOPCB4087053
FIRE RESISTANT FLUID - SANTOTHERM FR-1 TYPICAL PHYSICAL, CHEMICAL AND THERMAL PROPERTIES
Composition Appearance
Chlorinated, aromatic hydrocarbons
liquids
Odour
characteristic
Coefficient of Expansion C F
0.00056 0.00031
! . nsity at 25 C (77F) kg/m3
Ib/ft 3
1385 85.5
Boiling Range
C F
Pour Point
C F
327 - 360 620 - 680
-19 2.2
Flash Point, Pensky-Marten (ASTM-D93 - 46) C
F
177 350
Fire Point (Pensky-Marten)
C o
F
Autoignition Te mperature o C o
F
None to boiling
652 1.206
Viscosity at 0C cS
2.500
3?
9
&
STLCOPCB4087054
it
34 FIRE RESISTANT FLUID - SANTOTHERM FR-1
1
DSW 433949 STLCOPCB4087055
KG/M'
KCAL/KG C --
Santotherm FR-1 Variation of properties with temperature
STLCOPCB4087056
KCAL/M. HR. C --*
Santotherm FR-1 Kinematic Viscosity
VISCOSITY CS
DSW 433951
STLCOPCB4087057
DSW 433952 STLCOPCB4087058
35.
FIRE RESISTANT FLUID - SANTOTHERM FR-1
Systems Design Hints ( see Page . .39 .. )
Fluid Maintenance
( see Page . 49... )
Safe Handling
( see Page .41... )
DSW 433953 STLCOPCB4087059
36.
FIRE RESISTANT FLUID - SANTOTHERM FR-2
MAXIMUM BULK TEMPERATURE
315C 600F
RECOMMENDED MAXIMUM FILM TEMPERATURE 340C 644F
This fluid is suitable for continuous processing operation without shut downs. It has the benefit of a lower vapour pressure at the maximum operating temperature.
DSW 433954 STLCOPCB4087060
37
FIRE RESISTANT FLUID - SANTOTHERM FR-2 TYPICAL PHYSICAL, CHEMICAL AND THERMAL PROPERTIES
Composition
Appearance Odour
Coefficient of Expansion per C per F
Density at 25C (77C)
kg/m3 lb/ft 3
Distillation Range
C F
Pour Point
cC F
Viscosity at 0C
cS
Flash Point, Pensky-Marten
Closed cup
C
ASTM-D93 - 46
F
Fire Point, Pensky-Marten
Closed cup
C
ASTM-D93 - 46
F
Auto-ignition Temperature C F
Chlorinated aromatic hydrocarbons
Pale yellow liquid
Characteristic
0.00052 0.00029
1,450 90.5
343-375 650-707
-7 19.4
10,000
196 3 85
None to boiling
-
672 1243
OS>N STLCOPCB4087061
FIRE RESISTANT FLUID - SANTOTHERM FR-2 VARIATION OF PROPERTIES WITH TEMPERATURE
Tempe rature
Density
Specific Heat
Thermal Conductivity
Viscosity
Vapour Pressure
F c lb/ft3 Kg/m3 BTU/lb. Kcal/Kg. BTU/ft. hr. Kcal/m. hr. lb/hr. ft F "C "F c
cP
cS mmHg Kg/cm3 absolute
50 10 100 38 150 66 200 93 250 121 300 149 350 177 400 204 450 232 500 260 550 288 600 316 650 343 700 371
91.4 1464. 6 89. 8 1437.6 87. 8 1407. 7 86. 2 1380. 7 84. 5 1352.9 82. 7 1325.2 81. 0 1297. 4 79. 3 1269.6 77. 5 1242. 0 75. 8 1214. 2 74. 1 1186. 4 72. 3 1158. 7 70. 6 1130.9 68.9 1103. 1
0. 257 0.265 0.274 0. 2840 0. 2922 0. 3003 0. 3084 0.3166 0. 3247 0. 3328 0. 3410 0. 3 491 0. 35 73 0. 3654
0.257 0. 265 0.274 0. 2840 0.2922 0. 3003 0. 3084 0. 3166 0. 3247 0. 3328 0. 3410 0. 3491 0. 3573 0. 3654
0. 05881 0. 05852 0. 05801 0. 05788 0. 05748 0. 05703 0. 05655 0. 05603 0. 05548 0. 05488 0. 05424 0. 05357 0. 05286 0. 05211
0. 0875 0. 0871 0. 0863 0. 0861 0.0855 0. 0849 0. 0842 0. 0834 0. 0826 0. 0817 0. 0807 0. 0797 0. 0787 0. 0775
7090. 6 151. 01 27. 83 11.971 6.949 4.531 3. 201 2.399 1. 881 1.529 I. 2795 1.0971 0.9596 0. 8535
2928 62. 4 11.5 4.9 2.9 1.9 1. 3 1. 0 0. 8 0. 6 0. 5 0.5 0. 4 0. 4
1999 43.4 8.2 3. 6 2. 1 1.4 1.0 0. 8 0.6 0. 5 0.4 0. 4 0.4 0.4
-6 15 37 84 173 340 615 20.3 psia
'-' 0. 0082 0. 0204 0. 0503 0. 1142 0. 2553 0. 4624 0. 8364 1. 4273
DSW 433956 STLCOPCB4087062
W/9M
-- OoOa/IVOX
Santotherm FR-2 Variation of properties with temperature
DSW 433957 STLCOPCB4087063
- -- OoUH'WnVOM
IfTiTTBT STLCOPCB4087064
- ** */ * ki- L\ if - 11
Santotherm FR-2 Vapour Pressure
Y. . \V'.
VAPOUR PRESSURE KG/CM1
0.04 0.001
200 250 300 350 C DSW 433959
STLCOPCB4087065
39.
FIRE RESISTANT FLUID - SANTOTHERM FR - SERIES
System Design Hints A good system design allows for the rapid removal of low boiling materials and moisture from the system.
Moisture is automatically removed if the expansion tank and vent pipe are kept at over 100C and we suggest that the expansion tank is kept at 105/110C. This is most easily done by taking a bore line from the heater outlet direct to the expansion tank.
In the case of systems operating intermittently this small bore line will in some cases be insufficient to bring the expansion tank up to temperature rapidly and we recommend circulating the bulk of the fluid through the expansion tank at start-up. Santotherm FR fluids are oxidation-resistant and an inert gas blanket is not required - in fact it would interfere with the continuous venting of the system described above. The vent pipe from the expansion tank should be of generous diameter and be taken outside the building; it should preferably be lined with a corrosion-resistant material e.g. teflon as the combination of moisture and the low boiling degradation products of Santotherm FR fluids are corrosive at ambient temperatures.
Lagging of the vent pipe is recommended as is the fitting of a device to prevent direct ingress of water.
A vapour separator should not be necessary as the procedures outlined above allows for venting of the system.
DSW 433960
STLCOPCB4087066
40.
FIRE RESISTANT FLUID - SANTOTHERM FR - SERIES Fluid Maintenance The fluid should be analysed within 24 hours of start up and every 3 months for the first year of operation. Afterwards, sampling once every 6 months is generally sufficient. Analytical procedures are available from Monsanto who will also comment and advise in any corrective action required.
DSW 433961 STLCOPCB4087067
FIRE RESISTANT FLUIDS - SANTOTHERM FR-SERIES
41
Safe Handling
On the basis of animal toxicity studies, Santotherm FR fluids may be considered only slightly toxic from the standpoint of accidental massive skin exposure or accidental ingestion. Similarly, single exposures to high concentration of vapours ( when heated sufficiently to volatilize ) or high concentrations of decomposition products ( if the fluid is accidentally discharged into the fire chamber ) are not serious hazards because the irritating character of such vapour concentrations precludes voluntary exposure. Repeated or prolonged skin exposure should be avoided since Santotherm FR fluids act as a solvent for fats and oils of the skin. Removal of these natural, protective barriers can lead to drying and chapping such as occurs with exposure to paint thinners. More important, Santotherm FR fluids may be absorbed if allowed to remain on the unbroken skin. For these reasons, we recommend that the skin be washed with soap and water if there is contact. A skin burn resulting from accidental contact with hot fluid should be treated in the normal manner for any thermal burn due to hot oils.
Because of their low vapour pressure, there is no significant vapour inhalation hazard when Santotherm FR fluids are at room temperature. For example there is no vapour exposure problem while transferring the fluid from its shipping container to the heat transfer system. On the other hand, the vapours emitted by Santotherm FR fluids heated to elevated temperatures are injurious on prolonged exposure. It is indicated that the "threshold limit value" or atmospheric vapour concentration which cannot be safely exceeded ( on a daily basis ) is 0.5 - 1.0 milligrams of Santotherm FR vapour per cubic meter of air in the workroom. In heat transfer installations, the fluid must be
DSW 433962
1
STLCOPCB4087068
m
42.
used in a closed system free from leaks with the expansion tank vented to the outdoors. Accordingly, there should be little or no opportunity for workers to come in contact with vapours. It should also be noted that Santotherm FR fluids contain chemical compounds of extreme stability which will persist in the environment if allowed to escape. Pollution of the environment must be prevented by good system design and construction so that leakages and spillages are minimised and any that occur are contained and collected. Salvaged Santotherm FR fluids should be returned to Monsanto for redamation or disposal. Do not dispose of waste Santotherm FR into drains or sewers
DSW 433963
STLCOPCB4087069
Section 3
DSW 433964 STLCOPCB4087070
...
43
SPECIAL PURPOSE FLUIDS Santotherm 77 Santotherm 130 Santotherm 190
DSW 433965
STLCOPCB4087071
44.
SPECIAL PURPOSE FLUID - SANTOTHERM 77
MAXIMUM BULK TEMPERATURE
370C 700F
RECOMMENDED MAXIMUM FILM TEMPERATURE 410C 770F
Santotherm 77 has been used for several years in commercial scale and pilot plant systems in a diversity of applications: e.g. paint and resin manufacture, high-temperature plastic extrusion, lamination of plastics, chemical processing, laboratory baths and thermostatic devices.
DSW 433966
STLCOPCB4087072
SPECIAL PURPOSE FLUID - SANTOTHERM 77 TYPICAL PHYSICAL, CHEMICAL AND THERMAL PROPERTIES
Composition
Aromatic Ether
Appearance
Oily liquid
Odour
faintly phenolic
Coefficient of Expansion C F
0.00061 0.00034
Density at 25 C (77F) kg/m3
lb/ft 3
Boiling Range
C F
Pour Point
C F
1165 72.7
Approx. 443 Approx. 830
7 45
Flash Point, Pensky-Marten (ASTM-D93 - 46) C
F
238 460
Fire Point (Pensky-Marten)
C 0
F
Autoignition Te mperature o C 0 F
282 540
318 605
Viscosity at 0C cS
-
DSW 433967
STLCOPCB4087073
oSvN *>88
STLCOPCB4087074
Santotherm 77 Kinematic Viscosity
VISCOSITY CS
i
DSW 433969
j
j
i
i
,1
STLCOPCB4087075
y~
t'h'Mi ,\*4 -.rAW.' .
Santotherm 77 Vapour Pressure
VAPOUR PRESSURE KG/CM*
0.001
0.0001 101
DSW 433970
STLCOPCB4087076
"Nf'
H 1147. J<
SPECIAL PURPOSE FLUID - SANTOTHERM 77 System Design Hints Aluminium should not be used as a material of construction inside the system. Copper too is best kept to a minimum especially when operating over 370C (700F). Fluid Maintenance ( see Page . .57 . . ) Safe of Handling ( see Page . .58. . )
DSW 433971
STLCOPCB4087077
48
SPECIAL PURPOSE FLUID - SANTOTHERM 130
MAXIMUM BULK TEMPERATURE
150C 302F
RECOMMENDED MAXIMUM FILM TEMPERATURE 170C 338F
Santotherm 130 was special developed for use at very low temperatures.
DSW 433972
STLCOPCB4087078
SPECIAL PURPOSE FLUID - SANTOTHERM130 TYPICAL PHYSICAL, CHEMICAL AND THERMAL PROPERTIES
Composition Appearance
Organic Silicate
Oily liquid
Odour
characteristic
Coefficient of Expansion C F
0.0011 0.00063
Density at 25 C (77F) kg/m^
lb/ft 6
Boiling Range
C F
Pour Point
C F
870 54.3
216 - 349 420 - 660
less than -73 less than -100
Flash Point, Pensky-Marten (ASTM-D93 - 46) C
F
77 170
Fire Point (Pensky-Marten)
C o
F
Autoignition Te mperature o C o
F
82 180
-
Viscosity at 0C cS
J
DSW 433973
STLCOPCB4087079
SPECIAL PURPOSE FLUID - SANTOTHERM 130
50
VARIATION OF PROPERTIES WITH TEMPERATURE
Tempe rature
Density
Specific Heat
Thermal Conductivity
Viscosity
Vapour Pressure
F "C lb/ft 3 Kg/m3 BTU/lb. Kcal/Kg. BTU/ft. hr.
F c
"F
-100 -73 - 50 -46
0 -18 50 10 100 38 150 66 200 93 250 121 300 149 350 177 400 204
60. 4 58. 8 57.2 55. 7 54.1 52.5 50.9 49.4 47.8 46.2 44. 5
967. 6 941.9 916. 3 891.5 866. 7 841. 0 816. 0 790. 6 765. 8 739.3 716. 0
0. 450 0. 455 0. 460 0.465 0. 470 0.490 0. 520 0.535 0. 610 0.`625 0. 730
0. 450 0. 455 0. 460 0. 465 0. 470 0. 490 0.520 0.535 0.610 0. 625 0. 730
0. 0747 0.0724 0. 0701 0. 0680 0.0659 0. 0640 0.0621 0. 0604 0.0587 0. 0572 0. 055 7
Kcal/m. hr. lb/hr. ft
c
cP
cS mmHg Kg/cm2 absolute
0. 1112 0. 1077 0.1042 0. 1011 0. 0981 0. 0952 0. 0924 0. 0899 0. 0873 0. 0851 0. 0829
280.9 36 11. 10 5.30 3.24 2. 18 1. 62 1.21 0.99 0.97 0. 70
116 120 15 16 4. 6 5. 01 2.2 2. 50 1.3 1.55 0.9 1. 10 0. 7 0. 82 0.5 0. bl 0.4 0. 54 0. 4 0.50 0. 3 0. 40
0.6 3 12 33 100 250 550
- 0. 0008 0. 0041 0. 0163 0. 0449 0. 1360 0. 3400 0. 7480
! i
i
DSW 433974
STLCOPCB4087080
Santotherm 130 Variation of properties with temperature
KG/M'
KCAL/KG C --
KCAL/M. HR. C --
0.080
I
DSW 433975
STLCOPCB4087081
I
DSW 433976
STLCOPCB4087082
VAPOUR PRESSURE KG/CM2
STLCOPCB4087083
51.
SPECIAL PURPOSE FLUID - SANTOTHERM 130
System Design Hints
Santotherm 130 is suspectible to oxidation and moisture. It is suggested that the system be filled under vacuum though a paper or earth filter so as to remove any traces of moisture arising out of drum handling.
An inert gas blanket will have to be used on the expansion tank. Chlorinated solvents should not be used for plant cleaning. Aluminium should not be used as a material of construction.
Fluid Maintenance
( see Page ...57. )
Safe Handling
( see Page .. .58 . )
'
|
|
i
DSW 433978
i
STLCOPCB4087084
52.
SPECIAL PURPOSE FLUID - SANTOTHERM 190
MAXIMUM BULK TEMPERATURE
355C 670F
RECOMMENDED MAXIMUM FILM TEMPERATURE 385C 725F
Santotherm 190 was the first high temperature heat transfer fluid manufactured by Monsanto.
Since its introduction it has proved itself in numerous chemical processes, which require high temperatures and accurate heat control.
DSW 433979
STLCOPCB4087085
SPECIAL PURPOSE FLUID - SANTOTHERM 190 TYPICAL PHYSICAL, CHEMICAL AND THERMAL PROPERTIES
Composition Appearance
Organic Silicate
Oily liquid
Odour
characteristic
Coefficient of Expansion C F
nsity at 25 C (77F) kg/m3
lb/ft 3 !
Boiling Range
C F
Pour Point .
C F
0.00068 0.00038
1.190 74.2
427 800
-29 -20
Flash Point, Pensky-Marten (ASTM-D93 - 46) C
F
238 460
Fire Point (Pensky-Marten)
C 0
F
Autoignition Te mperature o C o
F
285 545
593 1.100
Viscosity at 0C cS
STLCOPCB4087086
Santotherm 190 Variation of properties with temperature
1200-
11001000-
KG/M*
KCAL/KG C --
KCAL/M. HR. C --
0.6000.500 ` 0.400-
0.1180.115-
0.110-
0.1050.104 eiils
DSW 433981
STLCOPCB4087087
Santotherm 190 Kinematic Viscosity
l
VISCOSITY CS
DSW 433982
STLCOPCB4087088
VAPOUR PRESSURE KG/CM2- *
DSW 433983
STLCOPCB4087089
SPECIAL PURPOSE FLUID - SANTOTHERM 190 VARIATION OF PROPERTIES WITH TEMPERATURE
54.
Temperature
Density
Specific Heat
Thermal Conductivity
F "C lb/ft 3 Kg/m^ BTU/lb. Kcal/Kg. BTU/ft. hr.
F c
F
Kcal/m. hr.
c
'50 10 100 38 150 66 200 93 25 0 121 300 149 350 177 400 204 45 0 232 500 260 550 288 600 316 650 343 700 371
76. 4 74. 4 73. 0 71. 7 70. 2 68. 7 67. 3 65. 9 64. 5 63. 1 61. 7 60. 2 58. 8 57. 4
1223.9 1191.9 1170.2 1148. 6 1124. 6 1100. 6 1078. 1 1055. 7 1033.3 1010.9
987. 6 964. 4 942. 0 919. 6
0. 39 0. 41 0. 42 0. 43 0. 44 0. 46 0. 47 0. 48 0. 49 0. 51 0. 52 0.54 0. 55 0. 56
0. 39 0. 41 0. 42 0. 43 0. 44 0. 46 0. 47 0. 48 0. 49 0. 51 0. 52 0. 54 0. 55 0. 56
0. 0793 0. 0786 0. 0775 0. 0768 0. 0764 0. 0758 0. 0750 0. 0743 0. 0736 0. 0729 000722 0. 0714 0. 0707 0. 0700
0. 1180 0. 1170 0. 1153 0. 1143 0. 1137 0. 1127 0. 1116 0. 1105 0. 1095 0. 1085 0. 1075 0. 1063 0. 1052 0. 1042
'Viscosity
Vapour Pressure
lb/hr. ft
cP
cS mmHg Kg/cm2 absolute
529.9 104. 1
38. 7 18. 87 12. 10
7. 19 6. 05 4.11 2. 90 2. 66 2. 18 1.93 1. 69 1. 45
245 43. 0 16. 0 7. 8 5. 0 3. 0 2.5 1.7 1. 2 1. 1 0.9 0. 8 0. 7 0. 6
200 36. 1 14. 0 6. 8 4. 4 2. 7 2. 3 1.6 1.2 1. 1 0.9 0. 8 0. 7 0. 7
- --
6 15 30 60 150
-' 0. 0082 0. 0204 0. 0408 0. 0816 0. 2040
DSW 433984
STLCOPCB4087090
-it
55.
SPECIAL PURPOSE FLUID - SANTOTHERM 190
System Design Hints Santotherm 190 will hydrolyse in the presence of water giving rise to products that resemble the effects of severe fluid degradation so moisture must be kept out of the system. Canned ( glandless ) pumps are the only ones recommended for use with Santotherm 190. Aluminium should not be used as a material of construction inside the system and the use of copper should be kept to a minimum. The expansion tank should be sized to accomodate 70% of the entire system. An efficient vapour separator is essential ( as illustrated ) on all Santotherm 190 systems to remove low boilers formed during the long service life of the fluid. The separator should be installed at the highest point of the ring main on the fluid return side. To produce a lower pressure in the expansion tank to promote any "low boilers" vapour readily flashing off, the tank should be at least 6 feet (1.8 meters ) above the level of the return main. It should be insulated to prevent moisture condensation. Part of the liquid from the vapour separator will by-pass the ring main and flow through the expansion tank, entraining vapours from the main. The condensing vessel should not be lagged, since this will produce a difference of operating temperature between the expansion tank and the condenser and the vapour pressures of the low-boilers will be different in each vessel. This will result in released vapours from the fluid in the expansion tank migrating to the condensation vessel where they will condense. Rating of the separator should be based on a phenol formation rate of 1 part of phenol by volume per hour per 1000 parts by volume of Santotherm 190 in the system.
DSW 433985
STLCOPCB4087091
SANTOTHERM 190 SYSTEMS EXPANSION TANK, VAPOUR SEPARATOR AND CONDENSER
56
DSW 433986
STLCOPCB4087092
57
SPECIAL PURPOSE FLUIDS - SANTOTHERM 77, 130, 190 Fluid Maintenance (77 and 130) Samples of fluid should be taken from the system 24 hours after start-up and every 3 months for the first year of operation. Afterwards, sampling at 6-monthly intervals is generally suf ficient. Analytical procedures are available from Monsanto who will comment on results and advise on any corrective action required. Fluid Maintenance (190) The viscosity of the fluid stripped of low boilers is measured according to a procedure available from Monsanto. Should the stripped viscosity need reducing in order to improve heat transfer properties, Santotherm 1000 (a solid with a m. p. of 50C) can be added to the system.
DSW 433987
STLCOPCB4087093
SPECIAL PURPOSE FLUIDS - SANTOTHERM 77, 130, 190, 1000
Safe Handling
Santotherm 77, 190 as liquids, are of low toxicity but through hydrolysis with water and as a result of thermal decomposition, phenol is produced and the handling precautions of used fluid should, therefore, be the same as those for phenol.
Should these Santotherm fluids come in contact with the skin, the affected parts should immediately be washed with water or soap and water. If reddening or soreness of the skin develops, a lanolin based cream should be applied. No ointments should be used on severe burns which must be covered with a dry dressing. Operators handling the liquid should wear anti-splash goggles or face visors; if the liquid accidentally enters the eye, it should be copiously washed with water for at least 15 minutes. In a factory with adequate ventilation the vapour should not present a problem and no immediate or chronic effects have been noted among the workers in the plants that manufacture these fluids.
Safe Handling of Santotherm 130
Santotherm 130 as a liquid is of low toxicity. There is a tendency for it to dry the skin on long contacts but otherwise no special handling precautions are necessary.
Safe Handling of Santotherm 1000
Care must be taken when adding solid Santotherm 1000 (m. p. 50C) to'hot Santotherm 190 (at 100-200C) through the expansion tank. Operators should be provided with protective clothing and the addition process should be carried out under well ventilated conditions.
DSW 433988
STLCOPCB4087094
59.
1. GENERAL
DESIGN HINTS FOR SANTOTHERM SYSTEMS
TYPES OF HEATER
The heater is the most critical component in a Santotherm system. Accordingly, on the basis of the prop erties of the fluid selected for its operating range -- the heater should be specified with great care. '
The type and size of heater is governed by the heat demand of the user-system considered in balance with the maximum recommended bulk temperature of the Santotherm fluid selected, and the fluid film tempera ture at a practical flow velocity over the heat donor surfaces.
Two basic heater designs for Santotherm fluids are available: the liquid tube and fire tube type. In liquid tube heaters, the fluid is pumped through the tubes at a definite flow rate as it is heated; in fire tube types, the fluid flows through the shell of the heater that surrounds the fire tubes.
In systems where operating temperatures of 500 "F (260 "C) or higher are required, a liquid tube type heater is preferred... unless a specific design is devised to force a steady flow of the fluid over the heat donor surface.
The fuel for Santotherm heaters is purely optional. Gas, oil-fired heaters, and electrical heating elements are all used with success. Coal fired heaters are gene rally not recommended because of their slow response to changes of load.
The overall thermal efficiency of a fired heater will generally be comparable to steam boilers of similar size. Efficiencies of 75-80 % can be expected when convection sections are added. Efficiencies of 60-70% are achieved with only a radiant section.
CIRCULATION OF HEAT TRANSFER COEFFICIENTS & PRESSURE DROP DATA
Santotherm systems are outstanding for serving multiple-users at different temperature levels. When designing a Santotherm liquid heat transfer system, it is important to remember that the FLUID AND ITS SERVICE LIFE CAN BE NO BETTER THAN THE ENGINEERING OF THE SYSTEM.
Santotherm heat transfer fluids are ideally suited for systems requiring high temperature precision heating, precise temperature control, minimum capital ex pense, low maintenance, and a high degree of safety. The systems, however, must be properly designed and constructed. While there is nothing profoundly differ ent or greatly complicated about Santotherm liquid
heat transfer -- certain design parameters must be rigidly observed if the system is to give trouble-free service, run efficiently, and to return the full benefits of heat delivered by unpressurized liquid.
A summary of these parameters is : the heater and the fluid flux, the moisture-tightness of the system, and the fail-safe control devices provided. When these factors of design are properly observed, normal main tenance and simple operating procedures will assure years of reliable, trouble-free operation.
FILM TEMPERATURES
Since heating is not uniform in fired heaters, the maximum heat stress conditions must be used to determine what will be the film temperatures encoun tered.
Example:
The film coefficient for the fluid in a given heater is 250 BTU/hr.sq.ft., F, and the bulk fluid temperature is 570 F. The average radiant absorption rate is 9,000 BTU/sq.ft., hr. The maximum radiant absorp tion rate is 17,000 BTU/sq.ft., hr.
Thus, the average film temperature is :
570" + 9,000 = 606 "F 250
but the maximum film temperature is :
17,000
570" +
= 638 "F
250
Past experience shows that when purchasing a heater, the buyer should insist that the design and the capacity provide an optimum film temperature for the fluid to be used.
For radiant heaters, the method of Lobo and Evans* is useful in calculating the film temperatures.
When electric heaters are used -- the heat flux is more uniform. However, it is important to remember that all of the heat from the heating element passes into the fluid. Therefore, the watt-density on the surface of the heater tube and the fluid velocity
DSW 433989
STLCOPCB4087095
; r-.
60.
across the heat-donor surface should be in proper balance to avoid excessively high film temperature. Watt-densities in the range of 8 to 10 watts per square inch (1.25 to 1.5 watts per sq.cm.) with a minimum velocity of 4 feet per second (1-1/3 meter per second) are suggested. However, higher wattdensities in the range of 18 to 22 watts per square inch (3.0 to 3.5 watts per square centimetre) have proved satisfactory in properly-designed installations with fast flow. * Lobo, W.E. and Evans, J.E., Trans, AlCHE 35,743 (1939).
FLUID VELOCITIES
Fluid velocities over the heat donor surfaces should be relatively high; generally 4 to 10 feet per second (1-1/3 to 3 meters per second). This helps avoid both excessive film temperatures and also reduces the quantity of fluid present in the film that is in direct contact with the high temperature heat-donor surface. The illustration shows the effect of fluid velocity on film temperature and indicates the importance of this design requirement.
EFFECT OF LIQUID VELOCITY ON FILM TEMPERATURE DURING HEATING
ACCURATE DETERMINATION OF HEAT TRANSFER COEFFIDIENT
To determine overall heat transfer coefficients for the heating system, individual coefficients have to be calculated for heat donor side and the fluid service side at each user station. Film heat transfer coeffi cients for Santotherm liquids are best calculated with the Dittus-Boelter* equation, using the data from the fluids' physical property charts. The Dittus-Boetler equation is:
* = 0.3 when Santotherm is used for providing heat x = 0.4 when Santotherm is used for removing heat DG Reynolds Number (dimensionless)
P Cp. p = Prandtl Number (dimensionless)
k hD
= Nusselt Number (dimensionless) k The units to be used to maintain the dimensionless qualities of the numbers, h = Santotherm film heat transfer coefficient D = Internal pipe diameter k = Thermal conductivity of Santotherm at
temperature t G = Mass velocity of Santotherm Cp = Specific heat of Santotherm at temperature t p. = Absolute viscosity of Santotherm at
temperature t
* The Dittus-Boelter equation is only applicable for truly turbulent flow conditions when the Reynolds Number ex ceeds 10,000. (Dittus-Boelter: University .of California Pu blications in Engineering 1930.2, 13, pp. 443-461). Morris and Whitman (Morris and Whitman, Ind. Engineering. Chem. 1928, 20 234) have devised a modified calculation which is necessary for determining coefficients under laminar flow conditions.
DSW 433990 >
STLCOPCB4087096
Pumps
Pumps must have sufficient capacity and pressure head to circulate the fluid at the rate required by the particular installation. For large flow rates, the pump should generally be the centrifugal type; any one of a number of the standard brands of high temperature pumps is suitable. For most systems, cast steel pumps are best. Pump manufacturers usually specify that above 450F fluid temperatures ( 230Q, a water jacketed, deep stuffing box or mechanical seal and water-cooled bearings should be used. Mechanical seals are used widely today. On pumps with a stuffing box, at least five rings of packings should be provided, with graphite-impregnated metal foil around an asbestos core at each end and in the centre, and semi-plastic asbestos compound impregnated with graphite on either side. An open, non-overloading impeller is desirable to handle the cool, relatively viscous liquid at start-up.
When a new system is first put into operation, a slight leakage may be noticed at the pump packing. The pump gland should not be tightened however, until the system has heated up to close to the temperature of operation. Canned ( glandless ) pumps require no seal and have proved very serviceable in Santotherm systems.
Regardless of the type of pump selected, the flow rate should be checked regularly against the pump's performance when new. To avoid shaft trouble and seal leakage, it is important to avoid pipe support stresses on the body of the pump. Each pump should be fitted with a control device to switch off the burner in case of pump failure.
61.
If expansion loops are used in the pump section piping, they should be horizontal or vertically downward. Loops should not be vertically upwards, because this forms a trap which can collect air and vapour which seriously hamper the pump performance.
DSW 433991
STLCOPCB4087097
62.
Filters In a new system , install a wire mesh strainer in the pump section.
When operating where solids and contamimants might enter the system, is is advisable to permanently install a high temperature filter by-pass line that can be isolated with valves for periodic cleaning.
Materials of Construction The majority of metals show good corrosion resistance to Santotherm fluids. Mild steel is generally used but see under each fluid for materials to be avoided.
The Expansion Tank and venting arrangements The expansion tank should be installed at the highest point in the system on the suction side of the pumps and it should serve as the main venting point of the system.
The vent line from the tank should be led outside of the building so that any hot vapours do not enter the working area.
When using a nitrogen blanket moisture should be driven off from the fluid before the gas pressure is set. The expansion tank should be sized so that it is 1/4 full when the system is at room temperature and 3/4 full when the system is at operating temperature. It should be fitted with a sight glass at the full range and with a float operated, minimum level switch to shut off the heater in the event of accidental fluid loss.
DSW 433992
STLCOPCB4087098
63.
Pipework
The most important factors in the piping layout for Santotherm systems are : (A) Proper sizing for the required flow rate and (B) minimizing pressure drop. Because the system will undergo temperature changes, adequate loops to relieve expansion and contraction stress are essential. Hot forge seamless pipework should be used throughout the system. It is characteristic of most organic fluids (including Santotherm) to have a tendency to leak through joints and fittings at high temperatures unless these fittings are very tight. Therfore flanged joints should be used sparingly to minimize potential leak points. Threaded connections are used with Santotherm up to a 1-inch ( cm) maximum size. A new die is recommended in cutting the threads to ensure a proper fit. Careful attention to threading procedure should provide a good connection; do not rely on the use of pipe dope to eliminate leakage. The connections must be steel and the thread cut taper to taper.
Below 450F (230C), P. T. F.E. tape can be used for sealing threaded connections. Above 450F (230C)t powdered graphite mixed with S. A. E. 30 oil to a consistency of thick oil paint has been used successfully. The graphite mixture is not suitable for lower temperatures, since the higher temperature is needed for baking. In large size pipes, connections should be welded wherever practical. Careful layout and use of curved sections can minimize the number of welded or flanged connections required. When a flanged connection is made, ASA 150 or equivalent raised-face flanges are recommended. The flanges should be back welded to the pipe and proper gasketing used, such as spiral wound asbestos and stainless steel gasket. Small lip spiral wound gaskets are to be preferred over the wide lip type, because they allow better compression with the ASA 150 flange. Short cut, pre-cut and cured asbestos gaskets have also proved satisfactory. It is recommended that strefch-resisting high-temperature alloy stud bolts, be used. All high points in the pipework should be provided with vent valve connections.
DSW 433993
P! j
STLCOPCB4087099
y A`t -
. tt.
64.
Valves
Cast steel valves equivalent to ASA 150 with deep stuffing boxes are satisfactory for Santotherm systems. If it is possible, globe valves with an outside screw ( as a protection against high temperatures ) should be used throughout the system since they provide the only truly effective seal against Santotherm fluids. Gate valves do not always provide a tight shut-off. Gland rings should be of asbestos yarn reinforced with wire encasing an asbestos core impregnated with graphite; as many rings as possible should be used.
Controls
Controls for heating systems using Santotherm should be installed both on the heater itself and on the heat-using units. A wide variety of thermal-operating controls are available, and any reliable standard equipment is satisfactory.
Install heater controls to regulate the firing mechanism in direct proportion to the required output. These controls should increase or decrease the heat in-put to maintain the Santotherm at the operating temperature required by the heat-demand of the user. Small units may be operated satisfactorily by relatively simple "on-off" or "high-low" controllers; larger units will operate more uniformly if equipped with modulating temperature controls.
Install user controls to regulate the flow of the heat transfer fluid in proportion to the heat-consumption of the heat-using equipment. In a multiple-user system, separate controls should be installed on each consuming unit, to assure the proper heat-delivery.
DSW 433994
STLCOPCB4087100
65.
Safety Controls In addition to activating controls, the system must also be fitted with the proper safety devices to meet the local code requirements. Safety controls should include : (A) High temperature cutoff at the heater outlet ... to shut off the
burner in the event of an excessive temperature rise. (B) Heater low flow cutoff ... to shut down the burner, should flow
rate drop below design rates, or if a loss of flow occurs due to pump malfunction or failure. Burners should be equipped with regular automatic ignition controls and flame failure controls. In wide-range firing, an over-fire draft control will save heat losses. Electric power failure and instrument air failure safety controls are also desirable. In general, a policy of "fail-safe" instrumentation and control in the designing is essential, using good quality indicating - and recording gauges, with accuratereading scales calibrated for the particular limits of operation. (C) Expansion tank low level switch ... to shut off the heater in the event of accidental fluid loss.
DSW 433995
STLCOPCB4087101
2. TYPICAL SYSTEM LAYOUTS
66.
The transfer of process heat as a liquid offers these benefits to the installation: Precise heating levels Closer temperature control at each user station Minimum cost installations Greater operating safety Low maintenance costs
Santotherm systems are characterized by their extreme flexibility. A single heater can serve multiple users operating at the same or different temper ature levels. The systems can be devised to deliver and to remove heat. Since the heat transfer is done with a liquid, there are no problems of condensation, pressure drop, and great heat surges.
The following diagrams illustrate the basic features of the heater off-take connections and the various arrangements of heat users that can be operated on Santotherm fluids.
THE HEATING PLANT
i
This diagram illustrates a typical basic heating plant for a SANTOTHERM FR system. Note the use of instruments to control the fluid temperature leaving the heater and the by-pass flow control to assure adequate flow through the heater regardless of c user demands.
DSW 433996
STLCOPCB4087102
HEATING A SINGLE USER:
!
67
/
f
WITH LOW LIMIT CUTOFF TO BURNER
Note that the user temperature can be controlled by either (a) rate of flow of SANTOTHERM to the user, or (b) by the temperature of SANTOTHERM, varied by fuel input to the heater.
HEATING MULTIPLE USERS:
FIG. 3
PUMP
FRC=FLOW RECORDER CONTROLLER WITH LOW LIMIT CUTOFF TO BURNER
Note that each user can be controlled at a different temperature by control of the flow of SANTO THERM and therefore the rate of flow of heat offered.
DSW 433997
STLCOPCB4087103
HEATING OR COOLING SEVERAL USERS SIMULTANEOUSLY
68.
I '
PUMP
Note that with this arrangement, a Santotherm system can be used to cool a batch process rapidly after reaction. The heat taken out can be used as a source of hot water taken off from the heat exchanger. The cooling process is achieved simply by by-passing the users and cutting in a cooling circuit in which the fluid passes through a heat exchanger.
DSW 433998
STLCOPCB4087104
TEMPERATURE CONTROL BY BLENDING
69.
FLOW RECORDER CONTROLLER WITH LOW LIMIT CUTOFF TO BURNER
A single heater supplying hot fluid in this arrange ment can provide widely differing temperature levels to multiple users. The high heat circuit is connected into the low heat circuit through a 4-way valve that blends the hot and cool fluid. This type of system finds application for processing heat-sensitive mate rials.
DSW 433999
STLCOPCB4087105
4. '4
70.
SUGGESTED START-UP PROCEDURE FOR NEW SYSTEMS For a new system or one that returns to service after draining, the following check points are recommended as guides. They are supplemental to the heater manufacturers' and the heat-user processing equipment makers' recommendations apply generally to the care of the fluid in all sizes and types of systems: (1.) Check Safety and Control Devices ... for proper installation and functioning, making sure that the range settings are proper for the operation. Manually activate the instruments and apply all tests necessary to assure proper functioning. For protection of the system and for the expected long service life of the fluid it is vitally important that all instruments and controls function properly.
(2.) Check for leakage
(3.) Remove moisture from the system, using dry compressed air.
(4.) Fill the System with -Santotherm
A. Fill the expansion tank with Santotherm, and introduce the fluid slowly into the system through the expansion tank valve until the tank is almost empty. Close the valve and again fill the tank. Open the valve allowing the fluid to enter the system and repeat until it no longer flows by gravity.
B. Open all valves then start the main circulating pump in accordance with the manufacturer's recommendations. Observe the liquid level in the expansion tank, refilling as necessary until the system has been filled. Allow for the thermal expansion of Santotherm in determining the cold charge level. The expansion tank should be adjusted to 70-75 % full when the hot operating temperature is reached.
DSW 434000
STLCOPCB4087106
71.
ri;
C. Circulate the Santotherm fluid through the system for about 3 to 4 hours to eliminate air pockets and to assure complete fill of the system.
BEFORE FIRING HEATER, BE SURE THAT SANTOTHERM IS CIRCULATING FREELY.
(5) Start the Heater
A. Bring the system up to temperature slowly - about 100F per hour. This will prevent thermal shock to heater tubes, tube/heater joints, refractory materials, etc. ... and allow operators to check the functioning of instruments and controls. The slow heat-up will also allow any moisture trapped in the system to escape as a vapour.
B. Bring System to operating temperature and put the "users" on the line.
C. The fluid is generally analysed within 24 hours of plant start-up and every 3 months during the first year of operation. (See details under the fluid in question).
D. Check the filter. As foreign material collects, the filter should be periodically removed and cleaned. After several days of operation with no foreign material on the screen - it may be permanently removed. The system should be heated and cooled for at least two cycles with the screen in place since the resulting expansion and contraction will loosen mill scale.
> DSW 434001 > > }
STLCOPCB4087107
72
SUGGESTED OPERATING INSTRUCTIONS FOR LIQUID PHASE HEATING SYSTEM USING SANTOTHERM FLUIDS (1) CHECK SAFETY CONTROLS In addition to activating controls, the heater should also be fitted with the proper safety controls to meet local code requirements. (See Page 65)
DSW 434002
STLCOPCB4087108
! 73.-
(2) START-UP TEMPERATURE PRECAUTIONS
1. Temperature of fluid at start-up is important: Consult your plant or pump supplier for the minimum recommended start-up temperature. This should correspond with the maximum permitted fluid viscosity.
Failure to comply with their recommendations may lead to a burnt out motor on pumps.
2. If you have to start-up at low temperatures (below those specified ), the fluid should be heated in a safe way, for example with electric tapes etc...
3. One way of avoiding start-up temperature problems is to keep the system idling at 105C - especially in cold weather.
(3) PROCEDURE FOR START-UP ( COLD FLUID ) 1. When the start-up temperature is O.K., start the circulating
pump and check the expansion tank level to see that the Santotherm is at the proper cold-start level (1/4 full).
2. Start burner at the "low" flame setting and continue full circulation until the Santotherm bulk temperature reaches 105C.
3. Turn heater to full heat.
DSW 434003
STLCOPCB4087109
23a.
ft) PROCEDURE FOR START-UP ( HOT FLUID )
Start-up after an automatic shut-down by the safety controls (fluid should still be above 105 C)
1. Run the circulating pump for ten minutes or so to eliminate any vapour pockets formed when the fluid has remained static in the heater.
2. If there is no knocking in the system, the heater can be turned to full fire.
74,
(5^ PROCEDURE FOR SHUT-DOWN
1. Shut off burner completely with circulating pump still operating. Continue* to run the pump at full capacity for at least one hour to dissipate residual heat in the combustion chamber of the burner.
2. Shut off circulating pump after one hour and switch off all heater electrical controls.
DSW 434004
STLCOPCB4087110
75.
(6) PLANNED MAINTENANCE
Regular maintenance inspection schedules should include the manufacturers' recommendations for the heater and the components as well as inspection of the Santotherm fluid. The following is a list of inspection check points :
1. Lubrication of moving parts
2. Operating fidelity and the accuracy of the readings of safety controls and temperature limit controls.
3. Inspection of heater tubes, burner, refractory linings.
4. Periodic inspection of heater service.
5. Inspection of the water cooling at the circulating pump.
6. Re-packing of stuffing boxes ( according to the manufacturers specification ).
7. Inspection of the expansion tank venting system - vent pipe,
dessicant pot.
.
8. Half-yearly or annual sampling and analysis of the Santotherm fluid.
DSW 434005
STLCOPCB4087111
t 76.
The fluid is normally analysed with 24 hours of plant start-up and every three months during the first year of operation. Afterwards, six-monthly checks are usually sufficient. Monsanto provides analytical procedures for sample testing and will advise on corrective action required should results be outside acceptable values for used fluid.
(7) DISPOSAL OF USED FLUID Used Santotherm fluids should never be poured down normal drainage systems. Contact Monsanto for advice on safe and efficient disposal.i * * * * * * * 9
i
* > ) * DSW 434006 i 1 J ? 9
STLCOPCB4087112
77
5. UNITS CONVERSION CHART
Length Area Volume
Mass Density
Pressure Heat Heat Transfer
per unit time Heat Transfer
per unit time per unit area Heat Transfer coefficient Thermal Conductivity Viscosity Kinematic viscosity
To Convert from
cm
cm2 ft2 cm3
ft3 gallon (Imp) gallon (Imp) gallon (Imp)
kg lb
gm/cm3 lb/ft3 kg/m3
gm/cm2 lb/in2
K cal BTU
K cal/hr Kilowatt Kilowatt
K cal/m2 hr BTU/ft2 hr BTU/ft2 hr Watt/cm2 K cal/m2 hr C BTU/ft2 hr F cal/cm2 sec C K cal m/hr m2 C
Centipoise Centipoise
Centistoke Centistoke
To
ft cm .
tt2
cm2 ft3 cm3 ft3
litre gallon (US)
lb kg
lb/ft3 gm/cm3
lb/ft3 lb/in2
atmosphere
BTU K cal
Kilowatt K cal/hr BTU/hr
BTU/ft2 hr K cal/m2 hr Watt/cm2 BTU/ft2 hr BTU/ft2 hr OF K cal/m2 hr C BTU/ft2 hr of BTU ft/hr/ft2 of
lb/ft hr kg/hr m
ft2/sec ft/hr
<
Multiply by
3.28 X 10-2 30.5
1.08 X 10-3 9.29 X 102
3.53 X 10 3 2.83 X 10* 1.61 X 10-1
4.55 1.20
2.20 4.54 X 10-1
62.4 1.60 X 10-2 6.24 X 10-2
1.42 X 10-2 6.80 X 10-2
3.97 2.52 X 10-1
1.16 X 10-3 8.60 X 102 3.41 X 103
3.69 X 10-1 2.71
3.15 X 10--4 3.17 X 103
2.05 X 10-1 4.88
7.37 X 103
6.72 X 10-1
2.42 3.60
1.08 X 10-5 3.88 X 10-2
DSW 434007
I
)
STLCOPCB4087113
w
78.
The information in this manual is to our best knowledge true and accurate but all instructions, recommendations or suggestions are made without guarantee. Since the conditions of use are beyond their control, Monsanto Company and its subsidiaries disclaim any liability for loss or damage suffered from use of these data or suggestions. Furthermore no liability is accepted if use of any product in accordance with these data or suggestions infringes any patent.
DSW 434008
STLCOPCB4087114
MONSANTO EUROPEAN
OFFICES
Monsanto
Sales Offices in principal cities of Europe
HEAD OFFICE
Monsanto Europe S.A. Place Madou 1 B - 1030 Brussels, Belgium Telephone : (02)19.11.01 Telex : 22110/21986
AUSTRIA:
Monsanto (Osterreich) GmbH. Wien 1 Rudolfsplatz 12 Telephone : 63.81.70 Telex : 75601
BELGIUM /
LUXEMBURG :
Monsanto Europe N.V. Mechelsesteenweg 163 B - 2000 Antwerp, Belgium Telephone : (03) 30.58.40 Telex : 31657
FRANCE:
Societe Monsanto 9, rue d'Argenson Paris 8me Telephone : 265.65.20 Telex : 65281
GERMANY:
Monsanto Deutschland GmbH. ImmermannstraBe 3-5 4000 Dusseldorf Telephone : (0211)36.75.1 Telex : 858-1307
ITALY :
Monsanto Italians S.p.A. Via F. Filzi 24 20124 Milano Telephone : 66.62.84 - 66.63.73 Telex : 38209
NETHERLAND :
Monsanto N.V. 54, Jan van Nassaustraat 's Gravenhage Telephone : (070)24.55.78 Telex : 32208
U. K.:
Monsanto Chemicals Limited 10-18, Victoria Street London S.W.1 Telephone : ABBEY 5678 Telex : 916093
SPAIN :
Monsanto Iberica S.A. Lepanto 350 Barcelona 13 Telephone : 255.10.00 - 255.64.00 Telex : 52050
SWEDEN :
Monsanto Scandinavia AB Ulvsundavagen 108 Bromma - Stockholm Telephone : 80.28.30 Telex : 17359
DSW 434009
't
STLCOPCB4087115