Document RaxJqXaarXY0DMzErVpRm6057
plaintiffs exhibit
ANSI A21.6-1975 (AWWA C106-75)
Revision of A21.6-1970 (AWWA C106-70)
AMERICAN NATIONAL STANDARD
lot
CAST-IRON PIPE CENTRIFUGALLY CAST IN METAL MOLDS,
FOR WATER OR OTHER LIQUIDS
Administrative Secretariat
AMERICAN WATER WORKS ASSOCIATION Co-Secretariats
AMERICAN GAS ASSOCIATION NEW ENGLAND WATER WORKS ASSOCIATION
Raised edition approved by American Rational Standards Institute. Inc., May 28, 1975.
PUBLISHED BY
AMERICAN WATER WORKS ASSOCIATION
6666 West Quincy Avenue, Denver, Colo. 80235
CTD000401
Table of Contents
SEC.
Foreword
I History of Standard. II Acceptance Tests......... III Options .
PAGE
iii iv v
Standard
6-1 Scope........
...
6-2 Definitions.......................
6-3 General Requirements.................
6-4 Inspection and Certification by
Manufacturer........................
6-5 Inspection by Purchaser...............
6-6 Delivery and Acceptance..............
6-7 Tolerances or Permitted Variations.
6-8 Coatings and Linings.....................
6-9 Hydrostatic Test..............................
6-10 Marking Pipe....................................
6-11 Weighing Pipe..............................
6-12 Acceptance Tests.............................
6-13 Ring Tests and Full-Length Burst
ing Tests........................................
6-14 Chemical Analyses.......................
6-15 Foundry Records.....................
6-16 Additional Tests Required by Pur
chaser .............
1 1 I
2 2 2 2 3 3 3 3 3
5 6 6
7
SEC.
PAGEI!
6-17 Defective Specimens and Retests.. 6-18 Rejection of Pipe.............................
6-19 Determining Rejection.................... 7
Tables
Table 6.1--Selection Fable for Push-On
Joint Cast-Iron Pipe......................
8
Table 6.2--Selection Table for Mechanical-
Joint Cast-Iron Pipe.............................. 10
Table 6.3--Standard Thickness Selection
Table for Cast-Iron Pipe...................... 12
Table 6.4--Standard Dimensions and Weights
of Push-On Joint Cast-Iron Pipe. .
14
Table 6.5--Standard Dimensions and Weights
of Mechanical-Joint Cast-Iron Pipe.... 16
Table 6.6--Standard Bell-and-Spigot Joint
Dimensions.............................................. 18
Figures
Fig. 6.1 Position From Which Talbot Strip
is Cut........................................................ 4
Fig. 6.2 Location of Rockwell Hardness Tests
on Talbot Strip Specimen.................... 5
Fig. 6.3 Assembly for Ring Test ....
5
American National Standard
An American National Standard implies a consensus of those substantially concerned with its scope and provisions. An American National Standard is intended as a guide to aid the manufacturer, the consumer, and the general public. The existence of an American National Standard does not in any respect preclude anyone, whether he has approved the standard or not, from manufacturing, marketing, purchasing, or using products, processes, or procedures not conforming to the standard. American National Standards are subject to periodic review, and users are cautioned to obtain the latest editions. Producers of goods made in conformity with an American National Standard are encouraged to state on their own responsibility in advertising, promotion material, or on tags or labels that the goods are produced in conformity with particular American National Standards.
CAUTION NOTICE. This American National Standard may be revised or with drawn at any time. The procedures of the American National Standards Institute require that action be taken to reaffirm, revise, or withdraw this standard no later than five (5) years from the date of publication. Purchasers of American National Standards may receive current information on all standards by calling or writing the American National Standards Institute, 1430 Broadway, New York, N. \. 10018, (212) 868-1220.
C Copyright 1975 by the American Water Works Assn, Printed in US
ii
CTD000402
Foreword
This foreword is provided for information only and is not a part of ANSI A21.6-1975 (A WWA C106-75).
I--History of Standard
On Sep. 10, 1902, NEWWA adopted a "Standard Specification for CastIron Pipe and Special Castings," covering bell-and-spigot pit-cast pipe and fittings of ten thickness classes. The thickness classes were based on allowable internal pressures varying by increments of 50 ft of head.
On May 12, 1908, AWWA adopted a "Standard Specification for CastIron Pipe and Special Castings," covering bell-and-spigot pit-cast pipe and fittings of eight classes, A through
6T: , with allowable working pressures
arying by increments of 100 ft of head from 100 to 800 ft. Dimensions and weights were given for pipe and fittings.
In 1926, ASA Sectional Committee k(now American National Standards
ommittee) A21 on Cast-Iron Pipe and Fittings was organized under the sponsorship of A.G.A., ASTM, AWWA, and NEWWA and was as signed the following scope:
Unification of specifications for castiron pipe, including materials; dimen sions; pressure ratings; methods of manufacture (including such new de\ elopments as centrifugal casting) insofar as they may be necessary to secure satis factory specifications; elimination of un necessary sizes and varieties; consideratio i of the possibility of developing a coirdinated scheme of metallic pipe and fittings applicable to all common mediums; and methods of making up joints
k
isofar as they are determining as to the limensional design of cast-iron pipe.
The types of ca>t-iron pipe [are] to include bell-and-spigot pipe, flanged pipe, flanged and bell mouth fittings and wall castings, pipe elbows, tees, wyes, return bends, and other fittings not now included in standard lists; cast-iron pipe threaded for flanges or couplings. The standardization is not to include methods of installing pipe and similar matters, except as to the making up of joints in its relationship to the dimensional stan dardization of pipe and fittings, as noted above.
Sectional Committee A21 spon sored many tests of pipe and fittings; these included subjection of pipe to combined earth load and internal pressures (which form the basis of pipe thickness design), corrosion tests, measurement of hydraulic friction loss in fittings, and tests of bursting strengths of pipe and fittings. After exhaustive study of the test results and other research, the committee in 1939 issued A21.1, "American Stan dard Practice Manual for the Comp utation of Strength and Thickness of Cast Iron Pipe." The manual included nomograms and thickness tables for pit-cast pipe with 11/31 * iron strength. As stated in the preface to that manual, however, the design method was applicable to pipe of any iron strength.
Discussions and interpretations of the method of design of cast-iron pipe
* The first figure designates the bursting tensile strength in units of 1 000 psi and the second figure designates the ring modulus of rupture in units of 1 000 psi.
in
CTD000403
were published in 1939 and presented to AWWA and A.G.A. As a result of these publications and because of the general acceptance of A21.1, a substantial volume of cast-iron pipe was designed by the new method and furnished to manufacturers' standards between 1939 and 1953. A standard (A21.2) for pit-cast pipe with 11/31 iron strength also was issued in 1939. Work on standards for centrifugally cast pipe with 18/40 iron strength was started after the design was completed in 1939, but, owing to the intervention of World War II and other causes, they were not formally issued until 1953.
In 1957, a revision of A21.1 was issued. In that revision, designated ASA A21.1-1957 (AWWA Hl-57) the major change was the addition of a method for computing earth loads on pipe laid under embankments and of nomograms and thickness tables for centrifugally cast pipe with 18/40 iron strength.
In 1958, Sectional Committee A21 was reorganized. Subcommittees were established to study each group of standards in accordance with the review and revision policy of ASA (now ANSI). The subcommitteee on pipe (Subcommittee No. 1) was or ganized with the following assignment:
The scope of the committee actitivy shall include an examination of all pres ent A21 standards for pipe to determine what is needed to bring these up to date. The examination shall include A21.1, A21.2, A21.3, A21.6, A21.7, A21.8, and A21.9, as well as any other matters per taining to pipe >tandards.
As a result of the work of Subcom mittee No. 1 on this assignment, re visions of the cast-iron pipe standards Ail.6(AWWA 006), A21.7, A21.8 (AWWA 008) and A21.9 were issued in 1962. A revision of A21.1-1957 f AWAY'A Hl-571 was issued in 1967
and reaffirmed without revision in
1972. Revisions of the 1962 cast-iron pipe standards were issued in 197I
The major revisions of A21.6-197;
were: pipe with push-on joints we
added; laying conditions C and D
were deleted and condition F was
added; and, the tables were revised to
include the pipe lengths then being
produced.
In 1974, Subcommittee 1 reviewed
the 1970 edition and recommended
minor editorial changes. Therefore,
this edition is unchanged from the
1970 edition except for minor editorial
changes and the updating of this fore
word.
-. ... .
The tables and strength test re
quirements in this standard are for
pipe with 18/40 iron strength. Ad
vances in production technology have
enabled the manufacturers to furnish
pipe with greater strength. Pipe
with 21/45 iron strength has been
furnished for many years. Design
details and standard thicknesses fo
pipe with 21/45 iron strength are'
shown in A21.1-1957 (AWWA C101
67), reaffirmed in 1972.
II--Acceptance Tests
Acceptance tests were established^
as routine control measures to ensure the design burst and ring strengths. The acceptance tests specified in this standard are the Talbot strip test and the hardness test. In establishing the acceptance values for the Talbot strip test, A21 Committee in the 1940s re viewed detailed data, including burst, ring, and Talbot strip tests on more than 400 pipe centrifugally cast in metal molds. Correlations of the data showed that the Talbot strip modulus of rupture and secant modu lus of elasticity values specified in this standard represent acceptable pipe which meet the design burst and rin|A strengths.
IV
CTD000404
The hardness test was specified as a means of assuring the ferritic matrix which is characteristic of the micro structure of pipe cast in metal Vnolds.
The specified acceptance values for the Talbot strip test provide addi tional control of the microstructure to ensure satisfactory machinability.
Ill--Options
This standard includes certain options which, if desired, must be specified in the invitation for bids and on the purchase order. Also, a num ber of items must be specified to de scribe completely the pipe required. The following summarizes these de' tails and available options and lists the sections of the standard where they can be found:
1. Size, joint type, thickness or class, and laying lengths (Tables)
2. Special joints (Sec. 6-1) 3. Certification by manufacturer
(Sec. 6-4) 4. Inspection by purchaser (Sec.
6-5) 5. Cement lining (Sec. 6-8.2) Ex
perience has indicated that bi tuminous inside coating is not complete protection against loss in pipe capacity caused by tuberculation. Cement linings are recommended for most waters. 6. Special coatings and linings (Sec. 6--8.4) 7. Special marking on pipe (Sec. 6-10) 8. Written transcripts of foundry records (Sec. 6-15) 9 Special tests (Sec 6-16).
CTD000405
Committee Personnel
Subcommittee 1, Pipe, which reviewed this standard, had the following per sonnel at that time:
Edward C. Sears, Chairman Walter Amory, Vice-Chairman
User Members
Robert S. Bryant
Frank E. Dolson
George F. Keenan Leonard Orlando Jr. fohn E. Perry
Producer Members
W. D. Goode Carl A. Henrikson Thomas D. Holmes Sidney P. Teague
Standards Committee A21, Cast-Iron Pipe and Fittings, which reviewed and approved this standard, had the following personnel at the time of approval:
Lloyd W. Weller, Chairman Carl A. Henrikson, Vice-Chairman James B. Ramsey, Secretary
Organization Represented American Gas Association American Society of Civil Engineers American Society of Mechanical Engineers American Society for Testing and Materials American Water Works Association
Cast Iron Pipe Research Association
Individual Producer Manufacturers' Standardization Society of
the Valve and Fittings Industry New England Water Works Association Naval Facilities Engineering Command Underwriters' Laboratories, Inc. Canadian Standards Association
* Liaison representative without vole
Name of Representative
Leonard Orlando Jr. Kenneth W. Henderson James S. Vaxick Albert H. Smith Jr.
Arnold M. Tinkey
Lloyd W. Weller Carl A. Henrikson Edward C. Sears W. Harry Smith Alfred F. Case Abraham Fenster
Walter Amory
C.Stanley
Baker
E.John
Perry
F.W.
Semenciiuk*
CTD000406
ANSI A21.6-1975 IAWWA Cl06-75)
Revision of A21.6-1970 (AWWA C106-70)
American National Standard for
Cast-Iron Pipe Centrifugally Cast in Metal Molds, for Water or Other Liquids
Sec. 6-1--Scope
This standard covers 3-in. through 24-in. cast-iron pipe centrifugally cast in metal molds for water or other liquids. Characteristics of such pipe with push-on joints, mechanical joints and bell-and-spigot joints are given in the tables. This standard may be used for pipe with such other types of joints as may be agreed upon at the time of purchase. The thicknesses, weights, and strength test require ments shown in this standard are for pipe with 18/40 iron strength (18 000 psi minimum bursting tensile and 40 000 psi minimum ring modulus of rupture).
6-2.4. Cast iron. The unqualified term cast iron shall apply to gray cast iron which is a cast ferrous material in which a major part of the carbon con tent occurs as free carbon in the form of flakes interspersed through the metal.
6-2.5. Push-on joint. The single rubber-gasket joint as described in ANSI A21.ll (AWWA Clll) of latest revision.
6--2.6. Mechanical joint. The gas keted and bolted joint as detailed in ANSI A2l.ll (AWWA Clll) of latest revision.
6-2.7. Bell-and-spigot joint. The poured or caulked joint as detailed in Table 6.6.
Sec. 6-2--Definitions
Sec. 6-3--General Requirements
Under this standard, the following definitions shall apply:
6-2.1. Purchaser. The party enter ing into a contract or agreement to purchase pipe according to this standard.
6-2.2 Manufacturer. The party that produces the pipe.
6-2.3. Inspector. The representa tive of the purchaser, authorized to inspect in behalf of the purchaser to determine whether or not the pipe meet this standard.
6-3.1. Pipe with push-on joints, mechanical joints, and bell-and-spigot joints shall conform to the applicable dimensions and weights shown in the tables in this standard and to the ap plicable requirements of ANSI A21.ll (AWWA Clll) of latest revision. Pipe with other types of joints shall comply with the joint dimensions and weights agreed upon at the time of purchase, but in all other respects shall fulfill the requirements of this standard.
CTD000407
) AMERICAN NATIONAL STANDARD
6-3.2. The nominal laying length of the pipe shall be as shown in the tables. A maximum of 10 per cent of the total number of pipe of each size specified in an order may be furnished by as much as 24 in. shorter than the nominal laying length, and an addi tional 10 per cent may be furnished by as much as 3 in. shorter than nominal laying length.
Sec. 6-4--Inspection and Certifica tion by Manufacturer
6-4.1. The manufacturer shall es tablish the necessary quality control and inspection practice to assure com pliance with this standard.
6-4.2. The manufacturer shall, if required on the purchase order, furnish a sworn statement that the inspection and all of the specified tests have been made and the results thereof comply with the requirements of this stan dard.
6-4.3. All pipe shall be clean and sound without defects which will im pair their service. Repairing of de fects by welding or other method shall not be allowed if such repairs will ad versely affect the serviceability of the pipe or its capability to meet strength requirements of this standard.
Sec. 6-5--Inspection by Purchaser
manufacturer shall provide the in spector with assistance as necessary for the handling of pipe.
Sec. 6-6--Delivery and Acceptance
All pipe and accessories shall com ply with this standard. Pipe and ac cessories not complying with this standard shall be replaced by the man ufacturer at the agreed point of de livery. The manufacturer shall not be liable for shortages or damaged pipe after acceptance at the agreed point of delivery except as recorded on the delivery receipt or similar document by the carrier's agent.
Sec. 6-7--Tolerances or Permitted Variations
6-7.1. Dimensions. The spigot end, bell, and socket of the pipe and the ac cessories shall be gaged with suitable gages at sufficiently frequent intervals to ensure that the dimensions comply with the requirements of this stan dard. The smallest inside diameter of the sockets and the outside of the spigot ends shall be tested with cir cular gages. Other socket dimensions shall be gaged as appropriate.
6-7.2. Thickness. Minus thickness tolerances of pipe and bell shall not exceed those shown below:
6-5.1. If the purchaser desires to inspect pipe at the manufacturer's plant, the purchaser shall so specify on the purchase order, stating the condi tions (such as time, and the extent of inspection) under which the inspection shall be made.
6-5.2. The inspector shall have free access to those parts of the manu facturer's plant that are necessary to assure compliance with this standard.
The manufacturer shall make avail able for the inspector's use such gages as are necessary for inspection. The
Pipe Size m.
3-8 10-12 14-24
Minus Tolerance in.
0.05 0.06 0.08
Note : An additional tolerance of 0.02 in. shall be permitted over areas not exceeding 8 in. in any direction.
6-7.3. Weight. The weight of any single pipe shall not be less than the tabulated weight by more than 5 per
cent for pipe 12 in. or smaller in diam eter, nor by more than 4 per cent for pipe larger than 12 in. in diameter
CTD000408
PIPE CENTRIFUGALLY CAST IN METAL MOLDS
3
Sec. 6-8--Coatings and Linings
6-8.1. Outside coating. The outside coating for use under normal condi tions shall be a bituminous coating approximately 1 mil thick. The coat ing shall be applied to the outside of all pipe, unless otherwise specified. The finished coating shall be continu ous, smooth, neither brittle when cold nor sticky when exposed to the sun and shall be strongly adherent to the pipe.
6-8.2. Cement-mortar linings. Ce ment linings shall be in accordance with ANSI A21.4 (AWWA C104) of latest revision. If desired, cement lin ings shall be specified in the invitation for bids and on the purchase order.
6-8.3. Inside coating. Unless other wise specified, the inside coating for pipe not cement lined shall be a bitu minous material as thick as practi cable (at least 1 mil) and conforming to all appropriate requirements for seal coat in ANSI A21.4 of latest revision.
6-8.4. Special coatings and linings. For special conditions, other types of coatings and linings may be available. Such special coatings and linings shall be specified in the invitation for bids and on the purchase order.
Sec. 6-9--Hydrostatic Test
Each pipe shall be subjected to a hydrostatic test of not less than 500 psi. This test may be made either be fore or after the outside coating and the inside coating have been applied, but shall be made before the applica tion of cement lining or of a special lining.
The pipe shall be under the full test pressure for at least 10 s. Suitable controls and recording devices shall be provided so that the test pressure and duration may be adequately ascer tained. Any pipe that leaks or does
not withstand the test pressure shall be rejected.
In addition to the hydrostatic test before application of a cement lining or special lining, the pipe may be re tested, at the manufacturer's option, after application of such lining.
Sec. 6-10--Marking Pipe
The weight, class or nominal thick ness, and sampling period shall be shown on each pipe. The manufac turer's mark and the year in which the pipe was produced shall be cast or stamped on the pipe. When specified on the purchase order, initials not ex ceeding four in number shall be cast or stamped on the pipe. All required markings shall be clear and legible and all cast marks shall be on or near the bell. All letters and numerals on pipe sizes 8 in. and larger shall be not less than ^ in. in height.
Sec. 6-11--Weighing Pipe
Each pipe shall be weighed before the application of any lining or coat ing other than the bituminous coating and the weight shall be shown on the outside or inside of the bell or spigot end.
Sec. 6-12--Acceptance Tests
The standard acceptance tests for the physical characteristics of the pipe shall be as follows:
6-12.1. Talbot strip tests. Talbot strip tests shall be used to determine the acceptability of 3-24 in. pipe for modulus of rupture and secant modu lus of elasticity.
6-12.1.1. Sampling. At least one sample shall be taken during each period `of approximately 3 hr. The sample for the first period shall be taken during the first hour, or if cast ing is direct from the melting unit, from the first ladle. Samples shall be
CTD000409
4 AMERICAN NATIONAL sTANUakC
taken so that each size of pipe continously cast for 2 hr or longer and each source of iron continuously used for 2 hr or longer shall be fairly repre sented.
6-12.1.2. Acceptance values. The modulus of rupture as determined by the Talbot strip test shall be 40 000 psi minimum.
The secant modulus of elasticity value shall not exceed 300 times the actual value of the modulus of rupture. (For example: when the modulus of rupture is 40 000 psi, the secant modu lus of elasticity shall not exceed 12 000 000 psi.)
6-12.1.3. Test method. Talbot strips (Fig. 6.1) shall be machined
Fig. 6.1. Position From Which Talbot Strip is Cut
longitudinally from each pipe speci men selected for testing by this method. The Talbot strips may be cut from a part of the ring little stressed in the ring test--that is, near one of the elements marked a in the illustration of the ring test (Fig. 6.3). The strips in any case shall be in cross section as indicated in Fig. 6.1--that is, shall have for their width the thick ness of the pipe and for their depth 0.50 in. Their length shall be at least 10j in. The strips shall be tested as beams on supports 10 in. apart with loads applied perpendicularly to the machined faces at two points 35 in. from the supports. The breaking load and the deflection shall be observed and recorded.
The strip shall be accurately cali pered at the point of rupture and the modulus of rupture, R, shall be calcu lated by the usual beam formula,
which for this case reduces to the expression
10W R = td2
The secant modulus of elasticity, E,, in pounds per square inch, shall be computed by the formula
21.3/? E, = -dry-
In the above formulas, R is the modu lus of rupture (psi); E,, the secant modulus of elasticity (psi); W, the breaking load (lb); d, the depth (in.) of the strip (intended to be 0.50 in.); t, the width (in.) of the strip (pipe thickness); and y, the deflection (in.) of the strip at the center at breaking load.
Deflection measurements shall be that of the specimen and shall not in clude any compression of the supports or loading blocks, or backlash or dis tortion of the testing machine.
6-12.2. Hardness tests. Hardness tests shall be made on the outside sur face of pipe. A sufficient number of pipe shall be tested to assure that the hardness does not exceed Rockwell B-95, or its equivalent. Pipe may be heat-treated to meet this requirement.
For the purpose of foundry records, hardness tests shall be made on a specimen from each Talbot strip se lected for testing in Sec. 6-12.11. Rockwell B hardness determinations shall be made in accordance with ASTM El8-67 on the following sur faces at their approximate centers: (a), the outside pipe surface, (b) the inside pipe surface, and (c) either of the two cut surfaces. These three determina tions shall be made at three locations (1-2-3) along the length of the speci men, as shown in Fig. 6.2. The three determinations for each surface shall be averaged and no average value shall exceed Rockwell B-95. No single
CTD000410
Fll'li CIN rKlt'UCALLY CAS l' IN MCTAI. MUl.Us
0
Pig. 6.2. Location of Rockwell Hardness Tests on Talbot Strip Specimen
each strip and ring and the modulus of elasticity and hardness of each strip.
6-13.2. Ring test method. The maximum length of any ring shall not exceed 12 in.; for pipe 14 in. and larger, the minimum length shall be 10 in.; for pipe 12 in. and smaller, the minimum length shall be one half the nominal diameter of the pipe. Each ring shall be tested by the threeedge bearing method as indicated in Fig. 6.3. The lower bearing for the
determination on the Talbot strip shall exceed B-98.
Sec. 6-13--Ring Tests and FullLength Bursting Tests
6-13.1. The manufacturer shall make bursting tests and ring tests in conjunction with strip tests so that he can certify the design values of the modulus of rupture (40 000 psi) and the bursting tensile strength of the iron in the pipe (18 000 psi). These tests shall be made in accordance with dimensions and methods given in Sec.
9 6-13.2 and Sec. 6-13.3. At least one pipe sample for the ring and burst ing tests shall be selected from each of the following size groups from each calendar month's cast:
Group
1
Size in.
6. 8
10, 12
14, 16, 18 20, 24
When no pipe in a size group are manufactured during the calendar month, no tests on these sizes are required. Ring tests and bursting
tests are not required on 3- and 4-in. pipe. At least three Talbot strips \ shall be tested from each pipe selected for bursting. Tests and records shall include the modulus of rupture of
Fig. 6.3. Assembly for Ring Test
ring shall consist of two strips with vertical sides having their interior top edges rounded to a radius of approxi mately % in. The strips shall be of hard wood or metal. If of metal, a piece of fabric or leather approximately 2^ in. thick shall be laid over them. They shall be straight and shall be securely fastened to a rigid block, with their interior vertical faces the following distances apart:
Pipe Size in.
6-12 14-24
Bearing Strip Spacing
in.
4 1
The upper bearing shall be a hard wood block, straight and true from end to end. The upper and lower bearings shall extend the full length of the ring. The ring shall be placed symmetrically between the two bearings, and the center of application of the load shall
CTD000411
6 AMERICAN NATIONAL STANDARD
be so placed that the vertical deforma tion at the two ends of the ring shall be approximately equal. If the ring is not uniform in thickness, it shall be so placed that the thick and thin por tions are near the ends of the hori zontal diameter.
For purposes of Sec. 6-15, a record of the breaking load of each ring tested shall be made. The modulus of rup ture is computed from the formula
W(d + t) R = 0.954 bt2
in which R is the modulus of rupture (psi); W, the breaking load (lb); d, the average inside diameter (in.) of the ring; t, the average thickness (in.) of metal along the line of frac ture; and b, the length (in.) of the ring.
6-13.3. Burst test method. The bursting tensile strength shall be de termined by testing full-length pipe (less the amount cut off for ring and strip test specimens) to destruction by hydraulic pressure. Bells may be removed to facilitate testing. A suitable means for holding the end thrust shall be used which will not subject the pipe to endwise tension or compression, or other parasitic stresses. A calibrated pressure gage shall be used for determining the bursting pressure. The gage shall be connected to the interior of the test pipe by a separate connection from that which supplies water for the test. The unit tensile strength in bursting shall be obtained by the use of the formula
in which 5 is the bursting tensile strength (psi) of the iron; P, the in ternal pressure (psi) at bursting; d, the average inside diameter (in.) of the pipe; and t, the minimum average
thickness (in.) of the pipe along the principal line of break.
Measurements of thickness shall be taken along the principal line of break at 1-ft intervals.
The minimum average thickness along the principal line of break shall be obtained by averaging the measure ments at the thinnest section at a weight of two and at the adjacent sec tions on each side at a weight of one each; or, if the thinnest section is at the end of the break, by averaging the thinnest-section measurement at a weight of two and the measurements of the adjacent section and the next section at a weight of one each.
Sec. 6-14--Chemical Analyses
Analyses of the iron shall be made at sufficiently frequent intervals to determine compliance with the fol lowing limits:
Substance
Maximum Limit per cent
Phosphorus Sulfur
0.90 0.12
Control of the other chemical con stituents shall be maintained to meet the physical property requirements of this standard. Samples for chemical analyses shall be representative and shall be obtained from either accept ance test specimens or specimens cast for this purpose.
Sec. 6-15--Foundry Records
The results of the following tests shall be recorded and retained for one year and shall be available to the pur chaser at the foundry. Written trans scripts of the results of these tests shall be furnished when specified on the pur chase order:
6-15.1. 6-15.2.
Talbot strip tests (see Sec. 6-12.1)
Hardness tests (see Sec. 6-12.2)
CTD000412
PIPE CEN'TRIFUGALLY CAST IN METAL MOLDS
7
6-15.3. 6-15.4.
Ring tests and full-length bursting tests (see Sec.
6-13) Chemical analyses (see Sec.
6-14).
mens shall meet the prescribed tests to qualify the pipe produced in that sampling period.
Sec. 6-18--Rejection of Pipe
Sec. 6-16--Additional Tests Re quired by Purchaser
When tests other than those pro vided in this standard are required by the purchaser, such tests shall be speci fied in the invitation for bids and on the purchase order.
When any routine chemical analysis fails to meet the requirements of Sec. 6-14 or when any physical acceptance test fails to meet the requirements of Sec. 6-12.1, 6-12.2, or 6--17, the pipe cast in the same sampling period shall be rejected except as subject to the provision of Sec. 6-19.
Sec. 6-17--Defective Specimens and Retests
When any physical test specimen shows defective machining or lack of continuity of metal, it shall be dis carded and replaced by another speci men. When any sound test specimen fails to meet the specified require ments, the pipe from which it was taken shall be rejected and a retest may be made on two additional sound specimens from pipe cast in the same sampling period as the specimen which failed. Both of the additional speci
Sec. 6-19--Determining Rejection
The manufacturer may determine the amount of rejection by making similar additional tests of pipe of the same size as that rejected until the rejected lot is bracketed in order of manufacture by an acceptable test at each end of the interval in question. When pipe of one size is rejected from a sampling period, the acceptability of pipe of different sizes from that same period may be established by making the routine acceptance tests for these sizes.
CTD000413
8 AMERICAN NATIONAL STANDARD
TABLE 6.1
Selection Table for Push-On Joint Cast-Iron Pipe\
These thicknesses and weights are for pipe laid without blocks, on flat-bottom trench, with tamped backfill (lay
iCngIOcIo).ndition B), under S ft of cover. For other conditions see tables 6.3 and 6.4 hereof and ANSI A21.1 (AWWA
Size Thickness OD
Weight Based on 18-ft Laying Length
Weight Based on 20-ft Laying Length
Per Lengthf Avg. per Footf Per Lengthf Avg. per Foott
in. lb
Working Pressure 50 psl--115 ft Head
3* 0.32 3.96 215 12.0 240 11.9
4 0.35 4.80 290 16.1 320 16.0
6
0.38
6.90
460 25.6
510 25.6
8 0.41 9.05 665 36.9 735 36.8
10
0.44
11.10
880 49.0
975 48.7
12
0.48
13.20
1.140
63.4 1,260
63.1
14
0.48
15.30
1.335
74.1 t,470
73.6
16
0.54
17.40
1.700
94.5 1,880
94.0
18
0.54
19.50
1.920
106.7
2,120
106.1
20
0.57
21.60
2.250
124.9
2.485
124.2
24
0.63
25.80
2,975
165.3
3.285
164.4
Working Pressure 100 psl-- 231 ft Head
3* 0.32
3.96 215 12.0
240
4 0.35 4,80 290 16.1 320
6 0.38 6.90 460 25.6 510
8 0.41 9.05 665 36.9 735
10
0.44
11.10
880 49.0
975
12
0.48
13.20
1.140
63.4 1,260
II.9 16.0
25.6 36.8 48.7
63.1
14
0.51
15.30
1.410
78.2 1,555
77.8
16
0.54
17.40
1.700
94.5 1.880
94.0
18
0.58
19.50
2,050
113.9
2.265
113.3
20
0.62
21.60
2.430
134.9
2,685
134.2
24
0.68
25.80
3.190
177.3
3,525
176.4
Working Pressure 150 psl--346 ft Head
3 0.32 3.96 215 12.0 240 11.9
4 0.35 4.80 290 16.1 320 16.0
6
0.38
6.90
460 25.6
510 25.6
8 0.41 9.05 665 36.9 735 36.8
10 0.44 11.10 880 49.0 975 48.7
12
0.48
13.20
1,140
63.4 1,260
63.1
14
0.51
15.30
1.410
78.2 1,555
77.8
16
0.54
17.40
1,700
94.5 1,880
94.0
18
0.58
19.50
2,050
113.9
2,265
113.3
20
0.62
21.60
2,430
134.9
2.685
134.2
24
0.73
25.80
3,410
189.4
3,765
188.4
Working Pressure 200 psi--162 ft Head
3* 0.32
3.96 215 12.0
240
4
0.35
4.80
290 16.1
320
6
0.38
6.90
460 25.6
510
3 0.41 9.05 665 36.9 735
10
0.44
11.10
880 49.0
975
12
0.48
13.20
1,140
63.4
1,260
11.9
16.0 25.6 36.8 48.7 63.1
14
0.55
15.30
1,510
83.8
1.670
83.4
16
0.58
17.40
1,815
100.9
2.010
100.4
18
0.63
19.50
2,210
122.8
2,445
122.2
20
0.67
21.60
2,610
144.9
2.885
144.2
24
0.79
25.80
3.665
203.6
4,055
202.6
* Pipe of 3-In. size also available In 12-ft laying length. Weight per lengthf Is 150 lb; average weight per foot! Is 12.5 lb for all working pressures and heads.
t Including bell. Calculated weight of pipe rounded off to nearest 5 ib. 2 Including bell. Average weight per foot based on calculated weight of pipe before rounding. } Weights shown for push-on joint pipe are also applicable to bell-and-spigot joint pipe.
CTD000414
PIPfc CENTRIKUGALLY CAST IN METAL MOLDS
9
TABLE 6.1--(contd.)
Selection Table for Push-On Joint Cast-Iron Pipe\
These thicknesses .and weights are for pipe laid without blocks, on flat-bottom trench, with tamped backfill (Laying Condition B), under 5 ft of cover. For other conditions see Tables 6.3 and 6.4 hereof and ANSI A21.1 (AWWA C101).
Size Thickness OD
Weight Based on 18-ft Laying Length
Weight Based on 20-ft Laying Length
Per Lengthf Avg. per Foot! Per Lengthf Avg. per Footf
in* lb
Working Pressure 250 psi---577 ft Head
3* 0.32 3.96 215 12.0 240 11.9
4
0.35 4.80 290 16.1
320 16.0
6
0.38
6.90
460 25.6
510 25.6
8 0.41 9.05 665 36.9 735 36.8
10
0.44
11.10
880 49.0
975
48.7
12
0.52
13.20
1,230
68.3 1,360
67.9
14
0.59
15.30
1,610
89.5 1,780
89.0
16
0.63
17.40
1,960
109.0
2.170
108.4
18
0.68
19.50
2,370
131.8
2.620
131.1
20
0.72
21.60
2.785
154.8
3,080
154.0
24
0.79
25.80
3,665
203.6
4,055
202.6
Working Pressure 300 psl--693 ft Head
3* 0.32 3.96 215 12.0 240 11.9
4 0.35 4.80 290 16.1 320 16.0
6 0.38 6.90 460 25.6 510 25.6
8 0.41 9.05 665 36.9 735 36.8
10
0.48
11.10
955 53.0 1,055
52.7
12
0.52
13.20
1,230
68.3 1,360
67.9
14
0.59
15.30
1,610
89.5 1,780
89.0
16
0.68
17.40
2,100
116.8
2,325
116.2
18
0.73
19.50
2,530
140.6
2,800
140.0
20
0.78
21.60
3,000
166.6
3,315
165.8
24
0.85
25.80
3,920
217.8
4,335
216.8
Working Pressure 350 psl--808 ft Head
3* 0.32 3.96 215 12.0 240 11.9
4 0.35 4.80 290 16.1 320 16.0
6 0.38 6.90 460 25.6 510 25.6
8 0.41 9.05 665 36.9 735 36.8
10
0.52
11.10
1,025
56.9 1,130
56.6
12
0.56
13.20
1,315
73.1 1,455
72.7
14
0.64
15.30
1,735
96.3 1,920
95.9
16
0.68
17.40
2,100
116.8
2,325
116.2
18
0.79
19.50
2,720
151.2
3,0t0
150.6
20
0.84
21.60
3.210
178.4
3.550
177.6
24
0.92
25.80
4.220
234.4
4,665
233.4
* Pipe of 3-in. size also available in 12-ft laying length. Weight per lengthf is 150 lb; average weight per footj Is 12.5 lb for all working pressures and heads.
t Including bell. Calculated weight of pipe rounded off to nearest 5 lb. t Including bell. Average weight per foot based on calculated wieght of pipe before rounding,
j Weights shown for push-on joint pipe are also applicable to bell-and-spigot joint pipe.
CTD000415
to AMERICAN NATIONAL STANDARD
TABLE 6.2
Selection Table for Mechanical-Joint Cast-Iron Pipe
These thicknesses and weights are for pipe laid without blocks, on flat-bottom trench, with tamped backfill (Laying Condition B), under 5 ft of cover. For other conditions see Tables 6.J and 6.5 hereof and ANSI A21.1 (AWWA CIOI).
Size Thickness OD
Weight Based on 18-ft Laying Length
Weight Based on 20-ft Laying Length
Per Lengtht Avg. per Foott Per Lengtht Avg. per FootJ
in. lb
Working Pressure 50 psi--115 ft Head
3* 0.32 3.96 215 12.0
240 11.9
4 0.35 4.80 290 16.2 320 16.1
6 0.38 6.90 460 25.5 510 25.4
8 0.41 9.05 655 36.4 725 36.2
10
0.44
11.10
870
48.2
960 48.0
12
0.48
13.20
1,125
62.6 1,245
62.3
14
0.48
15.30
1.335
74.0 1,470
73.6
16
0.54
17.40
1.700
94.5 1,880
94.0
18
0.54
19.50
1,920
106.7
2,120
106.0
20
0.57
21.60
2.250
124.9
2,485
124.2
24
0.63
25.80
2,975
165.2
3,285
164.2
Working Pressure 100 psi--231 ft Head
3* 0.32 3.96 215 12.0
240 11.9
4 0.35 4.80 290 16.2 320 16.1
6 0.38 6.90 460 25.5 510 25.4
8 0.41 9.05 655 36.4 725 36.2
10
0.44
11.10
870
48.2
960 48.0
12
0.48
13.20
1.125
62.6 1.24S
62.3
14
0.51
15.30
1.410
78.2 1.555
77.8
16
0.54
17.40
1,700
94.5 1,880
94.0
18
0.58
19.50
2,050
113.9
2,265
113.2
20
0.62
21.60
2.430
134.9
2,685
134.2
24
0.68
25.80
3,190
177.2
3,525
176.2
Working Pressure 150 psi--346 ft Head
3* 0.32
3.96 215 12.0
240 11.9
4 0.35 4.80 290 16.2 320 16.1
6 0.38 6.90 460 25.5 510 25.4
8 0.41 9.0S 655 56.4 725 36.2
10 0.44 11.10 870 48.2 960 48.0
12
0.48
13.20
1,125
62.6 1,245
62.3
14
0.51
15.30
1,410
78.2 1.555
77.8
16
0.54
17.40
1,700
94.5 1,880
94.0
18
0.58
19.50
2,050
113.9
2,265
113.2
20
0.62
21.60
2.430
134.9
2,685
134.2
24
0.73
25.80
3,405
189.2
3,765
188.2
Working Pressure 200 psi-- 462 ft Head
3* 0.32 3.96 215 12.0
240 11.9
4 0.35 4.80 290 16.2 320 16.1
6 0.38 6.90 460 25.5 510 25.4
8 0.41 9.05 655 36.4 725 36.2
10 0.44 11.10 870 48.2 960 48.0
12
0.48
13.20
1,125
62.6 1,245
62.3
14
0.55
15.30
1.510
83.8 1,670
83.4
16
0.58
17.40
1,815
100.9
2,005
100.3
18
0.63
19.50
2,210
122.8
2.445
122.2
20
0.67
21.60
2,610
144.9
2.885
144.2
24
0.79
25.80
3,665
203.5
4,050
202.6
* Pipe of 3-in. size also available in 12-ft laying length. Weight per lengtht is 150 lb; average weight per foot!
(a 12.3 lb for all working pressures and heads. t Including bell. Calculated weight of pipe rounded off to nearest 5 lb. t Including belL Average weight per foot based on calculated weight of pipe before rounding.
CTD000416
<i
PlI'E CENTKIFUGALLY CAST IN METAL MOLDS
n
TABLE 6.2--(contd.)
Selection Table for Mechanical-Joint Cast-Iron Pipe
These thicknesses and weight* are for pipe laid without blocks, on flat-bottom trench, with tamped backfill (Laying Condition B), under 5 ft of cover. For other conditions see Tables 6.3 and 6.5 hereof and ANSI A2I 1 (AWWA C101).
Size Thickness OD
Weight Based on 18-ft Laying Length
Weight Based on 20-ft Laying Length
Per Lengthf Avg. per Foott Per Lengthf Avg. per Foott
in. lb
Working Pressure 250 psl--577 ft Head
3*4
6
8
0.32 0.35 0.38 0.41
3.96 4.80 6.90 9.05
215 12.0 290 16.2 460 25.5 655 36.4
240 11.9 320 16.1 510 25.4 725 36.2
10 0.44 12 0.52
11.10 13.20
870 1,215
48.2 . 960 67.4 1,340
48.0 67.1
14 16
18 20
24
0.59 0.63 0.68
0.72 0.79
15.30
17.40 19.50 21.60 25.80
1,610
1,960 2,370 2,785 3,665
89.4 108.9 131.7 154.8
203.5
1,780
2,165 2,620
3.080 4,050
89.0
108.3 131.0 154.1 202.6
Working Pressure 300 psi--693 ft Head
0.32 0.35 0.38 0.41 0.48 0.52
0.59 0.68 0.73 0.78 0.85
3.96 4.80 6.90 9.05 11.10 13.20
15.30 17.40 19.50 21.60 25.80
215 290 460 655 940 1,215
1,610 2,100 2,530 3,000 3.920
12.0 16.2 25.5 36.4 52.2 67.4
89.4 116.7 140.6 166.6 217.7
240 320 510 725 1,040 1,340
1,780 2,325 2.800 3,320 4,335
11.9 16.1 25.4 36.2 52.0 67.1
89.0 116.2 140.0 165.9 216.8
Working Pressure 350 psl--808 ft Head
3* 0.32 4 0.35 6 0.38
3.96
4.80 6.90
215 12.0 290 16.2 460 25.5
240 11.9 320 16.1 510 25.4
1210
0.41 0.52
9.05 11.10
655 1,010
36.4 725 56.1 1,120
36.2 55.9
0.56
13.20
1,300
72.2 1,440
71.9
14 16 18
20
24
0.64 0.68 0.79 0.84 0.92
15.30
17.40 19.50 21.60 25.80
1,735
2,100
2,720 3,210 4,215
. |
1
96.3
116.7 151.2 178.3 234.2
1,920
2,325 3,010 3,550 4,665
95.9
116.2 150.6 177.6
233.2
, . **!*?? * ln- sk* 1,30 available 1" ,12-ft laying length. Weight per lengthf is 150 lb; average weight per footl la 12.3 lb for all working pressures and heads.
f Including bell. Calculated weight of pipe rounded off to nearest 5 lb. t Including belL Average weight per foot based on calculated weight of pipe before rounding.
CTD000417
12 AMERICAN NATIONAL SIANIiaKI
TABLE 6.3
Standard Thickness* Selection Table for Cast-Iron Pipe
Laying Condition A--flat-bottom trench, without blocks, untamped backfill Laying Condition B--flat-bottom trench, without blocks, tamped backfill Laying Condition F--pipe laid on gravel or sand bedding, backfill tamped
3$-ft Cover
5-ft Cover
S-ft Cover
Size
IK.
Working Pressure
psi
Laying Condition ABF
Laying Condition A BF
Laying Condition A BF
Thickness*--in.
3 50 0.32 0.32 0.32 0.32 0.32 0.32 0.32 0.32 0.32
100
0.32
0.32
0.32
0.32
0.32
0.32
0.32
0.32
0.32
150 0.32 0.32 0.32 0.32 0.32 0.32 0.32 0.32 0.32
200 0.32 0.32 0.32 0.32 0.32 0.32 0.32 0.32 0.32
250 0.32 0.32 0.32 0.32 0.32 0.32 0.32 0.32 0.32
300 0.32 0.32 0.32 0.32 0.32 0.32 0.32 0.32 0.32
350 0.32 0.32 0.32 0.32 0.32 0.32 0.32 0.32 0.32
4 50 0.35 0.35 0.35 0.35 0.35 0.35 0.35 0.35 0.35
100
0.35
0.35
0.35
0.35
0.35 0.35 0.35
0.35
0.35
ISO 0.35 0.35 0.35 0.35 0.35 0.35 0.35 0.35 0.35
200 0.35 0.35 0.35 0.35 0.35 0.35 0.35 0.35 0.35
250 0.35 0.35 0.35 0.35 0.35 0.35 0.35 0.35 0.35
300 0.35 0.35 0.35 0.35 0.35 0.35 0.35 0.35 0.35
350 0.35 0.35 0.35 0.35 0.35 0.35 0.35 0.35 0.35
6
50
0.38 0.38 0.38 0.38 0.38 0.38 0.38
0.38
0.38
100
0.38 0.38 0.38 0.38 0.38 0.38 0.38
0.38
0.38
150
0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.38
200
0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.38
250 0.38 0.38 0.38 0.38 0.38 0.38 0.38 0.38 0.38
300
0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.38
350 0.38 0.38 0.38 0.38 0.38 0.38 0.38 0.38 0.38
8 50 0.41 0.41 0.41 0.41 0.41 0.41 0.41 0.41 0.41 100 0.41 0.41 0.41 0.41 0.41 0.41 0.41 0.41 0.41 150 0.41 0.41 0.41 0.41 0.41 0.41 0.41 0.41 0.41 200 0.41 0.41 0.41 0.41 0.41 0.41 0.41 0.41 0.41 250 0.41 0.41 0.41 0.41 0.41 0.41 0.44 0.41 0.41 300 0.41 0.41 0.41 0.41 0.41 0.41 0.44 0.44 0.41 350 0.41 0.41 0.41 0.52 0.41 0.41 0.48 0.44 0.44
10
50
0.44
0.44
0.44
0.44
0.44
0.44
0.44
0.44
0.44
100 0.44 0.44 0.44 0.44 0.44 0.44 0.48 0.44 0.44
150
0.44
0.44
0.44
0.44
0.44
0.44
0.48
0.44
0.44
200
0.44
0.44
0.44
0.44
0.44
0.44
0.48
0.48
0.44
250
0.44
0.44
0.44
0.48
0.44
0.44
0.52
0.48
0.48
300 0.48 0.44 0.44 0.48 0.48 0.48 0.52 0.52 0.48
350 0.48 0.48 0.48 0.52 0.52 0.48 0.56 0.52 0.52
12
50
0.48 0.48 0.48 0.48 0.48 0.48 0.52
0.48
0.48
too
0.48 0.48 0.48 0.48 0.48 0.48 0.52
0.48
0.48
150 0.48 0.48 0.48 0.48 0.48 0.48 0.52 0.52 0.46
200 0.48 0.48 0.48 0.48 0.48 0.48 0.56 0.52 0,46
250
0.52 0.48 0.48 0.52 0.52 0.48 0.56
0.56
0.52
300
0.52 0.52 0.52 0.56 0.52 0.52 0.60
0.56
0.56
350
0.56 0.56 0.52 0.56 0.56 0.56 0.60
0.60
0.60
14
50
0.51
0.48
0.48
0.51
0.48
0.48
0.59
0.55
0.51
100 0.51 0.48 0.48 0.55 0.51 0.48 0.59 0.55 0.51
150
0.55 0.51 0.48 0.55 0.51 0.48 0.64
0.59
0.55
200 0.55 0.51 0.51 0.55 0.55 0.51 0.64 0.59 0.59
250
0.59
0.55
0.55
0.59
0.59 0.55
0.64
0.64
0.59
300
0.59 0.59 0.59 0.64 0.59 0.59 0.69
0.64
0.64
350
0.64
0.64 0.64
0.64
0.64 0.64 0.75
0.69
0.64
* Thicknesses include allowances for foundry practice, corrosion, and either water hammer or truck lord.
CTD000418
PIPE CENTK1EUGALLY CAST IN METAL MOLDS
13
TABLE 6.3--{contd.)
Standard Thickness* Selection Table for Cast-Iron Pipe
Laying Condition A--flat-bottom trench, without blocks, untamped backfill Laying Condition B--flat-bottom trench, without blocks, tamped backfill Laying Condition F--pipe laid on gravel or sand bedding, backfill tamped
3J-ft Cover
5-ft Cover
8-ft Cover
Size in. #
Working
Pressure Psi
Laying Condition ABF
Laying Condition ABF
Laying Condition ABF
Thickness*--in.
16
50
0.54 0.50
0.50
0.58
0.54
o.so 0.63
0.58 0.54
100
0.54 0.54 0.50 0.58 0.54 0.50 0.63
0.58
0.54
150
0.58
0.54
0.50
0.58
0.54
0.54
0.68
0.63
0.58
200 0.58 0.58 0.54 0.63 0.58 0.58 0.68 0.63 0.63
250 0.63 0.58 0.58 0.63 0.63 0.58 0.73 0.68 0.63
300 0.63 0.63 0.63 0.68 0.68 0.63 0.73 0.73 0.68
350 0.68 0.68 0.68 0.73 0.68 0.68 0.79 0.73 0.73
18
50
0.58
0.54
0.54
0.58
0.54
0.54
0.68
0.63
0.58
100
0.58
0.54
0.54
0.63
0.58
0.54
0.68
0.63
0.58
150
0.63
0.58
0.54
0.63
0.S8
0.58 0.73
0.68
0.63
200 0.63 0.58 0.58 0.68 0.63 0.58 0.73 0.68 0.63
250
0.68
0.63
0.63
0.68
0.68
0.63 0.79
0.73
0.68
300
0.68 0.68 0.68 0.73 0.73 0.68 0.79
0.79
0.73
350
0.79 0.73 0.73 0.79 0.79 0.73 0.85
0.85
0.79
20 50 0.62 0.57 0.57 e.67 0.57 0.57 0.72 0.67 0.62
too 0.62 0.57 0.57 0.67 0.62 0.57 0.72 0.67 0.62
ISO 0.67 0.62 0.57 0.67 0.62 0.62 0.78 0.72 0.67
200
0.67 0.62 0.62 0.72 0.67 0.62 0.78
0.72
0.67
250 0.72 0.67 0.67 0.78 0.72 0.67 0.84 0.78 0.72
300
0.78
0.72
0.72
0.78
0.78
0.72
0.84
0.84
0.78
350
0.84 0.78 0.78 0.84 0.84 0.78 0.91
0.84
0.84
24
SO
0.68
0.63
0.63
0.73
0.63
0.63
0.79
0.73
0.68
100
0.73
0.63
0.63
0.73
0.68
0.63
0.85
0.73
0.68
150 0.73 0.68 0.63 0.79 0.73 0.68 0.85 0.79 0.73
200 0.79 0.73 0.68 0.79 0.79 0.73 0.92 0.85 0.79
250
0.79 0.79 0.73 0.85 0.79 0.79 0.92
0.85
0.85
300 0.85 0.85 0.85 0.92 0.85 0.85 0.99 0.92 0.92
350
0.92
0.92
0.92
0.99
0.92
0.92
1.07
0.99
0.92
* Thicknesses Include allowances for foundry practice* corrosion, and either water hammer or truck load.
CTD000419
14 AMERICAN NATIONAL STANDARD
TABLE 6.4 Standard Dimensions and Weights of Push-On Joint Cast-Iron Pipe||
Thick
Size in.
Thick
ness Class
ness
ODt
Weight of Barrel
per Foot
Weight of Bell
Weight Based on 18-ft Laying
Length
Weight Based on 2<Wt Laying Length
Per Avg. per Per Avg. per
Length^
FootJ
Length}
Foot!
in. lb
3* 22 23 24
1 22 23 24 25
6 22 23 24 25 26
8 22 23 24 25 26 27
10 22 23 24 25 26 27
12 22 23 24 25 26 27 28
0.32 0.35 0.38
0.35 0.38 0.41 0.44
0.38 0.41 0.44 0.48 0.52
0.41 0.44 0.48 0.52 0.56 0.60
0.44 0.48 0.52 0.56 0.60 0.65
0.48 0.52 0.56 0.60 0.65 0.70 0.76
3.96 3.96 3.96
4.80 4.80 4.80 4.80
6.90 6.90 6.90 6.90 6.90
9.05 9.05 9.05 9.05 9.05 9.05
11.10 11.10 11.10 11.10 11.10 11.10
13.20 13.20 13.20 13.20 13.20 13.20 13.20
11.4 12.4 13.3
15.3 16.5 17.6 18.8
24.3 26.1 27.9 30.2 32.5
34.7 37.1 40.3 43.5 46.6 49.7
46.0 50.0 53.9 57.9 61.8 66.6
59.8 64.6 69.4 74.1 80.0 85.8 92.7
11
215 12.0
240 11.9
11
235 13.0
260 12.9
11
250 13.9
275 13.8
14
290 16.1
320 16.0
14 310 17.3 345 17.2
14 330 18.4 365 18.3
14
350 19.5
390 19.5
25
460 25.6
510 25.6
25
495 27.5
545 27.4
25
525 29.3
585 29.2
25
570 31.7
630 31.4
25
610 33.9
675 33.8
41
665 36.9
735 36.8
41
710 39.4
785 39.2
#>41
765 42.6
845 42.4
41
825 45.8
910 45.6
41
880 48.9
975 48.6
41 935 52.0 1,035 51.8
54
880 49.0
975 48.7
54 955 53.0 1,055 52.7
54
1,025
56.9
1,130 56.6
54
1,095
60.9
1,210 60.6
54 1,165 64.8 1,290 64.5
54 1,255 69.6 1,385 69.3
66 1,140 63.4 1,260 63.1
66
1,230 68.3
1,360 67.9
66
1,315
73.1
1,455
72.7
66 1,400 77.8 1,550 77.4
66
1,505
83.7
1,665
83.3
66
1,610 89.5
1,780 89.1
66 1,735 96.4 1,920 96.0
* Pipe of 3-in. size also available in 12-ft laying length. Weight (lb) per length! for thickness class 22 is ISO; for 23, 160; for 24, 170, Average weight (lb) per foot} for thickness class 22 is 12.5; for 23, 13.5; for 24, 14.3,
t Including bell. Calculated weight of pipe rounded off to nearest 5 lb.
4 Including bell. Average weight per foot based on calculated weight of pipe before rounding.
T Tolerances of OD of spigot end: 3-12 in., 0.06 in..; 14-24 in., +0.05 in., --0.08 In.
II Weights shown for push-on joint pipe are also applicable to bell-and-spigot joint pipe.
CTD000420
PIPE CENTRIFUGALLY CAST IN METAL MOLDS
15
TABLE 6.4--(contd.) Standard Dimensions and Weigkls of Push-On Joint Cast-Iron Pipe\\
Thick
Size in.
Thick ness Class
ness
ODf
Weight of Barrel
per Foot
Weight of Bell
Weight Based on 18-ft Laying Length
Weight Based on 20-ft Laying
Length
Per Avg. per Per Avg. per
Length^ Foot}
Length!
Foot
in. tb
14 21 22 23 24 25 26 27 28
0.48 0.51 0.55 0.59 0.64 0.69 0.75 0 81
15.30 15.30 15.30 15.30 15.30 1.530 15.30 15.30
69.7 73.9 79.5 85.1 92.0 98.8 107.0 115.0
78 1,335 74.1 1,470
78 1,410 78.2 1,555
78
1,510
83.8
1,670
78 1,610 89.5 1,780
78
1,735
96.3
1,920
78
1,855
103.1
2,055
78
2,005
111.3
2,220
78
2,150 119.3
2,380
16 21 22 23 24 25 26 27 28
0.50 0.54 0.58 0.63 0.68 0.73 0.79 0.85
17.40 17.40 17.40 17.40 17.40 17.40 17.40 17.40
82.8 89.2 95.6 103.6 111.4 119.3 128.6 137.9
96 1,585 88.1 1,750
96
1,700
94.5
1,880
96 1,815 100.9 2,010
96 1,960 109.0 2,170
96 2,100 116.8 2,325
96 2,245 124.6 2,480
96 2,410 133.9 2,670
96
2,580 143.2
2,855
18 21
0.54
19.50 100.4
114
1,920 106.7
2,120
22
0.58
19.50 107.6
114
2,050 113.9
2,265
23
0.63
19.50 116.5
114
2,210
122.8
2,445
24
0.68
19.50 125.4
114
2,370 131.8 2,620
25 0.73 19.50 134.3 114 2,530 140.6 2,800
26
0.79
19.50 144.9
114
2,720 151.2
3,010
27
0.85
19.50 155.4
114
2,910 161.7
3,220
28
0.92
19.50 167.5
114
3,130 173.8 3,465
20 21 22 23 24 25 26 27 28
0.57
21.60 117.5
133 2,250 124.9 2,485
0.62
21.60 127.5
133
2,430
134.9
2,685
0.67
21.60 137.5
133
2,610 144.9 2,885
0.72
21.60 147.4
133
2,785 154.8 3,080
0.78
21.60
159.2
133
3,000 166.6 3,315
0.84
21.60 170.9
133
3,210 178.4 3,550
0.91
21.60 184.5
133
3,455 191.9 3,825
0.98
21.60 198.1
133
3,700 205.5 4,095
24 21
0.63
25.80 155.4
179
2,975
165.3
3,285
22
0.68
25.80
167.4
179
3,190
177.3
3,525
23 0.73 25.80 179.4 179 3,410 189.4 3,765
24
0.79
25.80 193 7
179
3,665 203.6 4,055
25
0.85
25.80 207.9
179
3,920
217.8
4,335
26
0.92 25.80 224.4
179
4,220 234.4
4,665
27
0.99
25 80 240.8
179
4,515
250.7
4,995
28 1 07 25.80 259.4 I 179 4,850 269.3 5,365
f Including bell. Calculated weight of pipe rounded off to nearest 5 lb. $ Including bell. Average weight per foot based on calculated weight of pipe before rounding.
f Tolerances of OD of spigot end: 3-12 in., 0.06 in.; 14-24 in., +0.05 in., -0.08 in.
\ Weights shown for push-on joint pipe are also applicable to bell-and-spigot joint pipe.
73.6 77.8 83.4 89.0 95.9 102.7 110.9 118.9
87.6 94.0 100.4 108.4 116.2 124.1 133.4 142.7
106.1 113.3 122.2 131.1 140.0 150.6 161.1 173.2
124.2 134.2 144.2 154.0 165.8 177.6 191.2 204.8
164.4 176.4 188.4 202.6 216.8 233.4 249.8 268.4
CTD000421
16 AMERICAN' NATIONAL STANDARD
TABLE 6.5 Standard Dimensions and Weights of Mechanical-Joint Cast-Iron Pipe
Thick-
Size in.
Thick ness Class
Weight Based on
Weight Based on
18-ft Laying
20-ft Laying
ODf
Weight of Barrel per Foot
Weight of BeU
Length
Length
Per Avg. per Per Avg. per
Length! Foot} Length! Foot}
in. lb
3* 22 23 24
4 22 23 24 25
6 22 23 24 25 26
8 22 23 24 25 26 27
10 22 23 24 25 26 27
12 22 23 24 25 26 27 28
0.32 0.35 0.38
0.35 0.38 0.41 0.44
0.38 0.41 0.44 0.48 0.52
0.41 0.44 0.48 0.52 0.56 0.60
0.44 0.48 0.52 0.56 0.60 0.65
0.48 0.52 0.56 0.60 0.65 0.70 0.76
3.96 3.96 3.96
4.80 4.80 4.80 4.80
6.90 6.90 6.90 6.90 6.90
9.05 9.05 9.05 9.05 9.05 9.05
11.10 11.10 11.10 11.10 11.10 11.10
13.20 13.20 13.20 13.20 13.20 13.20 13.20
11.4 12.4 13.3
15.3 16.5 17.6 18.8
24.3 26.1 27.9 30.2 32.5
34.7 37.1 40.3 43.5 46.6 49.7
46.0 50.0 53.9 57.9 61.8 66.6
59.8 64.6 69.4 74.1 80.0 85.8 92.7
11
215 12.0
240 11.9
11
235 13.0
260 12.9
11
250 13.9
275 13.8
16
290 16.2
320 16.1
16
315 17.4
345 17.3
16
335 18.5
370 18.4
16
355 19.7
390 19.6
22
460 25.5
510 25.4
22
490 27.3
545 27.2
22
525 29.1
580 29.0
22
565 31.4
625 31.3
22
605 33.7
670 33.6
30
655 36.4
725 36.2
30
700 38.8
770 38.6
30
755 42.0
835 41.8
30
815 45.2
900 45.0
30
870 48.3
960 48.1
30 925 51.4 1,025 51.2
40
870 48.2
960 48.0
40 940 52.2 1,040 52.0
40 1,010 56.1 1,120 55.9
40 1,080 60.1 1,200 59.9
40 1,150 64.0 1,275 63.8
40 1,240 68.8 1,370 68.6
50 1,125 62.6 1,245 62.3 50 1,215 67.4 1,340 67.1 50 1,300 72.2 1,440 71.9 50 1,385 76.9 1,530 76.6 50 1,490 82.8 1,650 82.5 50 1,595 88.6 1,765 88.3 50 1,720 95.5 1,905 95.2
* Pipe of 3-in. size also available in I2-ft laying length. Weight (lb) per length! for thickness class 22 is 150;
tor 23. .for 24. 170. Average weight (lb) per foot} for thickness class 22 is 12.3; for 23, 13.3 ; for 24, 14.2. t Including bell. Calculated weight of pipe rounded oS to nearest 5 lb.
3 Including bell. Average weight per foot based on calculated weight of pipe before rounding,
t Tolerances of OD of spigot end: 3-12 in., 0.06 in.; 14-24 in., +0.05 in.. --0.08 in.
CTD000422
PIPE CENTRIFL'GALLY CAST IN METAL MOLDS
17
TABLE 6.5--(contd.) Standard Dimensions and Weights of Mechanical-Joint Cast-Iron Pipe
Thick
Size
Thick ness
ness
IK. Class
ODf
Weight of Barrel per Foot
Weight of Bell
Weight Based on 18-ft Laying Length
Weight Based on 20-ft Laying Length
Per Avg. per Per Avg. per Length} Foot} Length} Foot}
in. It
14 21 22 23 24 25 26 27 28
0.48 0.51 0.55 0.59 0.64 0.69 0.75 0.81
15.30 15.30 15.30 15.30 15.30 15.30 15.30 15.30
69.7 73.9 79.5 85.1 92.0 98.8 107.0 115.0
78 1,335 74.0 1,470 78 1,410 78.2 1,555 78 1,510 83.8 1,670 78 1,610 89.4 1,780 78 1,735 96.3 1,920 78 1,855 103.1 2,055 78 2,005 111.3 2,220 78 2,150 119.3 2,380
16 21
0.50
17.40
82.8
95 1,585 88.1 1,750
22
0.54
17.40
89.2
95 1,700 94.5 1,880
23
0.58
17.40
95.6
95 1,815 100.9 2,005
24
0.63
17.40 103.6
95 1,960 108.9 2,165
25
0.68
17.40 111.4
95 2,100 116.7 2,325
26
0.73
17.40 119.3
95 2,240 124.6 2,480
27
0.79
17.40 128.6
95 2,410 133.9 2,665
28
0.85
17.40 137.9
95 2,575 143.2 2,855
18 21
0.54
19.50 100.4
113
1,920 106.7 2,120
22
0.58
19.50 107.6
113
2,050 113.9 2,265
23
0.63
19.50 116.5
113
2,210 122.8 2,445
24
0.68
19.50 125.4
113
2,370 131.7 2,620
25 0.73 19.50 134.3 113 2,530 140.6 2,800
26
0.79
19.50 144.9
113
2,720 151.2 3,010
27 0.85 19.50 155.4 113 2,910 161.7 3,220
28
0.92
19.50 167.5
113 3,130 173.8 3,465
20 21
0.57
21.60 117.5
134
2,250 124.9 2,485
22 0.62 21.60 127.5 134 2,430 134.9 2,685
23
0.67
21.60 137.5
134
2,610 144.9 2,885
24
0.72
21.60 147.4
134
2,785 154.8 3,080
25
0.78
21.60 159.2
134
3,000 166.6 3,320
26
0.84
21.60 170.9
134
3,210 178.3 3,550
27 0.91 21.60 184.5 134 3,455 191.9 3,825
28
0.98
21.60 198.1
134
3,700 205.5 4,095
24 21
0 63
25.80 155.4
177
2,975
165.2 3,285
22
0.68
25.80 167.4
177
3,190 177.2 3,525
23
0.73
25.80 179.4
177
3,405 189.2 3,765
24
0.79
25.80 193.7
177
3,665 203.5 4,050
25
0 85
25.80 207.9
177
3,920 217.7 4,335
26 0.92 25.80 224.4 177 4,215 234.2 4,665
27
0.99
25.80 240.8
177
4,510 250.6 4,995
28 1.07 25.80 259.4 177 4,845 269.2 5,365
t Including bell. Calcaulated weight of pipe rounded off to nearest 5 lb. Including bell. Average weight per foot baaed on calculated weight of pipe before rounding,
f Tolerances of OD of spigot end: 3-12 in., =fc0.06in.; 14-24 in., +0.05 in., --0.08 in.
73.6 77.8 83.4 89.0 95.9 102.7 110.9 118.9
87.6 94.0 100.3 108.3 116.2 124.0 133.3 142.7
106.0 113.2 122.2 131.0 140.0 150.6 161.0 173.2
124.2 134.2 144.2 154.1 165.9 177.6 191.2 204.8
164.2 176.2 188.2 202.6 216.8 233.2 249.7 268.2
CTD00Q423
IX AMERICAN' NATIONAL STANDARD
TABLE 6.6
Standard Bell-and-Spigot Joint Dimensions
For weights of bell-and-spigot joint pipe see Tables 6.1 and 6.4.
Pipe ODf
Socket Diam. at
Thickness of Joint L
Socket Depth 4
Centering Shoulder
Depth 0
ID ft
3
3.96 4.76 0.40 3.30 0.30
4.10
4
4.80 5.60 0.40 3.30 0.30
4.94
6
6.90 7.70 0.40 3.88 0.38
7.06
8
9.05 9.85 0.40 4.38 0.38
9.21
10
11.10
11.90
0.40
4.38
0.38
11.28
12
13.20
14.00
0.40
4.38
0.38
13.38
14
15.30
16.10
0.40
4.50
0.50
15.52
16
17.40
18.40
0.50
4.50
0.50
17.62
18
19.50
20.50
0.50
4.50
0.50
19.72
20
21.60
22.60
0.50
4.50
0.50
21.82
24
25.80
26.80
0.50
4.50
0.50
26.02
t Tolerances for outside diameter of spigot ends, socket diameter a, and centering shoulder inside diameter shall be 0.06 in. for sizes 3-12 in.; 0.08 in. for sizes 14-24 in.
I P -- 1 75C--8/ 75--43 106
CTD000424