Document Rj2VORjV88dmQBp54pKRE0yZz

234 W. N. WITHEBIDGE 19. Flammability, explosibility. 20. Physiologic effects: toxicity, irritation, odor. Concentration oj Contaminants. The magnitude of dust concentration "loadings" encountered in air or gas cleaning may be exhibited on a sim scale: 100 g./m.* 10 g./m.* 1 g./m* 0.1 g./m.* 10 mg./m.' 1 mg./m.* 0.1 mg./m.* pneumatic conveying heavy loadings from processes moderate loadings light loadings; essentially clear effluents in daylight dusty workroom air acceptable concentration of "nuisance" dusts country atmosphere There is evidence that the concentration of solids in the range &pp|| pneumatic conveying has an influence on the effectiveness of cyclone aetraaBB There appears to be an improvement of separation at the high eoncent^^g somewhat in the nature of a large-particle "stampede," or a "carry along" ''* particles. In the case of electric precipitation, a high concentration of particles injpf! with the charging process and with the retention of charges by particles tffigjg reach the collecting surfaces. Accordingly, high concentrations affect thisf tion process adversely. Increase in the concentration or partial pressure of a gaseous cd-h.sM|lEj tends to increase the removal percentage in scrubbing towers. AssumingS Iow_e'qaillbriimr'coiicgfitra'ti'oir'a1rthe-gas-liqu,rd_interfffceran--iucrea,set3^ tration of gas in the air stream gives an increased "driving force," cauajw! gas to pass into the scrubbing liquid. However, if the liquid approaches straf with the gas, or the driving force is reduced, the percentage of gas trap across the interface into the liquid declines. ,'||i Concentration of a gas or vapor in the air affects the retentivity of adff and thus the percentage of the contaminant they will separate. Eqr|| regenerated adsorbent, the separation ratio may be essentially indef^jagffli vapor concentration in the air stream. As the adsorbent approaches saturatf<||| the gas being separated, its retentivity for that substance gradually drops'! Particle Size. A statement of the separating ability of an air cleahef. referemce'to''the'size'af''solid:orHquid'particlerremoyrM~if'a'S:ihdefitt|tiOTs ing the air-flow capacity of a blower without stating the resistondeafi^S come. In other words, a percentage figure for the effectiveness of a dust :s|||| is practically meaningless when standing alone. Performance specification! contain- a -qualifying. .phrase of the- following. fonn-when. solid-or-liquii&^ are involved: "... based on the fraction below------ microns"; ". .. .'i|ba| the fraction above------ microns"; or ". . . based on the fraction bet and------ microns." In some cases, where exceptional performance is expected, it is impll specify.not only the particle-size distribution of air-borne matter butSJ AIK CLEANING 235 SaSalysis. There is no universal method of measuring particle size Jtethe rating of air- or gas-cleaning equipment. |g$Shnstone's8 adaptation of data on characteristics of air-borne abilities of various separating devices on the scale of particle size, 'u'--yl<particles, generally considered those, over 44 /*, are easy to ^simplest types of equipment, including gravitational separators.