Dear Colleague:
This communicatiqn is intended to alert you to recently gathered informa~ tion indicating a<I''potential health hazard for persons exposed to asbestos during the servicing of motor vehicle brake and clutch assemblies.
On July 21, 1975, the National Institite for Occupational Safety and Health convened a meeting of gove~nment and university scientists, industry representatives, and labor union officials to discuss the present state of knowledge with respect to this problem. Data was presented by investigators from the Mount Siani School of Medicine in New York City indicating that workers engaged in the maintenance and repair of automobile and truck brake linings are exposed to potentially hazardous levels o( airborne asbestos dust. Specific brake servicing operations studied included blow-out of automobile drum brake assemblies, grinding of used truck brake linings, and bevelling of new truck brake linings. Average peak asbestos air concentrations for these three activities based on personal samples taken within ten feet of the operator were, respectively, 10.5, 3.75, and 37.3 fibers (>5 microns in length) per ml. An analysis of samples of brake drum dust revealed thatalmost all of the asbestos fibers found were shorter than 0.4 microns in length.
Previous studies of the extP.nt of asbestos emissions from automobile brake lining wear showed that only a very small fraction of the original asbestos content of the brake lining is found in brake drum dust (Ref. 1-3). It was presumed that this is due to thermal degradation of the fibers during braking. The present findings indicate that enough asbestos is preserved to produce . -significant exposures during certain brake servicing procedures.
The full extent of asbestos-related disease in brake servicing personnel is not known at present because this, particular occupational group has not been studied systematically up to now. However, a review of the scientific literature on the association between asbestos exposure and mesothelial tumors of the pleura and peritoneum has revealed at least four cases of these rare tumors in persons who were-employed in jobs involving automobile brake servicing (Ref, 4-6),
i
.l
FMSI 06259
'.
... ,.
j
'
Page 2
For your information and guidance, we are enclosing pertinent references, estimates of the population at risk, a NIOSH interim recomm~ndation for
brake and clutch servicing procedures, and a copy of the Department of Labor standard covering exposure to asbestos in the work place.
The environmental studies of brake lining servicing operations outlined
above together with observations of mesothelial tumors in persons so
employed affirms the necessity for instituting and maintaining recommended
control measures in this industey so that the health hazards of asbestos .
are minimized.
nc;;.:r_' _770
J. ~~Lloy~ '
Director Office of Occupational Health
Surveillance and Biometrics
Enclosures
''
'
/ ------//,//////
' '"~.
'I
FMSI 06260
.1-
1
.. . .,.
REFERENCES
1.
Lynch, J.R.:
Brake Lining Decomposition Products.
J Ai{'r l?ollution I.
Control Aaaoc, ~8:824-26, 1968
2. Hickiah, D.E. and Knight, K.L.: Exposure to Asbestos Du~ing Brake
Maintenance. Ann Occup Hyg, 13:17-21,.1970
I ''
3. Jacko, M.G. and DuCharme, R.T.: Brake Emissions: Emission Measurements from Brake.and Clutch Linings from Selected Sources. EPA
Report 68-04-0020, 1973
4. Newhouse, M.L. and Thompson, H.: Mesothelioma of Pleura and Peritoneum Following Exposure to Asbestos in the London Area. Brit J Ind Med, 22:261-69, 1j65
5, }1cDonald, A.D. et al.: Epidemiology of Pdmary Malignant Mesothelial Tumors in Canada. Cancer, 26:914-19, 1970
6. Greenberg, M. and Lloyd Davies, T.A.: Mesothelioma Register 1967-
.1968. Brit J Ind Med, 31191-104, 1974
-
' .' FMSI 06261
~I
,.-
ESTIMATES OF THE WORKFORCE POTENTIALLY EXPOSED TO ASBESTOS IN THE MANUFACTURING AND SERVICING OF BRAKE LININGS AND CLUTCHES
' 'II',. ; I II,.
.... ~_t
Auto Mechanics
833,535
Garage Workers
Manufacture (original and rebuilding)
67,679
I
6,657
I
"'
TOTAL
907,871
SOURCE: ;Adapted from 1972 Census of Manufacturers, 1972 County BusinessrPatterns, and Census of Population: 1970 Occupation by Industry (all are'Department of Commerce, Census Bureau
publications)
~ , I '
i. i~H.:
...,
';',
FMSI 06262
. 1. . .
- !I
:
I' '
'I
....
..
:
I
j
I
..
..
..
RECOMMENDED (INTERIM) PROCEDURES FOR ASBESTOS BRAKE AND CLUTCU SERVICING
. ....
': I ,.
1
-~. -~
_//
!_.. I
I
.,;j
I' II ,,1
II,i..
j
i ft
I.
.... ...
The National Institute for Occupational Safety and Health (NIOSH) has
research underway concerning dust exposures during brake and "clutch
servicing. Due to preliminary data demonstrating significant asbestos
.exposures during presently used brake and clutch servicing techniques,
NIOSH reduc
e
ha d.
s re The
'viewed altern
fol~ow~ns are
ate inter
tec im
hniques procedu
whereby asbestos res :recommended
exposures by NIOSR
are to,
minimize dust exposures.
1. If possible, an area shall be designated for all brake and clutch
repairs. Entrances into this area shall be posted vith an asbestos
exposure w~nins sisn as follows:
I __
Asbestos Dust Hazard
Avoid Breathing Dust Wear Assigned Protective Equipment Do. Not Remain in Area Unless Your Work Requires It
Breathing Asbestos Dust May Cause Asbestosis and Cancer
'.:-.,
' '
2. During brake servicing, an air purifying respirator, either single use , or with replaceable pArticulate filter(s), a~ a~proved by the Mining
Enforcement and Safety Administration (formerly Bureau of Mines) or . NIOSU, shall be worn during all procedures starting with--t-he- removalof the wheels and including teassembly. During manual clutch-servicing, such a respirator shall be worn during removal and cleaning of the clutch, pressure plate and houing assembly and during installation of the new clutch assembly
.3. Dust shall first be cleaned from brake drums, brake backing pla.tes, ' brake assemblies and clutch assemblies using an industrial type vacuum cleaner equipped with a high efficiency filter-system (>99% efficiency
for 0.3 ~m diameter ae{osols). After vacuum cleaning, any remaining dust shall be removed using a rag soaked in water and vrung until nearly dry. Under no circumstances shall compressed air or dry brushing be used for cleaning.
..
.
', 4. During arcing and riveting. opera~ions, an approved respirator, as
described in (2) above, shall be worn. 'Grinding' (arcing) machines
shall be provided with lotal exhaust ventilation such that worker
exposures are maintained at least below the 1976 OSHA asbestos standard (29 CFR 1910.1001.).* ' At a minimum, the dust'bag of the
..
arcing machine shall be removed and replaced with the bose of the, high
efficiency industrial vacuwa da1cribed ia (3) above.
..... l .
: ... ,
I
.. ! :
l ~
l
, 1 ,'
,.' I '
'I :
-'-------~-......-;........ ,,. ... : '
. ..j'
\,. :'
'1, .. ;' ,~',-r-,'.-.""' ~~~r~~~.~':"":"'~----:~-
, r '
.,. 1/ I. I, i .
I. ' t, I' . '.,I,
'I .,. . , , ' ... ' .1 ' I I
' >' ' ' . I., I '
...
iI :. I' ' ' '
0
r,, , ', .' '' ..,. '"
II
'
' .. :
:
,' '
, ,:
.\\
,
' I
' i,If : '
FMSI 06263
. , '
.~l
..'
."
.1~ '
r...,... .."..
~ . ..''1 I
'
-2-
I
5. Industrial vacuum cleaner bags containing asbestos d~st.and cloths
,.
used for wiping brake and clutch assemblies shall be seated in plastic 'baas and labeled with the following warning label printed in lettera
of aufficient aize and contrast to be readity visible aQd leaibl~
.
.
Caution
I .:.J,~~
Contains Asbestos Fibers
.. ,.
Avoid Breathing Dust
.Breathing Asbestos Dust May Cause Asbestosis and Cancer
:\
All asbestos waste shall be disposed of in accordance with the OSHA
asbestos regulation, 29 CFR l910.100l(h). During removal of va~uum
bags, an a;proved respirator, as described in (2) above, shall be
worn.
.
; . -- .. ~.-. _~
' All floor cleaning in areas where brakes and clutch~''&'"'I are repaired shall be done with the high efficiency industrial vacuum cleaner as described in (3) above. Grinding (arcing) machines shall also be
cleaned with such a vacuum cleaner and.any remaining dust wiped with a damp cloth'. An approved respirator, as described in (2) above, shall
be used durin& this c~eaning.
7. Although adherence to the ab~ve procedures should minimize any
.... contamination of work clothing, it is required that the appropriate portions of the OSHA regulations on asbestos (29 CFR 1910.100l(d), (3 and 4)) concernins special clothing,: chanae rooms, etc. be followed.
NOTE: Strict adherence to the above procedures should minimize exposures
to mechanic& during brake and clutch servicing. These are interim recom- .__- ---
mendationa and are aubject to reviaion pending result& ~f ongoing N10S~ .
reaearch.
..,
--.
., .
Section 1910-.1001 of the Code of Federal Regulations vas formerly
Section 1910.93a. Tbia change waa noted in the Federal Regiater, May
-28, 1975.
Prepared By Division of Pield Studies and Clinical Investigations
National laatitute for Occupational Safety and Health Cincinnati, Ohio
. ..
"-
. ..........
'.
! ' :
' ''
F 8&
I
'
\
. .' '
~ ~ .' 4 -.
t.,'. I
.. l, (', ''I
~'
& JJ.
,l ' I
\
40 ......._.~~~
' I'' I 1,\H ... 1 t \I 1 \
FMS\ 06264
l
.r.
''
i
'l'
i
!
(
!
Hcconuncndcd Procedures for Smnpling and Counting Asbestos Fibers
Procedures for the Evahmlicm of Occup11tionall~xposurcs to Airborne Asbestos
Joint AIHA-ACG/H Aerosol Hawrd~ Evaluation Committee
F IBROUS ASBESTOS HAS BEEN IDENTIFIED as the causative agent of asbestosis and has been associated with an increased cancer incidence. The American Conference of Governmental Industrial Hy-
fibers per square centimeter. At least 2% to 4% of the filters intended for collecting samples should be set aside to determine the background count. (Sec Counting and Calculations sections). In addition, the filter
gienists (ACGIH) has established (1974) a resistance should not exceed 3 mm of mer-
Threshold Limit Value (TLV) for asbestos cury when filtering air at the rate of 0.3
of 5 fibers greater than 5 micrometers in liters per minute (lpm) per square centimeter
length per milliliter of air. A TLV footnote specifics the determination shall be made by
of filter. When collecting the sample, care must be
the membrane filter method at 400 X to 450 X magnification and with phase contrast illumination. These procedures define a standard of sampling and of processing the collected samples in order to evaluate occupational exposure to asbestos fibers.
Sampling
taken to prevent dust from falling <:>r from being projected onto the open filter. This may be accomplished by pointing the filter head downward. A guard or shroud should be attached to the filter holder to further protect the open filter from contamination as well as optimize uniform deposition on the filter. Its diameter should be about the
Airborne samples of asbestos must be collected on membrane filters which retain at the surface essentially all of the particles in excess of 0.5 J.tffi in diameter. The filter must be rendered transparent by the mounting medium. The filter should be packed in a scaled holder which is capable of being readily opened for sampling purposes and of being rescaled after the sample has been collected. The filter must be fully exposed during sampling. (Recommended filters and filter holders arc listed under Supplies). The filter must be practically dust-free, with an average background count of less than 25 .
same as the holder so that it can be--attached tightly to it and it should project at least 1V2 times the filter diameter in front of it. A protective device is particularly important if the filter head is to rest on contaminated clothing. (Sec Figure 1.) The filter holder may be stored for a limit of six months once it is resealed.
The sample should not be too dense, since samples in which particles overlap must be rejected as uncountable. Similarly, a large enough volume of air should be sampled so that there arc sufficient numbers of fibers in each field. Experience indicates that more than 150 particles per field, including non-
fibrous background, may interfere with
I
Reprint of this article arc available for purchase from
counting the sample. It is desirable that
.1,
cilhcr the American Industrial Hy~icnc Association, 66 South Miller Rod. Akron, Ohio 44313 or tbc Amcrlcon
there be no more than 10 fibers per field.
Conference of Govunmcntal Industrial Hy&i<nlltl, P.O.
Two or three samples should be collected at
Box 19J7, Cincinnati, Ohio 4'201. The coal 11 $1.00 per copy.
each sampling location. The results should
~
i !
I
t
83
Y- 2- ~
(F)
FMSI 06265
'' 84
Fl'br11ary, 1975
-1 tFILTER AND
U 3D
b
FILTER PAD
Hii
~tl
-~C~LI-P--~-------------c_"'_P TAPED IN PLACE
Figure 1. Diagram of shroud for membrane filler holder. The shroud may be constructed from a plastic bo.ttle hy cutting off the neck and drilling a hole in the bottom. To use, push the filter holder through the hole and re;1ch in through the top to remove the holder cap. To remove the holder, rc ph1ce the cap and push the filter holder forward through the hole.
be averaged to obtain the fiber concentration.
Breathing zone samples should reflect the worker's entire normal work day. They must be collected as close to the worker's nose and over as long a time period as pm.sible. Calibrated battery powered personal pumps (sec Appendix Ill, Pump Calibration) are satisfactory air movers. They can be worn by the worker and supported at the belt by means of a clip. The sampling head, which can be pinned to the collar, is connected to the pump by flexible tubing. Such pumps can be operated continuously for about eight hours and recharged overnight.
If a 37-mm filter is used to collect the sample, the pump should be adjusted to sample between I and 2 liters per minute. The volume of air sampled should be adjusted so that un optimum density of dust is collected on the filter. Since the dust concentration is not known before sampling, the optimal sampling period must be determined by trial and error. It is suggested that, uniess experience indicates otherwise, the first sample should be collected from 20 liters of air, the second from 40 and the third from 80
liters. If a filter other than 37-mm is used,
the volume of air sampled should be altered
in direct proportion to the open filter area.
Samples collected during short- periods of
exposure should be collected at a high flow
rate and if necessary. for the entire exposure
period. In all cases the count should be
adjusted with regard to time, so that the
exposure is expressed as an 8-hour time-
weighted average exposure. For compliance
evaluations with short term exposures, 37 mm filters samples should be collected for 15 minutes at a minimum of 2 lpm.
Sample Preparation
A solution one-to-one by volume of di-
I'( I ! L
'Jloi;,
methyl phthalate and diethyl oxylate in which has been dissolved 50 milligrams of membrane filter material per milliliter of solution is the preferred counting medium. The chemicals used to prepare the medium should be examined microscopically to be certain that they are dust free. The fiber material to be dissolved should not be marked and should have a maximum back-
t
!
i
I
i
II
L
ground count of 25 fibers per square centi-
meter of filter. The counting medium may
be stored in a wide-mouthed Wheaton Bal-
sam bottle and should be applied with a
glass rod. The counting medium has a re-
IIfractive index of 1.461 at 25C. The me-
dium should be made in small quantities
since it has a 6 month shelf life.
Asbestos fibers are counted on wedge
shaped sections cut from the filter. The
wedge should be reasonably sized so that
it can be mounted on a 25 x 75 mm (I x 3
inch) glass microscope slide. The slide
should be cleaned of dust before it is used.
A drop or two of counting medium is placed
on the slide and the filter wedge is placed
dust side up on top of the medium. The
wedge is covered by a No. 1lh coverslip.
Care must be taken while lowering the cover-
slip to avoid trapping air under it. Air bub-
bles may be forced out hy exerting slight
pressure on the cover slip with a pencil
eraser. Extreme care must be taken to avoid
FMSI 06266
8S
too much pressure, since this causes distortion and -stretching in the filter.
The wedge is usually cleared within 15 minutes; however, a residual background grnnularity may be noted. This will disappear within a uay. Counts must he completed within two days since there is a tendency for fiber migration and crystal growth. 1nc prepared medium should he cliccked pcriouically for a b:~ckground count. (Sec Countin~ and Cnlculnlions sections.)
An alternate medium may be used when the samples must be counted imn1ediatcly. It is prepared in the same manner as the preferred viscous medium, except that the added membrane filter is omitted. Since this medium is much less viscous it should be stored in narrow-mouthed bottles. This medium is applied with a glass dropper after the filter wedge has been placed dust side up on the slide. However, a drop should be placed on the slide adjacent to but not on top of each corner of the wedge. This medium acts very rapidly and the No. 11h coverglass should be lowered within a minute. Slides made up with this "alternate medium" arc ready for counting within five minutes and the count must be completed within two hours after preparation.
Filters which have been used to collect samples and which have been resealed in a holder should be removed only in a clean environment. They should not be held with the fingers. They may be held with tweezers and cut with either a scalpel or scissors. Bottles containing media must be tightly closed except during usc. All bottles, tools used for handling and cutting filters, and containers used for storing tools must be thoroughly cleaned and dried. Tweezers, scissors, scalpels, etc. should be set aside for this purpose exclusively. Although slides and covcrslips arc purchased pre-cleaned, they should be wiped lightly with clean lens tisue to remove traces of dust. Do not attempt to reuse slides or coverslips.
Microscope A microscope equipped with a phase con-
trast substage cotllknser, a 4 nun "high dry" phase-contrast objective (40 X to 45 X) and a I0 X eyepiece is used to count the san1pk. It should have either a pre-focused built-in illuminator supplied with an iris diaphragm or he lighted hy a separate bright illuminatornat mirror combination. If a separate illuminator is used it should be equipped with a condensing lens, iris diaphragm, and means for adjusting both the illuminator level and the distance b~twcen the condensing lens . and the bulb. Zoom microscopes may be used for counting asbestos fibers, provided that the totul magnirication is within the 400-450 X range.
The illuminator should be equipped with an adjustable constant voltage transformer. Both the microscope condenser and stage require close adjustment and both should be rack and pinion mounted. The stage must move along two perpendicular axes in a horizontal plane, while the condenser must move up and down in a vertical plane. Lighting must be adjusted for optimum balance. The Kohler method of illumination is recommended. (Sec Appendix I for procedures required to establish Kohler illuminator.)
The counting field is defined by a reticle mounted at the level of the field-limiting diaphragm in the 10 X eyepiece. The Porton reticle (Figure 2) is recommended. However, any reticle which contains markings which, in addition to. outlining an area of about 0.005 square millimeters, as determined by
19
... ooooIIJlJC? OQ
t: e to n
11
Fiauro 2. Porton reticle.
I
I .,.!!J,
I.
t
i''
I
l
I
t f
i
FMSI 06267
86
the combination of eyepiece and objective, and which dcincs linear distances that may serve as measuring aids, is satisfactory. The :_:;reticle ~lUSt be calibri1tcd prior to USC and . . "": r~callbrated. each tiinc it is removed from the microscope eyepiece. or when the microscope tube length or interpupillary distance is changed. Zoom microscopes must be rccalibrated each time the zoom position is changed. (Sec Appendix II. for recommended calibration procedures.)
Counting
A fiber is defined as a particle whose length is at least three times greater than its diameter. All fibers longer than 5 p.m within the area delineated by the reticle, or which enter it from either of two adjacent sides, arc counted. Fibers entering the area from either of the other two sides, i.e., those not arbitrarily chosen as "counting" sides arc not counted, nor fibers in excess o( 5 ILm in diameter. Touching fibers, i.e., one of whose ends touch another fiber regardless of the resulting angle, arc considered as one. Fibers that cross each other arc counted individually. Fibers that pass through the delineated area arc counted provided that they cross at least one of the arbitrarily chosen "counting" sides. (Sec Figure 3.)
Fiber length should be determined by measuring against standards such as a circle or a space dcincd by markings on the calibrated reticle. If the fiber is curved or wavy the total length should be cstimatcp by measuring along the curve. Once sufficient experience has been gained in judging length, only fibers whose length or diameter arc in question need be measured.
A routine for choosing counting fields must be sdcctcd so that fields arc not counted more than once and that a representative fraction o( the total filter area is viewed. A convenient procedure which may be used is to select a series of microscope viewing fields along a radial line extending from the apex of the filter to the outer edge of the sample wedge. The viewing fields must be
F<'bmary, 1975
chosen without preference to a particular area and should be approximately equally spaced along the line. The first field should be located a little bit in fronf ffic -point at which matter is deposited on the filter. If the required number of viewing fields cannot be located on a single radial line; additional lines parallel to the first should be chosen.
Preferably 100 fibers should be counted but all the fibers in 20 fields should be counted even if there are more than 100 fibers. The counting may be terminated after 100 fields have been searched even if 100 fibers have not been counted.
Cnlculations The concentration of asbestos fibers in air
can be expressed as:
Asbestos Cone. = Fibers x R
Fields x Vol
Figure 3. Illustration of fiber counting with a l'orton reticle. The lop and left side of the large box have been chosen as "counting sides". Circle 6 isS 11m in diameter. (A) Fiber A cro~~es the top of the box and is counted, therefore. One end of Fiber A 1 touches Fiber A and thus is considered as pnrt of it and is not counted separately. (8) Fiber II is a bundle containing many spike~. II passes through the box crossing bollom and top, It is counted as one fiber. (C) Fiber C passes through the box but it cmsscs the right side ;Jnd bollom. It is not counted. (D) Fiber D is entirely within the box and crosses over Fiber A. It is not part of Fiber A, therefore it is counted as a separate fiber. (E) Fiber E is less than ' ~m In length. It is not count ed.
1
t
I
I
I
l
I
I
!I
lr
I
I
I l
'l
I
~-
t
I
I
L
----
';
FMSI 06268
'
A mtricau lmluslriallly~:irll<' A.uocialimr hmmal
87
where: Fibers = total number of fibers counted Fields = total number of fields counted
R = filtration area
area of a counting field Vol = sampling rate (lpm) x time (min)
X 103
= sample volume in ml of air
Since both the filtration area on the membrane filter and the area of the counting field arc normally constant, the ratio of areas, R, is constant for the given conditions.
To illustrate: Air is sampled at 1 liter/ minute for 50 minutes on a 37-mm membrane filter (filtration area 855 mm2). A total of 60 fibers each longer than 5 p.m are counted in 100 fields each 0.003 mm2 in area:
R = 3 :~~~:2m2 = 2.8 X 105
and
=Asbestos
2.8 x JO:i x 60 Fibers
Cone. ------;:----:~;---:------
100
F
. ld
1e S
X
1
x 1()3
nun
ml
.
X
5.0
.
mill
. ;= 3A Fibc~~~~~- : ,. _
Since the precision of this metrfod.,is limited,
the averaged results of the several samples
should be reported to the nearest significant
figure.
Appendix I
Recommended Procedure for Establishing Kohler Illumination
The microscope is set on a level .mrface at a convenient height and in such position that sighting through the eyepieces is possible without undue strain or discomfort.
The illuminator is placed direc~ly io front of and aligned with the microscope. If the illuminator is equipped with a coil filament bulb, its iris should be ten inches from the mirror. If a ribbon filament bulb is used, the front of the filter holder should be at least seven inches from the mirror. Only the plane surface of the mirror should be used. All filters should be removed from
the system except that if desired, neutral density filters may be used to reduce the light intensity. If the microscope is equipped with a built-in illumintttor, proper ill!!,mjnator positioning has already been accomplished and need not be of further concern.
Fix a mounted sample on the stage and recheck the alignment. Raise the substage condenser until it nearly touches the bottom of the slide. Turn on the illuminator and usc the tilt controls to direct the light to the .center of the mirror. Tilt the mirror, directing the beam upward into the stage condenser. Close the microscope substage iris and the illuminator iris. Usc the illuminator focus control to focus the image of the filament on the "bottom of the substage iris. The reflection of the iris may be viewed in the mirror by leaning over the microscope.
After adjusting the illuminator condenser so that there is a sharp image of the filament on the substage iris, open it about halfway. Recheck proper position of the mirror and then put the objective in place and focus sharply on the sample. It may be necessary to open the substage iris during focusing.
After the sample is in focus, fully close the iris. Readjust the condenser height so that the edge of the iris leaves are in sharp focus and there is a bright spot within the iris. Readjust the mirror to obtain maximum brightness. If the color around the iris is not uniform, recheck the illuminator tilt and focus. If the color is uniform and maximum brightness has been achieved, open the field iris until the blades just pass out of the field of view.
The proper phase stop is inserted or rotated into place in the substage condenser. The phase objective is rotated into place. The eyepiece i!! replaced with the phase ring centering telescope. The telescope is adjusted for sighting. The location of the phase ring is observed through the telescope. It may be adjusted by using the two rotating sha(ts provided with the phase condenser. When the ring is centered it appears as a
bright annular ring mounted on top of a
FMSI 06269
I 88
Ff'lmmry, /975
grey ring. ll1e center is black. There should
is related in terms of L units of length in
l be no overlap of the bright ring into the center. When the phase stop is centered the re-telescope is removed and the eyepiece is placed. The microscope is now ready for Iusc.
accordance with the formula:
D == Ly2N
where n is the diameter of the circle or the
width of the space and N is the number of
the circle, or space.
I
Appendix II Recommended Procellures for
The unit L is determined by measurement. A stage micrometer is the primary ruler. Any one or more of the definitive linear di-
I
Calibrating Reticle
mensions may be measured. If the length
The reticle must be slightly smaller in diameter than the eyepiece in which it is to be used. It fits into tbe tube and is held in
of the large rectangle is measured then L equals l/200th of that value.
If the stage micrometer is marked in hun-
I
place at the eyepiece focal point by spring dredths of millimeters the value of L is in
pressure. The focal point is marked by an
hundredths of millimeters. If the left square
internal collar which prevents the reticle is used as a counting area, its area is equal
from passing further into the tube. Some to
manufacturers locate the focal point just
fi'
(JOOxO.Ol L)2mm2
i
below the collar while others prefer a point
The filtering area of a 37-mm filter is 855
I
immediately above it. Thus it may be nec-
mm2 and thus
I essary to insert the reticle between the lens
! and the collar on one microscope and below
R = 855
l the collar on another. In either case the
L2
I
projected image of the reticle on the field must be clear and sharp.
The reticle must project a constant counting area as well as provide markings for sizing. Many types of reticles are satisfactory. The Porion reticle illustrated in Figure 2 is recommended. It outlin~s a large rectangle that fits easily within the field of
If other areas arc used as counting fields
or other sized filters are used, the value of R must be calculated for the individual con-
)"
I:
dition.
,!
It is wise to prepare a chart showing each ~~
Ilinear dimension and area for ready reference Iwhile counting.
vision. The rectangle is divided into two equal squares. TI1e left square is further divided into six rectangles. Each side of each square has a length equal to 100 L, then the large rectangle is 200 L units long and the small ones 50 L units long and 331;3 L units high. To the left of the left square is a scale which divides the side into 20 equal increments of 5 L units each. The right square is uividcd horizontally in thirds corresponding to the small rectangles ami vertically into a series of increasing spaces. The distance between each vertical line and the center of thl' large rectangle corresponds to the diameter of a circle. Circles of sizes I through 9 arc located above and below the large rectangle. The diameter of each circle
Appendix III
Pump Calibratio"
Personal sampling pumps should be calibrated for fiowratc frequently. They may be calibrated against a primary meter such as a spirometer or against a previously calibrated secondary standard such as a wet gas meter or dry gas meter. The train should be arranged so that the pump is operating against the same resistance it would normally operate against, and that the calibrating meter is at atmospheric pressure. Figure 4 illustrates the rceommemlcd arrangement. Air flow through the filter may be limited by both restricting the air flow to the pump ns well as by admitting-secondary air into
, l
t
I
I
I
I
~
I
===-----~--------------------r-----'-
.,
l
I
----------------------------------------
FMSI 06270
.,...~ . :. .'
I
\'
Amuic'anlmlu.rt,.ialllygit!lll! As.wclatlo11 Jmmwl
I
1
l PlLTEJI HOLDEit
l '""' t IIIE'T~It.
I Figure 4. Dhtgram of set-up for calibration of
I pump.
l the pump. Most personal pumps arc con-
i structed with adjustment valves that permit
both actions. Calibration should be repeated
! after each 24 to 36 hours of pump usc. If
the pump has not been used for a prolonged period of time it should be rccalibrated. Temperature and altitude corrections should be made.
Personal sampling pumps should not be used to such an extent that the batteries arc allowed to run down below normal operating voltage. Since battery life varies, it is wise to occasionally check the life of the battery by allowing the pump to run down to the first indicated change in voltage under timed simulated conditions.
Supplies
Filters and Filter Holders
Millipore Corp. Field Monitor filter hold-
ers prcloaded with 37-mm Type AA filters,
either white plain (catalog #MAWP037AO)
or gridded ( # MAWG037AO) arc recom-
mended. These are sold with a guaranteed
average p;;rticle background and can be used
without :1dditional background checks.
It is less expensive to purchase unloaded
field monitors ( #MABG037AO) to be
loaded with plain or griuded filters pur-
chased se para te Iy in packages of I00
( #AAWP03700, and AAWG03700). The
field monitor can then be reloaded nftcr
each usc. However, it is necessary to care-
fully clean the empty monitor and to check
I
!
the background count on filters in the re
loaded monitor.
89
Type AA fillers can he used in any diameter in any non-leaking open-type filter
Iholder, as long as proper adjustmeni is made
in the calculations for the change in filtering area, ami periodic halkground checks arc made.
Membrane fillers of other types and manufacturcrs cannot be recommemkd at this time, either because they do not become optically clear in the mounting medium or because of excessive particle background.
Personcll Battery Powered SampliiiK Pumps (I) Casella" MK II or MK Ill Personal Sampler (2) MSN Monitaire Sampler, Model G. (3) Dcndix'1 VM 22 or Micronair Personal Sampler or C-115.
Microscopes: Phase Equipped .
(a) microscope body with a fine focus
accuracy of 0.006 mm;
(b) 10 X eyepiece;
(c) mechanical stage;
(d) illuminator (preferably built in and
having provisions for adjusting light
intensity);
(c) 40 X to 45 X (0.65 N.A. at least)
positive (bright field) phase-contrast
objective;
(f) annual ring condenser diaphragm
(corresponding to the objective); and
(g) phase ring centering telescope.
(Note: Most manufacturers sell u basic
body unit and built-in illumination system as
a unit. Phasc-c.ontrast accessories can us-
ually be purchased as a kit consisting of
I0 X, 40 X and 90 X phase objectives, a
phase condenser containing appropriate an-
nular ring diaphragms, a phase ring center-
ing telescope, and a green filter. It is to the
microscopist's advantage to purchase the
kit.)
A list of manufacturers of phase-contrast
microscopes and reticles' is given below tn
aid in selecting a proper instrument.
i .,
MIIIIP<"re Corr., Bc~C<ttll, Ma"' 071 )0. Wlllo<1n Pn~uct Oiv., 1'.0. Dux 1\22, Rcn~ln~. Penna. 196113. C, P. Cmll'IID A ('u. 1.1~. R~IU'nl lh>ull', Rrilannla
';
FMSI 06271
90
Wulk, Lon~on, N.l, En~land, < Minc Salcty Appliancr Co., 2111 Braddock Ave., Pill,.
hur,:h, Jcnna. 1S20H.
Dcndix-NEI, 1'.0. ""' 590, l'nll River, Ma... 02722. Bau~h and Lomb, Sci('nlific Instrument DiYiskJn. 726~4 llausch Street, Rochester, N.Y. 14602. Olympus Microscopes, Micro Optics Company, 2816~ Grecnficl~. Southliel~, Mich. 4R075. American Optical Corporation, Rdchen Produces, Dul (nlo, N.Y. 14215.
Frbruary, l97S
E. lrllz Inc., Rocklel~h. N.J. 07647, Nik<>n Inc., Instrument Division, Garden CIIJ, N.Y. 11530. Unilron ln<lnoment Company, Microac.ope Sales Division, 66 Needham Streel., Newton Highland, Mus." 02161, Carl Zeiss, 444 Fifth Avenue, New York, N.Y. 10011. 1 Edmund Sclentllic Co., 701 Ed10rp Bulldln1. Barrina ton, N.J. 07007. BGI, lncorporaled, 511 Guinan St., Waltham, M 02154.
Joint AIHA-ACGIH Aerosol Hazards Etalualion Committee
AliiA
ACGill
Morton Lippmann, Ph.D., Chairman J. LeRoy Halzer, Ph.D. Douglas K. Craig, Ph.D. Graham W. Gibbs, Ph.D. William C. Janes William H. Krebs, Ph.D. Carl A. Mangold Eric B. Sansone, Ph.D. Marvin Tillery Thomas F. Tomb Russell W. VanHouten Wesley R. VanPelt, Ph.D. Donald L. Webster
Howard E. Ayer George Carson, Ph.D. Harry J. Ettinger Murray Jacob"son Geoffrey Knight Jeremiah R. Lynch G. Major Owen Moss Milton Scheinbaum Glen W. Sutton
,,
Industrial Hygiene Training in Israel
Medical and engineering students at Tel Aviv University will be obligated in the future to undertake training in occupational safety, hygiene and health to inspire them w"ith an awareness of their obligations for the maintenance of the health of the worker and for the prevention of ill effects from work on man.
This has been made possible by the establishment in 1974 by the Faculties of Medicine and Engineering of the University, in collaboration with the Ministry of Labor, of the National Insurance Institute and the
Workers Health Insurance (Kupat-Holim) of a Center for Occupational
Safety, Hygiene <md Health, with four major departments-Physiology of Work and Rehabilitation, Occupational Toxicology, Occupational Hygiene, and Safety Engineering. It comes to fill long-standing gaps in the promolion of safety and hcallh of the working population in Israel and the absence of training facilities for specialists in these fields.
The new Center will immediately provide refresher courses for physicians and nurses, but curricula for the training of Occupational Toxicologists, Hygienists and Physiologists arc in preparation. Ultimately the Occupational Health Physician will also be trained at the Center.
Due to lack of suitable personnel in the country the Center is seeking to recruit specialists from abroad.
I
l
I I
I
t
-(
FMSI 06272
TEU:J'HONI: ( 20 () 94!1-0440
FRICTION
MATERIALS STANDARDS INSTITUTE,
BERGEN MALL OFFICE CENTER E. 210 ROUTE 4
PARAMUS. N. J. 07652
INC.
February 23, 1977
Subject: Recommended Procedures for Reducing Asbestos Dust During Brake Servicing
Gentlemen:
As I'm sure you are aware, there have been questions raised concerning exposure to asbestos dust during br&te servicing. Actually, waat applies to brake servicing might equally apply to clutch servicing, except that ordinarily installers do not drill, cut or grind ne't'l' clutch facings in the field.
As a result of the concern expressed in several quarters, n~o committees and our Board of Directors reviet11ed the problem, and have endorsed the enclosed "Recommended Procedures for Reducing Asbestos Dust During Brake Servicing."
It is felt that these are sound and workable procedures, and we suggest that your publication may t7ish to give them ~~ider distribution, either in a brief article on as0estos, or in a separate commentary on the subject.
You are free to use these recommendations as you see fit. There is no copyright involved, and it is not necessary to give credit to the Institute. If you 'tYish to give credit, you may.
We believe that distribution of such information is in the best interests of all involved in the brake (and clutch) service business. If you have any questions, please let me knm11.
Sincerely, FRICTION MATERIALS STANDARDS INSTITUTE
EWD/lmc
E. w. Drislane
Executive Director
FMSI 06273
RECOMMENDED PROCEDURES FOR REDUCING ASBESTOS DUST DURING BRAKE SERVICING
Because studies have indicated that exposure to excessive amounts of asbestos dust may be a potential health hazard, OSHA has set maximum limits of levels of airborne asbestos dust to which workers may be exposed. Since most automotive friction materials normally contain a sizable amount of asbestos, it is important that people who handle brake linings and clutch facings understand the nature of the problem and know the precautions to be taken.
l. Areas where brake work is done should be set aside if possible, and entrances should be posted with an asbestos exposure 1;ign as follows:
Asbestos Dust Hazard Avoid Breathing Dust Wear Assigned Protective Equipment Do Not Remain in Area Unless Your W.ork
Requires It
Breathing Asbestos Dust May Be Hazardous To Your Health
2. The amount of asbestos in the dust from brake lining wear is normally at an extremely low level because of chemical breakdown during use, and if machining of friction material does not take place, simple procedures will minimize exposure. During brake servicing, the mechanic snould wear an air purifying respirator, either a throwaway or one with replaceable particulate filter(s), as approved by the mining Enforcement and Safety Adqtinistration or NIOSH. It should be worn during all procedures starting with the removal of the wheels and i1cluding reassembly.
3. During disassembly, all parts should be carefully
placed on the floor to minimize the possibility or
creating airborne dust. Dust should first be cleaned from the brake drums, broke backing plates nnd brake assemblies using an industrial type vacuum cleaner equipped with a high efficiency filter system. After vacuum cleaning, any remaining dust should be removed by using n rag soaked in water and wrung until nearly dry. Under no circumstance:~ should compressed air or dry brushing be used lor cleaning.
4. 01 extreme Importance aro the precautions which must be taken during machining of friction ma terial. This is the operation in brake ll!rvicing when exposure to aabett01 dust Ia at Ita highest. In addi-
t~on to the opproved respirator, there must be local exhaust ventilation such that the worker exposures are maintained at least below the 1976 OSHA asbestos standards. If there is any question as to the efficiency of asbestos dust removal by the machine, the manufacturer should be contacted.
5. Industrial vacuum cleaner bags containing asbestos dust and cloths used for wiping brake assemblies should be sealed in plastic bags and labeled with the following warning label printed in letters of sufficient size and contrast to be readily visible and legible: Caution Contains Asbestos Fibers Avoid Breathing Dust Breathing Asbestos Dust May Cause Serious Bodily Harm
All asbestos waste should be disposed of in accord" ance with the OSHA asbestos regulation. During
removal of vacuum bags, an approved respirntor, as described in (2) above should be worn.
6. All floor cleaning in areas where brakes arc repaired should be done with the high efficiency industrial vacuum cleaner as described in (3) above. Under no circumstances sl;10uld dry sweeping take place. Grinding (arcing) machines should also be cleaned with such a vacuum cleaner and any remaining dust wiped with a damp chth. An approved respirator, as described previously should be used during this cleaning.
7. Although adherence to the above protedures should minimize nny contamination of work clothing, it is necessary that the appropriate sections of the
OSHA regulations on asbestos be followed when
ceiling levels on asbestos dust exceed current stond ards. This could involve special clothing, change rooms, etc. At the very least the work clothes should not be tnken home but should remain at work for industrial lnundering.
8. Proper hygiene practices wilt help mm1m1Ze ex posure to asbestos dust. Wash thoroughly before eating and do not eat in the work oren. Remember, amoking is harmful to the health, and smoking coupled with breathing asbestos dust is extremely dRngeroUI.
CAUTION: DO NOT BREATHE ASBESTOS DUST - ::&~
FMSI 06274
.' .
-'. The H~zards o1 Asbestos ~or Brat-<:e ~Jlechanics
. ... ~
" If,
'
' ,..
l.
I
I
OARRV CASTLEMAN, LUCILLE A. CAMAROTA, AlBERT J. FRITSCH,
~U.>AN MAZZOCCHI, fll\d R06ERT G. CRAWLEY
.
ASnESTOS is the generic name of a group or hydrated disk pads, and clutch facings f~l' the past 50 years.
magnesium silicate mineral fiber~. There arc two Jacko and DuCharme ( 11) estimated that the United
groups of these mincra}s-serpentine (chrysotile) and States annually uses 103 million pounds of asbestos for
amphibole (amosite, crocidolite, anthophyllite, brake friction materials and 4.5 million pounds in
tremolite, and actinolite).. Ninety-five percent of the automotive clutch friction materials.
world's r~sbestos production is chrrsotile.
In 1968 Lynch reported tt1at becau~e of the heat oi
Reports c-r cpidcrnioloeic and pathological studies friction caused by braking, almost all of the asbestos in
( 1-4) re\eal that occupational exposure to commercial brake linings is transformed to a nonfibrous mineral,
l asbestos minerals enhances the likelihood of a number and a small fraction of asbestos escapes <:rs free fiber
! . of diseases-asbestosis and cancers of the lung, pleura, ( 12). Jacko and co-workers determined that vehicles in peritoneum, larynx, and gastrointestinal tract. The this country emit 158,000 pounds of asbestos per year,
time from onset of exposure to the time or clinically ap . or which 11.2 percent is retai~1ed in the brake and dis-
parent disease is usually more than 20 years. Cancer posed of during service ( 13).
from asbestos is not limited to workers who handle the
Brake mechanics have low and intermittent exposure
material. There are also reports or pleural and to asbestos. This exposure has been reported to be 0.79
peritoneal mesothelioma (tumors rarely seen in the fiber per ml time-weighted aver;~ge (fibers longer than 5
general population) in persons with family, or microns), with peaks up to 7 fibers per ml when brake
neighborhood, or indirect occupational exposure to parts are being cleaned { 14). The standard method for
.1\sbestos ( 4-7).
rcmov.ing dust from brake parts is to blow it out with a
r-.1esothclioma was the cause of death of a man who
had rr~ul;1rl)' s~1ndcd vinyl a~l.estos Ooor tile ( 8). Under
simulated conditions of this man's work, a maximum asbestos dust concentration or 1.3 fiber:~ per ml (fibers
longer than 5 microns) was found in air samples passed
through membrane filters worn by a person sanding vinrl asbestos (S). 'I11e trpe of asbt'sto~ now used in
domestic noor tile is chrysotilc-tbc same as that used
in brake friction materials, according to the Asbc.-stos
Information Association. A case of mqothelioma in a brnke m<'chnnic h:u been reported (9).
Clulllfili.ll'tiol rnt:lltih t1inltflitl ~~~,~ In ''"' \.JIIheft St.'ltcs for braking passcn!.:Cr eMs and trucks eo1\lain itn
average composition of 50 percent chrysotile by weight ( 10). t\~bcstos has been used for brake drum linin&s,
OA!r. Castleman, an trruiromnmtal n;ginur, wen with the Ctn/u fnr Scitnct i11 tht Public lrrltrul wlun this pafrr was Jmpartd; ht is now with the Maryland l'ublic lnttwt Rtstarch
Gruup. Dr. FriiJ,h is dirtclar of tht Ccnlrr fur Scima in tile Public lntarsl. Ms. Camarola is 011 ocW/atirmallualrl. nurst,
District of Colwnbin Dt/'nrlmml of 1/umun Rrsourcts. Ms. ,\[,.:,;,u,,lri wm n rrurmh as.w.:iatt, ~'ll'irnmnmtal Canur
Rrstc1rch Projrct, Emiromnwtnl Scimcrs Ulboratury, Afuunl
s,,wi Sclmo{ of MtJi,int, New rork City. Alr. Crawlty is G
uIOIIilarinn, ttimort Corti!IJ Dtparlmtnl of lltalth. 'ftMtlmt t#tjllnll to 1/mty Ct~,tlmlltfl, Mt~rylt~~ul l'tbll'<
l11ltrtsl Rtstcmh Gro~/1. JTIO Ntw Main Dining 1/all, U11ivmit1 of MMyland, Colltgt PtlfA, MJ. 207.12.
..
I
--. ! .
I.
I
I
1
I'
I
i
~I
l '
I
.,.
. ._,1
.t
:J.
., ~.3)
,. FMS\ 06275
.. '
:1r~"lllil~;n~'.!cd 01i.r hose. In iiJ70 ~n1ral rTports ( /.1-l.'i) ':" clt~cribc(l the k\'ds of nqwsure of br.1ke nwrhanit:~ to ,~ 0\'lhl'SlOS; ;1ltcr1Mtin f1 iction llloltcrials, and ~ptrific c.:haJl~ts in hr.1kc: rep;1ir pranires which would nduc.:c
the len~ls uf cxpo,ure.
E3allimorc nnd Washington Studies
1n Den mba I 'J7.2, the 1\;dtimorc~ Connt y Dtpartment
of llcalth ilbv11t \30
mes;r1aihkldisiaHl1)-Cp;n~t;ewmhiicnhlt'Op~I'orvaipchlccc.Jbrcaikreculr;e~pr01tior
senicc. These businesses included new c;~r :11HI truck
dralcrships, certified motor \Thide inspeuion st01tions,
and other concerns Old\cnising brake repair as a
speci<dl)'. Some of the cst.1hlishmcnts initiallr con
tilctcd h:\d cithcr gorH' uut '-If lJ~tliinc~5 or replied thai
thcr do not do br:~kc repairs. '!'he circular warned that
inhalation of the dust from brake cle;ming coulc.J ci\use
serious dise;1scs, including cancer, and 01<lvised
vacuuming br;1kes of accumulated dust. t\dc.Jitional
measures suggested were impro\'Cd \'entilation and the usc of f;~ce masks ( 19). Two sruclent volunteers went to 100 of tht: pl;ux~ on the 'm:1ilin~ list 4 mond1\ l.1ter to ask ~hop man<~gcrs what methods they were using in
brake repair. A similar studr was st:~rted in \\'ashington, D.C., in
August 1973. This work was conducted br the Center
for Science in the Public Interest and the District of
Columbia Department of !Iuman Resources. Of 186 brake service establishments initiallr cont;~ctcd, 120
were followed up. Several new methods were tried in
order to impro\'c the effectiveness oft he warning. The warnin~; lcaOet Wi\S more eye-catching and rt'i\dable than the par;~gr;ph-form sheet used in Baltimore; the
lcaOets were lwnrled out by an occupational heillth
011r.sc to the mechanics themschcs-none were mailed;
ancl follnwup to ascertain the degree of effectiveness
was conducted by the same nurse who interviewed
the rcp;lir shop managers. The \Vashington studr was
also featured in a loc;ll television program at the time
the leaflets were first handed out.
..... .. I ...., ,_,...: ,...~
......... --............ ,,,_;..................4 .... .
............,.,... '',.r,~~ol, ....,. ... _ ... ..,.
............ ..,. . __..-_"_'-!'__".,r.........-..._...,._...........,..".'.'"..
Do.U.,.'IllttTo!
........... ,_., -! ...............
......... ...-....~.-
..i
I
.......t4>O.-tM.
.
.........
.~.-.'..
.
I
t
_.....,.11, .......,1
~..;...:;:,:..;.........._....,.,
..-_ ,
..... ~
'.
ORAl([ RI:PAJR WORK
CA.~ BE
I/11J4Mt11J
10 lCUR HE.\tlll
................ ......,....- .. ........ -\4 ,..................... i .....................\ ~ ,~--'
............ -I"'''''
I
....., .......... j
.._.. .......,.J,I - .....,..............!
........ 4......... .
-M4W
_. . ,_ , __!"....",,4-....... .
- - ;~;~:.:! ............_.......-.~ .....,.-~oo..,,
... .....,_~_-.,..,...
......................,
..._..__ -........._,,, ............... ...!4-.-.---....................... ..........., __,
t1rtU>.... ,........ .,
.. ..............-- I .....................__. ____,...,....,.. ;:_:_:..:.:..-:!w..~-' N'tM
,.._oO- ..- .....
......... ~ ,,,,
~
I
~-~
I I ~:~:;;~~;;:..~,
:.-:: :..:::-:.:
~::.:::...~1
........,...,..__,
_,
..._
~
- ... ........-~
Tn nssure thnt litluhnts tr<inn.l in brake rtp;ir by
pul,lic vor.at ional schools would learn propcr IIH:t hods,
hr<~lth ollici;ds llll't wirh ii(IJ>~'~~I'Iiiltl: lid\0.,1 oflici;~ls in
both locations. At the time thrr were cunt;u.:tc~cl. sehoul
oHici;~l\ in 1\altirnon ;~nd \\'a~hington reported that the
schools were ttaching tlll'"l,low out" rn.~thud of lu:~ke
dust rell\o\;11 to the- tr;1inces.
,,
The swndard method of cleaning or;;kl.s i~ "blowing
out" ,,ith a compressed 01ir ho~e. In Baltimore:, 6) pr:r-
ccnt (65 per 100) of the brake repair cst:1blishments
contacted were usinr; this method :1t' the time t-licy
recci\cd the w;1rning tirculars. In \\'::;hington, tf1c
figure was 91 percent (110 of 120). :'\lost of the
managers and workers interviewed had nc\er heard
Jlbmtl lht: hnwrdou~ polcnlial or ~rnke di.!SI. Prctliet
ably, the responses ranscd from annoyance to apprecia-
tion.
Of the 6S places in Baltimore initiall)' hlmin~ out
brakes, 11 were using either \'acuum or wet brushing
methods at the time of followup. four others were still
blowing out brakes, b.Jt had irnpro"cd ,entilation or
provided du~t milsks,. or both, t.J n~ducc workas' ex
posures.
In Washington, only two establishments had
changed to wet brushing, hut noue were vacuuming
brakes. Four others provided f;ICe masks. lntercstJ.ngly,
two others decided to change brc1kc shoes in all or<~ke
repairs, thereby simplifying the problem of dus(
removal and reducing the mechanics' exposures.
The degree of improvement, indexed br the pcf.cent-.
age of establishments convf.:J'ting from blowing out
brakes to safer techniques after a single warning, \\'as
23 percent in Baltimore County and 7 percent in ___.
Washington. This disparity probably <~rises more from-
differences in the methods of the studies than from
differences in the study groups.
It may be critically importaqt to <~pproa'ch manage-
ment at the outset in order to enlist the cooperation
needed to implement any changes in practice. A
mcch;wic who is approached direct!)' with a ,.;arning
may simply disrcgnrd it. The mechanic might reason
that if the dust were real!) dangerous, there would be a
law requiring the usc of preferred metlwds in br.1kc
repair. And the emplorcr, if not asked to participate
from the beginninr;, ma)' well conclude that he need not
be concerned ,,ith the matter. The failure to imui\'c
m;~nagement may be the main reason why the
\Vashington stud)' proc.Juced less gratifying results than
the Bnltimorc study.
llrakc waming prof:rams consisting m~rcly of mailed
warning notices r,quirc lillie manpower, comp;1rcd to
other health prugr<1ms. Also, thl dfort to implt:mcnt
safe techniques in public \'OC;Hional :ocho\lls is Lime well
!ijlCI\t.
Conclusion
(),cr n 7-)'C;,r pniod ending in 197(, (20,.!1,1, thr l.i.S. tnndard for 1inw:l\'tra~ed l'XJHlsure Ill sh~stus will h:wc Ul'\'11 I'CUliCCd frum 5 million pa~r~id~o.s-pt'r cuhic
..i.
I
i
.
May-JuOII \075, Vo~ GO, No. ;) :ns
fMS\ 06276
,~.foot.of,lil' to 21dur, lH'f 1111 (Jd,n~ lou!;l'r llidll S ''. ruJ.t.:r.nli.~'J~ I''t>r a\hcsto~ texti.le p I0111b, LI11.S ntlll!'ti.OII .1~ ~ i,l~out 15-fuld ( 2!). l'rornt iiiHI ~cht'chdcd stillldarch
, cl:~i111 only to protect workers ar.:;1inst i'\SlJc~tosis, the di~c:1~~ for which the do,r-rcspon~c rl'htionship is mn~t qu.1ntitativl'lr known. The British ~tamlMds for chrysotilc and amositc il\besllls, which ;~rc cumparablc \0 the aslJcslUS standard ~t hedulcd 10 t;1kc r:Jkct in the Cnited St;ltes in I976, du not pur port tu prrwide protection against incrc;~scd risk of c;mcer ( 23,2.1). Previously studied cohorts of <~slwstos workers were
exposed tn timeill'er;;~cd nmcentr;~tions greater than 2 fibers per ml (fibers longer th.1n 5 microns). Current
studies of cohorts with time-a,er:~gecl exposure on the order of I l1bcr per ml (~re;1tcr than 5 microns in
length) m:~y prol'idc evidence of hazMcl ilt thilt lc1d. In
l'iew of alarming preliminary findings of pulmonilfy fibrosis in such a cohort, the National Institute of Occupational S:~kt)' and I Icalth has sugs('sted to the Department of Labor that consideration oc given to further lowering of the 'iisbestos standard ( 25).
The average brake mechanic is not ;;ware of the potcr,;ial h:u.Md of ai; born.: hri\kc dust. :'\or is he quir.:k to change time-hardened habits when warned of d:mgcrs if he cannot feel their effects. Nonetheless, substantial reduction in asocstos exposures during brake repair can be achic\e<.l by simple changes in technique, with the usc of equipment alrcad)l .available in most
brake service establishments.
In view of the tendency of ti1c accumulating literature
to reveal cancer induction from asbestos at progressive-
Ily lower levels of exposure, mechanics should be advised not to blow out brake parts and to usc instcOld
methods which c1eate less airborne dust. The manufac-
turers of auwmotivc friction materials could ei'\sily at-
tach a clear hazard warning to C\'ery item sold.
The limited success of both the Baltimore and \Vashington studies shows the limited cffic:~cy of voluntary compliance with health warnings-the shop managers and the mechanics simply do not have the same regard for a warning that they ha\'e for a regula-
tion. The margin of safety, if any, provided by the current ."'sbestos standards has blcn sh:~rply criticized as insufficient (26). While it IS adv1sab!c that brake
mech~nics at least be warned of the potential hazard of their work, it is also apparent that blowing Ollt.brakcs will be a common practice so long as hcnlth rc:guhllions
permit it.
Rtjnmrcs
1. Coop.-r, \\'.C., c1 al.: Asbcstos-lh( need for nnd fc.nibilitr ,,fair polhativn con1rot.. 1'\~Jion;.l t\Ciilh'm)' of Sciencr, Washin~ll>n,
D.C., 1'171.
1. Sdil.uiT, 1. J., ll.llliii>"'Hl, L C., iln<l \.hur~. J.: 1\I<Jrl:llil)' tx r('rit"(\('("j or ,ashr:~tus in;u1.uiun wor\..,u. /tr l'ruc('C',1int~' u( the
lnr,rn,"\l~on~tl Confcrrau.c un Pn.unwcunit1'Jii~. Juh;u,nt.. lJ\If~,
I>C.'J, ~Ji1~d b)' II. ,\, Shapiru. (hfurd llni\'l:ril)' l'r..n,
c~(<hMII, Suulh Afcira, I'Jiu, I'I' 11\ll-ll;(,, J. ~1rll, 1'. ;\I., ;ou<1 ;\(,(;ill, '1'.: o\llntos ,,nil l.orynt,:cal c.ul'iunn\0\,
l.olll\1'' 2: 41(,-~17, ,\tu; :tl, Ill/.\. I. ;-,;,.,.(un><l', ~1. I.. , illlll '111111111''"" II : ;\Jr,.tluhullll ul lloc
plrur,\ aucltn't ilnmuul (ullu\' iu..; r'P"'"' ,. lu ''''"''""' in I he Lnn
dun ar<'' llr J lncl ;\l,d :.!2: ~(ol -!t,') (l'll,i).
J.,.i. l.id,rn,
iUH.l PiH,I\\ k.l, ll.: ~ lt.;uthdiuu,,t anrl n..l.t"!\10'\ (")I.
l'""lh'. 1\rdo Lnl'irun ltr,dih 1-1: 5'.'1- ~(,:\ (1%'/).
li. J.\\',,~ncr, (;,, !';lc::. C. 1\., ;uul ;\l.url1.1111l, 1'.: llit(.,,r pkural
f1H'~11lhriatH11a :lnd ;, ... ltt,ln\ f"}lllll'tllrt..' IU lht ~o'flll \\'t'lf'l"ll C,1pC'
7.
l'rt11incc. l),olctoun,
llr 1'.,
.I !ncl ~ltcl
ll,cllrrl, :\
17: l
. r..
j
U-2 ;end
71 (l'J I 11111,
Wj. 1 1.: Elickuliulu;ic:
drr
l'kur<imrwlllt'liuona. \'nrliluli~cr 1krirht ubrr II'J L1llc ;nu drm
ll.,mhu'!;cr. R~urn l'r.l~ l'muu11l 2l: )1'1--SSII (1%'1).
8. ~lurph)', lt. t..., Cl ill.: Fluor lilc in\liollat,inll II\ a $C111H't of
<tsl.rIU upo~ure. ,\m ~~('\' l{pir Di 101: ~7(,- )!ill, o~ll>ber
I'HI.
'.
9. S11llian, R. J., iHHl Alhoona.-i;cdi, \'.C.: l'rrlimimory <lir pullu
tinn $ur.-ry tf a~tw,to>. N;otJ!lnal Air l'ullutiun Cmurol 1\d
:-.:.c:.,mini\lratiun, Al'rn CJ'>-27. R;,lci~,;h~
!%?, p. )2.
"''"'"U\1(1, 11~rwnod, C.:
air pulllltinn frum 1hc w~ar of hr,lkc:
linin!)' lllinni~ lnstituiC of Tnhnolngy l~ntMch lnstilutc.
Chic;,go, April 11)'/2.
/1, J~<ko, M.G., ancl DuC:h~rrnc, R.T.: Brake cmiHinn emi-.ion
n\ct~surclnt-nts from brake anU cl.:rh linins' (rum stlectcd nlnbi\c ourccs. f.nvirtnmcnc"l l'rorruinn Ascnq Jtcpon 68-0~-tO.!O.
1\nn .\rhur, 1?7l.
11. Lynch, J.: !Ieake linin!: tkrompo>iliun produ~u. J o\ir l'ulluc
Control,\.,oc 18: 821-62(, (I%S).
IJ. j01eko, ;\I. G., OuCharmc, R. T., and ~oonr;rs, J. II.: Brake and
clutch emissions during chicle opaHt1on. Paper presented ill Socicc~1 of i\utomoti,c Ent;inccrs :'o.kc:cins,'lhtroit, ~hy--1'>73.
IJ. llickish, D. E., and 1\.nighl, K. L.: F.xposure to ashc\los during
brake rn11inlcnancc. 1\nn Occup lin; JJ: 17-21 (19iCI).
15. ll"1ch, D.: Po~\ihlc ahern~ri,cs to asbestos as a fric1ion material.
Ann Occup llrg t.:l: 25-29 (1970).
lfi. Knight, K. L., and llickish, D. C:: llw<stig~cions into allcrnaJhc
forms uf control fur oust gcncr:u.d during the clcO!ning of brake
aucmblies and drums. i\nn Occup lin: 13: 37-)9 (1970).
17. l.tc, G. L.: Removing ousts from brake assrmblics during ~l,icle sc:rvicins-ahcrnativc cleaning methods. .Ann Occup lin; 1):
)3-)6 (1970).
18. l3cntle)', ;\I. L.: Control of the u\c .,r asbcstos-cont.,ining friction
m11tcrials. Ann'Occup.llro.: ll: 31-)2 (1970). I!J. li.S. Senate, Comrnillcc on Commerce: To~ic SubSianC"es Con-
Ira! 1\CI of 1973. I karin'<s l>dorc: the Lll\'ironmenc Sul.>com
mi11rc. St;llemcnc of B. Ca.stlrm"" 93d Cong. U.S. Govcrnmrm
Printinc; Office, \V"\hington, U.C., 1?73, pp. 117, )49-3SO.
:K? Cuenth~r, G. C.: Emergency s1.1ncl.utl for cl<posurc co asbestos
dul. FedcrO'II Rec;istcr, \'ol. )(,, No. 23-1, Dec. 7, 19~1, pp.
23207-2:\208.
21. Cucnthr.r, (;,C.: Siilntbrd for e~!"""'c tn 11\U<''"'~ "'"!.Federal
Rrc;islcr, vol. 37, Nu. IIO,Junc 7, l'l72, pp. !DIIl-lll22.
11. l.rnch, J. !{., 1\rcr, II. 1~. ;1ntl .John~on. 1>. "1.. : 'fhc in~
tarcl:uinmhip of sl'lc:nnl ;"bc:>tos cxpa.urt iudi,cs. o\m lnd Hrs
AHocJ 12: 5CJH-(o01 (l'l70). 2.J. l!y,.:icne JtaJ.ui:ml fnr ~hrpcllile ;ISI~;Ins dul. :\nn Orcup II)S
. II: 47--19 (l%!l).
o,.21. ll)'l:irlll' llilltd:ord f,r airborn<' illllll~it( a\Ol'""' rlul. """
cup II)'~ l(o; 1-S (1'17)).
25. Kc)', :.I. r.t.: l~c~up<nin~ ,,f '"'"'SI<I:I st"nd.ul. ;\lconc>r.,nclum 1oj.
Sl~lltll'(, ''";"'"'' s,.,.,.,.,,1f)' nf !olmr, Onup:lliun.Ll ~.lkly lllld
llt.,hh A<lmini>ll.otiun. OHin uf TNhniral l'uhlr;cti""'
N.uinn.lllmlituh' f,r ( kliiJMiilll.ll S.lr,c) nlulllc-.llih, H<K l.illc, :0.1<1., :C.I.mh 211, 11174.
J(i. (;(t, B., nuclllt>llllll)'~, A.: ,\niuntll\:l\hc~Lut. N l'.nf~IJ :C.Icu 21\~:
J:\17-1)111, J)n, 2, 1971.
. -.
I'
.! ..i
I'
I
I
l'
. --!-
2~5 Public: tloollh Oporta
FMSI 06277