II. Aroclor Wildlife Project
y cvvt*/V>
.
The analytical support work for the Aroclor Wildlife Project can be divided into 4 areas.
1. Develop sensitive and specific ln-hand methods for identi fying Aroclor In our environment.
2. Initiate an outside toxicological test program and provide necessary analytical methodology.
3. To determine validity of methods used and the results obtained by workers in the residue area.
4. Monitor labs doing research on environmental contamina tion by Aroclors.
The following progress has been made In the following areas:
1. An F & M 402 High Efficiency Gas Chromatograph has been purchased and. set up. This system allows two column operation and a choice of 3 detective systems - electron capture, flame Ionization and micro columetrlc.
The GC electron capture system Is operational and has
been completely evaluated with regards to Aroclor sensi tivity and potential pesticide interferences using a QF1-Chrome Sorb W column.
2. The second column (DC 200 Anachrom ABS) will utilize both the flame Ionization and micro columetrlc detectors via an infinitely variable effluent splitter. The electron capture system provides an extremely sensitive
method for Identifying nanogram amountB of polychlori
nated biphenyls and possibly a semi-quantitative estima tion of amount present. The flame ionization micro columetrlc detector while not aB sensitive, should provide
a better quantitative measure. This Becond system is not operational because of electronic failure and has
not been completely evaluated. The characteristics of
the polychlorinated biphenyls on the 2 different columns and 3 detectors will provide for their almost unequlvocable Identification In unknown samples. Some thin layer and column chromatographic techniques have also
been investigated for the Isolation of polychlorinated biphenyls from pesticides which Interfere with the gas chromatographic determination. In addition to this work. Dr. Mleure has established the operating parameters necessary for the absolute identification of polychlori
nated biphenyls by GC/MASS.
MONS 035947
0 -14
0
III.
--
2. An outside toxicity study has been Initiated with Indus trial Bio-Test Laboratories and the necessary analytical support work completely outlined on paper. Some tissue samples are now in hand and verification of outlined procedure will begin soon. An alternate hot analytical approach using Cj* tagged Aroclor has also been outlined on paper and Is available should its use be necessary.
3. After closely reviewing the available literature, I find It difficult to dispute the Identification of the interferring peaks as polychlorinated biphenyls. Still we have not actually demonstrated this on real samples
in the labs. For this reason a letter to the Fish and Wildlife people at Patuxent Is being drafted requesting duplicate samples of some of the tissues In which they
believe they have found polychlorinated biphenyl. These samples will then be subjected to an absolute
QC/taASS identification. If polychlorinated biphenyls
are found, this still does not prove that Aroclors are the initial source of contamination. To help us deter mine if Aroclors are the actual source of contamination,
the following experiments have been planned.
a) Water solubility of Aroclor
b) Incineration of Aroclor containing paper
c) Analysis of air, water, and soil samples from around our manufacturing sites.
d) Feeding studies with pesticides that might be metab olized to polychlorinated biphenyls.
4. We have visited several government agencies In Washington
to-discuss polychlorinated biphenyls. Trips will be
planned as deemed necessary.
.
Industrial Hydraulic Fluids
,
MCS 790. a 190 SOS Pydraul 312 type fluid was formulated for the Japanese market. Properties are being obtained on this
fluid which Is similar in composition to Pydraul 135.
After typical physical properties and fire resistance are obtained, data and a small sample will be sent to Japan and pilot plant quantities blended for full scale pump tests.
Houghto-Safe 1120 - provided excellent anti-wear performance In a VlObC test In the same range as Pydraul 312 and anti wear petroleum oils.
HONS 035948
0 r(ff9 )
-33-
the fluoro chloro benzenes as replacements for TCB in dielectric fluids for polypropylene capacitors.
Functional Fluids - Europe
Ruabon research will explore potentials of silicate esters as new dielectric fluids and of thin polyethylene film for capacitors.
Dielectric Fluids
Technical service requests for compatibility of materials with Aroclor have been completed for BXL and Dlmltrava, Poland.
Compatibility tests with Pyroclor have been completed for Yorkshire Transformers. A used sample of Pyroclor has been tested for Civic Centre, Birmingham.
Vlsts have been'made t,o ICAR (Spain), Zanussi (Italy) and Blanchl (Italy) to Introduce MCS 748 (Aroclor 1242 plus Scavenger). This has also been Introduced to Erie Electron ic Components during a visit to Ruabon. Interest In this product has been limited so far due to our Inability to provide know-how on Its use.
At a meeting of BSI Committee ELE/20/2, little progress was made as I.E.C. documents were not ready, but an announce ment that the scope of this body Is being extended Is welcome for Monsanto, since It should help to extend the acceptance of Pyroclor transformers.
During a visit to St. Louis agreement was reached with FluldB Group that Research at Ruabon should Investigate alllcate esters as potential dielectric fluids and explore the potential of thin polyethylene film In capacitors. Visits were also made to South Second Street to discuss dielectric measurements and to E.O.K. Plant to look at Porocel refining and ln-llne dielectric cell operation.
V. Aroclor Wildlife
An analysis of the analytical work which will be necessary for the Arodor-Wlldlife project has been carried out. In cluded were a time table for all future activities with priorities. A formal P.A. Is being written In which this Information will be incorporated.
HONS 035949
o0 -34-
A portion of the Biotest-Aroclor feeding Btudy has been
started. Several chickens are being fed Aroclor 1242, 1254,
1260, and 5460, along with two chlorinated naphthalenes
(Halowax 1014, 1099) and two insecticides (Toxaphene ft
Tech. DDT). Tissue samples from these chickens are to be
analyzed for chlorinated hydrocarbons by electron capture
gas chromatography. In preparation for the arrival of the
tissue samples, procedures for the Isolation of the chlori
nated hydrocarbons have been outlined and are presently
being verified.
ED/OC analysis of tap water equilibrated with Aroclor 1242, 1248, and 1254 indicates that the solubility of Aroclor 1242 is approximately 200 parts per billion and that a
stable, reproducible emulsion can be formed which contains about twice as much Aroclor. When this study is completed a more detailed memo will be issued.
Aroclor analysis of sediment samples taken from Snow Creek
are also in the process of being completed. One sediment sample from the plant out-fall contained 0.25# Aroclor.
VI. Tractant Fluids
Lycoming Constant Speed Drive Test
We are investigating used MCS 757 from a constant speed drive test run at Lycoming. Traction results were excellent during the early part of the test. However, when the input speed reached about 6000 rpm, the oil pressure dropped,
oil temperature -increased sharply, and the test had to be
stopped.
Comparison of the used fluid-with new MCS 757 shows that the fluid is relatively unchanged:
Viscosity -20
100 *F 210 F
'
New
17,968 22.2 3.68
Used
16,171 24.0 3.82
Acid No.
.01 .02
VPC
Appearance
Dlcyclohexyl: Hydrogenated Dlcumyl 1:6.4
Unchanged 1:6.9
HONS
The used fluid was turbid. Centrifugation produced a small amount of metallic deposit, presumed to be wear debris.