Quality Control Department
Industrial Insulations
Division Headquarters
Manville- Plant - Box 222 ....
ecember 22, 1970
..........
C. P. Weber - DHQ, N. Y. fe/
RECEIVED DEC 29 1970
cc: H. E. Konrad J. F. Mell S. J. Swiackey W. P. Hahn Stoddard Lane File Chrono.
New York Billerica Billerica Manville, Box 221 Manville, Box 221
\HO
MARINITE CAUTION LABELS INDUSTRIAL PRODUCTS
As you are well aware, Hopeman Brothers have refused to accept Marinite bearing the caution labels. Because of this, we have stopped "Caution" labeling all Marine products and are going to an ink stamping of the caution message.
In light of Hopeman's refusal to accept labels, we requested Billerica to inspect stock having labels and located at the bottom of several tiers of pallets.
Billerica's investigation yielded the following wire: "Went thru load of 3/4" 10 ft. Mte 36. Mat'l. on bottom pallet, had been in inventory since 9/29. Hazardous labels were removable without tearing label. Surface of panels was relatively dust-free, also surface hard. Pandux exceeded 55 units also removed labels from Mte. 65. Also removable in one piece.
Based upon the fact that labels could be removed intact from sheets labelled for almost 3 months and located under several tiered pallets, we