Document RjKVyXZL4dRwbQ8kRqrEkqyM7
FILE NAME: Reynolds Metals (RM) DATE: 1974 RM009 DOC#: RM009 DOCUMENT DESCRIPTION: Internal Inspection Results - Asbestos Counts
W. J. Porter
H. M. Cole -
i R. H. Mansur
I S. J. Sansonetti, G. E..Spangler* B. R. Ward - M R P ________ _ _________
March 18, 1974
__ASBESTOS COUNTS - SAN PATRICIO PLAN
Listed below are the asbestos fiber counts on the samples obtained from San Patricio Plant.
Sample #
SP-1 SP-2 SP-3 SP-4 SP-5 SP-6 SP-7 SP-8 SP-9 SP-10 SP-11 SP-12 SP-13
Calculated Fibers/Filter Area
113,643/'*'
IB,940//-v"- t*8 9
75,762/ s*-" <7-17
122,113'
/**/
88,389/~
9,470 /j.*~ l - v f
15,784 /*>"- 3./tf
0
66,292 !/",>> '
6,313 0
0
i. 0
APPROVED:
R. E. Hughes
WJPrljo
W. J. Porter
RMC0800260000447