Document RayVNMpn2YvwLp5mZjaR28ML8

1 1 (Sip tsuKtimo mot E. I. du Pont de Nemours 5 Company IMeOKRMATCD Wilmington. Delaware i9898 TEXTILE FIBEHS-OEPAKTMENT RECEIVED 4b ee: X. C. Hoolard - Old Hlekary C. t>. Crook - Old Hickory L J. F. Morgan - Haskell Lab. L. Cat - PLAINTIFF'S : EXHIBIT f :.DttP-297 August *1, 1961 >. J. TKACH out HCBORT isDy a.;K:LL LASCRATOkY ASBESTOS WJBT AMAUBIB ft Xa nid-1968 we followed Construction Division's lied in adoption as asbestos duat Level foal of 0.9 million partlclea percubic fact (MPPCF). The recognised TLV u than $.0 (Kef. l) baaed on an laplager collection, lightfield count technique. He also adopted Constraction'a proposed netbod of laibrane filter sample collection and phase light microscopic analysis as this is sore accurate than the impinger/llght-field technique. Our 0.5 KPFCF goal is only for the aanll aabestoa partlclea (leas than $ nierona in length) aa the recognised Haakel Ieb and Construction Safety experts all a*intain that the respiratory ay*ten of the buaan body can filter out those larger sited particles. In late 1968 the Ancrlcan Conference of Govcronentel Industrial Hygeaiste published an latent to lower the aabestoa TLV to 2 HPPCF (impinger/light-field count) oi- 12 fibers per mlllilcter, greater than 5 p (neftbrane filter, phase light microscopic count). (Kef. 2). from Kef. 3, 2 seduce that the XLV for the enbrane filter netbod excludes the analler particles to more equate these results with the lapinger nethod as the impinger collection efficiency for snail pbi-ticlcc is low. I assume it is Xroo the I96& 'ILY intended change that Old Hickory decided to neasure only the large asbestos dust particles (>5p) with a goal of 12 pwrticles/ML. howevex, since the problem area is defined today as the snail particles (<- 5p), I suggest that you have a total particle count nade (i.e. 0-5, 5-10,>- lDp, total asbestos fiber count, and total count for all dust). Also, while the conversion frsn HI to cubic feet can be readily nade, X think it best if you would use the MFFCF units so that your results directly eonpare with cur established goal and results fron Coostruetion Division and other Textile Fibers plants. Dr. Corn, Univ. of Pittsburgh, can provide a dust count per the abort else ranges in the KFPCF units - as he now does this for our other plants. NAMUFACTUKIXG DIVISION J. A. Signer Division engineer by `*7/0*- --- ,,/ BCD:he* D. D. financed hef.l Threshold Limit Values - 1367 Anerioae Conference of Omn ii nt Industrial fiygenlats. Kef.2 threshold Limit Values 1968 American Conference of govern*nt Industrial fiygenist*. Kef. 3 Measurement of Asbestos Exposure by tynch and Ayer from Journal of Occupational Medicine, 1/68. * DUP better Things FOR better LIVING . through chemists 1142231