Document RawnDgDz8GNDb878ZGJ5rpQZX
Jean B. Sweeney Vice President
3M Environmental, Health and Safety Operations
R rvC E !v r n
'l
3M Center, Building 0224-05RV-1)3 St. Paul, MN 55144-1000 651 737 3569
April 13,2010
Document Processing Center (Mail Code 7407M) Room 6428 Attention: TSCA 8(e) Coordinator Office of Pollution Prevention and Toxics U.S. Environmental Protection Agency 1200 Pennsylvania Ave. N.W. Washington, D.C. 20460
226' 3?36
Re: TSCA Section 8(e) Notice: Sulfonate-based and Carboxylic-based Fluorochemicals, Docket 8EHQ-0598-373 - Emerald Coast Utilities Authority Information
Dear Sir/Madam:
3M is one of several defendants in litigation in federal court in Pensacola, Florida, brought by the Emerald Coast Utilities Authority ("ECUA"). ECUA contends that low levels of PFOA and PFOS are present in some of its drinking water supply wells. ECUA indicated that it had tested four drinking water supply wells in November 2006 and identified the presence of PFOA and PFOS at low parts per trillion levels in those wells. As EPA may be aware, ECUA published a summary of those data in its 2006 annual Consumer Confidence Report under the Safe Drinking Water Act, which is reported to the Florida Department of Environmental Protection pursuant to EPA regulations.
As part of discovery in the litigation, ECUA has now provided 3M and the other parties with additional data in the form of a laboratory report from Columbia Analytical Sendees, reporting on testing conducted for the litigation of 28 supply wells (including the original four wells) for various perfluorinated alkyl acids. We enclose a copy of the 2006 report and this more recent 2010 report. 3M cannot vouch for the reliability of the data. The analyses do not appear to follow EPA Method 537 for determination of perfluorinated alkyl acids in drinking water, and we have not been provided with the analytical method, method validation or supporting quality control data.
Although 3M does not believe the enclosed data meet the reporting threshold of TSCA Section 8(e), we recognize the ongoing work by U.S. EPA to assess fluorochemical exposure pathways, and we are therefore placing a notification in the TSCA 8(e) docket.
WDC IMANAGE-1483131.1
OONTMNSNOCa
3 L.(o 22
Docum ent P ro ce ssin g C enter (Mail C o d e 7407M) Page 2
p .2
If you have any questions, please do not hesitate to contact Dr. William Reagen at (651) 733-9739 or Gary Hohenstein at (651) 737-3570.
Sincerely,
Jean B. Sweeney Staff Vice President 3M Environmental, Health and Safety Operations
Enclosures (2)
WDC IMANAGE-1483131.1
Baron & Budd, P.C.
Emerald Coast U tilities Authority Production W ell Sam pling Results Escambia County, Florida February 2010
Final Letter Report
P-4
CDM
3522 Thomasville Road, Suite 300 Tallahassee, Florida 32309 Office: 850-386-9500 Fax: 850-668-6745
CDM Transmittal
Confidential Client Material
To: Organization/ Address:
Re:
Mr. Chad A. West, Attorney
From:
Baron & Budd, P.C. 3102 Oak Lawn Avenue, Suite 1100 Date: Dallas, Texas 75219 ECUA - Production W ell Sam pling Results Escambia County, Florida
David L. Anderson February 24,2010
Job#:
95779-75319
Via: Mail:
Overnight:
X
Courier:
Enclosed please find:
For your information
X
Approved
For your review
X
Approved as noted
For your signature
Returned to you for correction
Message:
Mr. West,
Camp Dresser & McKee Inc. is pleased to submit this letter report to Baron & Budd summarizing the analytical results of the February 2010 comprehensive groundwater sampling event. One original (with Appendix D lab data) and one copy (Appendix D compact disk) are provided for your use.
If you have any questions regarding this submittal, please contact me at (850) 386-9509 or by email at andersondl @cdm .com.
Copy: Michael H. Edgar - CDM/Tallahassee
Signed
CDM 3522 Thom asville Road, Suite 300 Tallahassee, Florida 32309 tel: +1 850 386-9500 fax: +1 850 668-6745
P-5
February 24, 2010
CONFIDENTIAL CLIENT MATERIAL
Mr. Chad A. West, Attorney at Law Baron & Budd, P.C. 3102 Oak Lawn Avenue, Suite 1100 Dallas, Texas 75219
Subject:
Emerald Coast Utilities Authority - Production Well Sampling Results Escambia County, Florida CDM Project No. 95779-75319
Dear Mr. West:
Camp Dresser & McKee Inc. (CDM) is pleased to present this letter report to Baron & Budd, P.C. (B&B) summarizing the February 2010 groundwater sampling of production w ells within the Emerald Coast Utilities Authority (ECUA) water distribution system. These services were performed in accordance with CDM's scope of services and cost estimate dated January 15, 2010--approved by B&B on January 25,2010.
Groundwater samples were collected and analyzed for Perfluorooctane sulfonate (PFOS), perfluorooctanoic acid (PFOA), and other related fluorinated compounds. The U.S. Environmental Protection Agency and the Florida Department of Environmental Protection (FDEP) have not established maximum contaminant levels for these compounds.
This letter report presents the groundwater sampling methods and groundwater analytical results.
Groundwater Sampling Methods
Raw and treated groundwater sam ples were collected from 28 of the 32 active production wells w ithin the ECUA water distribution system. A production w ell location map (which identifies w ells w ith raw water treatment systems) is included in Appendix A. From February 1 to February 3,2010, samples were collected by a Florida-Registered Professional Geologist trained and experienced in FDEP sam pling protocols in accordance with the procedures described in the FDEP Standard Operating Procedures (SOP) FS 2000 and FS 2300. FDEP's sam pling documentation procedures were follow ed as described in FDEP SOP FD 5000 and FD 5100. Field parameters (pH, specific conductance, temperature, dissolved oxygen, and turbidity were measured during purging in accordance with procedures described in FDEP SOPs FT 1100, FT 1200, FT 1400, FT 1500, and FT 1600. In addition, oxidation-reduction potential readings were collected in the field.
co n s u ltin g engine e ring construction operations
2010-02-24_BB W ell Sampling Results Letter Report.docx
CDM
P-6
Mr. Chad A. West, Attorney at Law February 24,2010 Page 2
ECUA staff escorted CDM staff during the sampling activities due to security reasons. A photograph log of all 32 w ells is included in Appendix B.
The follow ing sample collection procedures were followed at each w ell location:
Samples were collected during active groundwater pumping.
Sam pling ports (raw and treated) were opened upon arrival at each site to flush the lines.
Field parameters were collected every 3 minutes and recorded until stable.
Raw samples were collected at the wellhead and treated samples were collected at the nearest sampling port downstream of final treatment.
Samples were collected at a flow rate of approximately 100 milliliters per minute in laboratory supplied bottleware.
Samples were labeled, bagged, and stored on ice to maintain a temperature of 4 degrees C elsius (4C).
Chain-of-custody forms were completed prior to departure from an individual w ell site location.
Samples remained in the custody of CDM prior to nightly overnight shipment (next morning delivery) to the laboratory.
At the request of B&B, groundwater samples were analyzed by Columbia Analytical Services (CAS) of Kelso, Washington. Each sample was analyzed for PFOS, PFOA, and other fluorinated compounds by CAS Method HPLC/MS - PFOA. Three field blanks samples were collected (one each day prior to initiating sampling) to document:
Sampling environment.
Analyte-free water chemistry.
Clean bottleware.
Sample transport.
Storage conditions as required by FDEP field quality control requirements (FDEP SOP FQ 1230).
2010-02-24_BB Well Sampling Results Letter Report-docx
CDM
p .7
Mr. Chad A. West, Attorney at Law February 24, 2010 Page 3
Matrix spike/m atrix spike duplicate samples (raw and treated) were collected at the Bronson and M cAllister production w ells as requested by CAS.
Groundwater Analytical Results
The follow ing 28 production w ells were sam pled in the following order:
February 1, 2010 1. Ellyson. 2. D avis. 3. O live. 4. Carriage Hills. 5. Watson. 6. K ingsfield Road. 7. Cantonment. 8. N ine Mile Road.
February 2, 2010 9. University Parkway. 10. McCory. 11. Dunaway. 12. Lillian. 13. Bronson. 14. W est Pensacola. 15. "W" & Avery. 16. West Plant Well. 17. "F" & Scott. 18. No. 6 WeH Plant.
February 3, 201.0 19. Hagler Well Plant. 20. Spanish Trail. 21. Airport North. 22. McAllister. 23. Humphrey. 24. Broad. 25. Tennant. 26. Muldoon. 27. Villa Drive. 28. Royce Street.
The follow ing four w ells were not sam pled due to the reasons stated below:
1. Avondale - the pump motor w as hit by lightning in late January 2010 and was not in operation during the sampling event. See Page 26 in Appendix B.
2. F.nsley - the site has been inactive for several years and ECUA has no plans to reactivate the w ell. The discharge lines from the w ell have been plugged and the wellhead has no power.. See Page 30 in Appendix B.
3. Sw eeney - the entire site is currently undergoing complete rehabilitation including underground piping, electrical, a new pump house building, and w ell modifications. This project is expected to be com plete by the fall of 2010. See Page 31 in Appendix B.
4. 01,1-4 A - the w ell w as down because of routine maintenance including extraction of the w ell screen for cleaning. See Page 32 in Appendix B.
2010-02-24_BB Well Sampling Results Letter Report.docx
CDM
Mr. Chad A. West, Attorney at Law February 24,2010 Page 4
Table 1 is a summary of the CAS analytical data. PFOA concentrations ranged from nondetect (in several wells) to 68 nanograms per liter (ng/1 (or parts per trillion)) in the treated sample from the Bronson well. PFOS concentrations ranged from 0.19 n g/L in the raw sample collected from the Cantonment w ell to 240 n g/L in the treated sample collected from the Hagler well. A groundwater sample collection sheet (raw and treated) for each w ell location and field equipm ent calibration logs are in Appendix C. Hard copies of die CAS analytical reports (including chain-of-custodies, Tier IV Quality Assurance Data Validation Package, matrix sp ik e/ matrix spike duplicate results, and surrogate results) and a compact disk of the data are in A ppendix D. If you have any questions concerning this letter report, please call me at (850) 386-9503 or email m e at edgarmh@cdm.com. Sincerely,
Vice President Camp Dresser & McKee Inc. Enclosures: Appendix A - ECUA Production Well Location Map Appendix B - Sample Port Photograph Log Appendix C - Groundwater Sample L ogs/Field Calibration Logs Appendix D - Analytical Data/Chain-of-Custodies (Compact Disk and Hard Copy) c: D avid L. Anderson - CDM/TAL
2010-02-24_BB Well Sampling Results Letter Report.docx
nic Acids *nd Perfluorinated HPLC/MS loie Acid c Add nate id >nate id \cid :id mate d d nate (PFOS) 1 (PFOA) id \dd _____________________________ i
Units
1
1 Standard
1
|
Raw
ng/L ng/L ng/L ng/L ng/L ng/L ng/L ng/L ng/L ng/L ng/L ng/L ng/L ng/L '.g't
0.46 U 0.95 U 0.029 U 0.31 J 0.095 U 0.48 U 0.65 U 0.081 U 0.12 J 0.34 J 0.12 U 0.39 J 0.066 U 0.40 J 13 U
0.46 U 0.95 U 1.6 J 1.9 J 0.095 U 0.48 U 0.85 U 2.7 J
9.3 4.2 J 4.1 J
12 6.8 4.7 J 3o
Treated
0.46 U 0.95 U 1.6 J 1.6 J 0.095 U 0.48 U 0.85 U 2.7 J
9.2 4.4 J 4.5 J
12 6.9 4.7 J i 3L
----
Raw
Treated
" ** Raw
1
Treated |
A. f , 1W
Raw
Treated
1.0 J 0.95 U 0.91 J 0.89 J 0.23 J 0.48 U 0.85 U 1.4 J 3.0 J 2.1 J 0.36 J 4.1 J 4.0 J 2.4 J
,:u -
0.46 U 0.95 U 0.93 J 0.89 J 0.13 J 0.48 U 0.85 U 1.2 J 3.2 J 1.9 J 0.35 J 4.2 J 4.2 J 2.2 J
' 3 l"
0.46 U 0.95 U 2.5 J 2.9 J 0.095 U 0.48 U 0.85 U 4.4 J
9.6 7.3 1.9 J 9.1 10 7.9 13 U
0.46 U 0.95 U 2.6 J 3.0 J 0.095 U 0.48 U 0.85 U 4.5 J
9.6 7.3 1.8 J 9.5 9.8 8.1 t3J
0.46 U 0.95 U 0.32 J 0.36 J 0.095 U 0.48 U 0.85 U 0.32 J 1.6 J 0.79 J 0.12 U 1.6 J 1.3 J 0.84 J 1.3 J
0.46 U 0.95 U 0.31 J 0.31 J 0.23 J 0.48 U 0.85 U 0.34 J 1.5 J 0.69 J 0.12 U 1.4 J 1.2 J 0.76 J 1.3 U
4. /. I V
Raw
Treated
.'M V
Raw
Treated
Rai
0.46 U 0.95 U 0.46 J 0.39 J 0.14 J 0.48 U 0.85 U 0.53 J 2.8 J 0.90 J 0.80 J 3.1 J 1.9 J 1.0 J 1.3 U
0.46 U 0.95 U 0.32 J 0.51 J 0.095 U 0,48 U 0.85 U 0.30 J 0.65 J 0.85 J 0.26 J 0.46 J 0.85 J 1.2 J l.3 0
0.88 J 0.95 U 0.12 J 0.14 J 0.16 J 0.48 U 0.85 U 0.081 U 0.17 J 0.11 u 0.12 U 0.22 J 0.066 U 0.31 J l.3 U
0.46 U 0.95 U 0.13 J 0.25 J 0.095 U 0.48 U 0.85 U 0.28 J 0.26 J 0.60 J 0.12 U 0.33 J 0.066 U 0.96 J i .3 U
0.46 0.95 0.11 0.22 0.095 0.48 0.85 0.29 0.16 0.48 0.12 0.19 0.066 0.28. 1.31
13C5) Nonanoic Acid 1C4) Butanoic Acid JC4) Octanoic Acid i Decanoic Acid ) Hexanoic Acid i Dodecanoic Acid i Undecanorc Acid 2,3,4-13C4) Octane Sulfonate xane(1802) Sulfonate
% Recovery % Recovery % Recovery % Recovery % Recovery % Recovery % Recovery % Recovery % Recovery
103 81 90 100 83 67 56 77 80
95 90 96 88 91 98 99 104 103 107 131 76 81
79 83 82 81 75 80 77 88 89 85 102 57 46*
104 93
106 94
99
100 108 113 111
111 133
84
75
100 100 100 100 100 100 100 100 100 100 100 100 100
82 82 81 86 83 86 79 92 94 91 104 66 51
59 61 55 62 51 49* 47* 64 51 66 72 49* 52
50 49* 51 48* 47* 46* 42* 60 48* 56 72 45* 49*
74 71 70 67 66 68 77 80 77 77 100 67 77
82 81 84 81 84 80 78 90 93 87 106 90 80
otentiai
mV Standard Units
C uS/cm mg/L NTU Observation Observation
NA NA NA NA NA NA Clear None
NA 5 69 21.4 80 7.3
0 Clear None
192 7 08 21.1 150 7.5
0 Clear None
284 NA 21 7 71 4.2 0 Clear None
395 7.12 19.0 192 5.8
0 Clear None
299 5.32 21.5 96 7.0
1 Clear None
NA 6.38 20.5 138 6.9
1 Clear None
NA 4.60 22.1 37 7.6
0 Clear None
NA 7.14 21,7 82 6.3
1 Clear None
300 5.43 21.6 NA 5.4
0 Clear None
NA 7 13 21.9 149 4.6
0 Clear None
221 5.06 21.1 37 3.6
0 Ciear None
576 6.88 21 0 122 3.9
1 Clear None
NA
5.66
21.0
33
5.5
0 ---------- - a
Clear
None
w tim p iB w a te
Units
Standard
Raw
Treated
Raw
Treatod | Raw
Treated
Raw
Treated I Raw
Treated
4.4. IV
Rew
Treated
4.4. / V
Raw
Treated
Ran
ng/L ng/L ng/L ng/L ng/L ng/L ng/L ng/L ng/L ng/L ng/L ng/L ng/L ng/L ng/L
0.46 U 0.95 U 0.029 U 0.47 J 0.095 U 0.48 U 0.85 U 0.081 U 0.19 J 0.23 J 0.12 U 0.18 J 0.066 U 0.33 J 1.3 U
0.46 U 0.95 U 0.12 J 0.18 J 0.095 U 0.48 U 0.85 U 0.12 J 0.18 J 0.35 J 0.12 U 0.31 J 0.066 U 0.28 J 1.3 U
0.46 U 0.95 U 0.13 J 0.55 J 0.18 J 0.48 U 0.85 U 0.081 U 0.18 J 0.11 u 0.12 U 0.26 J 0.066 U 0.14 J 1.3 U
0.46 U 0.95 U 0.35 J 0.42 J 0.095 U 0.48 U 0.85 U 0.48 J 1.7 J 1.1 J 0.12 U 0.95 J
5.2 0.88 J 1 .3 Li
0.46 U 0.95 U 0.35 J 0.40 J 0.12 J 0.48 U 0.85 U 0.54 J 1.8 J 1.0 J 0.12 U 0.88 J
5.0 0.82 J i. 3 :J
0.46 U 0.95 U 0.15 J 0.29 J 0.095 U 0.48 U 0.85 U 0.15 J 0.56 J 0.34 J 0,12 U 0.47 J 0.066 U 0.33 J 1.3 U
0.46 U 0.95 U 0.14 J 0.15 J 0.095 U 0.48 U 0.85 U 0.093 J 0.55 J 0.33 J 0.12 U 0.38 J 0.066 U 0.18 J 1.3 U
0.46 U 0.95 U 1.9 J 2.0 J 0.26 J 0.60 J 0.85 U 2.9 J
6.7 4.7 J 0.67 J
13 9.2 5.1 .3 u
0.46 U 0.95 U 1.9 J 1.8 J 0.095 U 0.48 U 0.85 U 3.0 J
6.8 4.6 J 0.56 J
11 8.5 5.2 1.3 J
0.46 U 0.95 U 4.5 J
5.4 0.16 J 0.48 U 0.85 U
7.7 33 14 0.98 J 56 25 13 1.3 U
0.46 U 0.95 U
12 9.7 0.095 U 0.48 U 0.85 U 18 98 37 1.6 J 81 68 32 1.3 U
0.46 U 0.95 U 0.76 J 0.54 J 0.095 U 0.48 U 0.85 U 0.74 J 2.6 J 0.92 J 0.63 J
5,9 2.7 J 0.87 J 1.3 U
0.46 U 0.95 U 0.029 U 0.25 J 0.095 U 0.48 U 0.85 U 0.081 U 0.17 J 0.21 J 0.12 U 0.28 J 0.066 U 0.38 J 1.3 U
0.46 U 0.95 U 1.2 J 1.1 J 0.095 U 0.48 U 0.85 U 1.6 J
5.8 2.7 J 0.41 J 5.5 4.4 J 2.6 J 1.3 U
0.46 U 0.95 U 1.2 J 1.1 J 0.095 U 0.48 U 0.85 U 1.7 J
5.9 2.8 J 0.47 J 5.9 5.0 2.6 J l .3 u
0.46 I 0.95 l 1.1 * 0.76. 0.30. 0.48 I 0.85 l 1.2 J 4.1 J 1.8 J 0.56.
7.1 4.4 J 1.4 J 1.3 u
% Recovery % Recovery % Recovery % Recovery % Recovery % Recovery % Recovery % Recovery % Recovery
98 73 94 100 75 60 48* 71 70
78 86 97 77 94 87 83 79 95 89 90 93 98 91 94
55 11* 68 66 68 58 74 71 72 74 68 80 74 70 73
78 86 93 82 85 90 88 92 105 90 102 100 105 107 112
100 100 100 100 100 100 100 100 100 100 100 100 100 100 100
62 75 71 72 75 65 80 77 83 82 73 86 84 79 82
55 43* 56 47* 68
56 46* 48* 56
52 41* 48* 56 42* 49*
54 47* 60 49* 68
56 47* 39* 49* 52 44* 46* 47* 42* 40*
60 03 74 60 75 75 64 60 70 74 63 64 71 61 68
71 75 83 81 85 76 89 82 81 91 83 82 96 86 87
mV Standard Units
c uS/cm mg/L NTU Observation Observation
NA NA NA NA NA NA Clear None
188 NA 21.5 37 4.8 0 Clear None
151 7.01 21.1 177 3.9
2 Clear None
NA 5.88 21.2 44 7.0
0 Clear None
511 7.01 21.2 110 6.9
0 Clear None
340 5.53 21.0 91 4.8
0 Clear None
NA 6.64 20.3 34 4.8
0 Clear None
NA 5.77 222 100 4.5
0 Clear None
NA 719 21.3 228 3.2
2 Clear None
346 5.83 24.3 40 3.4
0 Clear None
785 7.21 23.1 40 0.2
0 Clear None
NA 5.38 22.3 71 5,8
0 Clear None
483 7.15 21 7 180 3.9
0 Clear None
NA 571 22.0 107 7.3
1 Clear None
604 7.10 21,8 187 5.4
1 Clear None
471 6.08 21.9 109 3.6
0 u
Clear N cxP
-- 1----------Units
-- Standard
--
Raw
Treated
------- --
*
Raw
Treated |
......
Raw
Treated |
Raw
~1 Treated |
.***
Raw
Treated
a.,% *. i %r
Raw
Treated
Raw
Treated
Ran
ng/L ng/L ng/L ng/L ng/L ng/L ng/L ng/L ng/L ng/L ng/L ng/L ng/L ng/L ng'l
0.46 U 0.95 U 0.020 U 0.17 J 0.095 U 0.48 U 0.85 U 0.081 U 0*12 J 0.18 J 0.12 U 0.19 J 0.066 U 0.14 J 13
0.46 U 0,95 U
44 32 0.19 J 1.1 J 0.85 U 46 170 120 7.3 220 39 96 13 U
0.46 U 0.95 U
45 33 0.14 J 0.79 J 0.85 U 51 180 130 7.6 240 42 100 13 U
0.46 U 0.95 U
8.4 4.1 J 0.13 J 0.48 U 0.85 U 9.4
64 24 20 11 23
h
13 0
0.46 0.95 U
8.7 4.3 J 0.11 J 0.48 U 0.85 U 9.3
64 23 22 11 24 11 13U
0.46 U 0.95 U 5.0 J 2.9 J 0.48 J 1.0 J 1.1 J
6.5 34 14 58 32 14 7.8 2.2 J
0.46 U 0.95 U 4.8 J 2.9 J 0.34 J 0.54 J 1.0 J
6.0 31 14 54 30 15 8.0 13U
0.46 U 0.95 U
5.8 5.0 0.13 J 0.83 J 0.85 U 16 55 26 140 150 38 13 3.1 J
0.46 U 0.95 U 0.29 3
6.7 0.57 J 0.62 J 1.3 J 0.32 J 0.30 J 0.95 J 0.56 J 0.77 J 0.45 J 3.3 J 1.9 J
0.46 U 0.95 U 1.6 J 1.3 J 0.49 J 0.48 U 0.87 J 3.1 J
7.5 4.8 J 0.61 J 5.9 7.9 3.7 J 3J
0.46 U 0.95 U 0.029 U 0.21 J 0.13 J 0.48 U 0.85 U 0.081 U 0.12 J 0.11 J 0.12 U 0.20 J 0.22 J 0.20 J 1.3 C
0.46 U 0.95 U 0.25 J 0.29 J 0.75 J 1.0 J 1.2 J 0.29 J 0.59 J 0.50 J 0.63 J 1.7 J 1.8 J 0.44 J
1.6 J
0.46 U 0.95 U 0.38 J 0.33 J 0.25 J 0.49 J 0,85 U 0.37 J 0.65 J 0.71 J 0.34 J 1.2 J 2.1 J 0.56 J 1,3 U
0.46 U 0.95 U 0.81 J 0.80 J 0.17 J 0.48 U 0.85 U 1.6 J 3.2 J 2.3 J 0.66 J
5.9 3.2 J 2.1 J 1.3 J
0,46 U 0.95 U 0.67 J 0.81 J 0.12 J 0.48 U 0.85 U 1.3 J 3.5 J 2.1 J 0.57 J
s.a 3.6 J 2.1 J 1.3 V
0.46 0.95 0.68 0.38 030. 0.48 0.85 0.71 4.5. 1.2. 0.45 4.3. 1.9.. 0.98. 1.3 .
% Recovery
110
95
91
78
80 81
107 96
97 90
96 103 81 82
89
86
% Recovery
89
104 111
91
85 SO 107 96 113 97 94
84 77 74
97
86
% Recovery
110
113
121
93
102 107 116 118 120 104 116 120 95
97
103 102
% Recovery
100
100
100
100 100 100
100
100 100 100
100
100 100 100
100
100
% Recovery
94
105 109 89
90
87
109 103 115 101 101
88
86
79
101
86
% Recovery
81
61
58 49* 44* 34* 64 63 56 54 58
77 4 4 * 50 45* 46*
% Recovery
52
62
67
67
64 51
66
79 67
69
68
97
58 59 47* 52
% Recovery
83
92
87 74
78 75
98 101 93 89
92 117 75 84 90
93
% Recovery
88
118 118 106 100 110 129 121 118 120 118 112 109 104 113 105
mV
Standard Units
c
uS/cm -
mg/L
NTU
Observation
Observation
NA NA NA NA NA NA Clear None
441 6.69 22.3 83 6.8
0 Clear None
402 7.Q0 19.7 179 6.8
1 Clear None
322 5.36 22.0 44 9.1
0 Clear None
564 710 21.4 130 5.7
1 Clear None
481 6.17 22.0 50 7.6
0 Clear None
655 6.90 22.0 107 7.3
0 Clear None
539 5.90 22.1 60 7.0
0 C le a r None
630 7,27 20.4 157 3.5
1 Clear None
NA 6.83 22.2 78 6.6
0 Clear None
639 6.90 21 7 160 5.9
0 Clear None
379 8.33 21.3 64 5.2
0 Clear None
654 7.24 20.3 110 5.8
0 Clear None
377 5,46 22.1 59 6.2
0 Clear None
607 7.10 22 1 102 6,8
1 Clear None
364 6.90 21.8 59 7.2
0 _____ x
Clea^ None
Notes: ng/L U
J * mV C
Nanograms per liter (parts per trillion). The analyte was analyzed for, but w as not c
The result is an estimated value that was dr The result is an outlier. See case narrative. Millivolts. Donroo Poloiiic
p. 12
%
Baron & Budd, P.C.
Emerald Coast Utilities Authority Production Well Sampling Escambia County, Florida
ECUA Production Well Location Map
Appendix A
A ppendix B
Baron & Budd, P.C.
Emerald Coast Utilities Authority Production Well Sampling Escambia County, Florida
Sample Port Photograph Log
Appendix B
Baron & B u d d , P.C, (Dallas, Texas)
ECUA Production Well Sampling - February 1 , 2010
Escam bia County, Florida
Ellyson-Raw Sampling Port
Ellyson-Treated Sampling Port
ll d
Baron & B ud d, P.C. {Dallas, Texas) EtU Production Well Sampling - February 1, 2010
Escambia County, Florida
Davis-Raw Sampling Port
Davis-Treated Sampling Port
B aron & B u d d , P.C. (Dallas, Texas) EC U A P ro d u ctio n Well S a m p lin g - F e b ru ary 1, 2010
Escam bia County, Florida
Olive-Raw Sampling Port
Olive-Treated Sampling Port
Baron & B u d d, P.C. (Dallas, Texas)
E C U A P ro d u ctio n W e ll S a m p lin g - Fe b ru a ry 1, 2010
Escam bia County, Florida
Carriage Hills-Raw Sampling Port
Carriage Hills-Treated Sampling Port
Baron & B u d d , P.C. (Dallas, Texas)
E C U A P ro d u ctio n W e ll S a m p lin g - F e b ru a ry 1, 2010
Escam bia County, Florida
Watson-Raw Sampling Port
Watson-Treated Sampling Port
B aron & B u d d, P.C. (Dallas, Texas)
EC U A Production Well S a m p lin g - Feb ru ary 1, 2010
Escam bia County, Florida
Kingsfield Road-Raw Sampling Port
Kingsfield Road-Treated Sampling Port
Baron & Budd, P.C. (Dallas, Texas! EC U A P ro d u ctio n W e ll S a m p lin g - F eb ru ary 1, 2010
Escam bia County, Florida
Cantonment-Raw Sampling Port
Cantonment-Treated Sampling Port
B aron & B u d d, P.C. (Dallas, Texas)
E C U A P ro d u ctio n W e ll S a m p lin g - F eb ru ary 1, 2010
Escambia County, Florida
Nine Mile Road-Raw Sampling Port
Nine M ile Road-Treated Sampling Port
Baron & Budd, P .C (Dallas, Texas) EC U A P ro d u ctio n W e ll S a m p lin g - F e b ru a ry 2, 2010
Escam bia County, Florida
University Parkway-Raw Sampling Port University Parkway-Treated Sampling Port
Baron & B u d d , P.C. (Dallas, Texas) EC U A P ro d u ctio n W ell S a m p lin g - F e b ru a ry 2, 2010
Escam bia County, Florida
McCory-Raw Sampling Port
McCory-Treated Sampling Port
p. 26
Baron & B u d d, P.C. (Dallas, Texas) ECU A Production Well Sam plin g - Feb ru ary 2, 2010
Escam bia County, Florida
p. 27
Baron & Budd, P .C (Dallas, Texas) ECUA Production W ell Sam pling - February 2, 2010
Escam bia County, Florida
Lillian-Raw Sampling Port
Lillian-Treated Sampling Port
9>
CV| Q.
B aron & B u d d , P.C. (Dallas, Texas)
ECU A P rodu ction W ell Sam pling - February 2, 2010
Escam bia County, Florida
Bronson-Raw Sampling Port
Bronson-Treated Sampling Port
Baron & Budcf, P ,C (Dallas, Texas) ECUA P ro d u ctio n Well Sampling - February 2, 2010
Escam bia County, Florida
West Pensacola-Raw Sampling Port
West Pensacola-Treated Sampling Port
B aro n & B u d d , P.C. (D allas, Texas) EC U A P ro d u c tio n W ell Sampling - February 2, 2010
Escam bia County, Florida
p. 32
f:
Baron & Budd, P.C (Dallas, Texas) ECUA Production W ell Sam pling - February 2, 2010
Escam bia County, Florida
West Well Plant-Raw Sampling Port
West Well Plant-Treated Sampling Port
p. 33
Baron & Budd, P.C. (Dallas, Texas) EC U A P ro d u c tio n W ell S a m p lin g - Feb ru ary 2, 2010
Escam bia County, Florida
"F" & Scott-Raw Sampling Port
"F" & Scott-Treated Sampling Port
Baron & B u d d , P.C. (Dallas, Texas)
EC U A P ro d u c tio n W ell S a m p lin g - Feb ru ary 2 , 2010
Escam bia County, Florida
m\\ \\i
No. 6 Well Plant-Raw Sampling Port
No. 6 Well Plant-Treated Sampling Port
Baron & Budd, RC. (Dallas, Texas) ECUA P ro d u ctio n W ell Sam pling - February 3, 2010
Escambia County, Florida
Hagler Well Plant-Raw Sampling Port
Hagler Well Plant-Treated Sampling Port
Baron & Budcf, P.C. (Dallas, Texas) EC U A P ro d u ctio n W ell S a m p lin g - Feb ru ary 3, 2010
Escam bia County, Florida
Spanish Trail-Raw Sampling Port
Spanish Trail-Treated Sampling Port
Baron & Budd, RC. (Dallas, Texas) ECU A P ro d u ctio n W e ll S a m p lin g - February 3, 2010
Escam bia County, Florida
Airport North-Raw Sampling Port
Airport North-Treated Sampling Port
Baron & B ud d, P.C. (Dallas, Texas)
ECUA Production W ell Sam pling - February 3, 2010 Escambia County, Florida
McAllister-Raw Sampling Port
McAllister-Treated Sampling Port
Baron & B udd, P.C. (Dallas, Texas)
ECU A Produ ction W e ll Sam pling - February 3, 2010 Escambia County, Florida
Humphrey's-Raw Sampling Port
Humphreys-Treated Sampling Port
Baron & B u d d , P.C. (D allas, Texas) ECU Production W ell Sam pling - February 3, 2010
Escam bia County, Florida
Broad Street-Raw Sampling Port
Broad Street-Treated Sampling Port
Baron & B ud d, P.C. (D allas, Texas)
EC U A P ro d u ctio n W e ll S a m p lin g - F e b ru a ry 3, 2010
Escam bia County, Florida
Tennant-Raw Sampling Port
Tennant-Treated Sampling Port
p. 42
Baron & Budd, RC, (Dallas, Texas) ECUA Production Well S a m p lin g - February 3, 2010
Avondale-Temporarily Inactive
B aron & B u d d , P.C. (Dallas, Texas) ECU A Produ ction W ell Sam pling - February 3, 2010
Escam bia County, Florida
Muldoon-Raw Sampling Port
Muldoon-Treated Sampling Port
B aron & B u d d , P.C. (Dallas, Texas) ECU A P ro d u ctio n W ell Sam pling - February 3, 2010
Escam bia County, Florida
Villa Drive-Raw Sampling Port
Villa Drive-Treated Sampling Port
B aro n & B u d d , P.C. (Dallas, Texas) EC U A P ro d u ctio n W e ll S a m p lin g - F eb ru ary 3, 2010
Escam bia County, Florida
Royce Street-Raw Sampling Port
Royce Street-Treated Sampling Port
p. 46
Baron & Budd, R C (Dallas, Texas) ECUA Production Well S a m p lin g - February 3, 201
Escambia County, Florida
Ensley-Permanently Inactive
p. 47
o d iu n m DuCiU; r .c . (u a iid b , le xa b j
ECUA P ro d u ctio n Well Sampling - February 3#2010 Escambia County, Florida
Sweeny-Temporarily Inactive
B aron & B u d d , P.C. (Dallas, Texas) EC U P ro d u c tio n W e ll S a m p lin g - Feb ru ary 3, 2010
Escam bia County, Florida
OLF 4 A-Temporarily Inactive
(Well Screen Extraction)
OLF 4 A-Temporarily Inactive
(Inactive Motor)
OLF 4 A-Temporarily Inactive
(Drill Rig/Well Screen Extraction)
Appendix C
9>
Q.
Baron & Budd, P.C.
Emerald Coast Utilities Authority Production Well Sampling Escambia County, Florida
Groundwater Sample Logs/Field Calibration Logs
Appendix C
GROUNDWATER SAMPLING LOG
p. 51
I SITE I NAME: ECUA Water Distribution System (Countv-wide)
SITE LOCATION: Escambia Countv, Florida
'ELL NO: / l y f a *
SAM PLE ID:
DATE: February / , 2010
PURGING DATA
WELL CASING
-7
TUBING
WELL SCREEN INTERVAL
PUMPING WATER
PURGE PUMP TYPE:
DIAMETER (inches): Y C l
DIAMETER (inches): NA
DEPTH:
UNK
LEVEL (feet): UNK
Existing Pump
W ELL VOLUME PURGE: 1 W ELL VOLUME = (TOTAL WELL DEPTH - STATIC DEPTH TO WATER) X WELL CAPACITY
(only fill out if applicable) gallons
--
= ( 3 -f 0
feet -
UNK
feet) X
gallons/foot
EQUIPMENT VOLUM E PURGE: 1 EQUIPMENT VOL. = PUMP VOLUME + (TUBING CAPACITY X TUBING LENGTH) + FLOW CELL VOLUME
(only fill out If applicable)
= gallons + (
gallons/foot X
feet) +
gallons
gallons
PU M P DEPTH IN W ELL (feet): UNK
TIME (CST)
VOLUME PURGED (gallons)
CUMUL. VOLUME PURGED (gallons)
6 ? -S3
/o me
FINAL PUMP DEPTH IN W ELL (feet): UNK
PURGING
c
INITIATED AT: u 7 `T->
PURGING ENDED AT:
PURGE RATE (gpm)
ORP (mV)
pH (standard
units)
TEMP. (C)
5: u S.iol
a.{.2 -2/.7T MS
COND. (gS/cm)
& &C o
DISSOLVED OXYGEN (mg/L)
7-2- Z3Z.
J..3I
TOTAL VOLUME PURGED (gallons):
TURBIDITY (NTUs)
COLOR (describe)
Clear Clear Clear
ODOR (describe)
None None None
W ELL C A PA C IT Y (Gallons Per Foot): 0.75" 0.02; 1" = 0.04; 1.25" =0.06; 2 " = 0.16; 3" = 0.37; 4" 0.65; 5"=1.02; 6" 1.47; 12" 5.88
TUBING INSIDE DIA. CA PA CIT Y (GaliFt.): 1/8" = 0.0006; 3/16* =0.0014; 1/4" = 0.0026; 5/16" =0.004;
3/8" = 0.006; 1/2" = 0.010; 5/8" = 0.016
PURGING EQUIPM ENT CODES: B = Bailer; B P = Bladder Pump;
E S P = Electric Submersible Pump;
P P = Peristaltic Pump; O = Other (Specify)
SAMPLING DATA
SAM PLED BY (PRINT) /AFFILIATION: David L. Anderson/CDM
SA^PLERjS) ^|GNATURE(S):
SAMPLING
.
INITIATED AT: / O i
SAMPLING ENDED AT:
PU M P DEPTH IN W E LL (feet): UNK
FIELD DECONTAMINATION:
PUMP: No
TUBING MATERIAL CODE: NA
TUBING: NA
FIELD-FILTERED: No Filtration Equipment Type:
DUPLICATE:
NA
FILTER SIZE: No
NA
urn
SAMPLE CONTAINER SPECIFICATION
SAMPLE ID CODE
NA
# CONTAINERS
2
MATERIAL CODE
PE
VOLUME 1liter
SAMPLE PRESERVATION
PRESERVATIVE USED
None
TOTAL VOL ADDED IN FIELD (mL)
None
FINAL PH NA
INTENDED ANALYSIS AND/OR
METHOD
PFOA, PFOS, &
SAMPLING EQUIPMENT
CODE
O-Grab
SAMPLE PUMP FLOW RATE
(mL per minute)
<100 mL
Fluorinated Cmps
by HPLC/MS.
REMARKS: NA - Not Applicable.
UNK - Unknown.
Was the well pumping (active) prior to sampling ^ Y e|) or No.
MS/MSD sample collected - Yes o^ Ni> ) Collection Time:
Well has fluoride treatment - Yes or No.
Photograph No. /
CAjVrvjMATERIAL CODES:
A G =Amber Glass; C G =Clear Glass;
Fio\& SltmK. I C<s/lacf^A /y4P E =Polyethylene; P P =Polypropylene; S = Silicone; T = Teflon; O =Other (Specify)
'AM PLIN G EQUIPMENT CODES: A P P = After Peristaltic Pump;
B = Bailer; B P = Bladder Pump; E S P = Electric Submersible Pump;
R FPP = Reverse Flow Peristaltic Pump; SM = Straw Method (Tubing Gravity Drain); O = Other (Grab)
NOTES: 1. The above do not constitute all of the Information required by Chapter 62-160, F.A.C.
2. S tabilization C riteria for ran ge o f variation o f last three co n secutive readings (see FS 2212. section 3)
pH: + 0.2 units Temperature: + 0.2 C Specific Conductance: +5% Dissolved Oxygen: all readings < 20% saturation (see Table FS 2200-2); optionally, + 0.2 mg/L or + 10% (whichever is greater) Turbidity: all readings < 20 NTU; optionally + 5 NTU or + 10% (whichever is greater)
Revision Date: February 12, 2009
GROUNDWATER SAMPLING LOG
p. 52
I SITE I NAME: ECUA Water Distribution System (Countv-wide)
SITE LOCATION: Escambia Countv, Florida
ELL NO: / ! y J ^
SAM PLE ID:
DATE: February / ,2010
PURGING DATA
WELL CASING
,
DIAMETER (inches): ^ G
TUBING DIAMETER (Inches): NA
WELL SCREEN INTERVAL
DEPTH:
UNK
PUMPING WATER LEVEL (feet): UNK
PU RGE PUMP TYPE: Existing Pump
W ELL VOLUME PURGE: 1 W ELL VOLUME = (TOTAL W ELL DEPTH - STATIC DEPTH TO WATER) X WELL CAPACITY
(only fill out if applicable)
=( 3 ? 0
feet-
UNK
feet) X
gallons/foot =
gallons_________________________________________ [____________________________________ _________________________________ ________
EQUIPMENT VOLUM E PURGE: 1 EQUIPMENT V O L = PUM P VOLUME + (TUBING CAPACITY X TUBING LENGTH) + FLOW CE LL VOLUME
(only fill out Ifapplicable)
gallons + (
gallons/foot X
feet) +
gallons =
gallons
PUMP DEPTH IN W ELL (feet): UNK
TIME (CST)
VOLUME PURGED (gallons)
CUMUL. VOLUME PURGED (gallons)
/ooj
//
/O 13
FINAL PUMP DEPTH IN W ELL (feet): UNK
PURGING INITIATED AT: / G O O
PURGE RATE
(gpm)
ORP (mV)
/8s /7c
/?*
pH (standard
units)
TEMP. (C)
i.o / -21
-z-./y Z l . N
? .o 8 /. 0
COND. (pS/cm) tfc
/ r0
PURGING ENDED AT:
DISSOLVED OXYGEN (mg/L)
% .v
TOTAL VOLUME PURGED (gallons):
TURBIDITY (NTUs)
O O
COLOR (describe)
Clear Clear Clear
ODOR (describe)
None None None
./ELL CAPACITY (Gallons Per Foot): 0.75" =0.02; 1" =0.04; 1.25" =0.06; 2" =0.16; 3" =0.37; 4" =0.65; 5" = 1.02; 6" = 1.47; 12" =5.88 TUBING INSIDE DIA. CAPACITY (Gal /FL): 1/8" =0.0006; 3/16" =0.0014; 1/4" =0.0026; 5/16" =0.004; 3/8" =0.006; 1/2" =0.010; 5/8" =0.016
PURGING EQUIPMENT CODES: B = Bailer;
SAM PLED B Y (PRINT) / AFFILIATION: David L. Anderson/CDM
B P = Bladder Pump;
E SP = Electric Submersible Pump; P P = Peristaltic Pump;
SAMPLING DATA
SAMPLER(S) SIGNATURE(S):
SAMPLING
.
INITIATED AT: / G / 5
O = Other (Specify)
SAMPLING ENDED AT:
PUM P DEPTH IN W ELL (feet): UNK
TUBING MATERIAL CODE: NA
FIELD-FILTERED: No
FILTER SIZE: NA urn
Filtration Equipment Type: NA
FIELD DECONTAMINATION:
PUMP: No
TUBING: NA
DUPLICATE:
No
SAMPLE CONTAINER SPECIFICATION
SAMPLE ID CODE
NA
# CONTAINERS
2
MATERIAL CODE
PE
VOLUME I liter
SAMPLE PRESERVATION
PRESERVATIVE USED None
TOTAL VOL ADDED IN FIELD (mL)
None
FINAL PH NA
INTENDED ANALYSIS AND/OR
METHOD
PFOA, PFOS, &
Fluorinated Cmps
SAMPLING EQUIPMENT
CODE
O-Grab
SAMPLE PUMP FLOW RATE
(mL per minute)
<100 mL
by HPLC/MS.
REMARKS: NA - Not Applicable.
UNK - Unknown.
Was the well pumping (active) prior to sampling^Ye>5? o r No.
MS/MSD sample collected - Yes oiCTncl) Collection Time:
Well has fluoride treatment - Yes or No.
Photograph No. . 2 .
C-Aj-Yny
MATERIAL CODES:
A G = Amber Glass; CG = Clear Glass; PE = Polyethylene; PP = Polypropylene; S =Silicone; T =Teflon; O = Other (Specify)
\MPLING EQUIPMENT CODES:
A P P =After Peristaltic Pump;
B = Bailer; B P = Bladder Pump; E SP = Electric Submersible Pump;
RFPP = Reverse Flow Peristaltic Pump; SM = Straw Method (Tubing Gravity Drain); O = Other (Grab)
NOTES: 1. The above do not constituteall of the Information required by Chapter 62-160, F.A.C.
2. STABILIZATIO N C R IT E R IA FO R RANGE O F VARIATION O F LA ST TH R E E C O N SEC U TIV E READIN G S (S E E F S 2 2 1 2 . SECTIO N 3)
pH: +0 .2 units Temperature: +0 .2 C Specific Conductance: +5% Dissolved Oxygen: all readings < 2 0 % saturation (see Table FS 2 2 0 0 -2 ); optionally, + 0 .2 mg/L or + 1 0 % (whichever is greater) Turbidity: all readings < 2 0 NTU; optionally + 5 NTU or + 1 0 % (whichever is greater)
Revision Date: February 12, 2009
GROUNDWATER SAMPLING LOG
p. 53
I SITE I NAME: ECUA Water Distribution System (County-wide)
SITE LOCATION: Escambia County, Florida
LLN0: P a i x T
SAM PLE ID:
J
PURGING DATA
DATE: February / , 2010
WELL CASING
, TUBING
WELL SCREEN INTERVAL
PUMPING WATER
PU RG E PUMP TYPE:
DIAMETER (inches); LP DIAMETER (inches): NA
DEPTH:
UNK
LEVEL (feet): UNK
Existing Pump
W ELL VOLUME PURGE: 1 W ELL VOLUME = (TOTAL WELL DEPTH - STATIC DEPTH TO WATER) X WELL CAPACITY
(only fill out If applicable) aallons
=(
feet-
UNK
feet) X
gallons/foot =
EQUIPMENT VOLUME PURGE: 1 EQUIPMENT VOL. = PUM P VOLUME + (TUBING CAPACITY X TUBING LENGTH) + FLOW C E LL VOLUME
(only fill out if applicable)
= gallons + (
gallons/foot X
feet) +
gallons =______ gallons
PUM P DEPTH IN W ELL (feet): UNK
TIME (CST)
VOLUME PURGED (gallons)
CUMUL. VOLUME PURGED (gallons)
/o 3?
/ c > 3 (o
FINAL PUMP DEPTH IN W ELL (feet): UNK
PURGING
,?
INITIATED AT: / O J O
PURGE RATE (gpm)
ORP (mV)
x sz -2 8<f
pH (standard
units)
TEMP. (C)
-- 2/(>
Zl- k ? -- -2- / - U
COND. (pS/cm)
*?-/
PURGING ENDED AT:
DISSOLVED OXYGEN (mg/L)
y .n
H -n 4 /. / (p
TOTAL VOLUME PURGED (gallons):
TURBIDITY (NTUs)
COLOR (describe)
ODOR (describe)
c>
Clear
None
Clear
None
Clear
None
WELL CAPACITY (Gallons Per Foot): 0.75" = 0.02; 1" = 0.04; 1.25" = 0.06; 2" = 0.16; 3" = 0.37; 4" = 0.65; 5" =1.02; 6" = 1.47; 1I2" =5.88
TUBING INSIDE DIA. CAPACITY (Gal./Ft.): 1/8" = 0.0006; 3/16" = 0.0014; 1/4" = 0.0026; 5/16" = 0.004:
3/8" = 0.006: 1/2" = 0.010; 5/8" = 0.016
PURGING EQUIPMENT CODES: B = Bailer,
SAM PLED BY (PRINT) / AFFILIATION: David L. Anderson/CDM
BP = Bladder Pump;
ESP = Electric Submersible Pump;
PP = Peristaltic Pump;
SAMPLING DATA
SAMPLER(S) SJGNATURE(S):
SAMPLING
,.
INITIATED AT: / C > Y 0
O = Other (Specify)
SAMPLING ENDED AT:
PU M P DEPTH IN W ELL (feet): UNK
TUBING MATERIAL CODE: NA
FIELD-FILTERED: No
FILTER SIZE: NA
Filtration Equipment Type: NA
urn
FIELD DECONTAMINATION:
PUMP: No
TUBING: NA
DUPLICATE:
No
SAMPLE CONTAINER SPECIFICATION
SAMPLE ID CODE
NA
# CONTAINERS
2
MATERIAL CODE PE
VOLUME I liter
SAMPLE PRESERVATION
PRESERVATIVE USED
None
TOTAL VOL ADDED IN FIELD (mL)
None
FINAL pH
NA
INTENDED ANALYSIS AND/OR
METHOD
PFOA, PFOS, &
Fluorinated Cmps
SAMPLING EQUIPMENT
CODE
O-Grab
SAMPLE PUMP FLOW RATE
(mL per minute)
<100 mL
by HPLC/MS.
REMARKS: NA - Not Applicable.
Was the well pumping (active) prior to sampling^Ye^) or No.
Well has fluoride treatment - Yes or No. /
UNK - Unknown. MS/MSD sample collected - Yes or ('No?) Collection Time: Photograph No. ^
MATERIAL CODES:
AG = Amber Glass; CG = Clear Glass; PE = Polyethylene; PP = Polypropylene; S = Silicone; T =Teflon; O = Other (Specify)
' MPLING EQUIPMENT CODES: APP = After Peristaltic Pump:
B = Bailer; BP = Bladder Pump; ESP = Electric Submersible Pump;
RFPP = Reverse Flow Peristaltic Pump; SM = Straw Method (Tubing Gravity Drain); O = Other (Grab)
NOTES: 1. The above do not constitute all of the Information required by Chapter 62-160, F.A.C.
2. Stabilization Criteria for range of variation of last three consecutive readings (see F S 2212. section 3)
pH: + 0.2 units Temperature: + 0.2 C Specific Conductance: +5% Dissolved Oxygen: all readings <20% saturation (see Table FS 2200-2); optionally, + 0.2 m g/Lor + 10% (whichever is greater) Turbidity: all readings < 20 NTU; optionally + 5 NTU or + 10% (whichever is greater)
Revision Date: February 12, 2009
GROUNDWATER SAMPLING LOG
p. 54
I SITE I NAME: ECUA Water Distribution System (Countv-wide)
SITE LOCATION: Escambia County, Florida
ILL NO:
SAM PLE ID:
DATE: February / ,2010
PURGING DATA
WELL CASING
. TUBING
WELL SCREEN INTERVAL
PUMPING WATER
PURGE PUMP TYPE:
DIAMETER (inches):
DIAMETER (inches): NA
DEPTH:
UNK
LEVEL (feet): UNK
Existing Pump
W ELL VOLUME PURGE: 1 W ELL VOLUME = (TOTAL WELL DEPTH - STATIC DEPTH TO WATER) X WELL CAPACITY (only fill out if applicable)
gallons
= ( 2 .S S
feet-
UNK
feet) X
gallons/foot =
EQUIPMENT VOLUME PURGE: 1 EQUIPMENT VOL. = PU M P VOLUME + (TUBING CAPACITY X TUBING LENGTH) + FLOW CELL VOLUME (only fill out if applicable)
= gallons + (
gallons/foot X
feet) +
gallons =
gallons
PUMP DEPTH IN W ELL (feet): UNK
TIME (CST)
VOLUME PURGED (gallons)
CUMUL. VOLUME PURGED (gallons)
/C. 7 2
/o</7
FINAL PUMP DEPTH IN W ELL (feet): UNK
PURGE RATE
(gpm)
ORP (mV)
38/ 372
pH (standard
units)
? // ?J(
T fS
7 -/ 2
PURGING
PURGING .
INITIATED AT: / 0 3 2 . ENDED AT: /> < //
TOTAL VOLUME PURGED (gallons):
TEMP. (C)
CONO. (pS/cm)
DISSOLVED OXYGEN (mg/L)
TURBIDITY (NTUs)
COLOR (describe)
ODOR (describe)
/-C2
/<?.>( /?oo
/a ?
/?* Z72.
*.4 7 <r. a / r .tj
/ O
O
Clear Clear Clear
None None None
.<LL CAPACITY (Gallons Per Foot): 0.75" = 0.02; 1" = 0.04; 1.25" = 0.06; 2" = 0.16; 3" = 0.37; 4" = 0.65; 5" =1.02; 6" = 1.47; 12" = 5.88 TUBING INSIDE DIA. CAPACITY (GaL/FL): 1/8" = 0.0006; 3/16" = 0.0014; 1/4" = 0,0026; 5/16" =0.004; 3/8" = 0.006; 1/2" = 0,010; 5/8" = 0.016
PURGING EQUIPMENT CODES: B = Bailer; BP = Bladder Pump;
ESP = Electric Submersible Pump;
PP = Peristaltic Pump;
O = Other (Specify)
SAMPLING DATA
SAM PLED B Y (PRINT) / AFFILIATION: David L. Anderson/CDM
SA'MPLER(S) SJGNATURE(S):
SAMPLING INITIATED AT: /C > 5 2 .
SAMPLING ENDED AT:
PUMP DEPTH IN W ELL (feet): UNK
FIELD DECONTAMINATION:
PUMP: No
TUBING MATERIAL CODE: NA
TUBING: NA
FIELD-FILTERED: No Filtration Equipment Type:
DUPLICATE:
NA
FILTER SIZE: No
NA
urn
SAMPLE CONTAINER SPECIFICATION
SAMPLE ID CODE
NA
# CONTAINERS
2
MATERIAL CODE PE
VOLUME 1liter
SAMPLE PRESERVATION
PRESERVATIVE USED
None
TOTAL VOL ADDED IN FIELD (mL)
None
FINAL pH NA
INTENDED ANALYSIS AND/OR
METHOD
PFOA, PFOS, &
SAMPLING EQUIPMENT
CODE
O-Grab
SAMPLE PUMP FLOW RATE
(mL per minute)
<100 mL
Fluorinated Cmps
by HPLC/MS.
REMARKS: NA - Not Applicable.
UNK - Unknown.
Was the well pumping (active) prior to sampling ^ Y ej) or No.
MS/MSD sample collected - Yes a^ N g )C o lle ctio n Time:
Well has fluoride treatment - Yes or No.
Photograph No. 2j,
CA f-'A j
/o '
MATERIAL CODES:
AG =Amber Glass; CG = Clear Glass; PE = Polyethylene; PP = Polypropylene; S = Silicone; T = Teflon; O = Other (Specify)
'MPUNG EQUIPMENT CODES:
APP = After Peristaltic Pump;
B = Bailer; BP = Bladder Pump; ESP = Electric Submersible Pump;
RFPP = Reverse Flow Peristaltic Pump; SM = Straw Method (Tubing Gravity Drain); O = Other (Grab)
NOTES: 1. The above do not constitute all of the information required by Chapter 62-160, F.A.C. 2. S t a b i l i z a t i o n C r i t e r i a f o r r a n g e o f v a r i a t i o n o f l a s t t h r e e c o n s e c u t i v e r e a d i n g s (s e e FS 2212, s e c t i o n 3)
pH: + 0.2 units Temperature: + 0.2 C S p e c ific C o ndu ctance: +5% D isso lve d Oxygen: all readings < 20% saturation (see Table FS 2200-2); optionally, + 0.2 mg/L or + 10% (whichever is greater) Turbidity: all readings < 20 NTU; optionally + 5 NTU or + 10% (whichever is greater)
Revision Date: February 12, 2009
GROUNDWATER SAMPLING LOG
p. 55
SITE NAME: ECUA Water Distribution System (County-wide)
SITE LOCATION: Escambia County, Florida
ELL NO:
SAMPLE ID:
DATE: February / ,2010
PURGING DATA
WELL CASING
DIAMETER (Inches): 2 4
TUBING DIAMETER (Inches): NA
WELL SCREEN INTERVAL
DEPTH:
UNK
PUMPING WATER LEVEL (feet): UNK
PURGE PUMP TYPE: Existing Pump
WELL VOLUME PURGE: 1 WELL VOLUME = (TOTAL W ELL DEPTH - STATIC DEPTH TO WATER) X WELL CAPACITY
(only fill out if applicable)
. = ( 2 O [g
feet-
UNK
feet) X
gallons/foot =
gallons EQUIPMENT VOLUME PURGE: 1 EQUIPMENT VOL. = PUM P VOLUME + (TUBING CAPACITY
X
TUBING LENGTH) + FLOW CELL VOLUME
(only fill out If applicable)
= gallons + (
gallons/foot X
feet)+
gallons =
gallons
PU M P DEPTH IN W ELL (feet): UNK
TIME (CST)
VOLUME PURGED (gallons)
CUMUL. VOLUME PURGED (gallons)
//> Q>
/A> 7 /f/2 .
FINAL PUMP DEPTH IN W ELL (feet): UNK
PURGING
,7
INITIATED AT: / / J
PURGE RATE (gpm)
ORP (mV)
-2 7 / 2 -7 1
pH (standard
units)
TEMP. (C)
S -J ! r.7 o 5 -.7 2 _
-Z -A 'cyf
COND. (pS/cm)
I? 77 ? (o
PURGING ENDED AT:
DISSOLVED OXYGEN (mg/L)
(o- 75*
L- ? 4 (0 - <7 S
TOTAL VOLUME PURGED (gallons):
TURBIDITY (NTUs)
/
1
COLOR (describe)
Clear Clear Clear
ODOR (describe)
None None None
.,ELL CAPACITY (Gallons Per Foot): 0.75" = 0.b2; 1" = 0.04; 1.26" -0.06; 2" = 0.16; 3" = 0.37; 4" = 0.65; 5" = 1.02; 6" =1.47; 12" = 5.88
TUBING INSIDE DIA. CAPACITY (Qal./Ft.): 1/8" = 0.0006; 3/16" = 0.0014; 1/4" = 0.0026; 5/16" = 0.004;
3/8" = 0.006; 1/2" = 0.010; SIB" =0.016
PURGING EQUIPMENT CODES: B = Bailer; BP = Bladder Pump;
ESP = Electric Submersible Pump;
PP = Peristaltic Pump;
O = Other (Specify)
SAMPLING DATA
SAM PLED BY (PRINT) / AFFILIATION: David L. Anderson/CDM
SAWPLERfS) SO^NATURE(S):
SAMPLING
_
INITIATED AT: / I S
SAMPLING ENDED AT:
PU M P DEPTH IN W ELL (feet): UNK
TUBING MATERIAL CODE: NA
FIELD-FILTERED: No
FILTER SIZE: NA
Filtration Equipment Type: NA
um
FIELD DECONTAMINATION:
PUMP: No
TUBING: NA
DUPLICATE:
No
SAMPLE CONTAINER SPECIFICATION
SAMPLE ID CODE
NA
# CONTAINERS
2
MATERIAL CODE
PE
VOLUME 1liter
SAMPLE PRESERVATION
PRESERVATIVE USED
None
TOTAL VOL ADDED IN FIELD (mL)
None
FINAL pH NA
INTENDED ANALYSIS AND/OR
METHOD
PFOA, PFOS, &
Fluorinated Cmps
SAMPLING EQUIPMENT
CODE
O-Grab
SAMPLE PUMP FLOW RATE
(mL per minute)
<100 m L
by HPLC/MS.
REMARKS: NA - Not Applicable.
UNK - Unknown.
Was the well pumping (active) prior to sampling ^ Yes^ or No.
MS/MSD sample collected - Yes or ( no^ Collection Time:
Well has fluoride treatm ent-Yes or No.
Photograph No.
C tf)S~'v\) MATERIAL CODES:
I/O . A G =Amber Glass; CG =Clear Glass;
PE =Polyethylene;
PP =Polypropylene; S = Silicone; T =Teflon; O =Other (Specify)
\MPLING EQUIPMENT CODES: APP = After Peristaltic Pump;
B = Bailer; BP = Bladder Pump; ESP = Electric Submersible Pump;
RFPP = Reverse Flow Peristaltic Pump; SM = Straw Method (Tubing Gravity Drain); O =Other (Grab)
NOTES: 1. The above do not constitute all of the information required by Chapter 62-160, F.A.C.
2. STABILIZATIO N C R IT E R IA FO R RAN G E O F VARIATION O F LA S T TH R E E C O N SE C U T IV E READINGS (S E E FS 2 2 1 2 . SECTIO N 3)
pH: + 0.2 units Temperature: 0.2 C Specific Conductance: +5% Dissolved Oxygen: all readings < 20% saturation (see Table FS 2200-2); optionally. + 0.2 mg/L or + 10% (whichever is greater) Turbidity: all readings < 20 NTU; optionally + 5 NTU or + 10% (whichever is greater)
Revision Date: February 12, 2009
GROUNDWATER SAMPLING LOG
P"
SITE I NAME: ECUA Water Distribution System (Countv-wide)
ELL NO: O / iU Q .
SAM PLE ID:
SITE LOCATION: Escambia Countv. Florida
- 7} ^ ^
DATE: February j , 2010
PURGING DATA
WELL CASING
,
DIAMETER (inches): 2 Y
TUBING DIAMETER (inches): NA
WELL SCREEN INTERVAL
DEPTH:
UNK
PUMPING WATER LEVEL (feet): UNK
PURGE PUMP TYPE: Existing Pump
W ELL VOLUME PURGE: 1 W ELL VOLUME = (TOTAL W ELL DEPTH - STATIC DEPTH TO WATER) X WELL CAPACITY
(only fill out if applicable) gallons
= ( 2.0 (p
feet-
UNK
feet) X
gallons/foot =
EQUIPMENT VOLUME PURGE: 1 EQUIPMENT VOL. = PU M P VOLUME + (TUBING CAPACITY
TUBING LENGTH) + FLOW CELL VOLUME
(only fill out if applicable)
= gallons + (
gallons/foot X
feet) +
gallons =
gallons
PUMP DEPTH IN W ELL (feet): UNK
TIME (CST)
VOLUME PURGED (gallons)
CUMUL. VOLUME PURGED (gallons)
///f // o
//2 J
FINAL PUMP DEPTH IN W ELL (feet): UNK
PURGING
.
INITIATED AT: / / 7
PURGE RATE (gpm)
ORP (mV)
-- *---
-----
pH (standard
units)
TEMP. (C)
>JS ,.7 8
-3 8
-2 c .tf?
COND. (pS/cm)
/3 J A/C> /3 %
PURGING ENDED AT: DISSOLVED OXYGEN
(mg/L)
(,.? 2
L . 92.
TOTAL VOLUME PURGED (gallons):
TURBIDITY (NTUs)
COLOR (describe)
ODOR (describe)
3
Clear
None
i
Clear
None
/
Clear
None
VELL CAPACITY (Gallons Per Foot): 0.75" =0.02; 1" = 0.04; 1.25" = 0.06; 2" = 0.16; 3" = 0.37; 4" = 0.65; 5" = 1.02; 6" = 1.47; 12" =5.88 TUBING INSIDE DIA. CA PA CIT Y (Gal./Ft.): 1/8" = 0.0006; 3/16" = 0.0014; 1/4" = 0,0026; 5/16" = 0.004; 3/8" = 0.006; 1/2" = 0,010; 5/8" = 0.016
PURGING EQUIPMENT CODES: B = Bailer;
SAM PLED BY (PRINT) /AFFILIATION: David L. Anderson/CDM
B P = Bladder Pump; E S P = Electric Submersible Pump; PP = Peristaltic Pump;
SAMPLING DATA
SASJPLER(S) SIG^ATURE(S):
SAMPLING
,
INITIATED AT: 1 1 2 . 5
O =Other (Specify)
SAMPLING ENDED AT:
PUM P DEPTH IN W ELL (feet): UNK
TUBING MATERIAL CODE: NA
FIELD-FILTERED: No
FILTER SIZE: NA urn
Filtration Equipment Type: NA
FIELD DECONTAMINATION:
PUMP: No
TUBING: NA
DUPLICATE:
No
SAMPLE CONTAINER SPECIFICATION
SAMPLE ID CODE
NA
# CONTAINERS
2
MATERIAL CODE PE
VOLUME I liter
SAMPLE PRESERVATION
PRESERVATIVE USED None
TOTAL VOL ADDED IN FIELD (mL)
None
FINAL pH
NA
INTENDED ANALYSIS AND/OR
METHOD
PFOA, PFOS, &
SAMPLING EQUIPMENT
CODE
O-Grab
SAMPLE PUMP FLOW RATE
(mL per minute)
<100 mL
Fiuorinated Cmps
by HPLC/MS.
REMARKS: NA - Not Applicable.
UNK - Unknown.
Was the well pumping (active) prior to sampling -^Yes) or No.
MS/MSD sample collected - Yes o r( N a ) Collection Time:
Well has fluoride treatment - Yes
Photograph No. (>
C f l i >'v\5 e)Y'f-V> //o ` .
MATERIAL CODES:
A G =Amber Glass; CG =Clear Glass;
P E =Polyethylene;
PP =Polypropylene; S = Silicone; T = Teflon; O =Other (Specify)
\MPLING EQUIPMENT CODES:
APP = After Peristaltic Pump; B = Bailer; B P = Bladder Pump; ESP = Electric Submersible Pump; RFPP = Reverse Flow Peristaltic Pump; SM = Straw Method (Tubing Gravity Drain); O = Other (Grab)
NOTES: 1. The above do not constitute all of the information required by Chapter 62-160, F.A.C.
2. Stabilization Criteria for range of variation of last three consecutive readings (see F S 2212. section 3)
pH: + 0.2 units Temperature: + 0.2 C Specific Conductance: t 5 A Dissolved Oxygen. all readings ^ 20 /o saturation (see Table FS 2200-2), optionally, + 0.2 mg/L or + 10% (whichever is greater) Turbidity: all readings < 20 NTU; optionally + 5 NTU or + 10% (whichever is greater)
Revision Date: February 12, 2009
GROUNDWATER SAMPLING LOG
p. 57
SITE NAME: ECUA Water Distribution System (County-wide)
ELL N0: CArf'ft5^ H ills
SITE LOCATION: Escambia County, Florida
/?fvSAMPLE ID:
VaJ
PURGING DATA
,DATE: February /
2010
WELL CASING
. _ TUBING
WELL SCREEN INTERVAL
PUMPING WATER
PURGE PUMP TYPE:
DIAMETER (inches): /
DIAMETER (inches): NA
DEPTH:
UNK
LEVEL (feet): UNK
Existing Pump
W ELL VOLUME PURGE: 1 W ELL VOLUME = (TOTAL WELL DEPTH - STATIC DEPTH TO WATER) X WELL CAPACITY
(only fill out If applicable)
= ( 2. 0.2
feet -
UNK
gallons
EQUIPMENT VOLUME PURGE: 1 EQUIPMENT VOL. = PUM P VOLUME + (TUBING CAPACITY
feet) X
gallons/foot =
X TUBING LENGTH) + FLOW CELL VOLUME
(only fill out if applicable)
= gallons + (
gallons/foot X
feet) +
gallons ==
gallons
PUM P DEPTH IN W ELL (feet): UNK
FINAL PUMP DEPTH IN W ELL (feet): UNK
PURGING
,
INITIATED AT: / / Y - i
PURGING ENDED AT:
TOTAL VOLUME PURGED (gallons):
TIME (CST)
//y e / / s '/ //ry
VOLUME PURGED (gallons)
CUMUL. VOLUME PURGED (gallons)
PURGE RATE (gpm)
ORP (mV)
-- --
pH (standard
units)
TEMP. (C)
2 X .ll Z/X
y . 4 o 2 2 - //
COND. (gS/cm)
yz
31
DISSOLVED OXYGEN (mg/L)
TURBIDITY (NTUs)
o o
COLOR (describe)
Clear Clear Clear
ODOR (describe)
None None None
.vELL CAPACITY (Gallons Per Foot): 0.75" = 0.02; 1" = 0.04; 1.25" = 0.06; 2" = 0.16; 3" = 0.37; 4" = 0.65; 5" =1.02; 6" = 1.47; 12" = 5.88 TUBING INSIDE DIA. CAPACITY (Gal./Ft.): 1/8" = 0.0006; 3/16" = 0.0014; 1/4* = 0.0026; 5/16 =0.004; 3/8" = 0.006; 1/2" = 0.010; 5/8" = 0.016
PURGING EQUIPMENT CODES: B = Bailer; BP = Bladder Pump;
ESP = Electric Submersible Pump;
PP = Peristaltic Pump;
O = Other (Specify)
SAMPLING DATA
SAM PLED B Y (PRINT) / AFFILIATION: David L. Anderson/CDM
SAM fLER(S) SIGNATURE(S):
SAMPLING , INITIATED AT: ! / S ip
SAMPLING ENDED AT:
PU M P DEPTH IN W ELL (feet): UNK
FIELD DECONTAMINATION:
PUMP: No
TUBING MATERIAL CODE: NA
TUBING: NA
FIELD-FILTERED: No Filtration Equipment Type:
DUPLICATE:
NA
FILTER SIZE: No
NA
um
SAMPLE CONTAINER SPECIFICATION
SAMPLE ID CODE
NA
# CONTAINERS
2
MATERIAL CODE
PE
VOLUME 1liter
SAMPLE PRESERVATION
PRESERVATIVE USED
None
TOTAL VOL ADDED IN FIELD (mL)
None
FINAL pH NA
INTENDED ANALYSIS AND/OR
METHOD
PFOA, PFOS, &
SAMPLING EQUIPMENT
CODE
O-Grab
SAMPLE PUMP FLOW RATE
(mL per minute)
<100 mL
Fluorinated Cmps
by HPLC/MS.
REMARKS: NA - Not Applicable.
UNK - Unknown.
Was the well pumping (active) prior to sampling -^Yes) or No.
MS/MSD sample collected - Yes or(^Ng^ Collection Time:
Well has fluoride treatment - Yes o^ Na)
Photograph No. 2^--
CftX'.'nj- cWi'+l'' IS2*.
MATERIAL CODES:
A G = Amber Glass; CG = Clear Glass; P E = Polyethylene; PP = Polypropylene; S = Silicone; T = Teflon; O = Other (Specify)
\MPLING EQUIPMENT CODES:
APP = After Peristaltic Pump; B = Bailer; BP = Bladder Pump; ESP = Electric Submersible Pump; RFPP = Reverse Flow Peristaltic Pump; SM = Straw Method (Tubing Gravity Drain); O = Other (Grab)
NOTES: 1. The above do not constitute all of the Information required by Chapter 62-160, F.A.C.
2. S T A B IL IZ A T IO N C R IT E R IA F O R R A N G E O F V A R IA TIO N O F L A S T T H R E E C O N S E C U T IV E R E A D IN G S ( S E E FS 2212. S E C T IO N 3)
pH: + 0.2 units Temperature: + 0.2 C Specific Conductance: +5% Dissolved Oxygen: all readings < 20% saturation (see Table FS 2200-2); optionally, + 0.2 mg/L or + 10% (whichever Is greater) Turbidity: all readings < 20 NTU; optionally + 5 NTU or + 10% (whichever Is greater)
Revision Date: February 12, 2009
GROUNDWATER SAMPLING LOG
p. 58
SITE I NAME: ECUA Water Distribution System (County-wide)
SITE LOCATION: Escambia County. Florida
ELL NO: C a f <; A f Q.
SAMPLE ID:
DATE: February / , 2010
PURGING DATA
WELL CASING
TUBING
WELL SCREEN INTERVAL
PUMPING WATER
PURGE PUM P TYPE:
DIAMETER (inches): 1
DIAMETER (inches): NA
DEPTH:
UNK
LEVEL (feet): UNK
Existing Pump
W ELL VOLUME PURGE: 1W ELL VOLUME = (TOTAL W ELL DEPTH - STATIC DEPTH TO WATER) X WELL CAPACITY (only fill out if applicable)
gallons
=( 0 2
feet-
UNK
feet) X
gallons/foot =
EQUIPMENT VOLUME PURGE: 1 EQUIPMENT VOL. = PUMP VOLUME + (TUBING CAPACITY X TUBING LENGTH) + FLOW CELL VOLUME (only fill out if applicable)
= gallons + (
gallons/foot X
feet) +
gallons =
gallons
PUMP DEPTH IN W ELL (feet): UNK
TIME (CST)
VOLUME PURGED (gallons)
CUMUL. VOLUME PURGED (gallons)
//S %
/2 a I
/Za q
FINAL PUMP DEPTH IN WELL (feet): UNK
PURGING INITIATED AT: / / V 5
PURGE RATE (gpm)
ORP (mV)
-
--
--
pH (standard
units)
TEMP. (C)
? -/y ? -/y
2/ -U
z f . 4fc>
Z f.
COND. (pS/om)
!
83
82.
PURGING ENDED AT:
DISSOLVED OXYGEN (mg/L)
1^31
TOTAL VOLUME PU RGED (gallons):
TURBIDITY (NTUs)
3
I /
COLOR (describe)
Clear Clear Clear
ODOR (describe)
None None None
.#ELL CAPACITY (Gallons Per Foot): 0.75" = 0.02; 1" = 0.04; 1.25" = 0.06; 2" = 0.16; 3" = 0.37; 4" = 0.65; 5" = 1.02; 6" = 1.47; 12" =5.88 TUBING INSIDE DIA. CAPACITY (Gal./Ft.): 1/8" = 0.0006; 3/16" =0.0014; 1/4" = 0.0026; 5/16" = 0.004; 3/8" = 0.006; 1/2" =0.010; 5/8" = 0.016
PURGING EQUIPMENT CODES: B = Bailer;
SAM PLED B Y (PRINT) / AFFILIATION: David L. Anderson/CDM
BP = Bladder Pump; ESP = Electric Submersible Pump; PP = Peristaltic Pump;
SAMPLING DATA
SAMPLER(S1SIGNATURE(S):
SAMPLING
/
INITIATED AT: / *
O = Other (Specify)
SAMPLING ENDED AT:
PUM P DEPTH IN W ELL (feet): UNK
TUBING MATERIAL CODE: NA
FIELD-FILTERED: No
FILTER SIZE: NA urn
Filtration Equipment Type: NA
FIELD DECONTAMINATION: PUMP: No
TUBING: NA
DUPLICATE:
No
SAMPLE CONTAINER SPECIFICATION
SAMPLE ID CODE
NA
# CONTAINERS
2
MATERIAL CODE PE
VOLUME 1liter
SAMPLE PRESERVATION
PRESERVATIVE USED
None
TOTAL VOL ADDED IN FIELD (mL)
None
FINAL pH NA
INTENDED ANALYSIS AND/OR
METHOD
PFOA, PFOS, &
SAMPLING EQUIPMENT
CODE
O-Grab
SAMPLE PUMP FLOW RATE
(mL per minute)
<100 m L
Fluorinated Cmps by HPLC/MS.
REMARKS: NA - Not Applicable.
UNK - Unknown.
Was the well pumping (active) prior to sampling ^ Y ei) or No.
MS/MSD sample collected - Yes or^t3o5 Collection Time:
Well has fluoride treatment - Yes qFN^>
Photograph No. ^
C-Q-r.'nr MATERIAL CODES:
K2 A G =Amber Glass; C G = Clear Glass;
PE = Polyethylene;
PP = Polypropylene; S = Silicone; T =Teflon; O = Other (Specify)
MMPLING EQUIPMENT COOES:
A P P = After Peristaltic Pump; B = Bailer; B P = Bladder Pump; ESP = Electric Submersible Pump; RFPP = Reverse Flow Peristaltic Pump; SM = Straw Method (Tublng Gravity Drain); 0 = Other (Grab)
NOTES: 1. The above do not constitute all of the information required by Chapter 62-160, F.A.C.
2 . S t a b i l i z a t i o n C r i t e r i a f o r r a n g e o f v a r i a t i o n o f l a s t t h r e e c o n s e c u t i v e r e a d i n g s (s e e F S 2 2 1 2 . s e c t i o n 3)
pH: + 0.2 units Temperature: + 0.2 C Specific Conductance: 5% Dissolved Oxygen: all readings < 20% saturation (see Table F S 2200-2); optionally, + 0.2 m g/L or + 10% (w hichever is greater) Turbidity: all readings < 20 NTU; optionally + 5 N T U or + 10% (w hichever is greater)
Revision Date: February 12, 2009
GROUNDWATER SAMPLING LOG
p. 59
SITE NAME: ECUA Water Distribution System (Countv-wide)
SITE LOCATION: Escambia County, Florida
'ELLN0: ( A j f m
SAM PLE ID:
PURGING DATA
DATE: February / ,2010
WELL CASING
TUBING
WELL SCREEN INTERVAL
PUMPING WATER
PURGE PUMP TYPE:
DIAMETER (inches): 0 N K DIAMETER (inches): NA
DEPTH:
UNK
LEVEL (feet): UNK
Existing Pump
W ELL VOLUME PURGE: 1 W ELL VOLUME = (TOTAL WELL DEPTH - STATIC DEPTH TO WATER) X WELL CAPACITY
(only fill out if applicable)
gallons
=< UNK
feet-
UNK
feet) X
gallons/foot =
EQUIPMENT VOLUM E PURGE: 1 EQUIPMENT VOL. = PUM P VOLUME + (TUBING CAPACITY X TUBING LENGTH) + FLOW CELL VOLUME
(only fill out If applicable)
= gallons + (
gallons/foot X
feet) +
gallons -
gallons
PUM P DEPTH IN W ELL (feet): UNK
TIME (CST)
VOLUME PURGED (gallons)
CUMUL. VOLUME PURGED (gallons)
/2.H-
!2 2 o
(Z2l
FINAL PUMP DEPTH IN WELL (feet): UNK
PURGING
/,
INITIATED AT:
PURGE RATE
(gpm)
ORP (mV)
-Z F f 221 "3c>o
pH (standard
units)
TEMP. (C)
5*. h i
s. HZ
sw ?
A\S~1 /'
COND. (pS/cm)
-- --
--
PURGING ENDED AT: DISSOLVED OXYGEN
(mg/L)
s .ll
S'-3 7
TOTAL VOLUME PURGED (gallons):
TURBIDITY (NTUs)
COLOR (describe)
ODOR (describe)
CD
Clear
None
O
Clear
None
O
Clear
None
.E L L CAPACITY (Gallons Per Foot): 0.75" = 0.02; 1" = 0.04; 1.25" = 0.06; 2" = 0.16; 3" = 0.37; 4" = 0.65; 5" = 1.02; 6" = 1.47; 12" = 5.88 TUBING INSIDE DIA. CA PA CIT Y (Gal./Ft.): 1/8" =0.0006; 3/16" = 0.0014; 1/4" = 0.0026; 5/16" =0.004; 3/8" = 0.006; 1/2" = 0.010; 5/8" = 0.016
PURGING EQUIPMENT CODES: B = Ballen B P = Bladder Pump;
E S P = Electric Submersible Pump;
PP = Peristaltic Pump;
0 = Other (Specify)
SAMPLING DATA
SAM PLED BY (PRINT) / AFFILIATION: David L. Anderson/CDM
SAMPLER(S) SIGNATURE(S):
SAMPLING INITIATED AT: / - - - b
SAMPLING ENDED AT:
PU M P DEPTH IN W ELL (feet): UNK
FIELD DECONTAMINATION:
PUMP: No
TUBING MATERIAL CODE: NA
TUBING: NA
FIELD-FILTERED: No Filtration Equipment Type:
DUPLICATE:
NA
FILTER SIZE: No
NA
urn
SAMPLE CONTAINER SPECIFICATION
SAMPLE ID CODE
NA
# CONTAINERS
2
MATERIAL CODE PE
VOLUME 1liter
SAMPLE PRESERVATION
PRESERVATIVE USED
None
TOTAL VOL ADDED IN FIELD (mL)
None
FINAL pH NA
INTENDED ANALYSIS AND/OR
METHOD
PFOA, PFOS, &
SAMPLING EQUIPMENT
CODE
O-Grab
SAMPLE PUMP FLOW RATE
(mL per minute)
<100 mL
Fluorinated Cmps
by HPLC/MS.
REMARKS: NA - Not Applicable.
Was the well pumping (active) prior to sampling
Well has fluoride treatm ent^ ^ B or No.
or No.
UNK - Unknown. MS/MSD sample collected - Yes or^ N o) Collection Time: Photograph No. ^
MATERIAL CODES:
A G = Amber Glass; CG = Clear Glass; PE = Polyethylene; PP = Polypropylene; S = Silicone; T = Teflon; O = Other (Specify)
'MPLING EQUIPMENT CODES:
A P P = After Peristaltic Pump;
B = Bailer; B P = Bladder Pump; ESP = Electric Submersible Pump;
RFPP = Reverse Flow Peristaltic Pump; SM = Straw Method (Tubing Gravity Drain); O = Other (Grab)
No TES: 1. The above do not constitute all of the information required by Chapter 62-160, F.A.C.
2 . S T A B ILIZ A T IO N C R IT E R IA F O R R A N G E O F V ARIA TIO N O F L A S T T H R E E C O N S E C U T IV E R E A D IN G S (S E E F S 2 2 1 2 . S E C T IO N 31
pH: +0 .2 units Temperature: +0 .2 C Specific Conductance: +5% Dissolved Oxygen: all readings < 2 0 % saturation (see Table FS 2 2 0 0 -2 ); optionally, + 0 .2 mg/L or + 10 % (whichever is greater) Turbidity: all readings < 2 0 NTU; optionally + 5 NTU or + 10 % (whichever is greater)
Revision Date: February 12, 2009
GROUNDWATER SAMPLING LOG
p. 60
I SITE I NAME: ECUA Water Distribution System (Countv-wide)
SITE LOCATION: Escambia Countv. Florida
ELL NO:
SAM PLE ID: - 7 ^ . ^
DATE: February ! , 2010
PURGING DATA
W ELL CASING DIAMETER (inches):
TUBING DIAMETER (inches): NA
W ELL SCREEN INTERVAL
DEPTH:
UNK
PUMPING WATER LEVEL (feet): UNK
PURGE PUMP TYPE: Existing Pump
W ELL VOLUME PURGE: 1 W ELL VOLUME = (TOTAL WELL DEPTH - STATIC DEPTH TO WATER) X WELL CAPACITY (only fill out if applicable)
gallons
= ( U/I/IC.
feet -
UNK
feet) X
gallons/foot =
EQUIPMENT VOLUME PURGE: 1 EQUIPMENT VOL. = PUMP VOLUME + (TUBING CAPACITY X TUBING LENGTH) + FLOW C E LL VOLUME (only fill out if applicable)
= gallons + (
gallons/foot X
feet) +
gallons :
gallons
PUMP DEPTH IN W ELL (feet): UNK
TIME (CST)
VOLUME PURGED (gallons)
CUMUL. VOLUME PURGED (gallons)
/22f
/2Jo
2.33
FINAL PUMP DEPTH IN W ELL (feet): UNK
PURGING INITIATED AT: / 2 / Li
PURGE RATE
(9Pm)
ORP (mV)
--
pH (standard
units)
TEMP. (C)
X/. ?l
COND. (pS/cm)
/$2.
-- 113
'< /7
PURGING ENDED AT:
DISSOLVED OXYGEN (mg/L)
V -t2 .
V -U
TOTAL VOLUME PURGED (gallons):
TURBIDITY (NTUs)
COLOR (describe)
ODOR (describe)
/
Clear
None
Clear
None
Clear
None
WELL CAPACITY (Gallons Per Foot): 0.75" = 0.02; 1" = 0.04; 1.25" = 0.06; 2" = 0.16; 3" = 0.37; 4" = 0.65; 5" =1.02; 6" = 1.47; 12" =5.08 TUBING INSIDE DIA. CAPACITY (GalTFt.): 1/8" = 0.0006; 3/16" =0.0014; 1/4" = 0.0026; 5/16" =0.004; 3/B" = 0.006; 1/2" = 0.010; 5/8* = 0.016
PURGING EQUIPMENT CODES: B = Bailer; BP = Bladder Pump;
ESP = Electric Submersible Pump;
PP = Peristaltic Pump;
O =Other (Specify)
SAMPLING DATA
SAM PLED BY (PRINT) / AFFILIATION: David L. Anderson/CDM
SA^ LR^ SI^ TU RE(S):
SAMPLING , INITIATED AT: ( 2 . 3 b
SAMPLING ENDED AT:
PUM P DEPTH IN W ELL (feet): UNK
FIELD DECONTAMINATION:
PUMP: No
TUBING MATERIAL CODE: NA
TUBING: NA
FIELD-FILTERED: No Filtration Equipment Type:
DUPLICATE:
NA
FILTER SIZE: No
NA
urn
SAMPLE CONTAINER SPECIFICATION
SAMPLE ID CODE
NA
# CONTAINERS
2
MATERIAL CODE
PE
VOLUME 1liter
SAMPLE PRESERVATION
PRESERVATIVE USED
None
TOTAL VOL ADDED IN FIELD (mL)
None
FINAL pH
NA
INTENDED ANALYSIS AND/OR
METHOD
PFOA, PFOS, &
SAMPLING EQUIPMENT
CODE
O-Grab
SAMPLE PUMP FLOW RATE
(mL per minute)
<100 mL
Fluorinated Cmps
by HPLC/MS.
REMARKS: NA - Not Applicable.
Was the well pumping (active) prior to sampling -^ 5^ or No.
Well has fluoride treatment ^ Y e sp r No.
UNK - Unknown. MS/MSD sample collected - Yes q^ n 5) Collection Time: Photograph No. /
MATERIAL CODES:
AG = Amber Glass; CG = Clear Glass; PE = Polyethylene; PP = Polypropylene; S = Silicone; T = Teflon; O = Other (Specify)
' MPLING EQUIPMENT CODES: APP = After Peristaltic Pump;
B = Bailer; BP = Bladder Pump; ESP = Electric Submersible Pump;
RFPP = Reverse Flow Peristaltic Pump; SM = Straw Method (Tubing Gravity Drain); O = Other (Grab)
NO TES: 1. The above do not constitute all of the Information required by Chapter 62-160, F.A.C. 2. STABILIZATION CRITERIA FOR RANGE OF VARIATION OF LAST THREE CONSECUTIVE READINGS (SEE F S 2212, SECTION 3)
pH: + 0.2 units Temperature: + 0.2 C Specific Conductance: +5% Dissolved Oxygen: all readings <20% saturation (see Table FS 2200-2); optionally, + 0.2 mg/L or + 10% (whichever is greater) Turbidity: all readings < 20 NTU; optionally + 5 NTU or + 10% (whichever is greater)
Revision Date; February 12, 2009
GROUNDWATER SAMPLING LOG
I SITE I NAME: ECUA Water Distribution System (County-wide)
SITE LOCATION: Escambia Countv. Florida
=L L N O :/ u o ^ r - P , W J
SAM PLE ID:
PURGING DATA
DATE: February / , 2010
WELL CASING
. . TUBING
WELL SCREEN INTERVAL
PUMPING WATER
PURGE PUMP TYPE:
DIAMETER (inches): Vn>
DIAMETER (inches): NA
DEPTH:
UNK
LEVEL (feet): UNK
Existing Pump
W ELL VOLUME PURGE: 1 W ELL VOLUME = (TOTAL WELL DEPTH - STATIC DEPTH TO WATER) X WELL CAPACITY
(only fill out if applicable)
= ( V /U lC
feet-
UNK
feet) X
gallons/foot
gallons
EQUIPMENT VO LU M E PU RGE: 1 EQUIPMENT VOL. = PUM P VOLUME + (TUBING CAPACITY X TUBING LENGTH) + FLOW CELL VOLUME
(only fill out if applicable)
= gallons + (
gallons/foot X
feet) +
gallons :
gallons
PU M P DEPTH IN W ELL (feet): UNK
TIME (CST)
VOLUME PURGED (gallons)
CUMUL. VOLUME PURGED (gallons)
/ ? ? 2.
13 3 f /33Z
FINAL PUMP DEPTH IN W ELL (feet): UNK
PURGING / 7 -, o INITIATED AT;/
PURGE RATE (gpm)
ORP (mV)
22Z
Z 2.? 22)
pH (standard
units)
TEMP. (C)
-2J-0
r.fc ? r.fc t
-2/-C> -ZY-o
COND. (pS/cm)
18
3k> 3^
PURGING ENDED AT:
DISSOLVED OXYGEN (mg/L)
3.ST-
3
7 -^ C .
TOTAL VOLUME PURGED (gallons):
TURBIDITY (NTUs)
COLOR (describe)
ODOR (describe)
Clear
None
o
Clear
None
O
Clear
None
.ELL C A PA CIT Y (Gallons Per Foot): 0.75" = 0.02; 1" = 0.04; 1.25" = 0.06; 2" = 0.16: 3" = 0.37; 4" = 0.65; 5" = 1.02; 6" =1.47; 12" = 5.88
TUBING INSIDE DIA. C A PA C IT Y (Gal./Ft.): 1/8" = 0.0006; 3/16" = 0.0014; 1/4" = 0,0026; 5/16" = 0.004;
3/8" = 0.006; 1/2" = 0.010; 5/8" =0.016
PURGING EQUIPMENT CODES: B= Bailer;____ B P = Bladder Pump;
E S P = Electric Submersible Pump;
PP = Peristaltic Pump;
O = Other (Specify)
SAMPLING DATA
SAM PLED B Y (PRINT) / AFFILIATION: David L. Anderson/CDM
SAMPLER(S) SjGNATURE(S):
SAMPLING l ? s j n INITIATED AT:
SAMPLING ENDED AT:
PU M P DEPTH IN W ELL (feet): UNK
FIELD DECONTAMINATION:
PUMP: No
TUBING MATERIAL CODE: NA
TUBING: NA
FIELD-FILTERED: No Filtration Equipment Type: NA
DUPLICATE:
FILTER SIZE: No
NA
um
SAMPLE CONTAINER SPECIFICATION
SAMPLE ID CODE
NA
#
CONTAINERS
2
MATERIAL CODE
PE
VOLUME 1liter
SAMPLE PRESERVATION
PRESERVATIVE USED
None
TOTAL VOL ADDED IN FIELD (mL)
None
FINAL pH NA
INTENDED ANALYSIS AND/OR
METHOD
PFOA, PFOS, &
Fluorinated Cmps
SAMPLING EQUIPMENT
CODE
O-Grab
SAMPLE PUMP FLOW RATE
(mL per minute)
<100 mL
by HPLC/MS.
REMARKS: NA - Not Applicable.
Was the well pumping (active) prior to sampling -(^ e?) or No.
Well has fluoride treatment ^Ye)or No.
UNK - Unknown. MS/MSD sample collected - Yes or^No^) Collection Time: Photograph No. / /
MATERIAL CODES:
A G = Amber Glass; CG = Clear Glass; PE = Polyethylene; P P = Polypropylene; S = Silicone; T = Teflon; O = Other (Specify)
' MPLING EQUIPMENT CODES: APP = After Peristaltic Pump;
B = Bailer; B P = Bladder Pump; E SP = Electric Submersible Pump;
RFPP = Reverse Flow Peristaltic Pump; SM = Straw Method (Tubing Gravity Drain); O =Other (Grab)
N O TES: 1. The above do not constitute all of the information required by Chapter 62-160, F.A.C. 2. S t a b il iz a t io n C r it e r ia f o r r a n g e o f v a r ia t io n o f l a s t t h r e e c o n s e c u t i v e r e a d i n g s (s e e F S 2 2 1 2 . s e c t io n 3)
pH: + 0.2 units Temperature: + 0.2 C Specific Conductance: +5% Dissolved Oxygen: all readings < 20% saturation (see Table FS 2200-2); optionally, + 0.2 mg/L or + 10% (whichever is greater) Turbidity: all readings < 20 NTU; optionally + 5 NTU or + 10% (whichever is greater) Revision Date: February 12, 2009
GROUNDWATER SAMPLING LOG
p. 62
I SITE I NAME: ECUA Water Distribution System (Countv-wide)
SITE LOCATION: Escambia County, Florida
ELLNO:
SAMPLE ID: ~7} PURGING DATA
DATE: February / ,2010
WELL CASING
y TUBING
WELL SCREEN INTERVAL
PUMPING WATER
PURGE PUMP TYPE:
DIAMETER (inches):
DIAMETER (inches): NA
DEPTH:
UNK
LEVEL (feet): UNK
Existing Pump
W ELL VOLUME PURGE: 1 W ELL VOLUME = (TOTAL WELL DEPTH - STATIC DEPTH TO WATER) X WELL CAPACITY (only fill out if applicable)
gallons
=( UW K
feet-
UNK
feet) X
gallons/foot =
EQUIPMENT VOLUME PURGE: 1 EQUIPMENT VOL. = PUMP VOLUME + (TUBING CAPACITY (only fill out if applicable)
TUBING LENGTH) + FLOW CELL VOLUME
= gallons + (
gallons/foot X
feet) +
gallons =
gallons
PU M P DEPTH IN W ELL (feet): UNK
TIME (CST)
VOLUME PURGED (gallons)
CUMUL. VOLUME PURGED
(gallons)
/3<r*
PS3
FINAL PUMP DEPTH IN W ELL (feet): UNK
PURGING
17 7
INITIATED AT: i J J v
PURGE RATE
(gpm)
ORP (mV)
Jffo
ra
S ilo
pH (standard
units)
TEMP. (C)
l .ih Las
2 ?S 2 .? f 2 .??-
COND. (pS/cm)
/22.
PURGING ENDED AT:
DISSOLVED OXYGEN (mg/L)
3. 8 ?
S3
G>
TOTAL VOLUME PURGED (gallons):
TURBIDITY (NTUs)
2.
/ /
COLOR (describe)
Clear Clear Clear
ODOR (describe)
None None None
WELL CAPACITY (Gallons Per Foot): 0.75" = 0.02; 1" = 0.04; 1.25" = 0.06; 2" = 0.16; 3" = 0.37; 4" =0.65; 5" = 1.02; 6" = 1.47; 12" =5.88 TUBING INSIDE DIA. CAPACITY (Gal./Ft.): 1/8" = 0,0006; 3/16" = 0.0014; 1/4" = 0.0026; 5/16" =0.004; 3/8" = 0.006; 1/2" = 0.010; 5/6" =0.016
PURGING EQUIPMENT CODES: B = Bailer;
SAM PLED BY (PRINT) / AFFILIATION; David L. Anderson/CDM
B P = Bladder Pump;
E SP = Electric Submersible Putnp;
PP = Peristaltic Pump;
SAMPLING DATA
SA riPLER(S) SIQNATURE(S):
SAMPLING <7 r e INITIATED AT: / O
O = Other (Specify)
SAMPLING ENDED AT:
PU M P DEPTH IN W ELL (feet): UNK
TUBING MATERIAL CODE: NA
FIELD-FILTERED: No
FILTER SIZE: NA urn
Filtration Equipment Type: NA
FIELD DECONTAMINATION: PUMP: No
TUBING: NA
DUPLICATE:
No
SAMPLE CONTAINER SPECIFICATION
SAMPLE ID CODE
NA
ff CONTAINERS
2
MATERIAL CODE
PE
VOLUME 1liter
SAMPLE PRESERVATION
PRESERVATIVE USED
None
TOTAL VOL ADDED IN FIELD (mL)
None
FINAL PH NA
INTENDED ANALYSIS AND/OR
METHOD
PFOA, PFOS, &
Fluorlnated Cmps
SAMPLING EQUIPMENT
CODE
O-Grab
SAMPLE PUMP FLOW RATE
(mL per minute)
<100 mL
by HPLC/MS.
REMARKS: NA - Not Applicable.
W as the well pumping (active) prior to sampling -(^ ? or No.
Well has fluoride treatment
or No.
UNK - Unknown. MS/MSD sample collected - Yes or (No5 Collection Time:
Photograph No. 2.
MATERIAL CODES:
A G =Amber Glass; C G = Clear Glass; P E = Polyethylene; PP = Polypropylene; S = Silicone; T =Teflon; O = Other (Specify)
' MPLING EQUIPMENT CODES: A P P = After Peristaltic Pump;
B = Bailer; B P = Bladder Pump; E SP = Electric Submersible Pump;
RFPP = Reverse Flow Peristaltic Pump; SM = Straw Method (Tubing Gravity Drain); O = Other (Grab)
N O TES: 1. The above do not constitute all of the information required by Chapter 62-160, F.A.C. 2. S t a b il iz a t io n C r it e r ia f o r r a n g e o f v a r ia t io n o f l a s t t h r e e c o n s e c u t i v e r e a d i n g s (s e e F S 2 2 1 2 . s e c t i o n 3)
pH: + 0.2 units Temperature: + 0.2 C Specific Conductance: +5% Dissolved Oxygen: all readings < 20% saturation (see Table FS 2200-2); optionally, + 0.2 mg/L or + 10% (whichever is greater) Turbidity: all readings < 20 NTU; optionally + 5 NTU or + 10% (whichever is greater) Revision Date: February 12, 2009
GROUNDWATER SAMPLING LOG
SITE NAME: ECUA Water Distribution System (Countv-wide)
SITE LOCATION: Escambia County, Florida
E H NO: ( 2 p \K iT<0\r\{ i\^ 'i4 '
SAM PLE ID:
Uj
DATE: February
, 2010
PURGING DATA
W ELL CASING
-,
DIAMETER (inches): ^ ^
TUBING DIAMETER (inches): NA
WELL SCREEN INTERVAL
DEPTH:
UNK
PUMPING WATER LEVEL (feet): UNK
PURGE PUMP TYPE: Existing Pump
W ELL VOLUME PURGE: 1 W ELL VOLUME = (TOTAL WELL DEPTH - STATIC DEPTH TO WATER) X WELL CAPACITY
(only fill out if applicable)
gallons
=< 7 3 8
feet -
UNK
EQUIPMENT VOLUME PURGE: 1 EQUIPMENT VOL. = PUMP VOLUME + (TUBING CAPACITY
feet) X
gallons/foot =
TUBING LENGTH) + FLOW CELL VOLUME
(only fill out if applicable)
gallons + (
gallons/foot X
feet) -t-
gallons =
gallons
PU M P DEPTH IN W ELL (feet): UNK
TIME (CST)
VOLUME PURGED
(gallons)
CUMUL. VOLUME PURGED (gallons)
/ V o (o
/V O ?
H /2 .
FINAL PUMP DEPTH IN WELL (feet): UNK
PURGING
j
INITIATED AT: / 7 J
PURGE RATE
(gpm)
ORP (mV)
2zs --
pH (standard
units)
.S'. 64
TEMP. (C)
2 o .? Y
f.L S', t i o
ito -? ? .2=>.?y
COND, (liS/cm)
JV
33
32
PURGING ENDED AT:
DISSOLVED OXYGEN (mg/L)
r.r/
r.ro
r.< ro
TOTAL VOLUME PU RGED (gallons):
TURBIDITY (NTUs)
G O Q>
COLOR (describe)
Clear Clear Clear
ODOR (describe)
None None None
WELL CAPACITY (Gallons Per Foot): 0.75" = 0.02; 1" = 0.04; 1.25" = 0.06; 2" = 0.16; 3" = 0.37; 4" = 0.65; 5" =1.02; 6"=1.47; 12" = 5.88
TUBING INSIDE PIA. CAPACITY (Gal./Ft.): 1/8" = 0.0006; 3/16" = 0.0014; 1/4" = 0.0026; 5/16" = 0.004;
3/8" = 0.006; 1/2" = 0.010;
= 0.016
PURGING EQUIPMENT CODES: B = Bailer; BP = Bladder Pump;
ESP = Electric Submersible Pump;
PP = Peristaltic Pump;
O = Other (Specify)
SAMPLING DATA
SAM PLED B Y (PRINT) / AFFILIATION: David L. Anderson/CDM
SAMPLER(S) SIGNATURE(S):
SAMPLING INITIATED AT: /?/ >
SAMPLING ENDED AT:
PU M P DEPTH IN W ELL (feet): UNK
FIELD DECONTAMINATION:
PUMP: No
TUBING MATERIAL CODE: NA
TUBING: NA
FIELD-FILTERED: No Filtration Equipment Type:
DUPLICATE:
NA
FILTER SIZE: No
NA
urn
SAMPLE CONTAINER SPECIFICATION
SAMPLE ID CODE
NA
# CONTAINERS
2
MATERIAL CODE
PE
VOLUME 1liter
SAMPLE PRESERVATION
PRESERVATIVE USED
None
TOTAL VOL ADDED IN FIELD (mL)
None
FINAL pH
NA
INTENDED ANALYSIS AND/OR
METHOD
PFOA, PFOS, &
SAMPLING EQUIPMENT
CODE
O-Grab
SAMPLE PUMP FLOW RATE
(mL per minute)
<100 mL
Fluorinated Cmps
by HPLC/MS.
REMARKS: NA - Not Applicable.
UNK - Unknown.
Was the well pumping (active) prior to sampling -^Ye?) or No.
MS/MSD sample collected - Yes or/Nc^) Collection Time:
Well has fluoride treatment
or No.
Photograph No. 13
C f l J T n i <UM\s 3 V S ' ' .
MATERIAL CODES:
AG =Amber Glass; CG = Clear Glass; PE = Polyethylene; PP = Polypropylene; S = Silicone; T =Teflon; O = Other (Specify)
VMPLING EQUIPMENT CODES: APP = After Peristaltic Pump;
B = Bailer; BP = Bladder Pump; ESP = Electric Submersible Pump;
RFPP = Reverse Flow Peristaltic Pump; SM = Straw Method (Tubing Gravity Drain); O =Other (Grab)
NOTES: 1. The above do not constitute all of the information required by Chapter 62-160, F.A.C.
2. Stabilization C riteria for range o f variation o f last three con secutive readings (see FS 2212. section 3)
pH: + 0.2 units Temperature: + 0.2 C Specific Conductance: + 5% Dissolved Oxygen: all readings <20% saturation (see Table FS 2200-2); optionally, + 0.2 mg/L or + 10% (whichever is greater) Turbidity: all readings < 20 NTU; optionally + 5 NTU or + 10% (whichever is greater)
Revision Date; February 12, 2009
GROUNDWATER SAMPLING LOG
p. 64
I SITE I NAME: ECUA Water Distribution System (County-wide)
ELL NO:
SAMPLE ID:
SITE LOCATION: Escambia County. Florida
DATE: February / ,2010
PURGING DATA
W ELL CASING n TUBING
WELL SCREEN INTERVAL
PUMPING WATER
PURGE PUMP TYPE:
DIAMETER (inches): ^ G DIAMETER (inches): NA
DEPTH:
UNK
LEVEL (feet): UNK
Existing Pump
W ELL VOLUME PURGE: 1 W ELL VOLUME = (TOTAL WELL DEPTH - STATIC DEPTH TO WATER) X WELL CAPACITY (only fill out it applicable)
gallons
= ( 13 8
fast -
UNK
feet) X
gallons/foot =
EQUIPMENT VOLUME PURGE: 1 EQUIPMENT VOL. = PU M P VOLUME + (TUBING CAPACITY (only fill out if applicable)
TUBING LENGTH) + FLOW CELL VOLUME
= gallons + (
gallons/foot X
feet) +
gallons =
gallons
PU M P DEPTH IN W ELL (feet): UNK
TIME (CST)
VOLUME PURGED (gallons)
CUMUL. VOLUME PURGED (gallons)
H 2**
FINAL PUMP DEPTH IN W ELL (feet): UNK
PURGE RATE (gpm)
ORP (mV)
pH (standard
units)
L&s 7- 33
PURGING
_
INITIATED AT: ' "
PURGING ENDED AT:
TEMP. (C)
COND. (gS/cm)
DISSOLVED OXYGEN (mg/L)
/ 7 -f
if.tb
//s'
// 4
r - 4// r.J jT
TOTAL VOLUME PURGED (gallons):
TURBIDITY (NTUs)
COLOR (describe)
ODOR (describe)
1
Clear
None
0
Clear
None
H Z*
s . l l4/6
7 -/ 4 -2c.- cs/
//?
/
Clear
None
m i*
4/0
7/7
.2-0.01 //4
r.v o
1
./E L L CAPACITY (Gallons Per Foot): 0.75" = 0.02; 1" = 0.04: 1.25" = 0.06; 2" = 0.16; 3" = 0.37; 4" =0.65; 5" =1.02; 6" =1.47; 12" = 5.88 TUBING INSIDE DIA. CAPACITY (Gal./Ft.): 1/8" = 0.0006; 3/16" = 0.0014; 1/4" =0,0026; 5/16" =0.004; 3/8" = 0.006; 1/2" = 0,010; 5/8" =0.016
PURGING EQUIPMENT CODES: B = Bailer; B P = Bladder Pump;
E S P = Electric Submersible Pump;
PP = Peristaltic Pump;
O = Other (Specify)
SAMPLING DATA
SAM PLED B Y (PRINT) / AFFILIATION: David L. Anderson/CDM
SAMPLER(S)SIGNATURE(S):
SAMPLING . , INITIATED AT: / L f 2 (<,
SAMPLING ENDED AT:
PU M P DEPTH IN W ELL (feet): UNK
TUBING MATERIAL CODE: NA
FIELD-FILTERED: No
FILTER SIZE: NA
Filtration Eguipment Type: NA
urn
FIELD DECONTAMINATION:
PUMP: No
TUBING: NA
DUPLICATE:
No
SAMPLE CONTAINER SPECIFICATION
SAMPLE ID CODE
NA
# CONTAINERS
2
MATERIAL CODE
PE
VOLUME 1liter
SAMPLE PRESERVATION
PRESERVATIVE USED
None
TOTAL VOL ADDED IN FIELD (mL)
None
FINAL pH NA
INTENDED ANALYSIS AND/OR
METHOD
PFOA, PFOS, &
SAMPLING EQUIPMENT
CODE
O-Grab
SAMPLE PUMP FLOW RATE
(mL per minute)
<100 mL
Fluorinated Cmps
by HPLC/MS.
REMARKS: NA - Not Applicable.
UNK - Unknown.
Was the well pumping (active) prior to sampling ^Ye) or No.
MS/MSD sample collected - Yes or ( N o ) Collection Time:
Well has fluoride treatment ^Yjs or No.
Photograph No. /^/*
6 t)T rfly
3V i
MATERIAL CODES:
A G = Amber Glass; CG = Clear Glass;
P E = Polyethylene;
PP = Polypropylene; S = Silicone; T =Teflon; O = Other (Specify)
' MPLING EQUIPMENT CODES: APP = After Peristaltic Pump;
B = Bailer; B P = Bladder Pump; ESP = Electric Submersible Pump;
RFPP = Reverse Flow Peristaltic Pump; SM = Straw Method (Tubing Gravity Drain); O = Other (Grab)
NO TES: 1. The above do not constitute all of the information required by Chapter 62-160, F.A.C.
2. STABILIZATION CRITERIA FOR RAN GE O F VARIATION OF LAST THREE CO NSECUTIVE READINGS (SEE F S 2 2 1 2 . SECTION 3)
pH: + 0.2 units Temperature: + 0.2 C Specific Conductance: +5% Dissolved Oxygen: all readings <20% saturation (see Table FS 2200-2); optionally, + 0.2 mg/L or + 10% (whichever is greater) Turbidity: all readings < 20 NTU; optionally + 5 NTU or + 10% (whichever is greater)
Revision Date: February 12, 2009
GROUNDWATER SAMPLING LOG
I SITE I NAME: ECUA Water Distribution System (County-wide)
SITE LOCATION: Escambia County, Florida
ELL NO: y V W /V\( )e
SAM PLE ID:
DATE: February j , 2010
PURGING DATA
W ELL CASING
-,
TUBING
WELL SCREEN INTERVAL
PUMPING WATER
PURGE PUMP TYPE:
DIAMETER (inches):
DIAMETER (inches): NA
DEPTH:
UNK
LEVEL (feet): UNK
Existing Pump
WELL VOLUME PURGE: 1 WELL VOLUME = (TOTAL W ELL DEPTH - STATIC DEPTH TO WATER) X W ELL CAPACITY
(only fill out if applicable)
=( 3 40
feet-
UNK
feet) X
gallons/foot =
gallons EQUIPMENT VOLUME PURGE: 1 EQUIPMENT VOL. = PUMP VOLUME + (TUBING CAPACITY X TUBING LENGTH) + FLOW CELL VOLUME
(only fill out If applicable)
= gallons + (
gallons/foot X
feet) +
gallons :
gallons
PU M P DEPTH IN W ELL (feet): UNK
TIME (CST)
VOLUME PURGED (gallons)
CUMUL. VOLUME PURGED (gallons)
%
FINAL PUM P DEPTH IN W ELL (feet): UNK
PURGING ,
INITIATED AT- . i H H >
PURGING ENDED AT:
PURGE RATE (gpm)
ORP (mV)
-- --
--
pH (standard
units)
r.io
TEMP. (C)
(*> P f-C /f-
COND. (pS/cm)
3
DISSOLVED OXYGEN (mg/L)
So
TOTAL VOLUME PURGED (gallons):
TURBIDITY (NTUs)
COLOR (describe)
ODOR (describe)
c
Clear
None
Clear
None
O
Clear
None
WELL CAPACITY (Gallons Per Foot): 0.75" = 0.02; 1" = 0.04; 1.25" = 0.06; 2" = 0.16; 3" = 0.37; 4" = 0.65; 5" =1.02; 6" = 1.47; 12" = 5.88 TUBING INSIDE DIA. CAPACITY (Gal./Ft ): 1/8" = 0.0006; 3/16" = 0.0014; 1/4" = 0.0026; 5/16" = 0.004; 3/B" = 0.006; 1/2" = 0.010; 5/8` = 0.016
PURGING EQUIPMENT CODES: B = Bailer;
SA M PLED BY (PRINT) / AFFILIATION: David L. Anderson/CDM
BP = Bladder Pump;
ESP = Electric Submersible Pump;
PP = Peristaltic Pump;
SAMPLING DATA
SAMPLER(S)lSIGNATURE(S):
SAMPLING INITIATED AT: / V S -T
O = Other (Specify)
SAMPLING ENDED AT:
PU M P DEPTH IN WELL (feet): UNK
TUBING MATERIAL CODE: NA
FIELD-FILTERED: No
FILTER SIZE: NA
Filtration Equipment Type: NA
urn
FIELD DECONTAMINATION:
PUMP: No
TUBING: NA
DUPLICATE:
No
SAM PLE CONTAINER SPECIFICATION
SAMPLE ID CODE
NA
# CONTAINERS
2
MATERIAL CODE
PE
VOLUME I liter
SAMPLE PRESERVATION
PRESERVATIVE USED
None
TOTAL VOL ADDED IN FIELD (mL)
None
FINAL pH NA
INTENDED ANALYSIS AND/OR
METHOD
PFOA, PFOS, &
Fluorlnated Cmps
SAMPLING EQUIPMENT
CODE
O-Grab
SAMPLE PUMP FLOW RATE
(mL per minute)
<100 mL
by HPLC/MS.
REMARKS: NA - Not Applicable.
UNK - Unknown.
W as the well pumping (active) prior to sampling -{Ye^ or No.
MS/MSD sample collected - Yes or(^No) Collection Time:
Well has fluoride treatment - j'fls jo r No.
Photograph No. / "
c a r.-Aj- cX^f-l' - 2 . S 0
MATERIAL CODES:
AG = Amber Glass; CG = Clear Glass; PE = Polyethylene; PP = Polypropylene; S = Silicone; T =Teflon; O = Other (Specify)
'MPLING EQUIPMENT CODES: APP = After Peristaltic Pump;
B = Bailer; BP = Bladder Pump; ESP = Electric Submersible Pump;
RFPP = Reverse Flow Peristaltic Pump; SM = Straw Method (Tubing Gravity Drain); O = Other (Grab)
NOTES: 1. The above do not constitute all of the information required by Chapter 62-160, F.A.C.
2. S t a b il iz a t io n C r it e r ia f o r r a n g e o f v a r ia t io n o f l a s t t h r e e c o n s e c u t i v e r e a d i n g s (s e e F S 2 2 1 2 , s e c t io n 3)
pH: + 0.2 units Temperature: + 0.2 C Specific Conductance: +5% Dissolved Oxygen: all readings < 20% saturation (see Table FS 2200-2); optionally, + 0.2 mg/L or + 10% (whichever is greater) Turbidity: all readings < 20 NTU; optionally + 5 NTU or + 10% (whichever is greater)
Revision Date: February 12, 2009
GROUNDWATER SAMPLING LOG
p. 66
I SITE I NAME: ECUA Water Distribution System (County-wide)
SITE LOCATION: Escambia Countv. Florida
ELL NO:
w
SAMPLE ID:
/You
PURGING DATA
DATE: February 2 .2010
WELL CASING
-,
DIAMETER (inches): ^
TUBING DIAMETER (inches): NA
WELL SCREEN INTERVAL
DEPTH:
UNK
PUMPING WATER LEVEL (feet): UNK
PURGE PUMP TYPE: Existing Pump
W ELL VOLUME PURGE: 1 W ELL VOLUME = (TOTAL WELL DEPTH - STATIC DEPTH TO WATER) X WELL CAPACITY
(only fill out if applicable)
gallons
=( 335"
feet-
UNK
feet) X
gallons/foot =
EQUIPMENT VOLUME PURGE: 1 EQUIPMENT VOL. = PUMP VOLUME + (TUBING CAPACITY X TUBING LENGTH) + FLOW CELL VOLUME
(only fill out If applicable)
= gallons + (
gallons/foot X
feet) +
gallons =
gallons
PU M P DEPTH IN WELL (feet): UNK
TIME (CST)
VOLUME PURGED (gallons)
CUMUL. VOLUME PURGED
(gallons)
OSc 8 6 8 It
FINAL PUMP DEPTH IN W ELL (feet): UNK
PURGING INITIATED AT:
PURGE RATE (gpm)
ORP (mV)
/e r
/e?
pH (standard
units)
TEMP. (C)
--
-- JU-S1
COND. (pS/cm)
3?
/< 8
--
2 .1-S H
3 -
PURGING ENDED AT:
DISSOLVED OXYGEN (mg/L)
TOTAL VOLUME PURGED (gallons):
TURBIDITY (NTUs)
COLOR (describe)
ODOR (describe)
o
Clear
None
Clear
None
Clear
None
./ELL CAPACITY (Gallons Per Foot): 0.75" = 0.02; 1" = 0.04; 1.25" = 0.06; 2" = 0.16; 3" = 0.37; 4" = 0.65; 5" =1.02; 6" = 1.47; 12" = 5.88 TUBING INSIDE DIA. CAPACITY (GalVFt.): 1/8''= 0.0006; 3/16" = 0.0014; 1/4" = 0.0026; 5/16" =0.004; 3/8 =0.006; 1/2" = 0.010; 5/8" = 0.016
PURGING EQUIPMENT CODES: B = Bailer;
SAM PLED BY (PRINT) / AFFILIATION: David L. Anderson/CDM
BP = Bladder Pump;
ESP = Electric Submersible Pump;
PP = Peristaltic Pump;
SAMPLING DATA
SAMPLER(S)jSJGNATURE(S):
SAMPLING _ _
INITIATED AT:
!*-
O = Other (Specify)
SAMPLING ENDED AT:
PUM P DEPTH IN W ELL (feet): UNK
TUBING MATERIAL CODE: NA
FIELD-FILTERED: No
FILTER SIZE: NA
Filtration Equipment Type: NA
urn
FIELD DECONTAMINATION: PUMP: No
TUBING: NA
DUPLICATE:
No
SAMPLE CONTAINER SPECIFICATION
SAMPLE ID CODE
NA
ff CONTAINERS
2
MATERIAL CODE
PE
VOLUME I liter
SAMPLE PRESERVATION
PRESERVATIVE USED
None
TOTAL VOL ADDED IN FIELD (mL)
None
FINAL PH NA
INTENDED ANALYSIS AND/OR
METHOD
PFOA, PFOS, &
Fluorinated Cmps
SAMPLING EQUIPMENT
CODE
O-Grab
SAMPLE PUMP FLOW RATE
(mL per minute)
<100 mL
by HPLC/MS.
REMARKS: NA - Not Applicable.
UNK - Unknown.
Was the well pumping (active) prior to sampling
or No.
MS/MSD sample collected - Yes o^ n 3>j Collection Time:
Well has fluoride treatment
No.
Photograph No. I
cft/vn f
m o '.
2?/a w K i . c
a 4- uo<xIk**), C T iS g o o .
MATERIAL CODES:
AG =Amber Glass; CG = Clear Glass; PE = Polyethylene; PP = Polypropylene; S = Silicone; T =Teflon; O = Other (Specify)
'MPLING EQUIPMENT CODES: APP = After Peristaltic Pump;
B = Bailer; BP = Bladder Pump; ESP = Electric Submersible Pump;
RFPP = Reverse Flow Peristaltic Pump; SM = Straw Method (Tubing Gravity Drain); O = Other (Grab)
N O TE S: 1. The above do not constitute all of the information required by Chapter 62-160, F.A.C.
2. STABILIZATIO N C R IT E R IA F O R R A N G E O F VARIATION O F L A S T T H R E E C O N S E C U T IV E R E A D IN G S (S E E FS 2212. SECTIO N 3)
pH:+0.2 units Temperature:+0.2 C Specific Conductance: +5% Dissolved Oxygen: all readings <20% saturation (see Table FS 2200-2); optionally, + 0.2 m g/Lor + 10% (whichever is greater) Turbidity: all readings <20 NTU; optionally + 5 NTU or + 10% (whichever is greater)
Revision Date: February 12, 2009
GROUNDWATER SAMPLING LOG
p. 67
SITE NAME: ECUA Water Distribution System (County-wide)
SITE LOCATION: Escambia County, Florida
`ELL NO:
SAM PLE ID:
DATE: February
, 2010
PURGING DATA
WELL CASING
^
TUBING
W ELL SCREEN INTERVAL
PUMPING WATER
PURGE PUMP TYPE:
DIAMETER (inches): 0
DIAMETER (inches): NA
DEPTH:
UNK
LEVEL (feet): UNK
Existing Pump
WELL VOLUME PURGE: 1 WELL VOLUME = (TOTAL W ELL DEPTH - STATIC DEPTH TO WATER) X WELL CAPACITY
(only fill out if applicable)
=( 3 3 5
feet -
UNK
feet) X
gallons/foot =
gallons EQUIPMENT VOLUME PURGE: 1 EQUIPMENT VOL. =PUM P VOLUM E +(TUBING CAPACITY X TUBING LENGTH) + FLOW CELL VOLUME
(only fill out if applicable)
= gallons +(
gallons/foot X
feet) +
gallons =
gallons
PUM P DEPTH INW ELL (feet): UNK
TIME (CST)
VOLUME PURGED (gallons)
CUMUL. VOLUME PURGED (gallons)
C6N
FINAL PUMP DEPTH IN W ELL (feet): UNK
PURGING INITIATED AT:
PURGING
b 2- ENDED AT:
PURGE RATE (9Pm)
ORP (mV)
fSt
/iTZ / 2T/
PH (standard
units)
TEMP. (C)
?-e.r 7 - l
-2 /. 13 -2 f ./ y
COND. (pS/cm)
2 r* /& /?& I1-
DISSOLVED OXYGEN (mg/L)
3.8<
7. 87
3.5o
TOTAL VOLUME PURGED (gallons):
TURBIDITY (NTUs)
COLOR (describe)
ODOR (describe)
7
Clear
None
~Z-
Clear
None
2-
Clear
None
.ELL CAPACITY (Gallons Per Foot): 0.75" = 0.02; 1" = 0.04; 1.25" = 0.06; 2" = 0.16; 3" = 0.37; 4" =0.65; 5" = 1.02; 6" = 1.47; I2" = 5.88 TUBING INSIDE DIA. CAPACITY (Gal/Ft.): 1/8" =0.0006; 3/16" =0.0014; 1/4" = 0.0026; 5/16" =0.004; 3/8" =0.006; 1/2" =0.010; S/8" =0.016
PURGING EQUIPMENT CODES: B =Bailer; BP =Bladder Pump;
ESP =Electric Submersible Pump;
PP = Peristaltic Pump;
O =Other (Specify)
SAMPLING DATA
SAM PLED BY (PRINT) / AFFILIATION: David L. Anderson/CDM
SAMPLER(S)IGNATURE(S):
SAMPLING
INITIATED AT: O g -2.
SAMPLING ENDED AT:
PU M P DEPTH IN W ELL (feet): UNK
FIELD DECONTAMINATION:
PUMP: No
TUBING MATERIAL CODE; NA
TUBING: NA
FIELD-FILTERED: No Filtration Egulpment Type:
DUPLICATE;
NA
FILTER SIZE: No
NA
urn
SAMPLE CONTAINER SPECIFICATION
SAMPLE ID CODE
NA
# CONTAINERS
2
MATERIAL CODE PE
VOLUME 1liter
SAMPLE PRESERVATION
PRESERVATIVE USED
None
TOTAL VOL ADDED IN FIELD (mL)
None
FINAL pH NA
INTENDED ANALYSIS AND/OR
METHOD
PFOA, PFOS, &
Fluorinated Cmps
SAMPLING EQUIPMENT
CODE
O-Grab
SAMPLE PUMP FLOW RATE
(mL per minute)
<100 mL
by HPLC/MS.
REMARKS: NA - Not Applicable.
UNK - Unknown.
Was the well pumping (active) prior to sampling ^Y|^ or No.
MS/MSD sample collected - Yes oi^No^) Collection Time:
Well has fluoride treatment -y or No.
Photograph No. 2 --
C fti'rn vy
/V O * .
MATERIAL CODES:
A G = Amber Glass; CG =Clear Glass; P E = Polyethylene; PP =Polypropylene; S = Silicone; T = Teflon; O =Other (Specify)
' MVIPLING EQUIPMENT CODES:
APP = After Peristaltic Pump;
B = Bailer; B P = Bladder Pump; E SP = Electric Submersible Pump;
RFPP = Reverse Flow Peristaltic Pump; SM = Straw Method (Tubing Gravity Drain); 0 = Other (Grab)
NoTES: 1. The above do not constituteall of the information required by Chapter 62-160, F.A.C.
2. Stabilization Criteria for range of variation of last three consecutive readings (see F S 2212, section 3)
pH: 0.2 units Temperature: + 0.2 C Specific Conductance: + 5% Dissolved Oxygen: all readings < 20% saturation (see Table FS 2200-2); optionally, + 0.2 mg/L or + 10% (whichever is greater) Turbidity: all readings < 20 NTU; optionally + 5 NTU or 10% (whichever is greater)
Revision Date; February 12, 2009
I W in I w v v v f c - r
GROUNDWATER SAMPLING LOG
p. 68
SITE NAME: ECUA Water Distribution System (Countv-wide)
SITE LOCATION: Escambia Countv. Florida
ELL NO; /)) c C o t /
SAM PLE ID:
DATE: February Z . ,2010
PURGING DATA
WELL CASING
TUBING
WELL SCREEN INTERVAL
PUMPING WATER
PURGE PUMP TYPE:
DIAMETER (inches):
DIAMETER (inches): NA
DEPTH:
UNK
LEVEL (feet): UNK
Existing Pump
W ELL VOLUME PURGE: 1 W ELL VOLUME = (TOTAL WELL DEPTH - STATIC DEPTH TO WATER) X WELL CAPACITY (only fill out if applicable)
gallons
= ( 2.1 0
feet -
UNK
feet) X
gallons/foot =
EQUIPMENT VOLUME PURGE: 1 EQUIPMENT VOL. = PUMP VOLUME + (TUBING CAPACITY X TUBING LENGTH) + FLOW CELL VOLUME (only fill out if applicable)
= gallons + (
gallons/foot X
feet) +
gallons =
gallons
PU M P DEPTH IN W ELL (feet): UNK
TIME (CST)
VOLUME PURGED (gallons)
CUMUL. VOLUME PURGED
(gallons)
6 8 VO
FINAL PUM P DEPTH IN W ELL (feet): UNK
PURGING INITIATED AT: O 'o
PURGE RATE (gpm)
ORP (mV)
pH (standard
units)
TEMP. (C)
S'. 8 ? r.s s
J -l-!< i z \- n
COND. (pS/cm)
vv
r.S 8
PURGING ENDED AT:
DISSOLVED OXYGEN (mg/L)
7 -0 ?
I TOTAL VOLUME | PU RGED (gallons):
TURBIDITY (NTUs)
6
COLOR (describe)
Clear Clear Clear
ODOR (describe)
None None None
. ELL CAPACITY (Gallons Per Foot): 0.75" = 0.02; 1" = 0.04; 1.25" = 0.06; 2" = 0.16; 3" = 0.37; 4" = 0.65; 5" = 1.02; 6" = 1.47; 12" = 5.88 TUBING INSIDE DIA. CAPACITY (Gal ./Ft): 1/8" = 0.0006; 3/16" = 0.0014; 1/4" = 0.0026; 5/16" =0.004; 3/8" = 0.006; 1/2" = 0.010; 5/8" = 0.016
PURGING EQUIPMENT CODES: B = Bailer; BP = Bladder Pump;
ESP = Electric Submersible Pump;
PP = Peristaltic Pump;
O = Other (Specify)
SAMPLING DATA
SA M PLED B Y (PRINT) / AFFILIATION: David L. Anderson/CDM
SAMPLER(S) SJGNATURE(S):
SAMPLING INITIATED AT:
SAMPLING Y G ENDED AT:
PU M P DEPTH IN W ELL (feet): UNK
FIELD DECONTAMINATION:
PUMP: No
TUBING MATERIAL CODE: NA
TUBING: NA
FIELD-FILTERED: No Filtration Eguipment Type:
DUPLICATE:
NA
FILTER SIZE: No
NA
urn
SAM PLE CONTAINER SPECIFICATION
SAMPLE ID CODE
NA
# CONTAINERS
2
MATERIAL CODE
PE
VOLUME 1liter
SAMPLE PRESERVATION
PRESERVATIVE USED
None
TOTAL VOL ADDED IN FIELD (mL)
None
FINAL pH NA
INTENDED ANALYSIS AND/OR
METHOD
PFOA, PFOS, &
SAMPLING EQUIPMENT
CODE
O-Grab
SAMPLE PUMP FLOW RATE
(mL per minute)
<100 mL
Fluorlnated Cmps
by HPLC/MS.
REMARKS: NA - Not Applicable.
UNK - Unknown.
Was the well pumping (active) prior to sampling -(Yes) or No.
MS/MSD sample collected - Yes or (N o ) Collection Time:
Well has fluoride treatment - Yes
Photograph No. 3
c ft r .'A j
/8<5' .
MATERIAL CODES:
A G = Amber Glass; CG = Clear Glass; PE = Polyethylene; PP = Polypropylene; S = Silicone; T =Teflon; O = Other (Specify)
'M P LIN G EQUIPMENT CODES: APP = After Peristaltic Pump;
B = Bailer; B P = Bladder Pump; E SP = Electric Submersible Pump;
RFPP = Reverse Flow Peristaltic Pump; SM = Straw Method (Tubing Gravity Drain); O = Other (Grab)
N o TES: 1. The above do not constitute all of the information required by Chapter 62-160, F.A.C. 2. S t a b iliza t io n C r it e r ia f o r r a n g e o f v a r ia t io n o f l a s t t h r e e c o n s e c u t iv e r e a d in g s (s e e F S 2212. s e c t io n 3)
pH: +0.2 units Temperature: + 0.2 C Specific Conductance: + 5% Dissolved Oxygen: all readings <20% saturation (see Table F S 2200-2), optionally, + 0.2 mg/L or + 10% (whichever is greater) Turbidity: all readings <20 NTU; optionally +5 NTU or + 10% (whichever is greater)
Revision Date: February 12, 2009
I W i l l i W W W W V 'fc*T
GROUNDWATER SAMPLING LOG
SITE NAME: ECUA Water Distribution Svstem (Countv-wide)
/ELL NO: /\!\cC&f~f
SAMPLE ID:
SITE LOCATION: Escambia Countv, Florida
DATE: February 2. ,2010
PURGING DATA
WELL CASING
TUBING
WELL SCREEN INTERVAL
PUMPING WATER
DIAMETER (inches): U J V K DIAMETER (inches): NA
DEPTH:
UNK
LEVEL (feet): UNK
W ELL VOLUME PURGE: 1 W ELL VOLUME = (TOTAL WELL DEPTH - STATIC DEPTH TO WATER) X WELL CAPACITY
(only fill out if applicable) qallons
= ( (2 / 0
feet -
UNK
feet) X
EQUIPMENT VO LU M E PURGE: 1 EQUIPMENT VOL. = PUM P VOLUME + (TUBING CAPACITY
(only fill out if applicable)
= gallons + (
gallons/foot X
feet) +
PURGE PUMP TYPE: Existing Pump gallons/foot =
gallons
gallons
PU M P DEPTH IN W ELL (feet): UNK
TIME (CST)
VOLUME PURGED (gallons)
CUMUL. VOLUME PURGED (gallons)
Q r7 6 8 5 " (t>
FINAL PUMP DEPTH IN W ELL (feet): UNK
PURGING
PURGING
INITIATED AT: 8 e/Ci ENDED AT:
PURGE RATE
(gpm)
ORP (mV)
SV2 S '//
pH (standard
units)
TEMP. (C)
? -0 /
.- il
2 !-2 < z
COND. (pS/cm)
//
/// //o
DISSOLVED OXYGEN (mg/L)
7 - il T -./o
TOTAL VOLUME PURGED (gallons):
TURBIDITY (NTUs)
COLOR (describe)
ODOR (describe)
2 -,
Clear
None
Clear
None
Clear
None
o
.,E L L CAPACITY (Gallons Per Foot): 0.75" = 0.02; 1" = 0.04; 1.25" = 0.06; 2" = 0.16; 3" = 0.37; 4" =0.65; 5" = 1.02; 6" = 1.47; 12" = 5.88
TUBING INSIDE DIA. CA PA CITY (Gal./Ft.): 1/8" = 0.0006; 3/16* = 0.0014; 1/4" = 0,0026; 5/16" = 0.004;
3/8" = 0.006; 1/2" =0,010; S/8" =0.016
PURGING EQUIPMENT CODES: B = Bailer; B P = Bladder Pump;
E S P = Electric Submersible Pump;
P P a Peristaltic Pump; O = Other (Specify)
SAMPLING DATA
SAM PLED BY (PRINT) / AFFILIATION: David L. Anderson/CDM
SAMPLER(S) SIGNATURE(S):
SAMPLING A D _ n INITIATED AT: O i 8
SAMPLING ENDED AT:
PU M P DEPTH IN W ELL (feet): UNK
FIELD DECONTAMINATION:
PUMP: No
TUBING MATERIAL CODE: NA
TUBING: NA
FIELD-FILTERED: No Filtration Equipment Type: NA
DUPLICATE:
FILTER SIZE: No
NA
urn
SAMPLE CONTAINER SPECIFICATION
SAMPLE ID CODE
NA
# CONTAINERS
2
MATERIAL CODE
PE
VOLUME I liter
SAMPLE PRESERVATION
PRESERVATIVE USED
None
TOTAL VOL ADDED IN FIELD (mL)
None
FINAL pH NA
INTENDED ANALYSIS AND/OR
METHOD
PFOA, PFOS, &
SAMPLING EQUIPMENT
CODE
O-Grab
SAMPLE PUMP FLOW RATE
(mL per minute)
<100 mL
Fluorlnated Cm ps
by HPLC/MS.
REMARKS: NA - Not Applicable.
UNK - Unknown.
W as the well pumping (active) prior to sampling ^ V e i) or No.
MS/MSD sample collected - Yes or Cno3Collection Time:
Well has fluoride treatment - Yes t^No)
Photograph No.
C A Tr<y
/fiO .
MATERIAL CODES:
A G =Amber Glass; CG = Clear Glass; P E = Polyethylene; PP = Polypropylene; S = Silicone; T = Teflon; O = Other (Specify)
' '.MPLING EQUIPMENT CODES: A PP = After Peristaltic Pump;
B = Bailer; BP = Bladder Pump; E SP = Electric Submersible Pump;
RF P P = Reverse Flow Peristaltic Pump; SM = Straw Method (Tubing Gravity Drain); O = Other (Grab)
NOTES: 1. The above do not constitute all of the information required by Chapter 62-160, F.A.C.
2. S t a b iliz a t io n C r it e r ia f o r r a n g e o f v a r ia t io n o f l a s t t h r e e c o n s e c u t iv e r e a d in g s (s e e F S 2212. s e c t io n 3)
pH: +0 .2 units Temperature: +0 .2 C Specific Conductance: + 5 % Dissolved Oxygen: all readings < 2 0 % saturation (see Table F S 2 2 0 0 -2 ); optionally, + 0 .2 mg/L or + 1 0 % (whichever is greater) Turbidity: all readings < 2 0 NTU; optionally + 5 NTU or + 10 % (whichever is greater)
Revision Date: February 12, 2009
ru m i I u 9uuv6^
GROUNDWATER SAMPLING LOG
SITE I NAME: ECUA Water Distribution System (County-wide)
SITE LOCATION: Escambia County, Florida
/ELL NO: P U f l A W f y f
SAMPLE ID:
DATE: February 2 . ,2010
PURGING DATA
WELL CASING
-7 .
DIAMETER (inches):
TUBING DIAMETER (Inches): NA
WELL SCREEN INTERVAL
DEPTH:
UNK
PUMPING WATER LEVEL (feet): UNK
PU RG E PUMP TYPE: Existing Pump
W ELL VOLUME PURGE: 1 W ELL VOLUME = (TOTAL WELL DEPTH - STATIC DEPTH TO WATER) X WELL CAPACITY
(only fill out if applicable)
_ ,, __
gallons
=(
feet -
UNK
feet) X
gallons/foot =
EQUIPMENT VOLUME PURGE: 1 EQUIPMENT VOL. = PUMP VOLUME + (TUBING CAPACITY X TUBING LENGTH) + FLOW CELL VOLUME
(only fill out if applicable)
= gallons + (
gallons/foot X
feet) +
gallons =
gallons
PUM P DEPTH IN W ELL (feet): UNK
TIME (CST)
VOLUME PURGED (gallons)
CUMUL. VOLUME PURGED (gallons)
0 ?z/
J2^b
FINAL PUMP DEPTH IN W ELL (feet): UNK
PURGING INITIATED AT:. 0 ? / g
PURGE RATE (gpm)
ORP (mV)
pH (standard
units)
TEMP. (C)
COND. (pS/cm)
341
3^ 0
f.ff
S',i l
2 *1 1 -
II
PURGING ENDED AT:
DISSOLVED OXYGEN (mg/L)
J f-f1 y .& f
4 -1 1
TOTAL VOLUME PURGED (gallons):
TURBIDITY (NTUs)
COLOR (describe)
ODOR (describe)
c
Clear
None
Clear
None
0
Clear
None
./ELL CAPACITY (Gallons Per Foot): 0.75" = 0.02; 1" = 0.04; 1.25" = 0.06; 2" = 0.16; 3" = 0.37; 4" = 0.65; 5" = 1.02; 6" = 1.47; 12" = 5.88 TUBING INSIDE DIA. CAPACITY(Gal./Ft.): 1/8" = 0.0006; 3716" = 0.0014; 1/4" = 0,0026; 5/16" = 0.004; 3/8" = 0.006; 1/2" = 0,010; S/8' = 0.016
PURGING EQUIPMENT CODES: B = Bailer;
SAM PLED BY (PRINT) / AFFILIATION: David L. Anderson/CDM
BP = Bladder Pump;
ESP = Electric Submersible Pump;
PP = Peristaltic Pump;
SAMPLING DATA
&LER(S1SIGNATURE(S):
SAMPLING
INITIATED AT: C>12-1
O = Other (Specify)
SAMPLING ENDED AT:
PUM P DEPTH IN W ELL (feet): UNK
TUBING MATERIAL CODE: NA
FIELD-FILTERED: No
FILTER SIZE: NA urn
Filtration Equipment Type: NA
FIELD DECONTAMINATION:
PUMP: No
TUBING: NA
DUPLICATE:
No
SAMPLE CONTAINER SPECIFICATION
SAMPLE ID CODE
NA
# CONTAINERS
2
MATERIAL CODE
PE
VOLUME I liter
SAMPLE PRESERVATION
PRESERVATIVE USED
None
TOTAL VOL ADDED IN FIELD (mL)
None
FINAL
PH NA
INTENDED ANALYSIS AND/OR
METHOD
PFOA, PFOS, &
Fluorinated Cmps
SAMPLING EQUIPMENT
CODE
O-Grab
SAMPLE PUMP FLOW RATE
(mL per minute)
<100 m L
by HPLC/MS.
REMARKS: NA - Not Applicable.
Was the well pumping (active) prior to sampling ^'S'es^ or No.
UNK - Unknown. MS/MSD sample collected - Yes orjfNoJ) Collection Time:
Well has fluoride treatment - Yes c^fNo)
Photograph No.
C-A-Tm*
/ S 'z '.
MATERIAL CODES:
AG = Amber Glass; CG = Clear Glass; PE = Polyethylene; PP = Polypropylene; S = Silicone; T = Teflon; O = Other (Specify)
\MPLING EQUIPMENT CODES: APP = After Peristaltic Pump;
B = Bailer; B P = Bladder Pump; E SP = Electric Submersible Pump;
R FPP = Reverse Flow Peristaltic Pump; SM = Straw Method (Tubing Gravity Drain); O = Other (Grab)
NOTES: 1. The above do not constitute all of the Information required by Chapter 62-160, F.A.C.
2. STA B ILIZA TIO N C R IT E R IA FO R RANGE O F VARIATION O F LA ST T H R E E C O N SE C U T IV E READIN G S (S E E F S 2 2 1 2 , SECTIO N 3)
pH: + 0.2 units Temperature: + 0.2 C Specific Conductance: +5% Dissolved Oxygen: all readings <20% saturation (see Table FS 2200-2); optionally, +0.2 mg/Lor + 10% (whichever is greater) Turbidity: all readings <20 NTU; optionally + 5 NTU or + 10% (whichever is greater)
Revision Date: February 12, 2009
r u m i r l/ cw w v - .t
GROUNDWATER SAMPLING LOG
I SITE I NAME: ECU A Water Distribution System (County-wide)
SITE LOCATION: Escambia County, Florida
/ELL NO:
SAM PLE ID: -
DATE: February 2 . ,2010
PURGING DATA
WELL CASING
o
TUBING
WELL SCREEN INTERVAL
PUMPING WATER
PURGE PUMP TYPE:
DIAMETER (Inches): ^ U
DIAMETER (inches): NA
DEPTH:
UNK
LEVEL (feet): UNK
Existing Pump
W ELL VOLUM E PURGE: 1 W ELL VOLUME = (TOTAL W ELL DEPTH - STATIC DEPTH TO WATER) X WELL CAPACITY
(only fill out if applicable)
gallons
=( 3 7 S
feet -
UNK
EQUIPMENT VO LUM E PURGE: 1 EQUIPMENT VOL. = PUMP VOLUME + (TUBING CAPACITY
feet) X
gallons/foot =
X TUBING LENGTH) + FLOW CELL VOLUME
(only fill out If applicable)
gallons + (
gallons/foot X
feet) +
gallons
gallons
PU M P DEPTH IN W ELL (feet): UNK
TIME (CST)
VOLUME PURGED (gallons)
CUMUL. VOLUME PURGED (gallons)
^ 71/
Cb W
FINAL PUMP DEPTH IN W ELL (feet): UNK
PURGING
^ o /A
INITIATED AT: W ' O
PURGE RATE
(gpm)
ORP (mV)
L 'o V ---
pH (standard
units)
TEMP. (C)
L -tv
2 < S.Zg 2 C .-2 8
COND. (pS/cm)
3V
35
-- L .U h
PURGING ENDED AT: DISSOLVED OXYGEN
(mg/L)
A /-? 7
TOTAL VOLUME PURGED (gallons):
TURBIDITY COLOR
(NTUs)
(describe)
ODOR (describe)
O
Clear
None
O
Clear
None
Clear
None
WELL CAPACITY (Gallons Per Foot): 0.75" = 0.02; 1" = 0.04; 1.25" = 0.06; 2 " = 0.16; 3" = 0,37; 4" =0.65; 5" =1.02; 6" =1.47; 12" = 5.88
TUBING INSIDE DIA. CAPACITY (Gal./Ft.): 1/8" = 0.0006: 3/16" = 0.0014; 1/4" = 0.0026; 5/16" = 0.004;
3/8" =0.006; 1/2" = 0.010; 5/6" = 0.016
PURGING EQUIPMENT CODES: B = Bailer; BP = Bladder Pump;
ESP = Electric Submersible Pump;
PP = Peristaltic Pump;
O = Other (Specify)
SAMPLING DATA
SAM PLED B Y (PRINT) / AFFILIATION: David L. Anderson/CDM
SAMPLER(S) SIGNATURE(S):
SAMPLING
3INITIATED AT: O '7 7
SAMPLING ENDED AT:
PU M P DEPTH IN W E LL (feet): UNK
FIELD DECONTAMINATION:
PUMP: No
TUBING MATERIAL CODE: NA
TUBING: NA
FIELD-FILTERED: No Filtration Equipment Type:
DUPLICATE:
NA
FILTER SIZE: No
NA
urn
SAM PLE CONTAINER SPECIFICATION
SAMPLE ID CODE
NA
CONTAINERS 2
MATERIAL CODE
PE
VOLUME 1liter
SAMPLE PRESERVATION
PRESERVATIVE USED
None
TOTAL VOL ADDED IN FIELD (mL)
None
FINAL PH
NA
INTENDED ANALYSIS AND/OR
METHOD
PFOA, PFOS, &
SAMPLING EQUIPMENT
CODE
O-Grab
SAMPLE PUMP FLOW RATE
(mL per minute)
<100 m L
Fluorinated Cmps
by HPLC/MS.
REMARKS: NA - Not Applicable.
UNK - Unknown.
Was the well pumping (active) prior to sampling -^ e ^ or No.
MS/MSD sample collected - Yes or (Ncp Collection Time:
Well has fluoride treatment - Yes o{fio)
Photograph No. (p
C A . r r i \ r W t* * / S '-2- '.
MATERIAL CODES:
AG = Amber Glass; CG = Clear Glass; PE = Polyethylene; PP = Polypropylene; S = Silicone; T =Teflon; O = Other (Specify)
\M PLIN G EQ UIPM EN T CODES: A PP = After Peristaltic Pump;
B = Bailer; B P = Bladder Pump; E S P = Electric Submersible Pump;
RFPP = Reverse Flow Peristaltic Pump; SM = Straw Method (Tubing Gravity Drain); O = Other (Grab)
NOTES: 1. The above do not constitute all of the information required by Chapter 62-160, F.A.C.
2. S T A B I L I Z A T I O N C R I T E R I A F O R R A N G E O F V A R IA T IO N O F L A S T T H R E E C O N S E C U T I V E R E A D I N G S ( S E E F S 2212. S E C T IO N 3)
pH: + 0.2 units Temperature: + 0.2 C Specific Conductance: + 5% Dissolved Oxygen: all readings < 20% saturation (see Table FS 2200-2); optionally, + 0.2 mg/L or + 10% (whichever is greater) Turbidity: all readings <20 NTU; optionally + 5 NTU or + 10% (whichever is greater)
Revision Date: February 12, 2009
rw i n i r i/ ouvvA .-r
GROUNDWATER SAMPLING LOG
p. 72
I SITE I NAME: ECUA Water Distribution System (Countv-wide)
SITE LOCATION: Escambia Countv, Florida
ELL NO: , - / / i > A
SAMPLE ID: ^ P r U J
DATE: February J 2 . , 2010
PURGING DATA
WELL CASING
,
DIAMETER (Inches): -C. (o
TUBING DIAMETER (inches): NA
WELL SCREEN INTERVAL
DEPTH:
UNK
PUMPING WATER LEVEL (feet): UNK
PURGE PUMP TYPE: Existing Pump
W ELL VOLUME PURGE: 1 W ELL VOLUME = (TOTAL WELL DEPTH - STATIC DEPTH TO WATER) X WELL CAPACITY
(only fill out if applicable) gallons
n s, _ _
=(
feet-
UNK
feet) X
gallons/foot =
EQUIPMENT VOLUME PURGE: 1 EQUIPMENT V O L = PUMP VOLUME + (TUBING CAPACITY
TUBING LENGTH) + FLOW CELL VOLUME
(only fill out If applicable)
= gallons + (
gallons/foot X
feet) +
gallons =
gallons
PUM P DEPTH IN W ELL (feet): UNK
TIME (CST)
VOLUME PURGED
(gallons)
CUMUL. VOLUME PURGED (gallons)
o?^6
oJS1
/be>2-
FINAL PUMP DEPTH IN W ELL (feet): UNK
PURGING
._,,
INITIATED AT:
PURGE RATE (gpm)
ORP (mV)
/b 3 /-/V?
--
pH (standard
units)
T-43-
TEMP. (C)
22-2.
Z 2 .Z xy
2223
COND. (pS/cm)
/6 ??
PURGING ENDED AT:
DISSOLVED OXYGEN (mg/L)
/-VS y-s'? y-s\
TOTAL VOLUME PURGED (gallons):
TURBIDITY (NTUs)
COLOR (describe)
ODOR (describe)
O
Clear
None
O
Clear
None
Clear
None
W ELL CAPACITY (Gallons Per Foot): 0.75" = 0.02; 1" = 0.04; 1.25" = 0.06; 2" = 0.16; 3" = 0.37; 4" =0.65; 5" = 1.02; 6" = 1.47; 12" =5.88 TUBING INSIDE DIA. CA PA CITY (GaliFt.): 1/B" = 0.0006; 3/16" = 0.0014; 1/4" = 0,0026; 6/16* = 0.004; 3/6" = 0.006; 1/2" = 0.010; 5/6" =0.016
PURGING EQUIPMENT CODES: B = Bailer; B P = Bladder Pump;
E S P = Electric Submersible Pump;
PP = Peristaltic Pump;
0 = Other (Specify)
SAMPLING DATA
SAM PLED BY (PRINT) / AFFILIATION: David L. AndersorVCDM
SAMPLER(S) SIGNATURE(S):
SAMPLING . , INITIATED AT: / O & i
SAMPLING ENDED AT:
PU M P DEPTH IN W ELL (feet): UNK
TUBING MATERIAL CODE: NA
FIELD-FILTERED: No
FILTER SIZE: NA
Filtration Equipment Type: NA
am
FIELD DECONTAMINATION: PUMP: No
TUBING: NA
DUPLICATE:
No
SAMPLE CONTAINER SPECIFICATION
SAMPLE ID CODE
NA
# CONTAINERS
2
MATERIAL CODE PE
VOLUME 1 liter
SAMPLE PRESERVATION
PRESERVATIVE USED
None
TOTAL VOL ADDED IN FIELD (mL)
None
FINAL pH NA
INTENDED ANALYSIS AND/OR
METHOD
PFOA, PFOS, &
Fluorinated Cmps
SAMPLING EQUIPMENT
CODE
O-Grab
SAMPLE PUMP FLOW RATE
(mL per minute)
<100 mL
by HPLC/MS.
REMARKS: NA - Not Applicable.
UNK - Unknown.
Was the well pumping (active) prior to sampling -(Ye|) or No.
MS/MSD sample collected - Yes or (No) Collection Time:
Well has fluoride treatment -(^Y^or No.
Photograph No. ^j-
C A i\ 'A 5 d'epfl' /Ob .
MATERIAL CODES:
A G = Amber Glass; CG = Clear Glass;
PE = Polyethylene;
PP = Polypropylene; S = Silicone; T =Teflon; O = Other (Specify)
'MPLING EQUIPMENT CODES:
A P P = After Peristaltic Pump;
B = Bailer; B P = Bladder Pump; ESP = Electric Submersible Pump;
RFPP = Fleverse Flow Peristaltic Pump; SM = Straw Method (Tubing Gravity Drain); O = Other (Grab)
N O TES: 1. The above d o not constitute ail of the information required by Chapter 62-160, F.A.C. 2. S t a b iliza tio n C r it e r ia f o r r a n g e o f v a r ia t io n o f l a s t t h r e e c o n s e c u t iv e r e a d i n g s (s e e FS 2212, s e c t io n 3)
pH: + 0.2 units Temperature: + 0.2 C Specific Conductance: + 5% Dissolved Oxygen: all readings <20% saturation (see Table FS 2200-2); optionally, + 0.2 mg/Lor + 10% (whichever is greater) Turbidity: all readings <20 NTU; optionally +5 NTU or + 10% (whichever is greater)
Revision Date: February 12, 2009
ru m i r u wuu-t*t
GROUNDWATER SAMPLING LOG
p 73
I SITE I NAME: ECUA Water Distribution System (County-wide)
SITE LOCATION: Escambia County, Florida
'E L L NO: / / ^
SAM PLE ID: 7 > * / v 4 J
DATE: February 2 - ,2010
PURGING DATA
WELL CASING
, TUBING
W ELL SCREEN INTERVAL
PUMPING WATER
PURGE PUMP TYPE:
DIAMETER (inches): ^ ^ DIAMETER (inches): NA
DEPTH:
UNK
LEVEL (feet): UNK
Existing Pump
WELL VOLUME PURGE: 1 WELL VOLUME = (TOTAL W ELL DEPTH - STATIC DEPTH TO WATER) X W ELL CAPACITY
(only fill out if applicable)
=( 17b
feet -
UNK
gallons
EQUIPMENT VOLUME PURGE: 1 EQUIPMENT VO L = PUM P VO LU M E + (TUBING CAPACITY
feet) X
gallons/foot =
X TUBING LENGTH) + FLOW CELL VOLUME
(only fill out if applicable)
= gallons + (
gallons/foot X
feet) +
gallons =
gallons
PU M P DEPTH IN W ELL (feet): UNK
TIME (CST)
VOLUME PURGED (gallons)
CUMUL. VOLUME PURGED (gallons)
/ o (p
/6 o ?
/ 0 / 2.
FINAL PUMP DEPTH IN WELL (feet): UNK
PURGING INITIATED AT:
3
PURGE RATE (gpm)
ORP (mV)
(s>*q
L --
pH (standard
units)
TEMP. (C)
3-/7
-2o + I- 3 I
i- n
COND. (pS/cm)
-2 - / 8 2 .3 % 2-2. g
PURGING ENDED AT:
DISSOLVED OXYGEN (mg/L)
3 .2 2 .
3 ./< *
IIS
TOTAL VOLUME PURGED (gallons):
TURBIDITY (NTUs)
COLOR (describe)
ODOR (describe)
3
Clear
None
Z.
Clear
None
2
Clear
None
</ELL CAPACITY (Gallons Per Foot): 0.75" =0.02; 1" = 0.04; 1.25" = 0.06; 2" = 0.16; 3'' = 0.37; 4" = 0.65; 5" = 1.02; 6" = 1.47; 12" = 5.88 TUBING INSIDE DIA. CAPACITY (Gal./Ft ): 1/8" = 0.0006; 3/16" = 0.0014; 1/4" = 0.0026; 5/16" = 0.004; 3/8" = 0.006; 1/2" = 0.010; 5/8" = 0.016
PURGING EQUIPMENT CODES: B = Bailer; BP = Bladder Pump;
ESP = Electric Submersible Pump;
PP = Peristaltic Pump;
O = Other (Specify)
SAMPLING DATA
SAM PLED B Y (PRINT) / AFFILIATION: David L. Anderson/CDM
SAMPLER(S) SIGNATURE(S):
SAMPLING .
INITIATED AT: / O S
SAMPLING ENDED AT:
PU M P DEPTH IN W ELL (feet): UNK
FIELD DECONTAMINATION:
PUMP: No
TUBING MATERIAL CODE: NA
TUBING: NA
FIELD-FILTERED: No Filtration Equipment Type:
DUPLICATE:
NA
FILTER SIZE: No
NA
urn
SAM PLE CONTAINER SPECIFICATION
SAMPLE ID CODE
NA
# CONTAINERS
2
MATERIAL CODE
PE
VOLUME 1liter
SAMPLE PRESERVATION
PRESERVATIVE USED
None
TOTAL VOL ADDED IN FIELD (mL)
None
FINAL pH NA
INTENDED ANALYSIS AND/OR
METHOD
PFOA, PFOS, &
SAMPLING EQUIPMENT
CODE
O-Grab
SAMPLE PUMP FLOW RATE
(mL per minute)
<100 mL
Fluorinated Cmps
by HPLC/MS.
REMARKS: NA - Not Applicable.
UNK - Unknown.
Was the well pumping (active) prior to sampling ^3el) or No.
MS/MSD sample collected - Yes or^ N o3 Collection Time:
Well has fluoride treatment
or No.
Photograph No. ^
c A i'fA j
/ 0 6 '
MATERIAL CODES:
A G = Amber Glass; C G = Clear Glass; P E = Polyethylene: PP = Polypropylene; S = Silicone; T = Teflon; O = Other (Specify)
' AMPLING EQUIPMENT CODES: A P P = After Peristaltic Pump;
B = Bailer; B P = Bladder Pump; E S P = Electric Submersible Pump;
RFPP = Reverse Flow Peristaltic Pump; SM = Straw Method (Tubing Gravity Drain); 0 = Other (Grab)
NOTES: 1. The above do not constitute all of the information required by Chapter 62-160, F.A.C.
2. S t a b iliz a t io n C r it e r ia f o r r a n g e o f v a r ia t io n o f l a s t t h r e e c o n s e c u t iv e r e a d in g s (s e e F S 2212. s e c t io n 3)
pH: + 0.2 units Temperature: + 0.2 C Specific Conductance: +5% Dissolved Oxygen: all readings < 20% saturation (see Table FS 2200-2); optionally, + 0.2 mg/L or + 10% (whichever Is greater) Turbidity: all readings < 20 NTU; optionally + 5 NTU or + 10% (whichever is greater)
Revision Date: February 12, 2009
I W illi I U W W W 't T
GROUNDWATER SAMPLING LOG
PTM
SITE NAME: ECUA Water Distribution System (County-wide)
SITE LOCATION: Escambia Countv. Florida
/ELL NO: f C , 1 J o A
SAM PLE ID:
DATE: February 2 . ,2010
PURGING DATA
WELL CASING
_ 1 TUBING
DIAMETER (inches):
' DIAMETER (inches): NA
WELL SCREEN INTERVAL
DEPTH:
UNK
PUMPING WATER LEVEL (feet): UNK
PURGE PUMP TYPE: Existing Pump
W ELL VOLUME PURGE: 1 W ELL VOLUME = (TOTAL WELL DEPTH - STATIC DEPTH TO WATER) X WELL CAPACITY (only fill out if applicable)
gallons
= ( 2 Jt-I ''
feet-
UNK
feet) X
gallons/foot =
EQUIPMENT VOLUME PURGE: 1 EQUIPMENT VOL. = PU M P VOLUME + (TUBING CAPACITY X TUBING LENGTH) + FLOW CELL VOLUME (only fill out if applicable)
= gallons + (
gallons/foot X
feet) +
gallons =
gallons
PUM P DEPTH IN WELL (feet): UNK
TIME (CST)
VOLUME PURGED (gallons)
CUMUL. VOLUME PURGED (gallons)
/c>3 3
/c> 3&
/o ?T
FINAL PUMP DEPTH IN WELL (feet): UNK
PURGING
,-
PURGING
INITIATED AT: / S 0 ENDED AT:
PURGE RATE
(gpm)
ORP (mV)
3 /6.
pH (standard
units)
f.B G
TEMP. (C)
COND. (pS/cm)
3?
DISSOLVED OXYGEN (mg/L)
3 .7 /
3 7 ^ <r. 8 ?
*7^ 8
37 Vo
3 .7 2 -
3.37
I TOTAL VOLUME | PURGED (gallons):
TURBIDITY (NTUs)
O
COLOR (describe)
Clear Clear Clear
ODOR (describe)
None None None
,/E L L CAPACITY (Gallons Per Foot): 0.75" = 0.02; 1" = 0.04; 1.25" = 0.06; 2" = 0.16; 3" = 0.37; 4" = 0.65; 5" = 1.02; 6" = 1.47; 12" =5.88 TUBING INSIDE DIA. CAPACITY (Gal./Ft.): 1/8" = 0.0006; 3/16" = 0.0014; 1/4" = 0.0026; 5/16" = 0.004; 3/8" = 0.006; 1/2" =0.010; 5/8" = 0.016
PURGING EQUIPMENT CODES: B = Bailer;
SAM PLED BY (PRINT) / AFFILIATION: David L. Andersort/CDM
B P = Bladder Pump;
E S P = Electric Submersible Pump;
PP = Peristaltic Pump;
SAMPLING DATA
SftMPLER(S)SIGNATURE(S):
SAMPLING INITIATED AT: / c <-//
O = Other (Specify)
SAMPLING ENDED AT:
PU M P DEPTH IN W ELL (feet): UNK
TUBING MATERIAL CODE: NA
FIELD-FILTERED: No
FILTER SIZE: NA
Filtration Equipment Type: NA
um
FIELD DECONTAMINATION:
PUMP: No
TUBING: NA
DUPLICATE:
No
SAMPLE CONTAINER SPECIFICATION
SAMPLE ID CODE
NA
# CONTAINERS
2
MATERIAL CODE
PE
VOLUME 1liter
SAMPLE PRESERVATION
PRESERVATIVE USED
None
TOTAL VOL ADDED IN FIELD (mL)
None
FINAL pH NA
INTENDED ANALYSIS AND/OR
METHOD
PFOA, PFOS, &
SAMPLING EQUIPMENT
CODE
O-Grab
SAMPLE PUMP FLOW RATE
(mL per minute)
<100 mL
Fluorlnated Cmps
by HPLC/MS.
REMARKS: NA - Not Applicable.
UNK - Unknown.
Was the well pumping (active) prior to sampling -^ e^ or No.
MS/MSD sample collected
or No. Collection Time: / & * / !
Well has fluoride treatment -^ p> or No.
Photograph No. ^
C A / T n y ft- '' / .j- .
MATERIAL CODES:
A G = Amber Glass; C G = Clear Glass; PE = Polyethylene; P P = Polypropylene; S = Silicone; T = Teflon; O = Other (Specify)
\MPLING EQUIPMENT CODES: A P P = After Peristaltic Pump;
B = Bailer; B P = Bladder Pump; E SP = Electric Submersible Pump;
RFPP = Reverse Flow Peristaltic Pump; SM = Straw Method (Tubing Gravity Drain); 0 = Other (Grab)
NO TES: 1. The above do not constitute all of the information required by Chapter 62-160, F.A.C. 2. S t a b iliza tio n C r it e r ia f o r r a n g e o f v a r ia t io n o f l a s t t h r e e c o n s e c u t i v e r e a d i n g s (s e e FS 2212. s e c t io n 3)
pH: 0.2 units Temperature: 0.2 C Specific Conductance: +5% Dissolved Oxygen: all readings <20% saturation (see Table FS 2200-2); optionally, +0.2 mg/L or 10% (whichever is greater) Turbidity: all readings <20 NTU; optionally 5 NTU or + 10% (whichever is greater)
Revision Date: February 12, 2009
I V I III
h* i / w v ^ - r
GROUNDWATER SAMPLING LOG
SITE NAME: ECUA Water Distribution System (Countv-wide)
SITE LOCATION: Escambia Countv, Florida
/ELL NO:
SAM PLE ID:
DATE: February 2 - ,2010
PURGING DATA
WELL CASING
TUBING
WELL SCREEN INTERVAL
PUMPING WATER
PURGE PUMP TYPE:
DIAMETER (Inches): M 1 DIAMETER (inches): NA
DEPTH:
UNK
LEVEL (feet): UNK
Existing Pump
W ELL VOLUME PURGE: 1 WELL VOLUME = (TOTAL W ELL DEPTH - STATIC DEPTH TO WATER) X WELL CAPACITY
(only fill out If applicable) gallons
= ( 2 / l '
feet-
UNK
feet) X
gallons/foot
EQUIPMENT VOLUM E PURGE: 1 EQUIPMENT V O L = PUMP VOLUME + (TUBING CAPACITY X TUBING LENGTH) + FLOW CELL VOLUME
(only fill out if applicable)
= gallons + (
gallons/foot X
feet) +
gallons =
_
gallons
PUM P DEPTH IN W E LL (feet): UNK
TIME (CST)
VOLUME PURGED (gallons)
CUMUL. VOLUME PURGED (gallons)
/o<-/3
/Q V i /c>
FINAL PUMP DEPTH IN W ELL (feet): UNK
PURGE RATE (gpm)
ORP (mV)
pH (standard
units)
7 .2 /
7 -g fc 1S
1 -2 )
PURGING
, -,
INITIATED AT: / J C b
TEMP. (C)
COND. (gS/cm)
2-3-11
2 3 -/0
So
Sto
PURGING ENDED AT:
DISSOLVED OXYGEN (mg/L)
> 2 3
.2.J
o-ZJ
TOTAL VOLUME PURGED (gallons):
TURBIDITY COLOR
(NTUs)
(describe)
ODOR (describe)
Clear Clear Clear
None None None
-YELL C A PA C IT Y (Gallons Per Foot): 0.75" = 0.02; 1" = 0.04; 1.25" = 0.06; 2" = 0.16; 3" = 0.37; 4" = 0.65; 5" = 1.02; 6" = 1.47; 12" = 5.88 TUBING INSIDE DIA. CAPACITY(Gal./Ft.): 1/8" = 0.0006; 3/16" = 0.0014; 1/4* = 0.0026; 5/16" =0.004; 3/8" = 0.006; 1/2" = 0.010; 5/8" = 0.016
PURGING EQUIPM ENT CODES: B = Bailer;
SAM PLED BY (PRINT) / AFFILIATION: David L. Anderson/CDM
B P = Bladder Pump;
E S P = Electric Submersible Pump;
P P = Peristaltic Pump;
SAMPLING DATA
S&MPLER(S)SIGNATURE(S):
SAMPLING . ^ INITIATED AT: / s
O = Other (Specify)
SAMPLING ENDED AT:
PUM P DEPTH IN W ELL (feet): UNK
TUBING MATERIAL CODE: NA
FIELD-FILTERED; No
FILTER SIZE: NA
Filtration Equipment Type: NA
urn
FIELD DECONTAMINATION:
PUMP: No
TUBING: NA
DUPLICATE:
No
SAMPLE CONTAINER SPECIFICATION
SAMPLE ID CODE
NA
# CONTAINERS
2
MATERIAL CODE
PE
VOLUME 1liter
SAMPLE PRESERVATION
PRESERVATIVE USED
None
TOTAL VOL ADDED IN FIELD (mL)
None
FINAL PH
NA
INTENDED ANALYSIS AND/OR
METHOD
PFOA, PFOS, &
SAMPLING EQUIPMENT
CODE
O-Grab
SAMPLE PUMP FLOW RATE
(mL per minute)
<100 mL
Fluorinated Cmps
by HPLC/MS.
REMARKS: NA - Not Applicable.
UNK - Unknown.
Was the well pumping (active) prior to sampling
or No.
MS/MSD sample c o lle c te c ^ Y ^ or No. Collection Time: / Q Z * /
Well has fluoride treatment -^ ep > r No.
Photograph No. / O
C A / v it j ckf+ Vv
MATERIAL CODES:
A G = Amber Glass; C G = Clear Glass;
PE = Polyethylene;
PP = Polypropylene; S = Silicone; T =Teflon; O = Other (Specify)
'AM P LIN G EQUIPM ENT CODES: APP = After Peristaltic Pump;
B = Bailer; B P = Bladder Pump; ESP = Electric Submersible Pump;
RFPP = Reverse Flow Peristaltic Pump; SM = Straw Method (Tubing Gravity Drain); O = Other (Grab)
NOTES: 1. The above do not constituteall of the Information required by Chapter 62-160, F.A.C.
2 . Stabilization Criteria for range of variation of last three consecutive readings (see F S 2 2 1 2 . section 3 )
pH:+0.2 units Temperature: + 0.2 C Specific Conductance: +5% Dissolved Oxygen: all readings < 20% saturation (see Table FS 2200-2); optionally, + 0.2 mg/L or + 10% (whichever is greater) Turbidity: all readings < 20 NTU; optionally 5 NTU or + 10% (whichever is greater)
Revision Date: February 12, 2009
I V I I I I I ^ < / V W V mm' T
GROUNDWATER SAMPLING LOG
SITE NAME: ECUA Water Distribution System (Countv-wide)
SITE LOCATION: Escambia County. Florida
VELLNO; U j e r f -
SAM PLE ID:
DATE: February 2 . ,2010
PURGING DATA
WELL CASING
y ,,
TUBING
WELL SCREEN INTERVAL
PUMPING WATER
PURGE PUMP TYPE:
DIAMETER (inches): ^ 7
DIAMETER (inches): NA
DEPTH:
UNK
LEVEL (feet): UNK
Existing Pump
WELL VOLUME PURGE: 1 WELL VOLUME = (TOTAL W ELL DEPTH - STATIC DEPTH TO WATER) X WELL CAPACITY
(only fill out If applicable)
aallons
= ( 2 to (p
feet -
UNK
feet) X
gallons/foot =
EQUIPMENT VOLUME PURGE: 1 EQUIPMENT VOL. = PUM P VOLUME + (TUBING CAPACITY X TUBING LENGTH) + FLOW CELL VOLUME
(only fill out It applicable)
= gallons + (
gallons/foot X
feet) +
gallons =
gallons
PU M P DEPTH IN W ELL (feet): UNK
TIME (CST)
VOLUME PURGED
(gallons)
CUMUL. VOLUME PURGED (gallons)
US?
/A T 8
/2 *l
FINAL PUMP DEPTH IN W ELL (feet): UNK
PURGING
,
INITIATED AT; / / > 2 -
PURGE RATE
(SPm)
ORP (mV)
32% --
pH (standard
units)
TEMP. (C)
r. 2 2 2 U
r.? ?
2ZZ* 2 2 .Z &
COND. (pS/cm)
2/
7-2
2 -;
PURGING ENDED AT: DISSOLVED OXYGEN
(mg/L)
r.f ?
<r.<3f
TOTAL VOLUME PURGED (gallons):
TURBIDITY (NTUs)
COLOR (describe)
ODOR (describe)
Co
C le a r
None
C
Clear
None
o
Clear
None
WELL CAPACITY (Gallons Per Foot): 0.75" = 0.02; 1" = 0.04; 1.25" = 0.06; 2" = 0.16; 3" = 0.37; 4" = 0.65; 5" = 1.02; 6" = 1.47; 12" = 5.88 TUBING INSIDE DfA. CAPACITY (Gal./Ft): 1/8" = 0.0006; 3/16" =0.0014; 1/4" = 0.0026; 5/16" = 0.004; 3/8" = 0.006; 1/2" = 0.010; 5/8" = 0.016
PURGING EQUIPMENT CODES: B = Bailer; BP = Bladder Pump;
ESP = Electric Submersible Pump;
PP = Peristaltic Pump;
O = Other (Specify)
SAMPLING DATA
SAM PLED BY (PRINT) / AFFILIATION: David L. Anderson/CDM
SAMPLER(S) SIGNATURE(S):
SAMPLING
.. -
INITIATED AT: / O j
SAMPLING ENDED AT;
PUM P DEPTH IN W ELL (feet): UNK
FIELD DECONTAMINATION:
PUMP; No
TUBING MATERIAL CODE: NA
TUBING: NA
FIELD-FILTERED: No Filtration Equipment Type:
DUPLICATE:
NA
FILTER SIZE: No
NA
urn
SAMPLE CONTAINER SPECIFICATION
SAMPLE IDCODE
NA
# CONTAINERS
2
MATERIAL CODE
PE
VOLUME I liter
SAMPLE PRESERVATION
PRESERVATIVE USED None
TOTAL VOL ADDED IN FIELD (mL)
None
FINAL pH NA
INTENDED ANALYSIS AND/OR
METHOD
PFOA, PFOS, &
Fluorinated Cmps
SAMPLING EQUIPMENT
CODE
O-Grab
SAMPLE PUMP FLOW RATE
(mL per minute)
<100 mL
by HPLC/MS.
REMARKS: NA - Not Applicable.
Was the well pumping (active) prior to sampling - ( e j or No.
UNK - Unknown.
MS/MSD sample collected - Yes or (fto) Collection Time:
Well has fluoride treatment -^ e^ or No.
Photograph No. / j
e f t m s '
MATERIAL CODES:
A G =Amber Glass; C G = Clear Glass; P E = Polyethylene; PP = Polypropylene; S = Silicone; T = Teflon; O = Other (Specify)
'A M P LIN G EQUIPMENT CODES: A P P = After Peristaltic Pump;
B = Bailer; B P = Bladder Pump; ESP = Electric Submersible Pump;
R FPP = Reverse Flow Peristaltic Pump; SM = Straw Method (Tubing Gravity Drain); O =Other (Grab)
N O TES: 1. The above do not constitute all of the Information required by Chapter 62-160, F.A.C. 2 . S t a b i l i z a t i o n C r i t e r i a f o r r a n g e o f v a r i a t i o n o f l a s t t h r e e c o n s e c u t i v e r e a d i n g s (s e e F S 2 2 1 2 . s e c t i o n 3) pH: + 0.2 units Temperature: +0.2 C Specific Conductance: +5% Dissolved Oxygen: all readings <20% saturation (see Table FS 2200-2); optionally, +0.2 mg/L or 10% (whichever is greater) Turbidity: all readings <20 NTU; optionally + 5 NTU or + 10% (whichever is greater)
Revision Date: February 12, 2009
ru m i r u auvu'tn
GROUNDWATER SAMPLING LOG
SITE NAME: ECUA Water Distribution System (County-wide)
SITE LOCATION: Escambia County, Florida
VELLNO:
^ a c /V
SAMPLE ID: - 7 ^ .* 4 < = J
DATE: February 2 _ ,2010
PURGING DATA
WELL CASING
TUBING
WELL SCREEN INTERVAL
PUMPING WATER
PU RGE PUMP TYPE:
DIAMETER (inches):
DIAMETER (inches): NA
DEPTH:
UNK
LEVEL (feet): UNK
Existing Pump
W ELL VOLUME PURGE: 1 W ELL VOLUME = (TOTAL WELL DEPTH - STATIC DEPTH TO WATER) X WELL CAPACITY
(only fill out if applicable)
.
= ( - 2 I t (#
feet -
LINK
gallons
EQUIPMENT VOLUME PURGE: 1 EQUIPMENT VOL. = PUM P VOLUME + (TUBING CAPACITY
feet) X
gallons/foot =
X TUBING LENGTH) + FLOW CELL VOLUME
(only fill out if applicable)
gallons + (
gallons/foot X
feet) +
gallons
PUM P DEPTH IN W ELL (feet): UNK
TIME (CST)
VOLUME PURGED (gallons)
CUMUL. VOLUME PURGED
(gallons)
Z& S
/Zo8
fZ!\
FINAL PUMP DEPTH IN W ELL (feet): UNK
PURGE RATE
(gpm)
ORP (mV)
^8 2 vs / Y8 ?
pH (standard
units)
V*
PURGING INITIATED AT: / / 3 J -
PURGING ENDED AT:
TEMP. (C)
COND. (gS/cm)
DISSOLVED OXYGEN (mg/L)
/& o
3.?*
V/L
/a/
/feo
2 .1 3
TOTAL VOLUME PURGED (gallons):
TURBIDITY (NTUs)
COLOR (describe)
ODOR (describe)
Clear
None
o
Clear
None
O
Clear
None
WELL CAPACITY (Gallons Per Foot): 0.75" = 0.02; 1" =0.04; 1.25" = 0.06; 2" = 0.16; 3" = 0.37; 4" = 0.65; 5" =1.02; 6" =1.47; 12" =5.88 TUBING INSIDE DIA. CAPACITY (Gal./Ft,): 1/8" = 0.0006; 3/16" = 0.0014; 1/4" = 0.0026; S/16" =0.004; 3/8" = 0.006; 1/2" = 0.010; S/8" =0.016
PURGING EQUIPMENT CODES: B = Bailer; BP = Bladder Pump;
ESP = Electric Submersible Pump;
PP = Peristaltic Pump;
O =Other (Specify)
SAMPLING DATA
SAM PLED BY (PRINT) /AFFILIATION: David L. Anderson/CDM
SAMPLER(S)SIGNATURE(S):
SAMPLING . . . . . . INITIATED AT:
SAMPLING ENDED AT:
PU M P DEPTH IN W ELL (feet): UNK
FIELD DECONTAMINATION:
PUMP: No
TUBING MATERIAL CODE: NA
TUBING: NA
FIELD-FILTERED: No Filtration Equipment Type:
DUPLICATE:
NA
FILTER SIZE: No
NA
urn
SAMPLE CONTAINER SPECIFICATION
SAMPLE ID CODE
NA
# CONTAINERS
2
MATERIAL CODE
PE
VOLUME 1liter
SAMPLE PRESERVATION
PRESERVATIVE USED
None
TOTAL VOL ADDED IN FIELD (mL)
None
FINAL PH NA
INTENDED ANALYSIS AND/OR
METHOD
PFOA, PFOS, &
Fluorinated Cmps
SAMPLING EQUIPMENT
CODE
O-Grab
SAMPLE PUMP FLOW RATE
(mL per minute)
<100 mL
by HPLC/MS.
REMARKS: NA - Not Applicable.
UNK - Unknown.
Was the well pumping (active) prior to sampling
or No.
MS/MSD sample collected - Yes or ( nq ) Collection Time:
Well has fluoride treatment
or No.
Photograph No. / 2.
C A jV n y
Fti
MATERIAL CODES:
/V S '/. A G =Amber Glass; C G =Clear Glass;
P E =Polyethylene;
PP =Polypropylene; S = Silicone; T =Teflon; O =Other (Specify)
' AMPLING EQUIPMENT CODES: A P P = After Peristaltic Pump;
B = Bailer; B P = Bladder Pump; ESP = Electric Submersible Pump;
RFPP = Reverse Flow Peristaltic Pump; SM = Straw Method (Tubing Gravity Drain); O = Other (Grab)
NOTES: 1. The above d o not constitute all of the information required by Chapter 62-160, F.A.C. 2. S t a b il iz a t io n C r it e r ia f o r r a n g e o f v a r ia t io n o f l a s t t h r e e c o n s e c u t i v e r e a d i n g s (s e e FS 2212. s e c t io n 3)
pH: +0.2 units Temperature: + 0.2 C Specific Conductance: +5% Dissolved Oxygen: all readings <20% saturation (see Table FS 2200-2); optionally, + 0.2 mg/L or + 10% (whichever is greater) Turbidity: all readings < 20 NTU; optionally +5 NTU or + 10% (whichever is greater)
Revision Date: February 12, 2009
rumi ru
GROUNDWATER SAMPLING LOG
I SITE I NAME: ECUA Water Distribution System (Countv-wide)
SITE LOCATION: Escambia County, Florida
ELL NO: U j o' / \ U w ^
SAM PLE ID:
DATE: February 2 . , 2010
PURGING DATA
WELL CASING
,
DIAMETER (Inches): 2
TUBING DIAMETER (Inches): NA
WELL SCREEN INTERVAL
DEPTH:
UNK
PUMPING WATER LEVEL (feet): UNK
PURGE PUMP TYPE: Existing Pump
W ELL VOLUME PURGE: 1 W ELL VOLUME = (TOTAL WELL DEPTH - STATIC DEPTH TO WATER) X WELL CAPACITY
(only fill out If applicable)
qallons
= ( 2 -S 1
feet -
UNK
feet) X
gallons/foot =
EQUIPMENT VOLUME PURGE: 1 EQUIPMENT VOL. = PUMP VOLUME + (TUBING CAPACITY X TUBING LENGTH) + FLOW CELL VOLUME
(only fill out if applicable)
= gallons + (
gallons/foot X
feet) +
gallons =
gallons
PUM P DEPTH IN W ELL (feet): UNK
TIME (CST)
VOLUME PURGED (gallons)
CUMUL. VOLUME PURGED (gallons)
tZZS
/2 2
FINAL PUMP DEPTH IN W ELL (feet): UNK
PURGE RATE (gpm)
ORP (m V )
-- --
pH (standard
units)
sr.?*
PURGING
.
INITIATED AT: / Z 2 2 .
TEMP. (C)
COND. (pS/cm)
22-^3 22-&T-
/ O (o /OS'
PURGING ENDED AT: DISSOLVED OXYGEN
(mg/L)
* 31
TOTAL VOLUME PURGED (gallons):
TURBIDITY (NTUs)
COLOR (describe)
ODOR (describe)
/
Clear
None
o
Clear
None
JZV
-- S'. 1-1
/o?-
* 27
/
Clear
None
./ELL CAPACITY (Gallons Per Foot): 0.75" = 0.02; 1" = 0.04; 1.25" = 0.06; 2" = 0.16; 3" = 0.37; 4" = 0.65; 5" =1.02; 6" = 1.47; 12" = 5.88
TUBING INSIDE DIA. CAPACITY (GalVFt ): 1/8" =0.0006: 3/16" = 0.0014; 1/4" = 0.0026; 5116" =0.004;
3/8" = 0.006; 1/2" =0.010; 5/8" = 0.016
PURGING EQUIPMENT CODES: B = Bailer; BP = Bladder Pump;
ESP = Electric Submersible Pump;
PP = Peristaltic Pump;
0 = Other (Specify)
SAMPLING DATA
SAM PLED BY (PRINT) / AFFILIATION: David L. Anderson/CDM
SAMPLER(S) SIGNATURE(S):
SAMPLING
n
INITIATED AT: / S Y
SAMPLING ENDED AT:
PU M P DEPTH IN W ELL (feet): UNK FIELD DECONTAMINATION: PUMP: No
TUBING MATERIAL CODE: NA
TUBING: NA
FIELD-FILTERED: No Filtration Equipment Type:
DUPLICATE:
NA
FILTER SIZE: No
NA
urn
SAM PLE CONTAINER SPECIFICATION
SAMPLE IDCODE
NA
if CONTAINERS
2
MATERIAL CODE
PE
VOLUME 1liter
SAMPLE PRESERVATION
PRESERVATIVE USED
None
TOTAL VOL ADDED IN FIELD (mL)
None
FINAL pH NA
INTENDED ANALYSIS AND/OR
METHOD
PFOA, PFOS, &
SAMPLING EQUIPMENT
CODE
O-Grab
SAMPLE PUMP FLOW RATE
(mL per minute)
<100 mL
Fluorinated Cmps
by HPLC/MS.
REMARKS: NA - Not Applicable.
UNK - Unknown.
Was the well pumping (active) prior to sampling
or No.
MS/MSD sample collected -Yes or (iQoj Collection Time:
Well has fluoride treatment-^Ye^ or No.
Photograph No. 1 3
c a /v a ? MATERIAL CODES:
/ f t 1AG =Amber Glass; CG = Clear Glass;
PE = Polyethylene;
PP = Polypropylene; S = Silicone; T =Teflon; O = Other (Specify)
MPLING EQUIPMENT CODES: APP = After Peristaltic Pump;
B = Bailer; B P = Bladder Pump; E S P = Electric Submersible Pump;
RFPP = Reverse Flow Peristaltic Pump; SM = Straw Method (Tubing Gravity Drain); O = Other (Grab)
NO TES: 1. The above do not constitute all of the information required by Chapter 62-160, F.A.C. 2. STABILIZATION CRITERIA FOR RAN GE O F VARIATION O F LAST THREE CONSECUTIVE READINGS (SEE FS 2 2 1 2 , SECTION 3)
pH: + 0.2 units Temperature: + 0.2 C Specific Conductance: +5% Dissolved Oxygen: all readings <20% saturation (see Table FS 2200-2); optionally, 0.2 mg/L or + 10% (whichever is greater) Turbidity: all readings <20 NTU; optionally 5 NTU or + 10% (whichever is greater)
Revision Date: February 12, 2009
GROUNDWATER SAMPLING LOG
SITE NAME; ECUA Water Distribution System (County-wide)
SITE LOCATION: Escambia County, Florida
VELLNO: \\J c
SAMPLE ID:
DATE; February J L ,2010
PURGING DATA
WELL CASING
_ I TUBING
WELL SCREEN INTERVAL
PUMPING WATER
PURGE PUMP TYPE:
DIAMETER (inches): ^
DIAMETER (inches): NA
DEPTH:
UNK
LEVEL (feet): UNK
Existing Pump
WELL VOLUME PURGE: 1 WELL VOLUME = (TOTAL W ELL DEPTH - STATIC DEPTH TO WATER) X WELL CAPACITY
(only fill out if applicable)
=( j I
feet -
UNK
qallons
EQUIPMENT VOLUME PURGE: 1 EQUIPMENT VOL. = PUMP VOLUME +(TUBING CAPACITY
feet) X
gallons/foot =
X TUBING LENGTH) + FLOW CELL VOLUME
(only fill out if applicable)
= gallons + (
gallons/foot X
feet) +
gallons =
gallons
PU M P DEPTH IN W ELL (feet): UNK
TIME (CST)
VOLUME PURGED (gallons)
CUMUL. VOLUME PURGED (gallons)
un /2</2
FINAL PUMP DEPTH IN W ELL (feet): UNK
PURGING
PURGING
INITIATED AT: / 2 - 2 'z- ENDED AT:
PURGE RATE (gpm)
ORP (mV)
0 4
pH (standard
units)
TEMP. (C)
?-*>? 2 f- Z 7-/0 zhty
COND. (pS/cm)
/sr
DISSOLVED OXYGEN (mg/L)
r.v r
r.xyz
TOTAL VOLUME PURGED (gallons):
TURBIDITY (NTUs)
COLOR (describe)
ODOR (describe)
/
Clear
None
Clear
None
1
Clear
None
,/ELL CAPACITY (Gallons Per Foot): 0.75" = 0.02; 1M= 0.04; 1.25" = 0.06; 2" = 0.16; 3" = 0.37; 4"=0.65; 5" = 1.02; 6" =1.47; 12" = 5.88 TUBING INSIDE DIA. CAPACITY (Gal./Ft.): 1/8" =0.0006; 3/16" =0.0014; 1/4" = 0.0026; 5/16" =0.004; 3/8" = 0.006; 1/2" = 0.010; 8/8" =0.016
PURGING EQUIPMENT CODES: B = Bailer; BP = Bladder Pump;
ESP =Electric Submersible Pump;
PP = Peristaltic Pump;
O =Other (Specify)
SAMPLING DATA
SAM PLED BY (PRINT) / AFFILIATION: David L. Anderson/CDM
SAMPLER(S) SfGNATURE(S):
SAMPLING
,
INITIATED AT: / 2 Z / 3
SAMPLING ENDED AT;
PU M P DEPTH IN W ELL (feet): UNK
FIELD DECONTAMINATION:
PUMP; No
TUBING MATERIAL CODE: NA
TUBING: NA
FIELD-FILTERED: No Filtration Equipment Type:
DUPLICATE:
NA
FILTER SIZE; No
NA
urn
SAMPLE CONTAINER SPECIFICATION
SAMPLE ID CODE
NA
# CONTAINERS
2
MATERIAL CODE
PE
VOLUME 1liter
SAMPLE PRESERVATION
PRESERVATIVE USED
None
TOTAL VOL ADDED IN FIELD (mL)
None
FINAL
PH___ NA
INTENDED ANALYSIS AND/OR
METHOD
PFOA, PFOS, &
SAMPLING EQUIPMENT
CODE
O-Grab
SAMPLE PUMP FLOW RATE
(mL per minute)
<100 mL
Fluorlnated Cmps
by HPLC/MS.
REMARKS: NA - Not Applicable.
UNK - Unknown.
W as the well pumping (active) prior to sampling
or No.
MS/MSD sample collected - Yes or<^Ro> Collection Time:
Well has fluoride treatment
or No.
Photograph No. /
C L A rrn y MATERIAL CODES:
I S 4>' AG = Amber Glass; CG = Clear Glass;
PE = Polyethylene;
PP = Polypropylene; S = Silicone; T =Teflon; O = Other (Specify)
SAM PLING EQUIPMENT CODES: A PP = After Peristaltic Pump;
B = Bailer; B P = Bladder Pump; E SP = Electric Submersible Pump;
R FPP = Reverse Flow Peristaltic Pump; SM = Straw Method (Tubing Gravity Drain); O =Other (Grab)
NOTES: 1. The above do not constituteall of the information required by Chapter 62-160, F.A.C.
2. Stabilization Criteria for range of variation of last three consecutive readings (see FS 2212. section 3)
pH: + 0.2 units Temperature: + 0.2 C Specific Conductance: +5% Dissolved Oxygen: all readings < 20% saturation (see Table FS 2200-2); optionally, + 0.2 mg/L o r + 10% (whichever is greater) Turbidity: all readings < 20 NTU; optionally + 5 NTU or + 10% (whichever is greater)
Revision Date: February 12, 2009
I W illi I W
GROUNDWATER SAMPLING LOG
SITE NAME: ECUA Water Distribution System (County-wide)
SITE LOCATION: Escambia County, Florida
VELLNO: U ie r - P llK M l
SAM PLE ID:
DATE: February " 2 . ,2010
PURGING DATA
WELL CASING
^ i TUBING
DIAMETER (inches):
^ DIAMETER (inches): NA
WELL SCREEN INTERVAL
DEPTH:
UNK
PUMPING WATER LEVEL (feet): UNK
PURGE PUM P TYPE: Existing Pump
W ELL VOLUME PURGE: 1 W ELL VOLUME =(TOTAL W ELL DEPTH - STATIC DEPTH TO WATER) X W ELL CAPACITY
(only fill out If applicable)
=( 2JZ U> fest~ UNK
test) X
gallons/foot =
gallons
EQUIPMENT VOLUME PURGE: 1 EQUIPMENT VOL. =PUM P VOLUME +(TUBING CAPACITY X TUBING LENGTH) +FLOW CELL VOLUME
(only fill out if applicable)
= gallons +(
gallons/foot X
feet) +
gallons =
gallons
PUMP DEPTH INW ELL (feet): UNK
TIME (CST)
VOLUME PURGED (gallons)
CUMUL. VOLUME PURGED (gallons)
/zsi
IZST /3e>2-
FINAL PUMP DEPTH IN W ELL (feet): UNK
PURGING INITIATED A T M 5 5
PURGE RATE (gpm)
ORP (mV)
PH (standard
units)
TEMP. (C)
HT'1 (s -/O 2/i ff ] L-G1- 2/-S
6.-0% ?!?o
COND. (pS/cm)
/o /oy /o?
PURGING ENDED AT:
DISSOLVED OXYGEN (mg/L)
3-61 3.ko
? . 2
TOTAL VOLUME PURGED (gallons):
TURBIDITY (NTUs)
COLOR (describe)
ODOR (describe)
o
Clear
None
o
Clear
None
Clear
None
/ELL CAPACITY (Gallons Per Foot): 0.75" =0.02; 1" = 0.04; 1.25" =0.06; 2" =0.16; 3" =0.37; 4" =0.65; 5" =1.02; 6" = 1.47; 12" =5.88
TUBING INSIDE DIA. CAPACITY (Gai/Ft ): 1/8" =0.0006; 3/16" =0.0014; 1/4" =0.0026; 5/16"=0.004; 3/8" =0.006; 1/2" = 0.010; 5/B" =0.016
PURGING EQUIPMENT CODES: B = Bailer; BP =Bladder Pump;
ESP =Electric Submersible Pump;
PP =Peristaltic Pump;
O =Other (Specify)
SAMPLING DATA
SAMPLED BY (PRINT)/AFFILIATION: David L. Anderson/CDM
SAMPLER(S)jIGNATURE(S):
SAMPLING i~) INITIATED AT: l i Q y
SAMPLING ENDED AT:
PUMP DEPTH IN W ELL (feet): UNK
TUBING MATERIAL CODE: NA
FIELD-FILTERED: No
FILTER SIZE: NA
Filtration Equipment Type: NA
urn
FIELD DECONTAMINATION:
PUMP: No
TUBING: NA
DUPLICATE:
No
SAMPLE CONTAINER SPECIFICATION
SAMPLE ID CODE
NA
# CONTAINERS
2
MATERIAL CODE
PE
VOLUME 1liter
SAMPLE PRESERVATION
PRESERVATIVE USED
None
TOTAL VOL ADDED IN FIELD (mL)
None
FINAL pH NA
INTENDED ANALYSIS AND/OR
METHOD
PFOA, PFOS, &
Fluorinated Cmps
SAMPLING EQUIPMENT
CODE
O-Grab
SAMPLE PUMP FLOW RATE
(mL per minute)
<100 mL
by HPLC/MS.
REMARKS: NA - Not Applicable.
UNK - Unknown.
Was the well pumping (active) prior to sampling-(^esj or No.
MS/MSD sample collected - Yes or fNo3 Collection Time:
Well has fluoride treatment - Yes o^N)
Photograph No. / 5~
C A j V a j - <Ao.F-Fh I I 3 .
MATERIAL CODES:
AG = Amber Glass; CG = Clear Glass; PE = Polyethylene; PP = Polypropylene; S = Silicone; T =Teflon; O = Other (Specify)
'AMPLING EQUIPMENT CODES:
A P P = After Peristaltic Pump;
B = Bailer; B P = Bladder Pump; ESP = Electric Submersible Pump;
RFPP = Reverse Flow Peristaltic Pump; SM = Straw Method (Tubing Gravity Drain); 0 = Other (Grab)
NOTES: 1. The above d o not constitute all of the information required by Chapter 62-160, F.A.C. 2. S t a b il iz a t io n C r it e r ia f o r r a n g e o f v a r ia t io n o f l a s t t h r e e c o n s e c u t i v e r e a d in g s (s e e FS 2212. s e c t io n 3)
p H : +0.2 units Temperature: +0.2 C Specific Conductance: +5% Dissolved Oxygen: all readings <20% saturation (see Table FS 2200-2); optionally, +0.2 mg/L or + 10% (whichever is greater) Turbidity: all readings <20 NTU; optionally 5 NTU or + 10% (whichever Is greater)
Revision Date: February 12, 2009
GROUNDWATER SAMPLING LOG
SITE NAME: ECUA Water Distribution System (County-wide)
SITE LOCATION: Escambia County, Florida
VELLNO: lU c r+ - Ui*-U
SAM PLE ID;
^
DATE: February Z2. ,2010
PURGING DATA
WELL CASING DIAMETER (Inches):
. TUBING DIAMETER (inches): NA
WELL SCREEN INTERVAL
DEPTH:
UNK
PUMPING WATER LEVEL (feet): UNK
PURGE PUMP TYPE: Existing Pump
WELL VOLUME PURGE: 1 WELL VOLUME = (TOTAL W ELL DEPTH - STATIC DEPTH TO WATER) X WELL CAPACITY
(only fill out if applicable)
. = ( 2 -2. (p
feet -
UNK
feet) X
gallons/foot =
qallons
EQUIPMENT VOLUME PURGE: 1 EQUIPMENT VOL. = PUMP VOLUME + (TUBING CAPACITY X TUBING LENGTH) + FLOW CELL VOLUME
(only fill out if applicable)
= gallons + (
gallons/foot X
feet) +
gallons =
gallons
PUMP DEPTH IN W E LL (feet): UNK
TIME (CST)
VOLUME PURGED (gallons)
CUMUL. VOLUME PURGED (gallons)
llo q
13 I3/
FINAL PUM P DEPTH IN W ELL (feet): UNK
PURGING
.
INITIATED AT: ! * S 3
PURGE RATE
(9Pm)
ORP (mV)
fe y
pH (standard
units)
TEMP. (C)
L .H 'i 2 c . o
L q z 2 o -/6
COND. ( S/cm)
Z&
Uf
Um z
2*3
PURGING ENDED AT: DISSOLVED OXYGEN
(mg/L)
2.-3 Cp
TOTAL VOLUME PURGED (gallons):
TURBIDITY (NTUs)
COLOR (describe)
ODOR (describe)
z Clear
None
Clear
None
/
Clear
None
WELL CAPACITY (Gallons Per Foot): 0.76" =0.02; 1" = 0.04; 1.25" = 0.06; 2" = 0.16; 3" = 0.37; 4" =0.65; 5" =1.02; 6" = 1.47; 12" =5.88 TUBING INSIDE DIA. CAPACITY (Gal./Ft.): 1/8" =0.0006; 3/16" = 0.0014; 1/4" = 0.0026; 5/16" =0.004; 3/8" = 0.006; 1/2" = 0.010; 5/8" = 0.016
PURGING EQUIPMENT CODES: B = Bailer; BP = Bladder Pump;
ESP = Electric Submersible Pump;
PP = Peristaltic Pump;
O =Other (Specify)
SAMPLING DATA
SAM PLED BY (PRINT) /AFFILIATION: David L. Anderson/CDM
SAMPLER(S) SIGNATURE(S):
SAMPLING
i,
INITIATED AT: / J 1
SAMPLING ENDED AT:
PUMP DEPTH IN W E LL (feet): UNK
FIELD DECONTAMINATION;
PUMP: No
TUBING MATERIAL CODE: NA
TUBING: NA
FIELD-FILTERED: No Filtration Equipment Type:
DUPLICATE:
NA
FILTER SIZE: No
NA
urn
SAMPLE CONTAINER SPECIFICATION
SAMPLE IDCODE
NA
# CONTAINERS
2
MATERIAL CODE
PE
VOLUME 1liter
SAMPLE PRESERVATION
PRESERVATIVE USED
None
TOTAL VOL ADDED IN FIELD (ml)
None
FINAL pH NA
INTENDED ANALYSIS AND/OR
METHOD
PFOA, PFOS, &
SAMPLING EQUIPMENT
CODE
O-Grab
SAMPLE PUMP FLOW RATE
(mL per minute)
<100 mL
Fluorinated Cmps
by HPLC/MS.
REMARKS: NA - Not Applicable.
UNK - Unknown.
Was the well pumping (active) prior to sampling -(^Yes) or No.
MS/MSD sample collected - Yes or (fig ) Collection Time:
Well has fluoride treatment - Yes or^p)
Photograph No. / Id
CAi">'v\f MATERIAL CODES:
H 3 1. A G =Amber Glass; C G =Clear Glass;
PE = Polyethylene;
PP =Polypropylene; S = Silicone; T = Teflon; O =Other (Specify)
SAMPLING EQUIPMENT CODES:
A P P = After Peristaltic Pump;
B = Bailer; B P = Bladder Pump; E SP = Electric Submersible Pump;
RFPP = Reverse Flow Peristaltic Pump; SM = Straw Method (Tubing Gravity Drain); 0 = Other (Grab)
ivOTES: 1. The above do not constitute all of the Information required by Chapter 62-160, F.A.C.
2 . S t a b i l i z a t i o n C r i t e r i a f o r r a n g e o f v a r i a t i o n o f l a s t t h r e e c o n s e c u t i v e r e a d i n g s ( s e e F S 2 2 1 2 . section 3 )
pH: + 0.2 units Temperature: + 0.2 C Specific Conductance: +5% Dissolved Oxygen: all readings < 20% saturation (see Table FS 2200-2); optionally, 0.2 mg/L or + 10% (whichever is greater) Turbidity: all readings < 20 NTU; optionally + 5 NTU or + 10% (whichever Is greater)
Revision Date: February 12, 2009
I W WWW
GROUNDWATER SAMPLING LOG
p. 82
I SITE I NAME: ECUA Water Distribution System (Countv-wide)
SITE LOCATION: Escambia County, Florida
'ELL NO: f j $ c & r
SAMPLE ID:
DATE: February
2010
PURGING DATA
WELL CASING
/ TUBING
DIAMETER (Inches): ^ DIAMETER (Inches): NA
WELL SCREEN INTERVAL
DEPTH:
UNK
PUMPING WATER LEVEL (feet): UNK
PURGE PUMP TYPE: Existing Pump
WELL VOLUME PURGE: 1 WELL VOLUME = (TOTAL W ELL DEPTH - STATIC DEPTH TO WATER) X WELL CAPACITY
(only fill out if applicable)
= ( 2 -^ 7
feet-
UNK
feet) X
gallons/foot =
gallons
EQUIPMENT VOLUME PURGE: 1 EQUIPMENT VOL = PUM P VOLUME + (TUBING CAPACITY X TUBING LENGTH) + FLOW CELL VOLUME
(only fill out if applicable)
= gallons + (
gallons/foot X
feet) +
gallons =
gallons
PUMP DEPTH IN W E LL (feet): UNK
TIME (CST)
VOLUME PURGED (gallons)
CUMUL. VOLUME PURGED
(gallons)
I3 2 Z
1 3 2 .5
FINAL PUMP DEPTH IN WELL (feet): UNK
PURGING
1 7 /Q
INITIATED AT: I J ' /
PURGE RATE
(gpm)
ORP (mV)
3T6 -- -
pH (standard
units)
C>Vb
> .3?
TEMP. (C)
ZZ-tle 2Z.iei 22 4 b
COND. (pS/cm)
8<r & (> V
PURGING ENDED AT:
DISSOLVED OXYGEN (mg/L)
0 .? 4
0.< r/ 0 .7 3
TOTAL VOLUME PURGED (gallons):
TURBIDITY (NTUs)
COLOR (describe)
ODOR (describe)
Clear
None
Clear
None
C le a r
None
vELL CAPACITY (Gallons Per Foot): 0.75" = 0.02; 1" = 0.04; 1.25" = 0.06; 2" = 0.16; 3" = 0.37; 4" = 0.65; 5" = 1.02; 6" = 1.47; 12" = 5.88 TUBING INSIDE DIA. CAPACITY (GaUFt.): 1/8" = 0.0006; 3/16" = 0.0014; 1/4" = 0.0026; 5/16" = 0.004; 3/8" = 0.006; 1/2" = 0.010; 5/8" = 0.016
PURGING EQUIPMENT CODES: B = Bailer; BP = Bladder Pump;
ESP = Electric Submersible Pump;
PP = Peristaltic Pump;
O = Other (Specify)
SAMPLING DATA
SAM PLED BY (PRINT) / AFFILIATION: David L. Anderson/CDM
S)MVIPLER(S) Slj^NATURE(S):
SAMPLING 17 7 / INITIATED AT: /->->/
SAMPLING ENDED AT:
PUMP DEPTH IN W ELL (feet): UNK
FIELD DECONTAMINATION:
PUMP: No
TUBING MATERIAL CODE: NA
TUBING: NA
FIELD-FILTERED: No Filtration Equipment Type:
DUPLICATE:
NA
FILTER SIZE: No
NA
urn
SAMPLE CONTAINER SPECIFICATION
SAMPLE ID CODE
NA
# CONTAINERS
2
MATERIAL CODE
PE
VOLUME 1 liter
SAMPLE PRESERVATION
PRESERVATIVE USED
None
TOTAL VOL ADDED IN FIELD (mL)
None
FINAL pH NA
INTENDED ANALYSIS AND/OR
METHOD
PFOA, PFOS, &
SAMPLING EQUIPMENT
CODE
O-Grab
SAMPLE PUMP FLOW RATE
(mL per minute)
<100 mL
Fluorinated Cmps
by HPLC/MS.
REMARKS: NA - Not Applicable.
UNK - Unknown.
Was the well pumping (active) prior to sampling -^Y^ or No.
MS/MSD sample collected - Yes or^N^ Collection Time:
Well has fluoride treatment -^Ye^or No.
Photograph No. / -f
c A r.'n y
/ V V '.
MATERIAL CODES:
A G = Amber Glass; CG = Clear Glass; P E = Polyethylene; PP = Polypropylene; S = Silicone; T= Teflon; O = Other (Specify)
\MPLING EQUIPMENT CODES: APP = After Peristaltic Pump;
B = Bailer; B P = Bladder Pump; E S P = Electric Submersible Pump;
RFPP = Reverse Flow Peristaltic Pump; SM = Straw Method (Tubing Gravity Drain); O = Other (Grab)
NOTES: 1. The above do not constitute all of the information required by Chapter 62-160, F.A.C. 2. S t a b il iz a t io n C r it e r ia f o r r a n g e o f v a r ia t io n o f l a s t t h r e e c o n s e c u t i v e r e a d i n g s (s e e F S 2 2 1 2 , s e c t i o n 3) pH: + 0.2 units Temperature: +0.2 C Specific Conductance: +5% Dissolved Oxygen: all readings <20% saturation (see Table FS 2200-2); optionally, 0.2 mg/L or + 10% (whichever is greater) Turbidity: all readings <20 NTU; optionally + 5 NTU or + 10% (whichever Is greater)
Revision Date: February 12, 2009
I V/IIII I U J W V U - . T
GROUNDWATER SAMPLING LOG
I SITE I NAME: ECUA Water Distribution System (County-wide)
SITE LOCATION: Escambia County, Florida
/ELL NO: f ^
SAMPLE ID: "T x e
PURGING DATA
DATE: February 2 . .2010
WELL CASING
- / TUBING
WELL SCREEN INTERVAL
PUMPING WATER
PURGE PUMP TYPE:
DIAMETER (inches): ^ ^ DIAMETER (Inches): NA
DEPTH:
UNK
LEVEL (feet): UNK
Existing Pump
W ELL VOLUME PURGE: 1 W ELL VOLUME = (TOTAL WELL DEPTH - STATIC DEPTH TO WATER) X WELL CAPACITY
(only fill out it applicable)
=( 2 V i
feet-
UNK
feet) X
gallons/foot =
gallons EQUIPMENT VO LU M E PURGE: 1 EQUIPMENT VOL. = PUM P VOLUME + (TUBING CAPACITY X TUBING LENGTH) + FLOW CELL VOLUME
(only fill out if applicable)
= gallons + (
gallons/foot X
feet) +
gallons -
gallons
PUM P DEPTH IN W ELL (feet): UNK
TIME (CST)
VOLUME PURGED (gallons)
CUMUL. VOLUME PURGED (gallons)
1233
/3 H
/3 7 T
FINAL PUMP DEPTH IN W ELL (feet): UNK
PURGE RATE (gpm)
ORP (mV)
pH (standard
units)
HL SIS
PURGING
1* 7 / 0
INITIATED AT: ' i / (
TEMP. (C)
COND. (pS/crn)
n .3 *t n .n n -H i
/ fti is t
PURGING ENDED AT: DISSOLVED OXYGEN
(mg/L)
*./? .1 3
TOTAL VOLUME PURGED (gallons):
TURBIDITY (NTUs)
COLOR (describe)
ODOR (describe)
Clear Clear Clear
None None None
.(/ELL CA PA CITY (Gallons Per Foot): 0.75" = 0.02; 1" = 0.04; 1.25" = 0.06; 2" = 0.16; 3" = 0.37; 4" =0.65; 5" =1.02; 6" = 1.47; 12" = 5.88 TUBING INSIDE DIA. CAPACITY (GalTFt.): 1/8" = 0.0006; 3/16" = 0.0014; 1/4" = 0.0026; S/16" =0.004; 3/8" = 0.006; 1/2" = 0,010; S/8" = 0.016
PURGING EQUIPMENT CODES: B = Bailer; B P = Bladder Pump;
E S P = Electric Submersible Pump;
PP = Peristaltic Pump;
O = Other (Specify)
SAMPLING DATA
SAM PLED BY (PRINT) / AFFILIATION: David L. Anderson/CDM
SA^^ER(S|^IGNATURE(S):
SAMPLING INITIATED AT: / i V 2'
SAMPLING ENDED AT:
PU M P DEPTH IN W ELL (feet): UNK
FIELD DECONTAMINATION:
PUMP: No
TUBING MATERIAL CODE: NA
TUBING: NA
FIELD-FILTERED: No Filtration Equipment Type:
DUPLICATE:
NA
FILTER SIZE: No
NA
urn
SAMPLE CONTAINER SPECIFICATION
SAMPLE ID CODE
NA
# CONTAINERS
2
MATERIAL CODE
PE
VOLUME 1liter
SAMPLE PRESERVATION
PRESERVATIVE USED
None
TOTAL VOL ADDED IN FIELD (mL)
None
FINAL pH NA
INTENDED ANALYSIS AND/OR
METHOD
PFOA, PFOS, &
SAMPLING EQUIPMENT
CODE
O-Grab
SAMPLE PUMP FLOW RATE
(mL per minute)
<100 mL
Fluorinated Cmps
by HPLC/MS.
REMARKS: NA - Not Applicable.
UNK - Unknown.
Was the well pumping (active) prior to sampling
or No.
MS/MSD sample collected - Yes or(''N5) Collection Time:
Well has fluoride treatm ent^ Y^ or No.
Photograph No. / q
c.ft rr n . y
/ V V *.
MATERIAL CODES:
A G =Amber Glass; C G = Clear Glass; P E = Polyethylene; PP = Polypropylene; S = Silicone; T =Teflon; O = Other (Specify)
AMPLING EQUIPMENT CODES: A P P = After Peristaltic Pump;
B = Bailer; B P = Bladder Pump; ESP = Electric Submersible Pump;
RFPP = Reverse Flow Peristaltic Pump; SM = Straw Method (Tubing Gravity Drain); O = Other (Grab)
NOTES: 1. The above do not constitute all of the information required by Chapter 62-160, F.A.C.
2. S T A B IL IZ A T IO N C R I T E R I A F O R R A N G E O F V A R IA T IO N O F L A S T T H R E E C O N S E C U T I V E R E A D I N G S ( S E E F S 2212. S E C T IO N 3)
pH: + 0.2 units Temperature: + 0.2 C Specific Conductance: +5% Dissolved Oxygen: all readings < 20% saturation (see Table FS 2200-2); optionally, + 0.2 mg/L or + 10% (whichever is greater) Turbidity: all readings < 20 NTU; optionally + 5 NTU or + 10% (whichever is greater)
Revision Date: February 12, 2009
r o r m r u uu u- h
GROUNDWATER SAMPLING LOG
p. 84
I SITE
1NAME: ECUA Water Distribution System (Countv-wide)
SITE LOCATION: Escambia County. Florida
/ELL NO:
b u s .l|
SAM PLE ID:
DATE: February 2. ,2010
PURGING DATA
WELL CASING
. TUBING
WELL SCREEN INTERVAL
PUMPING WATER
PURGE PUMP TYPE:
DIAMETER (inches):
DIAMETER (inches): NA | DEPTH:
UNK
LEVEL (feet): UNK
Existing Pump
WELL VOLUME PURGE: 1 WELL VOLUME = (TOTAL W ELL DEPTH - STATIC DEPTH TO WATER) X W ELL CAPACITY
(only fill out if applicable)
gallons
= ( J2. / 5
feet -
UNK
feet) X
gallons/foot =
EQUIPMENT VOLUME PURGE: 1 EQUIPMENT VOL. = PUMP VOLUME + (TUBING CAPACITY X TUBING LENGTH) + FLOW CELL VOLUME
(only fill out if applicable)
= gallons+ (
gallons/foot X
feet)+
gallons =
gallons
PUM P DEPTH IN W E LL (feet): UNK
TIME (CST)
VOLUME PURGED (gallons)
CUMUL. VOLUME PURGED (gallons)
/3 S 3
!3*<
n s^
FINAL PUMP DEPTH IN W ELL (feet): UNK
PURGING
-
INITIATED AT: I J 5 0
PURGE RATE (gpm)
ORP (mV)
rn --
-
pH (standard
units)
TEMP. (C)
U3 4 -0 2 . 4 .c3
22-
21. ?S
COND. (pS/cm)
m J/o
//o
PURGING ENDED AT:
DISSOLVED OXYGEN (mg/L)
Z . l3 r
Z .1 3
z -3 3
TOTAL VOLUME PURGED (gallons):
TURBIDITY (NTUs)
COLOR (describe)
ODOR (describe)
O
Clear
None
O
Clear
None
Clear
None
WELL CAPACITY (Gallons Per Foot): 0.75" = 0.02; 1" = 0.04; 1.25" = 0.06; 2" = 0.16; 3" = 0.37; 4" = 0.65; 5" =1.02; 6" = 1.47; 12" = 5.88 TUBING INSIDE DIA. CAPACITY (Qal.ZFU: 1/8" = 0.0006; 3/16" = 0.0014; 1/4" = 0.0026; 5/16" = 0.004; 3/8" = 0.006; 1/2" = 0.010; 5/8" = 0.016
PURGING EQUIPMENT CODES: B = Bailer;
SAM PLED BY (PRINT) / AFFILIATION: David L. Anderson/CDM
BP = Bladder Pump;
ESP = Electric Submersible Pump;
PP = Peristaltic Pump;
SAMPLING DATA
SAMPLER(S)SIGNATURE(S):
SAMPLING
.
INITIATED AT: / V 0 V
O = Other (Specify)
SAMPLING ENDED AT:
PUM P DEPTH IN W E LL (feet): UNK
TUBING MATERIAL CODE: NA
FIELD-FILTERED: No
FILTER SIZE: NA
Filtration Eguipment Type: NA
urn
FIELD DECONTAMINATION: PUMP: No
TUBING: NA
DUPLICATE:
No
SAMPLE CONTAINER SPECIFICATION
SAMPLE ID CODE
NA
# CONTAINERS
2
MATERIAL CODE
PE
VOLUME 1liter
SAMPLE PRESERVATION
PRESERVATIVE USED
None
TOTAL VOL ADDED IN FIELD (mL)
None
FINAL pH NA
INTENDED ANALYSIS AND/OR
METHOD
PFOA, PFOS, &
Fluorinated Cmps
SAMPLING EQUIPMENT
CODE
O-Grab
SAMPLE PUMP FLOW RATE
(mL per minute)
<100 mL
by HPLC/MS.
REMARKS: NA - Not Applicable.
UNK Unknown.
Was the well pumping (active) prior to sampling
or No.
MS/MSD sample collected - Yes or ( N ^ Collection Time:
Well has fluoride treatment -^^Sjor No.
Photograph No. / ^
CR-T.-wy MATERIAL CODES:
//>' A G =Amber Glass; CG = Clear Glass;
P E = Polyethylene;
PP = Polypropylene; S = Silicone; T =Teflon; O = Other (Specify)
AMPLING EQUIPM ENT CODES: A PP = After Peristaltic Pump;
B = Bailer; B P = Bladder Pump; ESP = Electric Submersible Pump;
RFPP = Reverse Flow Peristaltic Pump; SM = Straw Method (Tubing Gravity Drain); O = Other (Grab)
NOTES: 1. The above do not constitute all of the information required by Chapter 62-160, F.A.C. 2. S t a b il iz a t io n C r it e r ia f o r r a n g e o f v a r ia t io n o f l a s t t h r e e c o n s e c u t iv e r e a d in g s (s e e FS 2212, s e c t io n 3)
pH: + 0.2 units Temperature: + 0.2 C Specific Conductance: +5% Dissolved Oxygen: all readings < 20% saturation (see Table FS 2200-2); optionally, 0.2 mg/L or + 10% (whichever is greater) Turbidity: all readings <20 NTU; optionally +5 N T U or + 10% (whichever is greater)
Revision Date; February 12, 2009
ro riii r u uuu-x*
GROUNDWATER SAMPLING LOG
p 35
I SITE I NAME: ECUA Water Distribution System (County-wide)
SITE LOCATION: Escambia County, Florida
'ELL NO: / P o . 4> u , * ! I M v a V
SAMPLE ID:
DATE: February '2__ , 2010
PURGING DATA
WELL CASiNG
, TUBING
WELL SCREEN INTERVAL
PUMPING WATER
PURGE PUMP TYPE:
DIAMETER (inches): - 2 U> DIAMETER (inches): NA
DEPTH:
UNK
LEVEL (feet): UNK
Existing Pump
W ELL VOLUME PURGE: 1 W ELL VOLUME = (TOTAL WELL DEPTH - STATIC DEPTH TO WATER) X WELL CAPACITY
(only fill out if applicable)
= ( J2, /
feet -
UNK
feet) X
gallons/foot =
qallons EQUIPMENT VO LU M E PURGE: 1 EQUIPMENT V O L =PUM P VOLUME +(TUBING CAPACITY X TUBING LENGTH) +FLOW CELL VOLUME
(only fill out if applicable)
= gallons +(
gallons/foot X
feet) +
gallons =
gallons
PUM P DEPTH IN W ELL (feet): UNK
TIME (CST)
VOLUME PURGED (gallons)
CUMUL. VOLUME PURGED (aallons)
/yctf-
N/b m3
FINAL PUMP DEPTH IN W ELL (feet): UNK
PURGE RATE (gpm)
ORP (mV)
pH (standard
units)
ro
6. S' ? kSl
PURGING
.
INITIATED AT: 3 i t
TEMP. (C)
n i 2.
mi
COND. (pS/cm)
ns
8 1
PURGING ENDED AT; DISSOLVED OXYGEN
(mg/L)
(p
e>.%S
TOTAL VOLUME PU RGED (gallons);
TURBIDITY (NTUs)
COLOR (describe)
ODOR (describe)
O
Clear
None
Clear
None
/
0
Clear
None
W ELL CAPACITY (Gallons Per Foot): 0.75" = 0.02; 1" =0.04; 1.25" = 0.06; 2'' = 0.16; 3" = 0.37; 4" = 0.65; 5" =1.02; 6" = 1.47; 12" = 5.88 TUBING INSIDE DIA. CAPACITY (Gal./Ft.): 1/8" =0.0006; 3/16" =0.0014; 1/4" =0.0026; 5/16" =0.004; 3/8" =0.006; 1/2" = 0.010; S/8" = 0.016
PURGING EQUIPMENT CODES: B =Bailer; B P =Bladder Pump;
E S P =Electric Submersible Pump;
PP =Peristaltic Pump;
O =Other (Specify)
SAMPLING DATA
SAM PLED BY (PRINT) / AFFILIATION: David L. Anderson/CDM
SAMPLER(S)SIGNATURE(S):
SAMPLING INITIATED AT: I H ! T
SAMPLING ENDED AT:
PUM P DEPTH IN W ELL (feet): UNK FIELD DECONTAMINATION: PUMP: No
TUBING MATERIAL CODE; NA
TUBING: NA
FIELD-FILTERED; No Filtration Equipment Type:
DUPLICATE:
NA
FILTER SIZE: No
NA
urn
SAMPLE CONTAINER SPECIFICATION
SAMPLE ID CODE
NA
ft CONTAINERS
2
MATERIAL CODE
PE
VOLUME 1liter
SAMPLE PRESERVATION
PRESERVATIVE USED
None
TOTAL VOL ADDED IN FIELD (mL)
None
FINAL pH NA
INTENDED ANALYSIS AND/OR
METHOD
PFOA, PFOS, &
SAMPLING EQUIPMENT
CODE
O-Grab
SAMPLE PUMP FLOW RATE
(mLper minute)
<100 mL
Fluorinated Cmps
by HPLC/MS.
REMARKS: NA - Not Applicable.
UNK - Unknown.
W as the well pumping (active) prior to sampling -^Yebj or No.
MS/MSD sample collected - Yes or (N o) Collection Time:
Well has fluoride treatment - ^ e s } x No.
Photograph No. J 2 . 0
Cftrr< \5
to'.
MATERIAL CODES:
A G = Amber Glass; C G = Clear Glass;
PE = Polyethylene;
PP = Polypropylene; S = Silicone; T =Teflon; O = Other (Specify)
'A M P LIN G EQUIPMENT CODES: A P P = After Peristaltic Pump,
B = Bailer; B P = Bladder Pump; E S P = Electric Submersible Pump;
R FPP = Reverse Flow Peristaltic Pump; SM = Straw Method (Tubing Gravity Drain); O = Other (Grab)
N O TES: 1. The above do not constitute all of the Information required by Chapter 62-160, F.A.C. 2. S t a b il iz a t io n C r it e r ia f o r r a n g e o f v a r ia t io n o f l a s t t h r e e c o n s e c u t i v e r e a d i n g s (s e e F S 2 2 1 2 . s e c t io n 3)
pH: + 0 .2 units Temperature: + 0 .2 C Specific Conductance: +5% Dissolved Oxygen: all readings <2 0 % saturation (see Table FS 2 2 0 0 -2 ); optionally, + 0 .2 mg/L or +10 % (whichever is greater) Turbidity: all readings <2 0 NTU; optionally + 5 NTU or + 10% (whichever is greater)
Revision Date: February 12, 2009
VI I
GROUNDWATER SAMPLING LOG
p. 86
SITE NAME: ECUA Water Distribution Svstem (Countv-wlde)
SITE LOCATION: Escambia County, Florida
VELLNO:
Uj Q|/ /V flrv r
SAM PLE ID: R p m
DATE: February 3 ,2010
PURGING DATA
WELL CASING
I TUBING
DIAMETER (Inches): 2 - (p J DIAMETER (Inches): NA
W ELL SCREEN INTERVAL
DEPTH:
UNK
PUMPING WATER LEVEL (feet): UNK
I PURGE PUMP TYPE: | Existing Pump
WELL VOLUME PURGE: 1 WELL VOLUME = (TOTAL W ELL DEPTH - STATIC DEPTH TO WATER) X WELL CAPACITY
(only fill out if applicable)
gallons
= ( 2 ( 0
feet-
UNK
feet) X
gallons/foot =
EQUIPMENT VOLUME PURGE: 1 EQUIPMENT V O L = PUM P VOLUM E + (TUBING CAPACITY X TUBING LENGTH) + FLOW C E LL VOLUME
(only fill out if applicable)
= gallons + (
gallons/foot X
feet) +
gallons =
gallons
PUM P DEPTH IN W E LL (feet): UNK
TIME (CST)
VOLUME PURGED (gallons)
CUMUL. VOLUME PURGED (gallons)
b lS l
s is
I FINAL PUMP | DEPTH IN WELL (feet): UNK
PURGE RATE (gpm)
ORP (mV)
4^ 2.
PH (standard
units)
4-?-/
0
W
4 -b 8 (o.>1
PURGING INITIATED AT:
-
TEMP. (C)
COND. (pS/cm)
2 1 . 2 <0
2 2 .2 .1
2 2 .2 -1
84 62 &3
PURGING ENDED AT:
DISSOLVED OXYGEN (mg/L)
I TOTAL VOLUME j PURGED (gallons):
TURBIDITY COLOR
(NTUs)
(describe)
ODOR (describe)
O
Clear
None
C le a r
None
0
Clear
None
YELL CAPACITY (Gallons Per Foot): 0.75" = 0.02; 1" = 0.04; 1.25" = 0.06; 2" = 0.16; 3" = 0.37; 4" =0.65; 5" = 1.02; 6" =1.47; 12" = 5.88 TUBING INSIDE DIA. CAPACITY (Gal./Ft.): 1/8" = 0.0006; 3/16" = 0.0014; 1/4" = 0.0026; 5/16" =0.004; 3/8" = 0.006; 1/2" = 0.010; 5/8" = 0.016
PURGING EQUIPMENT CODES: B= Bailer; BP = Bladder Pump;
ESP = Electric Submersible Pump;
PP = Peristaltic Pump;
O = Other (Specify)
SAM PLED B Y (PRINT) / AFFILIATION: David L. Anderson/CDM
SAMPLING DATA
S ^ P L^ (S|^ G N A T U R E(S):
SAMPLING
_
INITIATED AT: C g C Z
SAMPLING ENDED AT:
PU M P DEPTH IN W E LL (feet): UNK
FIELD DECONTAMINATION:
PUMP: No
TUBING MATERIAL CODE: NA
TUBING: NA
FIELD-FILTERED: No Filtration Equipment Type:
DUPLICATE:
NA
FILTER SIZE: No
NA
urn
SAMPLE CONTAINER SPECIFICATION
SAMPLE ID CODE
NA
# CONTAINERS
2
MATERIAL CODE
PE
VOLUME
1liter
SAMPLE PRESERVATION
PRESERVATIVE USED
None
TOTAL VOL ADDED IN FIELD (mL)
None
FINAL pH NA
INTENDED ANALYSIS AND/OR
METHOD
PFOA, PFOS, &
SAMPLING EQUIPMENT
CODE
O-Grab
SAMPLE PUMP FLOW RATE
(mL per minute)
<100 mL
Fluorlnated Cmps
by HPLC/MS.
REMARKS: NA --Not Applicable.
UNK - Unknown.
Was the well pumping (active) prior to sampling ^YeiP^Or No.
MS/MSD sample collected - Yes or^Ng) Collection Time:
Well has fluoride treatment fYos)tii No.
Photograph No. f ( S a 4-c Ii j ' )
C.P1JV A 5
MATERIAL CODES:
IS ? A G =Amber Glass; CG = Clear Glass;
PE = Polyethylene;
PP = Polypropylene; S = Silicone; T = Teflon; O = Other (Specify)
'A M P LIN G EQUIPM ENT CODES: A P P = After Peristaltic Pump;
B = Bailer; BP = Bladder Pump; E S P = Electric Submersible Pump;
RFPP = Reverse Flow Peristaltic Pump; SM = Straw Method (Tubing Gravity Drain); O = Other (Grab)
N O TES: 1. The above do not constitute all of the Information required by Chapter 62-160, F.A.C. 2. S t a b il iz a t io n C r it e r ia f o r r a n g e o f v a r ia t io n o f l a s t t h r e e c o n s e c u t iv e r e a d in g s (s e e F S 2212, s e c t io n 3)
pH: + 0.2 units Temperature: + 0.2 C Specific Conductance: + 5% Dissolved Oxygen: all readings < 20% saturation (see T ab le F S 2200-2); optionally, + 0.2 m g/L or + 10%-(w hlchever is greater) Turbidity: all readings < 2 0 NTU; optionally + 5 N T U or + 10% (whichever is greater)
Revision Date: February 12, 2009
W i m I w <fw w w f c '
GROUNDWATER SAMPLING LOG
I SITE I NAME: ECUA Water Distribution System (County-wide)
SITE LOCATION: Escambia County, Florida
fELLNQ; / . / ^ / ^ u ^ | l
SAMPLE ID: -
DATE: February ^
, 2010
PURGING DATA
W ELL CASING
TUBING
WELL SCREEN INTERVAL
PUMPING WATER
PURGE PUMP TYPE:
DIAMETER (inches): b
DIAMETER (inches): NA
DEPTH:
UNK
LEVEL (feet): UNK
Existing Pump
W ELL VOLUME PURGE: 1 W ELL VOLUME = (TOTAL WELL DEPTH - STATIC DEPTH TO WATER) X WELL CAPACITY
(only fill out if applicable)
=( ^
1
feet -
UNK
- feet) X
gallons/foot =
gallons________________ ____________________________________________________________________________________________ ______ ___________________
EQUIPMENT VOLUM E PURGE: 1 EQUIPMENT VOL. = PUMP VOLUME + (TUBING CAPACITY X TUBING LENGTH) + FLOW CELL VOLUME
(only fill out if applicable)
= gallons + ( _______ gallons/foot X_______________ feet) +_____________ gallons =_______gallons
PUM P DEPTH IN W ELL (feet): UNK
TIME (CST)
VOLUME PURGED (gallons)
CUMUL. VOLUME PURGED (gallons)
6 8 oV
CbSc l
63/0
FINAL PUMP DEPTH IN W ELL (feet): UNK
PURGE RATE (gpm)
ORP (mV)
37>
pH (standard
units)
?-ol
tj/k t/GT.
X .c o
2-.
PURGING
PURGING
INITIATED AT: 0 + 7 . 5 ENDED AT:
TEMP. <C)
COND. (pS/cm)
DISSOLVED OXYGEN (mg/L)
mi mi
m/&o
m
?.c4 (a.
TOTAL VOLUME PURGED (gallons):
TURBIDITY (NTUs)
COLOR (describe)
ODOR (describe)
Clear
None
2.
Clear
None
)
Clear
None
./E L L CA PA CITY (Gallons Per Foot): 0.75" = 0.02; 1" = 0.04; 1.25" = 0.06; 2" = 0.16; 3" = 0.37; 4"=0.65; 5" = 1.02; 6" = 1.47; 12" = 5.88 TUBING INSIDE DfA. CA PA CITY (Gal./Ft.): 1/8" = 0.0006; 3/16" = 0.0014; 1/4" = 0.0026; 5/16" = 0.004; 3/8'= 0.006; 1/2* = 0.010; 5/8" = 0.016
PURGING EQUIPMENT CODES: B = Bailer;
SA M PLED B Y (PRINT) /AFFILIATION:
David L. Anderson/CDM
B P = Bladder Pump;
E S P = Electric Submersible Pump;
PP = Peristaltic Pump;
SAMPLING DATA
SAMPLER(S) SIGNATURE(S):
SAMPLING
INITIATED AT: 813
O = Other (Specify)
SAMPLING ENDED AT:
PU M P DEPTH IN W ELL (feet): UNK
FIELD DECONTAMINATION:
PUMP: No
TUBING MATERIAL CODE: NA
TUBING: NA
FIELD-FILTERED: No Filtration Equipment Type:
DUPLICATE:
NA
FILTER SIZE: No
NA
urn
SAMPLE CONTAINER SPECIFICATION
SAMPLE ID CODE
#
CONTAINERS
MATERIAL CODE
VOLUME
NA 2 PE I liter
SAMPLE PRESERVATION
PRESERVATIVE USED
None
TOTAL VOL ADDED IN FIELD (mL)
None
FINAL pH NA
INTENDED ANALYSIS AND/OR
METHOD
PFOA, PFOS, &
SAMPLING EQUIPMENT
CODE
O-Grab
SAMPLE PUMP FLOW RATE
(mL per minute)
<100 mL
Fluorinated Cmps
by HPLC/MS.
REMARKS: NA - Not Applicable.
UNK - Unknown.
W as the well pumping (active) prior to sampling - Y e ^ o r No.
MS/MSD sample collected - Yes or (N o ) Collection Time:
Well has fluoride treatment ^ 3 ^ r No.
/5~-f
MATERIAL CODES:
A G =Amber Glass;
CG =Clear Glass;
Photograph No.
I^
Jl
P E =Polyethylene;
3 C c /| c (-a3 /A 4 P P =Polypropylene; S =Silicone;
T =Teflon;
^7" >4S' 6 . O =Other (Specify)
' \M PLIN G EQUIPMENT CODES: A P P = After Peristaltic Pump;
B = Bailer; B P = Bladder Pump; ESP = Electric Submersible Pump;
RFPP = Reverse Flow Peristaltic Pump; SM = Straw Method (Tubing Gravity Drain); O = Other (Grab)
N O TE S: 1. The above d o not constitute all of the information required by Chapter 62-160, F.A.C. 2. S t a b iliza t io n C r it e r ia f o r r a n g e o f v a r ia t io n o f l a s t t h r e e c o n s e c u t i v e r e a d i n g s (s e e F S 2212. s e c t io n 3)
pH: +0.2 units Temperature: + 0.2 C Specific Conductance: +5% Dissolved Oxygen: all readings <20% saturation (see Table FS 2200-2); optionally, + 0.2 mg/L or + 10% (whichever is greater) Turbidity: all readings < 20 NTU; optionally +5 NTU or + 10% (whichever is greater)
Revision Date: February 12, 2009
GROUNDWATER SAMPLING LOG
SITE NAME: ECUA Water Distribution System (Countv-wide)
V E L L N O :^ ^
SAMPLE ID:
I SITE I LOCATION: Escambia County, Florida
DATE: February
,2010
PURGING DATA
WELL CASING
,,
TUBING
WELL SCREEN INTERVAL
PUMPING WATER
PURGE PUMP TYPE:
DIAMETER (inches); O
DIAMETER (inches); NA
DEPTH:
UNK
LEVEL (feet): UNK
Existing Pump
WELL VOLUME PURGE: 1 WELL VOLUME = (TOTAL W ELL DEPTH - STATIC DEPTH TO WATER) X W ELL CAPACITY (only fill out if applicable)
gallons
=( 2 40
feet-
UNK
EQUIPMENT VOLUME PURGE: 1 EQUIPMENT VOL. = PUM P VOLUME + (TUBING CAPACITY X
(only fill out if applicable)
= gallons + (
gallons/foot X
feet) X
gallons/foot =
TUBING LENGTH) + FLOW CELL VOLUME
feet) +
gallons =
gallons
PUM P DEPTH IN W E LL (feet): UNK
TIME (CST)
VOLUME PURGED (gallons)
CUMUL. VOLUME PURGED (gallons)
O B IS '
62 8
063/
FINAL PUMP DEPTH IN WELL (feet): UNK
PURGING
PURGING
INITIATED AT: O q 2 2 . ENDED AT:
PURGE RATE
(gpm)
ORP (mV)
3-2 2
pH (standard
units)
TEMP. (C)
2-2.- u /
COND. (pS/cm)
DISSOLVED OXYGEN (mg/L)
< j.ts
3 *1 322-
S -.3 8 S \3 &
22-00 22.0)
i/T -
7 . 0(0
TOTAL VOLUME PURGED (gallons):
TURBIDITY (NTUs)
COLOR (describe)
ODOR (describe)
6
Clear
None
Clear
None
O
Clear
None
.vELL CAPACITY (Gallons Per Foot): 0.75" = 0.02; 1" = 0.04; 1.25" = 0.06; 2" = 0.16; 3" = 0.37; 4" = 0.65; 5" = 1.02; 6" = 1.47; 12" = 5.88 TUBING INSIDE DIA. CAPACITY (Gal./Ft.): 1/8" = 0.0006; 3/16" = 0.0014; 1/4" =0.0026; 5/16" = 0.004; 3/8" = 0.006; 1/2" = 0.010; 5/8" = 0.016
PURGING EQUIPMENT CODES: B = Bailer; BP = Bladder Pump;
ESP = Electric Submersible Pump;
PP = Peristaltic Pump;
O = Other (Specify)
SAM PLED B Y (PRINT) / AFFILIATION: David L. Anderson/CDM
SAMPLING DATA
SfeMPLER(S) SIGNATURE(S):
3 X'i- -
33SAMPLING
INITIATED AT: 8
SAMPLING ENDED AT:
PUMP DEPTH IN W E LL (feet): UNK
TUBING MATERIAL CODE: NA
FIELD-FILTERED: No
FILTER SIZE: NA urn
Filtration Equipment Type: NA
FIELD DECONTAMINATION:
PUMP: No
TUBING: NA
DUPLICATE:
No
SAMPLE CONTAINER SPECIFICATION
SAMPLE IDCODE
NA
# CONTAINERS
2
MATERIAL CODE
PE
VOLUME 1liter
SAMPLE PRESERVATION
PRESERVATIVE USED
None
TOTAL VOL ADDED IN FIELD (mL)
None
FINAL pH NA
INTENDED ANALYSIS AND/OR
METHOD
PFOA, PFOS, &
Fluorlnated Cmps
SAMPLING EQUIPMENT
CODE
O-Grab
SAMPLE PUMP FLOW RATE
(mL per minute)
<100 mL
by HPLC/MS.
REMARKS: NA - Not Applicable.
UNK - Unknown.
Was the well pumping (active) prior to sampling Y e s ) or No. Well has fluoride treatment -^e^fcr No.
MS/MSD sample collected - Yes or
Photograph No. 3
0
Collection Time:
/V C .
MATERIAL CODES:
A G = Amber Glass; CG = Clear Glass; PE = Polyethylene; PP = Polypropylene; S = Silicone; T=Teflon; O = Other (Specify)
'4 M P L IN G EQUIPM ENT CODES: A P P = After Peristaltic Pump; B = Bailer; B P = Bladder Pump; E S P = Electric Submersible Pump; RFPP = Reverse Flow Peristaltic Pump; SM = Straw Method (Tubing Gravity Drain); 0 = Other (Grab)
NOTES: 1. The above d o not constitute all of the information required by Chapter 62-160, F.A.C. 2. S t a b il iz a t io n C r it e r ia f o r r a n g e o f v a r ia t io n o f l a s t t h r e e c o n s e c u t i v e r e a d i n g s (s e e FS 2212, s e c t io n 3)
pH: + 0.2 units Temperature: +0.2 C Specific Conductance: +5% Dissolved Oxygen: all readings <20% saturation (see Table FS 2200-2); optionally, + 0.2 mg/Lor + 10% (whichever is greater) Turbidity: all readings <20 NTU; optionally +5 NTU or + 10% (whichever is greater)
Revision Date: February 12,2009
ru m i rw owwvfcf
GROUNDWATER SAMPLING LOG
SITE NAME: ECU A Water Distribution System (County-wide)
SITE LOCATION: Escambia County, Florida
V E L L N O : X p A A , a T f ftCl
SAM PLE ID: " 7 7
PURGING DATA
DATE: February J
,2010
W ELL CASING
n 0 TUBING
WELL SCREEN INTERVAL
PUMPING WATER
PURGE PUMP TYPE:
DIAMETER (inches): ^
DIAMETER (inches): NA
DEPTH:
UNK
LEVEL (feet): UNK
Existing Pump
WELL VOLUME PURGE: 1 WELL VOLUME = (TOTAL W ELL DEPTH - STATIC DEPTH TO WATER) X WELL CAPACITY
(only fill out if applicable)
= ( O
feet-
UNK
feet) X
gallons/foot =
aailons EQUIPMENT VOLUME PURGE: 1 EQUIPMENT VOL. =PU M P VOLUME + (TUBING CAPACITY X TUBING LENGTH) + FLOW CELL VOLUME
(only fill out if applicable)
= gallons +(
gallons/foot X
feet) +
gallons =
gallons
PU M P DEPTH IN W ELL (feet): UNK
TIME (CST)
VOLUME PURGED (gallons)
CUMUL. VOLUME PURGED (gallons)
O I S
6638
b Hi
FINAL PUMP DEPTH IN W ELL (feet): UNK
PURGE RATE (gpm)
ORP (mV)
pH (standard
units)
2-/2
0*5
?-/o
PURGING
6 PURGING
INITIATED AT: 0 8-22. ENDED AT:
TEMP. (C)
COND. (pS/cm)
DISSOLVED OXYGEN (mg/L)
2\.y2 Z i - H 7-
HI m 13 o
r. tv r .t ? r. i t
TOTAL VOLUME PURGED (gallons):
TURBIDITY (NTUs)
COLOR (describe)
ODOR (describe)
/
Clear
None
0
Clear
None
/
Clear
None
/ELL CAPACITY (Gallons Per Foot): 0.75" =0.02; 1" =0.04; 1.25" =0.06; 2" =0.16; 3" =0.37; 4" =0.65; 5" = 1.02; 6" =1.47; 112" =5.88 TUBING INSIDE DIA. CAPACITY (Gal/Ft.): 1/8" =0.0006; 3/16" =0.0014; 1/4" = 0.0026; 5/16" =0.004; 3/8" =0.006; 1/2" =0.010; 5/8" =0.016
PURGING EQUIPMENT CODES: B =Bailer;
SA M PLED B Y (PRINT) /AFFILIATION: David L. Anderson/CDM
BP =Bladder Pump;
ESP = Electric Submersible Pump;
PP =Peristaltic Pump;
SAMPLING DATA
SAMPLER(SLGIGNATURE(S):
VSAMPLING
INITIATED AT: C S
0 =Other (Specify)
SAMPLING ENDED AT:
PU M P DEPTH IN W ELL (feet): UNK
TUBING MATERIAL CODE: NA
FIELD-FILTERED: No
FILTER SIZE: NA
Filtration Equipment Type: NA
urn
FIELD DECONTAMINATION:
PUMP: No
TUBING: NA
DUPLICATE:
No
SAM PLE CONTAINER SPECIFICATION
SAMPLE ID CODE
It
CONTAINERS
MATERIAL CODE
VOLUME
NA 2 PE 1liter
SAMPLE PRESERVATION
PRESERVATIVE USED
None
TOTAL VOL ADDED IN FIELD (mL)
None
FINAL pH NA
INTENDED ANALYSIS AND/OR
METHOD
PFOA, PFOS, &
SAMPLING EQUIPMENT
CODE
O-Grab
SAMPLE PUMP FLOW RATE
(mL per minute)
<100 mL
Fluorinated Cmps
by HPLC/MS.
REMARKS: NA - Not Applicable.
UNK - Unknown.
W as the well pumping (active) prior to sampling
or No.
MS/MSD sample collected - Yes or/'No) Collection Time:
Well has fluoride treatment -{Ygpor No.
Photograph No. J \- (.
c V> j
W0C A T.-fty Ai2.<h V\
MATERIAL CODES:
AG =Amber Glass; C G =Clear Glass;
P E =Polyethylene;
PP =Polypropylene; S = Silicone; T =Teflon; O =Other (Specify)
SA M PLIN G EQUIPMENT CODES: APP = After Peristaltic Pump;
B = Bailer; B P = Bladder Pump; E SP = Electric Submersible Pump;
RFPP = Reverse Flow Peristaltic Pump; SM = Straw Method (Tubing Gravity Drain); O = Other (Grab)
vUTES: 1. The above d o not constitute all of the information required by Chapter 62-160, F.A.C. 2. S tabilizatio n C riteria fo r r a n g e o f variatio n o f l a s t t h r e e c o n s e c u t iv e r e a d in g s fS E E F S 2 2 1 2 . section 3)
pH: + 0.2 units Temperature: + 0.2 C Specific Conductance: +5% Dissolved Oxygen: ail readings <20% saturation (see Table F S 2200-2); optionally, + 0.2 m g/L or + 10% (w hichever is greater) Turbidity: all readings < 20 N TU ; optionally + 5 N T U or + 10% (w hichever is greater)
Revision Date: February 12, 2009
I V4I111I WVWU-faT
GROUNDWATER SAMPLING LOG
p. 90
SITE NAME: ECUA Water Distribution System (Countv-wide)
SITE LOCATION: Escambia Countv, Florida
VELL NO: , P & rV / / r+ ^
SAM PLE ID:
DATE: February ^ ,2010
PURGING DATA
WELL CASING
~
^ ^DIAMETER (Inches):
TUBING DIAMETER (inches): NA
WELL SCREEN INTERVAL
DEPTH:
UNK
PUMPING WATER LEVEL (feet): UNK
PURGE PUMP TYPE: Existing Pump
=W ELL VOLUM E PURGE: 1 W ELL VOLUME (TOTAL W ELL DEPTH - STATIC DEPTH TO WATER) X WELL CAPACITY
(only fill out if applicable)
^
=( 2 (p t
feet-
UNK
feet) X
=gallons/foot
gallons
= + +EQUIPMENT VOLUME PURGE: 1 EQUIPMENT V O L PUM P VOLUME (TUBING CAPACITY X TUBING LENGTH) FLOW CELL VOLUME
(only fill out If applicable)
= gallons +(
gallons/foot X
+feet)
=gallons
gallons
PUMP DEPTH IN W ELL (feet): UNK
FINAL PUMP DEPTH IN W ELL (feet): UNK
PURGING AQvt INITIATED AT:
PURGING ENDED AT:
TOTAL VOLUME PURGED (gallons);
TIME (CST)
VOLUME PURGED (gallons)
CUMUL. VOLUME PURGED (gallons)
PURGE RATE (gpm)
ORP (mV)
VfS VSo
pH (standard
units)
TEMP. <C)
&./<r 2 / . ? ! L /? 2 /- f b
CONO. (gS/cm)
r2
DISSOLVED OXYGEN (mg/L)
1 -L 2
TURBIDITY (NTUs)
o o
COLOR (describe)
C le a r Clear
ODOR (describe)
None None
V 8 I L i V 2/. T l S'
? .L I
0 Clear
None
/ELL CAPACITY (Gallons Per Foot): 0.75" = 0.02; 1" = 0.04; 1.25" = 0.06; 2" = 0.16; 3" = 0.37; 4" =0.65; 5" = 1.02; 6" = 1.47; 12" = 5.88
= =TUBING INSIDE DIA. C APACIT Y (Gal./Ft.): 1/8" 0.0006; 3/16" =0.0014; 1/4" = 0.0026; 5/16" = 0.004; 3/8" = 0.006; 1/2" =0.010; 5/8" 0.016
= =PURGING EQUIPMENT CODES: B Bailer; B P Bladder Pump;
=E S P Electric Submersible Pump;
=PP Peristaltic Pump;
=O Other (Specify)
SAMPLING DATA
SAMPLED BY (PRINT) / AFFILIATION: David L. Anderson/CDM
SAMPLER(S) SIGNATURE(S):
SAMPLING INITIATED AT:
SAMPLING I3- ENDED AT:
PUM P DEPTH IN W ELL (feet): UNK
FIELD DECONTAMINATION:
PUMP: No
TUBING MATERIAL CODE: NA
TUBING: NA
FIELD-FILTERED: No Filtration Equipment Type:
DUPLICATE:
NA
FILTER SIZE: No
NA
urn
SAMPLE CONTAINER SPECIFICATION
SAMPLE IDCODE
NA
# CONTAINERS
2
MATERIAL CODE
PE
VOLUME 1 liter
SAMPLE PRESERVATION
PRESERVATIVE USED
None
TOTAL VOL ADDED IN FIELD (mL)
None
FINAL pH
NA
INTENDED ANALYSIS AND/OR
METHOD
PFOA, PFOS, &
SAMPLING EQUIPMENT
CODE
O-Grab
SAMPLE PUMP FLOW RATE
(mL per minute)
<100 m L
Fluorinated Cm ps
by H PLC/M S.
REMARKS: NA - Not Applicable.
UNK - Unknown.
Was the well pumping (active) prior to sampling Y e s) or No.
MS/MSD sample collected - Yes or (No) Collection Time:
Well has fluoride treatment - ^ e ijo r No.
Photograph No.
^
C P , r-~<\S b a f lM / U 2 '.
MATERIAL CODES:
A G = Amber Glass; C G = Clear Glass; P E = Polyethylene; PP = Polypropylene; S = Silicone; T =Teflon; O = Other (Specify)
'4M PLIN G EQUIPMENT COOES: A P P = After Peristaltic Pump;
B = Bailer; B P = Bladder Pump; ESP = Electric Submersible Pump;
RFPP = Reverse Flow Peristaltic Pump; SM = Straw Method (Tubing Gravity Drain); O = Other (Grab)
NOTES: 1. The above d o not constitute all of the Information required by Chapter 62-160, F.A.C. 2. S t a b il iz a t io n C r it e r ia f o r r a n g e o f v a r ia t io n o f l a s t t h r e e c o n s e c u t i v e r e a d in g s (s e e FS 2212, s e c t io n 3)
pH: + 0.2 units Temperature: + 0.2 C Specific Conductance: + 5% Dissolved Oxygen: all readings < 20% saturation (see Table FS 2200-2); optionally, + 0.2 mg/L or + 10% (whichever Is greater) Turbidity: all readings <20 NTU; optionally + 5 NTU or + 10% (whichever is greater)
Revision Date: February 12, 2009
GROUNDWATER SAMPLING LOG
p . 91
SITE NAME: ECUA Water Distribution System (County-wide)
SITE LOCATION: Escambia County, Florida
V E L L N O : / i; , p o r f- / ) / 0 f t V\
SAM PLE ID:
DATE: February ^ , 2010
PURGING DATA
W ELL CASING
-,
TUBING
W ELL SC R E EN INTERVAL
PUMPING WATER
PURGE PUMP TYPE:
DIAMETER (inches): J
DIAMETER (inches): NA
DEPTH:
UNK
LEVEL (feet): UNK
Existing Pump
W ELL VOLUME PURGE: 1 W ELL VOLUME = (TOTAL WELL DEPTH - STATIC DEPTH TO WATER) X WELL CAPACITY
(only fill out If applicable)
gallons
=( X 4 +
feet-
UNK
EQUIPM ENT VO LU M E PURGE: 1 EQUIPMENT VOL. = PU M P VOLUME + (TUBING CAPACITY
feet) X
gallons/foot
X TUBING LENGTH) + FLOW CELL VOLUME
(only fill out if applicable)
= gallons + (
gallons/foot X
feet) +
gallons :
gallons
PU M P DEPTH IN W ELL (feet): UNK
TIME (CST)
VOLUME PURGED (gallons)
CUMUL. VOLUME PURGED (gallons)
0 7 /S'
o ?/e
FINAL PUMP DEPTH IN W ELL (feet): UNK
PURGING
Q
INITIATED AT: / O
PURGE RATE
(gpm)
ORP (mV)
pH (standard
units)
TEMP. (C)
4*8 ? U 7 7
COND. (pS/cm)
/os'
L?H (
2/- 7 8
i/o /o7~
PURGING ENDED AT:
DISSOLVED OXYGEN (mg/L)
T~3 D
I-! 7
V 3o
TOTAL VOLUME PURGED (gallons):
TURBIDITY (NTUs)
COLOR (describe)
ODOR (describe)
Clear
None
Clear
None
Clear
None
/E L L CA PA CITY (Gallons Per Foot): 0.75" = 0.02; 1" = 0.04; 1.25" = 0.06; 2" = 0.16; 3" = 0.37; 4" = 0.65; 5" = 1.02; 6" = 1.47; 12" = 5.88 TUBING INSIDE DIA. CA PA CIT Y (Gal./Ft.): 1/8" = 0.0006; 3/16* = 0.0014; 1/4" =0.0026; 5/16" = 0.004; 3/8" = 0.006; 1/2" = 0.010; 5/6" = 0.016
PURGING EQUIPMENT CODES: B = Bailer; B P = Bladder Pump;
E SP = Electric Submersible Pump; PP = Peristaltic Pump;
0 = Other (Specify)
SAMPLING DATA
S A M PLED BY (PRINT) / AFFILIATION: David L. Anderson/CDM
SAMPLER(S) SIGNATURE(S):
SAMPLING
-,
INITIATED AT: O y - ^ 0
SAMPLING ENDED AT:
PU M P DEPTH IN W ELL (feet): UNK
TUBING MATERIAL CODE: NA
FIELD-FILTERED: No
FILTER SIZE: NA
Filtration Equipment Type: NA
urn
FIELD DECONTAMINATION:
PUMP: No
TUBING: NA
DUPLICATE:
No
SAMPLE CONTAINER SPECIFICATION
SAMPLE ID CODE
NA
# CONTAINERS
2
MATERIAL CODE
PE
VOLUME I liter
SAMPLE PRESERVATION
PRESERVATIVE USED
None
TOTAL VOL ADDED IN FIELD (mL)
None
FINAL pH NA
INTENDED ANALYSIS AND/OR
METHOD
PFOA, PFOS, &
SAMPLING EQUIPMENT
CODE
O-Grab
SAMPLE PUMP FLOW RATE
(mL per minute)
<100 m L
Fluorinated Cmps
by HPLC/MS.
REMARKS: NA - Not Applicable.
UNK - Unknown.
W as the well pumping (active) prior to sampling -(Y@) or No.
MS/MSD sample collected - Yes or
Collection Time:
Well has fluoride treatment-^Yegiiir No.
Photograph No. (p C $ a 4-c V\ | ^
C A -r.-w j- Jk^.r+K / (q2. .
MATERIAL CODES:
A G = Amber Glass; C G = Clear Glass; P E = Polyethylene; PP = Polypropylene; S = Silicone; T =Teflon; O = Other (Specify)
SAMPLING EQUIPMENT CODES:
A PP = After Peristaltic Pump;
B = Bailer; B P = Bladder Pump; E SP = Electric Submersible Pump;
RFPP = Reverse Flow Peristaltic Pump; SM = Straw Method (Tubing Gravity Drain): O = Other (Grab)
i.oTES: 1. The above do not constituteall of the information required by Chapter 62-160, F.A.C.
2. STABILIZATION CRITERIA FOR RANGE OF VARIATION OF LAST THREE CONSECUTIVE READINGS (SEE F S 2212. SECTION 3)
pH: + 0.2 units Temperature: + 0.2 C Specific Conductance: + 5% Dissolved Oxygen: all readings < 20% saturation (see Table FS 2200-2); optionally, + 0.2 mg/L or + 10% (whichever is greater) Turbidity: all readings < 20 NTU; optionally + 5 NTU or + 10% (whichever is greater)
Revision Date; February 12, 2009
GROUNDWATER SAMPLING LOG
SITE NAME: ECUA Water Distribution System (Countv-wide)
SITE LOCATION: Escambia Countv. Florida
VELLNO :/hC / V / ; ^ W
SAMPLE ID:
PURGING DATA
DATE: February 3 , 2010
WELL CASING
. TUBING
WELL SCREEN INTERVAL
PUMPING WATER
PURGE PUMP TYPE:
DIAMETER (inches): ^
DIAMETER (inches): NA
DEPTH:
UNK
LEVEL (feet): UNK
Existing Pump
WELL VOLUME PURGE: (only fill out if applicable)
gallons
1 WELL VOLUME = (TOTAL W ELL DEPTH -
= ( 2. V2.
feet -
STATIC DEPTH TO WATER) X WELL CAPACITY
UNK
feet) X
gallons/foot =
EQUIPMENT VOLUME PURGE: 1 EQUIPMENT VOL. = PUMP VOLUME +(TUBING CAPACITY X
(only fill out if applicable)
= gallons+(
gallons/foot X
TUBING LENGTH) + FLOW CELL VOLUME
feet) -r-
gallons =
gallons
PUM P DEPTH IN W ELL (feet): UNK
TIME (CST)
VOLUME PURGED
(gallons)
CUMUL. VOLUME PURGED (gallons)
>???
o fy z
o<? /(p
FINAL PUM P DEPTH IN W ELL (feet); UNK
PURGE RATE
(gpm)
ORP (mV)
*HS
TV*
S31
pH (standard
units)
S-S'?
PURGING
_ I PURGING
INITIATED AT. 7 J 3 | ENDED AT:
TEMP. (C)
COND. (pS/cm)
DISSOLVED OXYGEN (mg/L)
2 2 - 0 fc 22-07
2.
?.ofe 7 .02.
22-/0
O
TOTAL VOLUME PURGED (gallons):
TURBIDITY (NTUs)
COLOR (describe)
ODOR (describe)
O
Clear
None
O
Clear
None
0
C le a r
None
YELL CAPACITY (Gallons Per Foot): 0.75" = 0.02; 1" = 0.04; 1.25" = 0.06; 2" = 0.16; 3" =0.37; 4" = 0.65; 5" =1.02; 6" =1.47; 12" = 5.88 TUBING INSIDE DlA. CAPACITY (Gal./Ft ): 1/8" =0.0000; 3/16" = 0.0014; 1/4" =0.0026; 5/16" =0.004; 3/8" =0.006; 1/2" =0.010; 5/8" =0.016
PURGING EQUIPMENT CODES: B =Bailer; BP =Bladder Pump;
ESP = Electric Submersible Pump;
PP = Peristaltic Pump;
O =Other (Specify)
SAM PLED B Y (PRINT) / AFFILIATION: David L. Anderson/CDM
SAMPLING DATA
SAMPLER(S) SIGNATURE(S):
SAMPLING
iQ
INITIATED AT: 7 V 7
SAMPLING ENDED AT:
PUMP DEPTH IN W ELL (feet): UNK
FIELD DECONTAMINATION:
PUMP: No
TUBING MATERIAL CODE: NA
TUBING: NA
FIELD-FILTERED: No Filtration Equipment Type:
DUPLICATE:
NA
FILTER SIZE: No
NA
urn
SAMPLE CONTAINER SPECIFICATION
SAMPLE ID CODE
NA
# CONTAINERS
2
MATERIAL CODE
PE
VOLUME 1 liter
SAMPLE PRESERVATION
PRESERVATIVE USED
None
TOTAL VOL ADDED IN FIELD (mL)
None
FINAL pH NA
INTENDED ANALYSIS AND/OR
METHOD
PFOA, PFOS, &
Fluorlnated Cmps
SAMPLING EQUIPMENT
CODE
O-Grab
SAMPLE PUMP FLOW RATE
(mL per minute)
<100 mL
by HPLC/MS.
REMARKS: NA - Not Applicable.
UNK - Unknown.
Was the well pumping (active) prior to sampling -(Ye^) or No.
MS/MSD sample collected ^Yes) or No. Collection Time: * 3 7 ^ * 7
Well has fluoride treatment
or No.
Photograph No. - f -
V\ \
C A T f A j toff* y ? o ' .
MATERIAL CODES:
A G = Amber Glass; CG = Clear Glass; PE = Polyethylene; PP = Polypropylene; S = Silicone; T = Teflon; O = Other (Specify)
"AMPLING EQUIPMENT CODES:
A P P = After Peristaltic Pump;
B = Bailer; B P = Bladder Pump; ESP = Electric Submersible Pump;
RFPP = Reverse Flow Peristaltic Pump; SM = Straw Method (Tubing Gravity Drain); O = Other (Grab)
ivuTES: 1. The above do not constitute all of the Information required by Chapter 62-160, F.A.C. 2. S t a b il iz a t io n C r it e r ia f o r r a n g e o f v a r ia t io n o f l a s t t h r e e c o n s e c u t i v e r e a d in g s (s e e FS 2212, s e c t io n 3)
pH: +0.2 units Temperature: +0.2 C Specific Conductance: + 5% Dissolved Oxygen: all readings <20% saturation (see Table FS 2200-2); optionally, + 0.2 mg/L or + 10% (whichever Is greater) Turbidity: all readings <20 NTU; optionally +5 NTU or + 10% (whichever is greater)
Revision Date: February 12, 2009
GROUNDWATER SAMPLING LOG
p. 93
SITE NAME: ECUA Water Distribution System (County-wide)
SITE LOCATION: Escambia County, Florida
WELL NO:
A / / i/ W
SAM PLE ID:
J
DATE: February 3" . 2010
PURGING DATA
WELL CASING
TUBING
WELL SCREEN INTERVAL
PUMPING WATER
PURGE PUMP TYPE:
DIAMETER (inches): -2 (o DIAMETER (Inches): NA
DEPTH:
UNK
LEVEL (feet): UNK
Existing Pump
WELL VOLUME PURGE: 1 WELL VOLUME = (TOTAL W ELL DEPTH - STATIC DEPTH TO WATER) X W ELL CAPACITY
(only fill out if applicable)
= ( X V2.
feet -
UNK
feet) X
gallons/foot =
qallons
EQUIPMENT VOLUME PURGE: 1 EQUIPMENT VOL. = PUM P VOLUME +(TUBING CAPACITY X TUBING LENGTH) +FLOW CELL VOLUME
(only fill out if applicable)
= gallons + (
gallons/foot X
feet) +
gallons =
gallons
PU M P DEPTH IN W ELL (feet): UNK
TIME (CST)
VOLUME PURGED (gallons)
CUMUL. VOLUME PURGED (qallons)
o^sz
0 <k 8
FINAL PUMP DEPTH IN W ELL (feet): UNK
PURGE RATE (gpm)
ORP (mV)
ui ,2e? 13 o
pH (standard
units)
-7-2 g
7--2U
PURGING INITIATED AT: 7 3 3
TEMP. <C)
COND. (pS/cm)
Zo.qz 2o.cfl
IS*
/SB
IS*
PURGING ENDED AT:
DISSOLVED OXYGEN (mg/L)
/V i" 3 .si 3. So
TOTAL VOLUME PURGED (gallons):
TURBIDITY (NTUs)
z
1 1
COLOR (describe)
Clear Clear Clear
ODOR (describe)
None None None
WELL CAPACITY (Gallons Per Foot): 0.75" =0.02; 1" =0.04; 1.25" = 0.06; 2" =0.16; 3" =0.37; 4" =0.65; 5" =1.02; 6 " =1.47; 12" =5.88 TUBING INSIDE DIA. CAPACITY (Gal./Ft.): 1/8" =0.0006; 3/16" =0.0014; 1/4" =0.0026; 5/16" =0.004; 3/8" =0.006; 1/2" =0.010; ii/8" =0.016
PURGING EQUIPMENT CODES: B =Bailer; BP =Bladder Pump;
ESP =Electric Submersible Pump;
PP = Peristaltic Pump;
0 =Other (Specify)
SAMPLING DATA
S A M PLED B Y (PRINT) / AFFILIATION: David L. Anderson/CDM
S/\MPLER(S) SIGNATURE(S):
SAMPLING INITIATED AT: / O *
SAMPLING ENDED AT:
PU M P DEPTH IN W ELL (feet): UNK
FIELD DECONTAMINATION:
PUMP: No
TUBING MATERIAL CODE: NA
TUBING: NA
FIELD-FILTERED: No Filtration Equipment Type:
DUPLICATE:
NA
FILTER SIZE: No
NA
urn
SAM PLE CONTAINER SPECIFICATION
SAMPLE ID CODE
NA
If CONTAINERS
2
MATERIAL CODE
PE
VOLUME 1 liter
SAMPLE PRESERVATION
PRESERVATIVE USED
None
TOTAL VOL ADDED IN FIELD (mL)
None
FINAL pH NA
INTENDED ANALYSIS AND/OR
METHOD
PFOA, PFOS, &
SAMPLING EQUIPMENT
CODE
O-Grab
SAMPLE PUMP FLOW RATE
(mL per minute)
<100 mL
Fluorinated Cmps
by HPLC/MS.
REMARKS: NA - Not Applicable.
UNK - Unknown.
W as the well pumping (active) prior to sampling - ^ e s ) or No.
MS/MSD sample collected -(Yes) or No. Collection Time:
Well has fluoride treatment fYespor No.
Photograph No.
C -B a V c -H ) ")
C A r.- i\.f Aer+K t l o ' .
MATERIAL CODES:
A G =Amber Glass; C G = Clear Glass; PE = Polyethylene; PP = Polypropylene; S = Silicone; T =Teflon; O = Other (Specify)
SAM PLIN G EQUIPMENT CODES: A P P = After Peristaltic Pump;
B = Bailer; B P = Bladder Pump; E S P = Electric Submersible Pump;
R FPP = Reverse Flow Peristaltic Pump; SNI = Straw Method (Tubing Gravity Drain); O = Other (Grab)
ivOTES: 1. The above do not constitute all of the information required by Chapter 62-160, F.A.C.
2 . S t a b i l i z a t io n C r i t e r ia f o r r a n g e o f v a r ia t io n of l a s t t h r e e c o n s e c u t i v e r e a d i n g s ( s e e F S 2 2 1 2 . s e c t io n 3)
pH: +0 .2 units Temperature: +0 .2 C Specific Conductance: 5 % Dissolved Oxygen: all readings <2 0 % saturation (see Table F S 2 2 0 0 -2 ); optionally, + 0 . 2 mg/L or + 1 0 % (whichever is greater) Turbidity: all readings < 2 0 NTU; optionally +5 NTU or + 1 0 % (whichever Is greater)
Revision Date: February 12, 2009
V VW
GROUNDWATER SAMPLING LOG
p. 94
SITE NAME: ECUA Water Distribution System (Countv-wide)
SITE LOCATION: Escambia Countv. Florida
VELLN0:
SAMPLE ID:
DATE: February 3 ,2010
PURGING DATA
WELL CASING
o
DIAMETER (inches):
TUBING DIAMETER (inches): NA
WELL SCREEN INTERVAL
DEPTH:
UNK
PUMPING WATER LEVEL (feet): UNK
PURGE PUMP TYPE: Existing Pump
WELL VOLUME PURGE: 1 WELL VOLUME = (TOTAL W ELL DEPTH - STATIC DEPTH TO WATER) X W ELL CAPACITY
(only fill out if applicable)
= ( 7L lob
feet -
UNK
feet) X
gallons/foot =
gallons
EQUIPMENT VOLUME PURGE: 1 EQUIPMENT VOL. = PU M P VOLUME + (TUBING CAPACITY X TUBING LENGTH) + FLOW CELL VOLUME
(only fill out If applicable)
= gallons + (
gallons/foot X
feet) +
gallons =
gallons
PUMP DEPTH IN W ELL (feet): UNK
TIME (CST)
VOLUME PURGED (gallons)
CUMUL. VOLUME PURGED (gallons)
/o
/>*/<o
As rc
FINAL PUMP DEPTH IN W ELL (feet): UNK
PURGING INITIATED AT: / O V 0
PURGE RATE (gpm)
ORP (mV)
-- -
pH (standard
units)
TEMP. (C)
(d -B % C-81 C&3
Z 2.2 .G
2 2 .2 .1 2 2 .2 \
COND. (nS/cm)
n 7-8
PURGING ENDED AT:
DISSOLVED OXYGEN (mg/L)
S '?
6 ,-U .2 .
TOTAL VOLUME PURGED (gallons):
TURBIDITY (NTUs)
COLOR (describe)
ODOR (describe)
0
Clear
None
O
Clear
None
0
Clear
None
I
,/ELL CAPACITY (Gallons Per Foot): 0.75" = 0.02; 1" = 0.04; 1.25" = 0.06; 2" = 0.16; 3" = 0.37; 4" =0.65; 5" =1.02; 6" = 1.47; 12" =5.88 TUBING INSIDE DIA. CAPACITY(Gal./Ft.): 1/8" = 0.0006; 3/16" = 0.0014; 1/4" = 0.0026; 5/16" = 0.004; 3/8" = 0.006; 1/2" = 0.0f0; 5/8" = 0.016
PURGING EQUIPMENT CODES: B = Bailer; BP = Bladder Pump;
ESP = Electric Submersible Pump;
PP = Peristaltic Pump;
O = Other (Specify)
SAMPLING DATA
SAMPLED B Y (PRINT) / AFFILIATION: David L. Anderson/CDM
SAMPLER(S) SIGNATURE(S): uL*-- R w U y
SAMPLING . INITIATED AT: / C S 5 "
SAMPLING ENDED AT:
PUMP DEPTH IN W ELL (feet): UNK
TUBING MATERIAL CODE: NA
FIELD-FILTERED: No
FILTER SIZE: NA
Filtration Equipment Type: NA
urn
FIELD DECONTAMINATION:
PUMP: No
TUBING: NA
DUPLICATE:
No
SAMPLE CONTAINER SPECIFICATION
SAMPLE ID CODE
NA
# CONTAINERS
2
MATERIAL CODE
PE
VOLUME 1liter
SAMPLE PRESERVATION
PRESERVATIVE USED
None
TOTAL VOL ADDED IN FIELD (mL)
None
FINAL pH NA
INTENDED ANALYSIS AND/OR
METHOD
PFOA, PFOS, &
Fiuorinated Cmps
SAMPLING EQUIPMENT
CODE
O-Grab
SAMPLE PUMP FLOW RATE
(mL per minute)
<100 mL
by HPLC/MS.
REMARKS: NA - Not Applicable.
UNK - Unknown.
Was the well pumping (active) prior to sampling
or No.
MS/MSD sample collected - Yes or(7t^ Collection Time:
Well has fluoride tre atm e nt-^ ^ or No.
Photograph No. / ( # a +c V> Z l)
c p i c Wr V \ /L fC '.
MATERIAL CODES:
A G = Amber Glass; CG = Clear Glass; P E = Polyethylene; PP = Polypropylene; S = Silicone; T = Teflon; O = Other (Specify)
'A M P LIN G EQUIPMENT CODES: A P P = After Peristaltic Pump;
B = Bailer; B P = Bladder Pump; E S P = Electric Submersible Pump;
R FPP - Reverse Flow Peristaltic Pump; SM = Straw Method (Tublng Gravity Drain); O - Other (Grab)
NOTES: 1. The above do not constitute all of the information required by Chapter 62-160, F.A.C.
2. S t a b il iz a t io n C r it e r ia f o r r a n g e o f v a r ia t io n o f l a s t t h r e e c o n s e c u t i v e r e a d i n g s (s e e F S 2 2 1 2 , s e c t io n 3)
pH: +0.2 units Temperature: + 0.2 C Specific Conductance: +5% Dissolved Oxygen: ail readings <20% saturation (see Table FS 2200-2); optionally, + 0.2 mg/L or + 10% (whichever is greater) Turbidity: all readings <20 NTU; optionally +5 NTU or + 10% (whichever is greater)
Revision Date: February 12, 2009
I W h/WVfc-T
GROUNDWATER SAMPLING LOG
SITE NAME: E C U A Water Distribution System (County-wide)
SITE LOCATION: Escambia County, Florida
V ELL NO:
r g y 'J
SAM PLE ID:
J
PURGING DATA
DATE: February
2010
WELL CASING
TUBING
W ELL SCREEN INTERVAL
PUMPING WATER
PURGE PUMP TYPE:
DIAMETER (Inches): ->
DIAMETER (inches): NA
DEPTH:
UNK
LEVEL (feet): UNK
Existing Pump
WELL VOLUME PURGE: 1 WELL VOLUME = (TOTAL W ELL DEPTH - STATIC DEPTH TO WATER) X W ELL CAPACITY
(only fill out if applicable)
= ( 2. t S
feet-
UNK
qallons
EQUIPMENT VOLUME PURGE: 1 EQUIPMENT VO L = PUM P VOLUME + (TUBING CAPACITY X
(only fill out If applicable)
= gallons + (
gallons/foot X
feet) X
gallons/foot =
TUBING LENGTH) + FLOW CELL VOLUME
feet) +
gallons =
gallons
PU M P D EPTH IN W E LL (feet): UNK
TIME (CST)
VOLUME PURGED (gallons)
CUMUL. VOLUME PURGED (gallons)
/ D i' 8
// /
//o< y
FINAL PUMP DEPTH IN W ELL (feet): UNK
PURGING
.,,
INITIATED AT: / " &
PURGE RATE
(gpm)
ORP (mV)
LVe
pH (standard
units)
TEMP. (C)
6 > . V .2 /-? o
(e. 7 1 2j.
COND. (gS/cm)
/ io /< e ?
(o 3 J
2 /.1 0
/ to
PURGING ENDED AT:
DISSOLVED OXYGEN (mg/L)
r.s ?
TOTAL VOLUME PURGED (gallons):
TURBIDITY COLOR
(NTUs)
(describe)
ODOR (describe)
o
Clear
None
Clear
None
Clear
None
/ELL CAPACITY (Gallons Per Foot): 0.75" = 0.02; 1" = 0.04; 1.25" = 0.06; 2" = 0.16; 3" = 0.37; 4" = 0.65; 5" = 1.02; 6" = 1.47; 12" = 5.88 TUBING INSIDE DIA. CAPACITY (Gal./Ft.): 1/8" = 0.0006; 3/16" = 0.0014; 1/4" = 0.0026; 5/16" =0.004; 3/8" = 0.006; 1/2" = 0.010; 6/8" = 0.016
PURGING EQUIPMENT CODES: B = Bailer; BP = Bladder Pump;
ESP = Electric Submersible Pump;
PP = Peristaltic Pump;
O = Other (Specify)
SAMPLING DATA
SA M PLED B Y (PRINT) / AFFILIATION; David L. Anderson/CDM
5WMPLER(S)SIGNATURE(S):
SAMPLING INITIATED AT: / / 6
SAMPLING ENDED AT:
PU M P DEPTH IN W ELL (feet): UNK
FIELD DECONTAMINATION:
PUMP: No
TUBING MATERIAL CODE; NA
TUBING: NA
FIELD-FILTERED: No Filtration Equipment Type:
DUPLICATE:
NA
FILTER SIZE: No
NA
um
SAM PLE CONTAINER SPECIFICATION
SAMPLE ID CODE
NA
# CONTAINERS
2
MATERIAL CODE
PE
VOLUME
1liter
SAMPLE PRESERVATION
PRESERVATIVE USED
None
TOTAL VOL ADDED IN FIELD (mL)
None
FINAL PH
NA
INTENDED ANALYSIS AND/OR
METHOD
PFOA, PFOS, &
SAMPLING EQUIPMENT
CODE
O-Grab
SAMPLE PUMP FLOW RATE
(mL per minute)
<100 m L
Fluorinated Cmps
by HPLC/MS.
REMARKS: NA - Not Applicable.
UNK - Unknown.
W as the well pumping (active) prior to sampling( Y e j) o r No.
MS/MSD sample collected - Yes or ( N o3 Collection Time:
Well has fluoride treatment^Yej) or No.
Photograph No. f ^+.4-^ J2. (L -a A - ^ K
C A /riij-
/y r '.
MATERIAL CODES:
A G = Amber Glass; C G = Clear Glass; PE = Polyethylene; PP = Polypropylene; S = Silicone; T =Teflon; O = Other (Specify)
SAMPLING EQUIPMENT CODES:
A P P = After Peristaltic Pump;
B = Bailer; B P = Bladder Pump; E S P = Electric Submersible Pump;
RFPP = Reverse Flow Peristaltic Pump; SM = Straw Method (Tubing Gravity Drain); O = Other (Grab)
iiOTES: 1. The above do not constitute all of the information required by Chapter 62-160, F.A.C.
2. Stabilization Criteria for range of variation of last three consecutive readings (see F S 2212. section 3)
pH: + 0.2 units Temperature: + 0.2 C Specific Conductance: +5% Dissolved Oxygen: all readings < 20% saturation (see Table FS 2200-2); optionally, 0.2 mg/L or + 10% (whichever is greater) Turbidity: all readings < 20 NTU; optionally + 5 NTU or + 10% (whichever is greater)
Revision Date: February 12, 2009
GROUNDWATER SAMPLING LOG
SITE NAME: ECUA Water Distribution System (Countv-wlde)
SITE LOCATION: Escambia Countv. Florida
A/ELLNO: j$ / - 0 A 4
SAMPLE ID:
DATE: February
,2010
PURGING DATA
WELL CASING
-n
TUBING
WELL SCREEN INTERVAL
PUMPING WATER
PU RGE PUMP TYPE:
DIAMETER (inches):
DIAMETER (inches): NA
DEPTH:
UNK
LEVEL (feet): UNK
Existing Pump
WELL VOLUME PURGE: (only fill out if applicable)
gallons
1 W ELL VOLUME = (TOTAL WELL DEPTH = ( feet-
STATIC DEPTH TO WATER) X WELL CAPACITY
UNK
feet) X
gallons/foot =
EQUIPMENT VOLUM E PURGE: 1 EQUIPMENT VOL. = PUMP VOLUME + (TUBING CAPACITY X
(only fill out if applicable)
= gallons + (
gallons/foot X
TUBING LENGTH) + FLOW CE LL VOLUME
feet) +
gallons :
gallons
PUMP DEPTH IN W ELL (feet): UNK
TIME (CST)
VOLUME PURGED (gallons)
CUMUL. VOLUME PURGED (gallons)
1178
//Ml
FINAL PUMP DEPTH IN W ELL (feet): UNK
PURGING
,
INITIATED AT: / / 3 5
PURGING ENDED AT:
PURGE
RATE
(gpm)
ORP (mV)
3 383
pH (standard
units)
TEMP. (C)
U . 3 5 - 2-1- 2 1
COND. (pS/cm)
(d 3 s
DISSOLVED OXYGEN (mg/L)
s .n
r-2 o
311
6 - 3 3 2 / -2-1
6>t/
$ '8
TOTAL VOLUME PURGED (gallons):
TURBIDITY (NTUs)
COLOR (describe)
ODOR (describe)
Clear Clear Clear
None None None
V E L L CAPACITY (Gallons Per Foot): 0.75" = 0.02; 1" = 0.04; 1.25" = 0.06; 2" = 0.16; 3" = 0.37; 4" =0.65; 5" = 1.02; 6" = 1.47; 12" =5.88 TUBING INSIDE DIA. CA PA CIT Y (Gal./Ft ): 1/8" =0.0006; 3/16" =0.0014; 1/4" = 0,0026; 5/16" = 0,004; 3/8" = 0.006; 1/2" =0.010; 5/8" =0.016
PURGING EQUIPMENT CODES: B = Bailer; B P = Bladder Pump;
E S P = Electric Submersible Pump;
PP = Peristaltic Pump;
O = Other (Specify)
SAMPLED BY (PRINT) / AFFILIATION: David L. Anderson/CDM
SAMPLING DATA
SAMPLER(S) SIGNATURE(S):
SAMPLING
., u ,
INITIATED AT: / / 7 uj
SAMPLING ENDED AT:
PUMP DEPTH IN W ELL (feet): UNK
FIELD DECONTAMINATION:
PUMP: No
TUBING MATERIAL CODE: NA
TUBING: NA
FIELD-FILTERED: No Filtration Equipment Type:
DUPLICATE:
NA
FILTER SIZE: No
NA
urn
SAMPLE CONTAINER SPECIFICATION
SAMPLE ID CODE
NA
# CONTAINERS
2
MATERIAL CODE
PE
VOLUME I liter
SAMPLE PRESERVATION
PRESERVATIVE USED
None
TOTAL VOL ADDED IN FIELD (mL)
None
FINAL pH
NA
INTENDED ANALYSIS AND/OR
METHOD
PFOA, PFOS, &
Fluorinated Cmps
SAMPLING EQUIPMENT
CODE
O-Grab
SAMPLE PUMP FLOW RATE
(mL per minute)
<100 m L
by HPLC/MS.
REMARKS: NA - Not Applicable.
UNK - Unknown.
Was the well pumping (active) prior to sampling -^ eS) or No.
MS/MSD sample collected -Y es or ^o^)Collection Time:
Well has fluoride treatment VYes)or No.
Photograph No. 3 C B a V c.V\ J2.")
r-'rv j
MATERIAL CODES:
A G = Amber Glass; CG = Clear Glass; PE = Polyethylene; PP = Polypropylene; S = Silicone; T = Teflon; O = Other (Specify)
~AMPLING EQUIPMENT CODES: A P P = After Peristaltic Pump;
B = Bailer; B P = Bladder Pump; ESP = Electric Submersible Pump;
RFPP = Reverse Flow Peristaltic Pump; SM = Straw Method (Tubing Gravity Drain); O = Other (Grab)
NOTES: 1. The above do not constitute all of the Information required by Chapter 62-160, F.A.C.
2. S T A B IL IZ A T IO N C R I T E R I A F O R R A N G E O F V A R IA T IO N O F L A S T T H R E E C O N S E C U T I V E R E A D I N G S ( S E E F S 2212, S E C T IO N 3)
pH: + 0.2 units Temperature: 0.2 C Specific Conductance: +5% Dissolved Oxygen: all readings < 20% saturation (see Table FS 2200-2); optionally, 0.2 mg/L or + 10% (whichever is greater) Turbidity: all readings < 20 NTU; optionally + 5 NTU or + 10% (whichever is greater)
Revision Date: February 12, 2009
GROUNDWATER SAMPLING LOG
p. 97
SITE NAME: ECU A Water Distribution System (County-wide)
SITE LOCATION: Escambia County, Florida
VELLNO: $ , 0 * J S-\-
SAM PLE ID:
DATE: February 3 2010
PURGING DATA
W ELL CASING
TUBING
WELL SCREEN INTERVAL
PUMPING WATER
PURGE PUMP TYPE:
DIAMETER (inches):
DIAMETER (inches): NA
DEPTH:
UNK
LEVEL (feet): UNK
Existing Pump
WELL VOLUME PURGE: 1 WELL VOLUME = (TOTAL W ELL DEPTH - STATIC DEPTH TO WATER) X W ELL CAPACITY
(only fill out if applicable)
.
=( JZt I
feet -
UNK
gallons
EQUIPMENT VOLUME PURGE: 1 EQUIPMENT VOL. = PUM P VOLUME + (TUBING CAPACITY
feet) X
gallons/foot =
X TUBING LENGTH) + FLOW CELL VOLUME
(only fill out if applicable)
= gallons + (
gallons/foot X
feet) +
gallons =
gallons
PU M P D EPTH IN W ELL (feet); UNK
TIME (CST)
VOLUME PURGED (gallons)
CUMUL. VOLUME PURGED (gallons)
tm
i/s z
FINAL PUMP DEPTH IN W ELL (feet): UNK
PURGE RATE (gpm)
ORP (mV)
(d C ip
pH (standard
units)
7 -zs"
PURGING
//y r
INITIATED AT: U J -S
TEMP. (C)
COND. (pS/cm)
SCI .1 o
2 - ?o
//o //O //o
PURGING ENDED AT:
DISSOLVED OXYGEN (mg/L)
r.$ 2
r . ?- u
r . f <o
TOTAL VOLUME PURGED (gallons):
TURBIDITY (NTUs)
COLOR (describe)
ODOR (describe)
C le a r
None
/
C le a r
None
C
C le a r
None
,,ELL CAPACITY (Gallons Per Foot): 0.75" = 0.02; 1" = 0.04; 1.25" = 0.06; 2" = 0.16; 3" = 0.37; 4" = 0.65; 5"=1.02; 6" = 1.47; 12" = 5.88 TUBING INSIDE DIA. CAPACITY (GaliFt.): 1/8" = 0.0006; 3/16" = 0.0014; 1/4" = 0.0026; 5/16" = 0.004; 3/8" = 0.006; 1/2" = 0.010; 5/8" =0.016
PURGING EQUIPMENT CODES: B = Bailer; BP = Bladder Pump;
ESP = Electric Submersible Pump;
PP = Peristaltic Pump;
O = Other (Specify)
SAMPLING DATA
SA M PLE D B Y (PRINT) / AFFILIATION: David L. Anderson/CDM
SAMPLER(S) SIGNATURE(S):
SAMPLING
.-
INITIATED AT: / - 2 a 6
SAMPLING ENDED AT:
PU M P DEPTH IN W ELL (feet): UNK
FIELD DECONTAMINATION:
PUMP: No
TUBING MATERIAL CODE: NA
TUBING: NA
FIELD-FILTERED: No Filtration Equipment Type:
DUPLICATE:
NA
FILTER SIZE: No
NA
urn
SA M PLE CONTAINER SPECIFICATION
SAMPLE ID CODE
NA
# CONTAINERS
2
MATERIAL CODE
PE
VOLUME 1liter
SAMPLE PRESERVATION
PRESERVATIVE USED
None
TOTAL VOL ADDED IN FIELD (mL)
None
FINAL
pH NA
INTENDED ANALYSIS AND/OR
METHOD
PFOA, PFOS, &
Fluorinated Cmps
SAMPLING EQUIPMENT
CODE
O-Grab
SAMPLE PUMP FLOW RATE
(mL per minute)
<100 mL
by HPLC/MS.
REMARKS: NA - Not Applicable.
UNK - Unknown.
W as the well pumping (active) prior to sampling -^Yes) or No.
MS/MSD sample collected - Yes or ( nq^) Collection Time:
Well has fluoride treatm ent^ YesV No.
Photograph No.
C 3 A+
2-3)
c W H \ / 4 ? '.
MATERIAL CODES:
A G =Amber Glass; CG = Clear Glass; PE = Polyethylene; PP = Polypropylene; S = Silicone; T = Teflon; O = Other (Specify)
SAMPLING EQUIPMENT CODES:
A P P = After Peristaltic Pump;
B = Bailer; B P = Bladder Pump; E S P = Electric Submersible Pump;
RFPP = Reverse Flow Peristaltic Pump; SM = Straw Method (Tubing Gravity Drain); O = Other (Grab)
NuTES: 1. The above do not constitute all of the Information required by Chapter 62-160, F.A.C.
2. Stabilization Criteria for range of variation of last three consecutive readings (see F S 2212. section 3)
pH: + 0.2 units Temperature: + 0.2 C Specific Conductance: +5% Dissolved Oxygen: all readings < 20% saturation (see Table FS 2200-2); optionally, +0.2 m g/Lor + 10% (whichever is greater) Turbidity: all readings <20 NTU; optionally + 5 NTU or + 10% (whichever is greater)
Revision Date: February 12, 2009
GROUNDWATER SAMPLING LOG
p. 98
SITE NAME: ECUA Water Distribution System (Countv-wide)
SITE LOCATION: Escambia County, Florida
A/ELLNO: ' 7 ^ A r ,A A 4 -
SAMPLE ID: R p i U j
DATE: February 3
,2010
PURGING DATA
WELL CASING DIAMETER (Inches):
TUBING DIAMETER (Inches): NA
WELL SCREEN INTERVAL
DEPTH:
UNK
PUMPING WATER LEVEL (feet): UNK
PU RGE PUMP TYPE: Existing Pump
W ELL VOLUME PURGE: 1 W ELL VOLUME = (TOTAL WELL DEPTH STATIC DEPTH TO WATER) X WELL CAPACITY
(only fill out If applicable)
gallons
= ( JZ O g
feet-
UNK
feet) X
gallons/foot =
EQUIPMENT VO LU M E PURGE: 1 EQUIPMENT VOL. = PUM P VOLUME + (TUBING CAPACITY X TUBING LENGTH) + FLOW C E LL VOLUME
(only fill out if applicable)
= gallons + (
gallons/foot X
feet) +
gallons :
gallons
PUMP DEPTH IN W E LL (feet): UNK
TIME (CST)
VOLUME PURGED
(gallons)
CUMUL. VOLUME PURGED (gallons)
/S W
/If* /3 o *
FINAL PUMP DEPTH IN W ELL (feet): UNK
PURGING INITIATED AT:. / X Sb
PURGING ENDED AT:
PURGE RATE
(gpm)
ORP (mV)
3-M -
31$
311
pH (standard
units)
TEMP. (C)
S / (d 2 2 - 0 ^
r-n 1 -
22.
COND. (pS/cm)
SS
S"6
DISSOLVED OXYGEN (mg/L)
& /? b-l 8
TOTAL VOLUME PURGED (gallons):
TURBIDITY (NTUs)
COLOR (describe)
ODOR (describe)
Clear
None
&
Clear
None
Clear
None
/E L L C A PA CIT Y (Gallons Per Foot): 0.75" = 0.02; 1" = 0.04; 1.25" = 0.06; 2" = 0.16; 3" = 0.37; 4" =0.65; 5" = 1.02; 6" =1.47; 12" = 5.88 TUBING INSIDE DIA. C A PA C IT Y (Gal,/Ft.): 1/8" = 0.0006; 3/16" = 0.0014; 1/4" = 0.0026; 5/16" =0.004; 3/8" = 0.006; 1/2" = 0.010; 5/8" =0.016
PURGING EQUIPMENT CODES: B = Bailer;
SAM PLED BY (PRINT) / AFFILIATION: David L. Anderson/CDM
B P = Bladder Pump;
E S P = Electric Submersible Pump;
PP = Peristaltic Pump;
SAMPLING DATA
SAMPLER(S) SIGNATURE(S):
SAMPLING
,, _
INITIATED AT: l - i ^ S
O =Other (Specify)
SAMPLING ENDED AT:
PUMP DEPTH IN W ELL (feet): UNK
TUBING MATERIAL CODE: NA
FIELD-FILTERED: No
FILTER SIZE: NA
Filtration Equipment Type: NA
urn
FIELD DECONTAMINATION:
PUMP: No
TUBING: NA
DUPLICATE:
No
SAMPLE CONTAINER SPECIFICATION
SAMPLE ID CODE
NA
# CONTAINERS
2
MATERIAL CODE
PE
VOLUME I liter
SAMPLE PRESERVATION
PRESERVATIVE USED
None
TOTAL VOL ADDED IN FIELD (mL)
None
FINAL pH NA
INTENDED ANALYSIS AND/OR
METHOD
PFOA, PFOS, &
Fluorinated Cmps
SAMPLING EQUIPMENT
CODE
O-Grab
SAMPLE PUMP FLOW RATE
(mL per minute)
<100 mL
by HPLC/MS.
REMARKS: NA - Not Applicable.
UNK - Unknown.
Was the well pumping (active) prior to sampling^Yes) or No.
MS/MSD sample collected - Yes or(N o) Collection Time:
Well has fluoride treatment ^Ye^or No.
Photograph No. $ " C
2 . ")
c ft/T n j
(c>
MATERIAL CODES:
A G =Amber Glass; CG = Clear Glass; PE = Polyethylene; P P = Polypropylene; S = Silicone; T = Teflon; O = Other (Specify)
SAMPLING EQUIPMENT CODES: A P P = After Peristaltic Pump; B = Bailer; B P = Bladder Pump; ESP = Electric Submersible Pump; RFPP = Reverse Flow Peristaltic Pump; SM = Straw Method (Tubing Gravity Drain); O = Other (Grab)
iwTES: 1. The above do not constituteall of the information required by Chapter 62-160, F.A.C.
2. S t a b iliz a t io n C r it e r ia f o r r a n g e o f v a r ia t io n o f l a s t t h r e e c o n s e c u t iv e r e a d in g s (s e e F S 2212. s e c t io n 3)
pH: + 0.2 units Temperature: + 0.2 C Specific Conductance: +5% Dissolved Oxygen: all readings <20% saturation (see Table FS 2200-2); optionally, + 0.2 mg/L or + 10% (whichever Is greater) Turbidity: all readings < 20 NTU; optionally + 5 NTU or + 10% (whichever Is greater)
Revision Date: February 12, 2009
GROUNDWATER SAMPLING LOG
SITE NAME: ECU A.Water Distribution System (County-wide)
SITE LOCATION: Escambia County, Florida
KELL NO: 7 e D R A n + -
SAM PLE ID:
DATE: February ^ ,2010
PURGING DATA
WELL CASING
TUBING
WELL SCREEN INTERVAL
PUMPING WATER
PURGE PUMP TYPE:
DIAMETER (inches): '2-<r
DIAMETER (inches): NA
DEPTH:
UNK
LEVEL (feet): UNK
Existing Pump
WELL VOLUME PURGE: 1 WELL VOLUME = (TOTAL W ELL DEPTH - STATIC DEPTH TO WATER) X W ELL CAPACITY
(only fill out If applicable)
= ( ^2. C> 8
feet -
UNK
feet) X
gallons/foot =
aallons
EQUIPMENT VOLUME PURGE: 1 EQUIPMENT V O L = PU M P VOLUME + (TUBING CAPACITY X TUBING LENGTH) + FLOW CELL VOLUME
(only fill out if applicable)
= gallons + (
gallons/foot X
feet) +
gallons =
gallons
PU M P DEPTH IN W ELL (feet): UNK
TIME (CST)
VOLUME PURGED (gallons)
CUMUL. VOLUME PURGED (gallons)
/3og
I3 H
13
FINAL PUMP DEPTH IN W ELL (feet): UNK
PURGING
., -
INITIATED AT: s 0
PURGING ENDED AT:
PURGE RATE (gpm)
ORP (mV)
c(p
pH (standard
units)
TEMP. (C)
? ./o
27- 0 5
COND. (gS/cm)
<7?
DISSOLVED OXYGEN (mg/L)
fc-i 8
<00?
7 -0 ? 7 -/o
2 2 .0 S
22. 0S
/o ?
/ c > 2.
L IZ
TOTAL VOLUME PURGED (gallons):
TURBIDITY (NTUs)
COLOR (describe)
ODOR (describe)
I
C le a r
None
C le a r
None
I
Clear
None
.ELL CAPACITY (Gallons Per Foot): 0.75" = 0.02; 1" = 0.04; 1.25" = 0.06; 2" = 0.16; 3" = 0.37; 4" = 0.65; 5" = 1.02; 6" = 1.47; 12" = 5.88 TUBING INSIDE DIA. CAPACITY (Gal./Ft ): 1/8" = 0.0006; 3/15" = 0.0014; 1/4" = 0.0026; 5/16" = 0.004; 3/8" = 0.006; 1/2" = 0.010; 5" = 0.016
PURGING EQUIPMENT CODES: B = Bailer; BP = Bladder Pump;
ESP = Electric Submersible Pump;
PP = Peristaltic Pump;
O = Other (Specify)
SA M PLED B Y (PRINT) / AFFILIATION: David L. Anderson/CDM
PU M P DEPTH IN W ELL (feet): UNK
SAMPLING DATA
SAMPLER(S) SIGNATURE(S):
fe o u w A x i/TUBING MATERIAL CODE: NA
SAMPLING
M
INITIATED AT: / J / +
SAMPLING ENDED AT:
FIELD-FILTERED: No
FILTER SIZE: NA
Filtration Equipment Type: NA
urn
FIELD DECONTAMINATION:
PUMP: No
TUBING: NA
DUPLICATE:
No
SAM PLE CONTAINER SPECIFICATION
SAMPLE ID CODE
NA
#
CONTAINERS
2
MATERIAL CODE
PE
VOLUME
1liter
SAMPLE PRESERVATION
PRESERVATIVE USED
None
TOTAL VOL ADDED IN FIELD (mL)
None
FINAL pH NA
INTENDED ANALYSIS AND/OR
METHOD
PFOA, PFOS, &
SAMPLING EQUIPMENT
CODE
O-Grab
SAMPLE PUMP FLOW RATE
(mL per minute)
<100 mL
Fluorinated Cmps
by HPLC/MS.
REMARKS: NA - Not Applicable.
UNK - Unknown.
W as the well pumping (active) prior to sampling ^Ye^) or No.
MS/MSD sample collected - Yes orf'^No) Collection Time:
Well has fluoride treatment -(Y'esfor No. /'Hk /T (e
Photograph No. (p ^ >p - \ c h 3 ")
MATERIAL CODES:
A G = Amber Glass; C G = Clear Glass; PE = Polyethylene; PP = Polypropylene; S = Silicone; T =Teflon; O = Other (Specify)
"A M P L IN G EQUIPMENT CODES: APP = After Peristaltic Pump;
B = Bailer; B P = Bladder Pump; E S P = Electric Submersible Pump;
RFPP = Reverse Plow Peristaltic Pump; SM = Straw Method (Tubing Gravity Drain); O = Other (Grab)
Nu CES: 1. The above do not constitute all of the Information required by Chapter 62-160, F.A.C.
2. Stabilization Criteria for range of variation of last three consecutive readings (see F S 2212. section 3)
pH: + 0.2 units Temperature: + 0.2 C Specific Conductance: +5% Dissolved Oxygen: all readings < 20% saturation (see Table FS 2200-2); optionally, + 0.2 mg/L or + 10% (whichever is greater) Turbidity: all readings < 20 NTU; optionally + 5 NTU or + 10% (whichever Is greater)
Revision Date: February 12, 2009
GROUNDWATER SAMPLING LOG
SITE NAME: ECUA Water Distribution System (Countv-wide)
SITE LOCATION: Escambia Countv. Florida
WELL NO: A U CO J f t k
SAMPLE ID:
DATE: February 3 ,2010
PURGING DATA
WELL CASING
//
DIAMETER (inches): ' ^
TUBING DIAMETER (inches): NA
WELL SCREEN INTERVAL
DEPTH:
UNK
PUMPING WATER LEVEL (feet): UNK
PU RGE PUMP TYPE: Existing Pump
W ELL VOLUME PURGE: 1 W ELL VOLUME = (TOTAL WELL DEPTH - STATIC DEPTH TO WATER) X WELL CAPACITY
(only fill out if applicable)
,
= ( 2. 0 4
feet-
UNK
feet) X
gallons/foot =
gallons
EQUIPMENT VOLUME PURGE: 1 EQUIPMENT VOL. = PUMP VOLUME + (TUBING CAPACITY
TUBING LENGTH) + FLOW CELL VOLUME
(only fill out if applicable)
= gallons + (
gallons/foot X
feet) +
gallons =
gallons
PUM P DEPTH IN W ELL (feet): UNK
TIME (CST)
VOLUME PURGED (gallons)
CUMUL. VOLUME PURGED
(gallons)
FINAL PUMP DEPTH IN W ELL (feet): UNK
PURGE RATE (gpm)
ORP (mV)
pH (standard
units)
PURGING INITIATED AT:
TEMP. (C)
COND. (gS/cm)
PURGING ENDED AT:
DISSOLVED OXYGEN (mg/L)
TOTAL VOLUME PURGED (gallons):
TURBIDITY (NTUs)
COLOR (describe)
ODOR (describe)
Clear
None
Clear
None
Clear
None
J L s A rAp L e
V E L L CAPACITY (Gallons Per Foot): 0.75" = 0.02; 1" = 0.04; 1.25" = 0.06; 2" = 0.16; 3" =0.37; 4" = 0.65; 5" = 1.02; 6" = 1.47; 12" =5.88 TUBING INSIDE DIA. CA PA CIT Y (Gal./Ft ). 1/8" = 0.0008; 3/16" = 0.0014; 1/4" = 0.0026; 5/16" =0.004; 3/8" = 0.006; 1/2" = 0.010; 5/8" =0.016
PURGING EQUIPMENT CODES: B = Bailer; B P = Bladder Pump;
E S P = Electric Submersible Pump;
PP = Peristaltic Pump;
O = Other (Specify)
SAMPLING DATA
SAM PLED BY (PRINT) / AFFILIATION: David L. Anderson/CDM
SAMPLER(S) SIGNATURE(S):
SAMPLING INITIATED AT:
SAMPLING ENDED AT:
PUM P DEPTH IN W ELL (feet): UNK
FIELD DECONTAMINATION:
PUMP: No
TUBING MATERIAL CODE: NA
TUBING: NA
FIELD-FILTERED: No Filtration Equipment Type:
DUPLICATE:
NA
FILTER SIZE: No
NA
urn
SAMPLE CONTAINER SPECIFICATION
SAMPLE IDCODE
NA
# CONTAINERS
2
MATERIAL CODE
PE
VOLUME 1 lite r
SAMPLE PRESERVATION
PRESERVATIVE USED
None
TOTAL VOL ADDED IN FIELD (mL)
None
FINAL pH
NA
INTENDED ANALYSIS AND/OR
METHOD
PFOA, PFOS, &
SAMPLING EQUIPMENT
CODE
O-Grab
SAMPLE PUMP FLOW RATE
(mL per minute)
<100 mL
Fluorinated Cmps
by HPLC/MS.
REMARKS: NA - Not Applicable.
UNK - Unknown.
Was the well pumping (active) prior to sam pling-Yes or No.
MS/MSD sample collected - Yes or No. Collection Time:
Well has fluoride treatment - f is t a r No.
Photograph No.
2 .")
d n .rt1'
/^o
i-- y / 'sA-M.-nj--
MATERIAL CODES:
A G = Amber Glass; CG = Clear Glass; PE = Polyethylene; PP = Polypropylene; S = Silicone; T = Teflon; O = Other (Specify)
'' AMPLING EQUIPMENT CODES: A P P = After Peristaltic Pump;
B = Bailer; B P = Bladder Pump; ESP = Electric Submersible Pump;
RFPP = Reverse Flow Peristaltic Pump; SM = Straw Method (Tubing Gravity Drain); O = Other (Grab)
ivoTES: 1. The above do not constitute all of the Information required by Chapter 62-160, F.A.C.
2. S t a b il iz a t io n C r it e r ia f o r r a n g e o f v a r ia t io n o f l a s t t h r e e c o n s e c u t iv e r e a d in g s (s e e F S 2 2 1 2 , s e c t io n 3)
pH:+ 0 . 2 units Temperature: +0 .2 C Specific Conductance: +5% Dissolved Oxygen: all readings < 2 0 % saturation (see Table F S 2 2 0 0 -2 ); optionally, 0 .2 mg/L or + 10 % (whichever is greater) Turbidity: all readings < 2 0 NTU; optionally + 5 NTU or + 10 % (whichever is greater)
Revision Date: February 12, 2009
I W i l l i I LS v V W V " L T
GROUNDWATER SAMPLING LOG
p. 1 0 1
SITE NAME: ECUA Water Distribution System (County-wide)
SITE LOCATION: Escambia County, Florida
VELLNO:
SAM PLE ID:
DATE: February 3 ' 2010
PURGING DATA
W ELL CASING -7 TUBING
WELL SCREEN INTERVAL
I PUMPING WATER
PURGE PUMP TYPE:
DIAMETER (inches): J
DIAMETER (inches): NA
DEPTH:
UNK
| LEVEL (feet): UNK
Existing Pump
WELL VOLUME PURGE: 1 WELL VOLUME = (TOTAL W ELL DEPTH - STATIC DEPTH TO WATER) X W ELL CAPACITY
(only fill out if applicable)
= ( 2 .0 0
feet -
UNK
feet) X
gallons/foot =
gallons
EQUIPMENT VOLUME PURGE: 1 EQUIPMENT VOL. = PU M P VOLUM E + (TUBING CAPACITY X TUBING LENGTH) + FLOW CELL VOLUME
(only fill out if applicable)
= gallons + (
gallons/foot X
feet) +
gallons =
gallons
PU M P DEPTH IN W ELL (feet): UNK
TIME (CST)
VOLUME PURGED (gallons)
CUMUL. VOLUME PURGED (gallons)
1331
13 42.
FINAL PUM P DEPTH IN W ELL (feet): UNK
PURGING
.
INITIATED AT: 1 3 3 S
PURGE RATE (gpm)
ORP (mV)
36>s 3 Ly
I PH (standard
units)
TEMP. (C)
* fe. 8 - fe .
2 /- b o
4.1-80
a -l.n
COND. (pS/cm)
to to SI
PURGING ENDED AT: DISSOLVED OXYGEN
(mg/L)
? . 2 (j> .a 2
TOTAL VOLUME PURGED (gallons):
TURBIDITY (NTUs)
COLOR (describe)
ODOR (describe)
/
Clear
None
O
Clear
None
0
Clear
None
, ELL CAPACITY (Gallons Per Foot): 0.75" = 0.02; 1" = 0.04; 1.25" = 0.06; 2" = 0.16; 3" = 0.37; 4" =0.65; 5" = 1.02; 6" =1.47; 12" = 5.88 TUBING INSIDE DIA. CAPACITY (GalTFt.): 1/8" = 0.0006; 3/16" = 0.0014; 1/4" = 0.0026; 5/16" = 0.004; 3/8" = 0.006; 1/2" = 0.010; 5/8" = 0.016
PURGING EQUIPMENT CODES: B = Bailer;
/S A M PLE D B Y (PRINT) AFFILIATION:
David L. Anderson/CDM
BP = Bladder Pump;
ESP = Electric Submersible Pump;
PP Peristaltic Pump;
SAMPLING DATA
9AMPLER(S) SIGNATURE(S):
SAMPLING INITIATED AT: I J 7 T
O = Other (Specify)
SAMPLING ENDED AT:
PU M P DEPTH IN W ELL (feet): UNK
TUBING MATERIAL CODE: NA
FIELD-FILTERED: No
FILTER SIZE: NA
Filtration Equipment Type: NA
urn
FIELD DECONTAMINATION:
PUMP: No
TUBING: NA
DUPLICATE:
No
SAM PLE CONTAINER SPECIFICATION
SAMPLE ID CODE
NA
#
CONTAINERS
2
MATERIAL C00E
PE
VOLUME
1liter
SAMPLE PRESERVATION
PRESERVATIVE USED
None
TOTAL VOL ADDED IN FIELD (mL)
None
FINAL pH NA
INTENDED ANALYSIS AND/OR
METHOD
PFOA, PFOS, &
Fluorinated Cmps
SAMPLING EQUIPMENT
CODE
O-Grab
SAMPLE PUMP FLOW RATE
(mL per minute)
<100 mL
by HPLC/MS.
REMARKS: NA - Not Applicable.
UNK - Unknown.
W as the well pumping (active) prior to sampling ^Ye^ or No.
MS/MSD sample collected - Yes oi(^N^ Collection Time:
Well has fluoride treatment
or No.
Photograph No. CISprVcV\ 12.
c a t .-i i j MATERIAL CODES:
/>yf'. = =A G Amber Glass; CG Clear Glass;
=PE Polyethylene;
= = = =PP Polypropylene; S Silicone; T Teflon; O Other (Specify)
~\MPLING EQUIPMENT CODES:
A P P = After Peristaltic Pump;
B = Bailer; B P = Bladder Pump; E S P = Electric Submersible Pump;
RFPP = Reverse Flow Peristaltic Pump; SM = Straw Method (Tubing Gravity Drain); O = Other (Grab)
NitTES: 1. The abovedo n ot constituteall o f the information required by Chapter 62-160, F.A.C.
2. Stabilization Criteria for range of variation of last three consecutive readings (see F S 2212. section 3)
pH: + 0.2 units Temperature:+0.2 C Specific Conductance: +5% Dissolved Oxygen: all readings <20% saturation (see Table FS 2200-2); optionally, 0.2 mg/L or + 10% (whichever Is greater) Turbidity: all readings < 20 NTU; optionally + 5 NTU or + 10% (whichever is greater)
Revision Date: February 12, 2009
GROUNDWATER SAMPLING LOG
SITE NAME: ECUA Water Distribution System (Countv-wide)
SITE LOCATION: Escambia Countv. Florida
/VELLNO:
SAMPLE ID:
DATE: February ^ ,2010
PURGING DATA
WELL CASING
^ TUBING
WELL SCREEN INTERVAL
I PUMPING WATER
PURGE PUMP TYPE:
DIAMETER (inches): -> ^ DIAMETER (inches): NA
DEPTH:
UNK
I LEVEL (feet): UNK
Existing Pump
W ELL VOLUME PURGE: 1 W ELL VOLUME = (TOTAL WELL DEPTH - STATIC DEPTH TO WATER) X WELL CAPACITY
(only fill out if applicable)
=( 2 O O
feet -
UNK
feet) X
gallons/foot
gallons
EQUIPMENT VOLUM E PURGE: 1 EQUIPMENT VOL. = PUM P VOLUME + (TUBING CAPACITY
TUBING LENGTH) + FLOW CELL VOLUME
(only fill out if applicable)
= gallons + (
gallons/foot X
feet) +
gallons =
gallons
PUM P DEPTH IN W ELL (feet): UNK
TIME (CST)
VOLUME PURGED (gallons)
CUMUL. VOLUME PURGED (gallons)
13 r
13 S 3
l3S<o
FINAL PUMP DEPTH IN W ELL (feet): UNK
PURGE RATE (gpm)
ORP (mV)
pH (standard
units)
s '$ 4
rs i
PURGING
,? -
INITIATED AT: > 3 S S
TEMP. (C)
COND. (pS/cm)
2 c ..S >
(,4
PURGING ENDED AT:
DISSOLVED OXYGEN (mg/L)
-H
(IS (e
TOTAL VOLUME PURGED (gallons):
TURBIDITY COLOR
(NTUs)
(describe)
ODOR (describe)
Clear Clear Clear
None None None
/ELL CAPACITY (Gallons Per Foot): 0.75" = 0.02; 1" = 0.04; 1.25" = 0.06; 2" = 0.16; 3" = 0.37; 4" = 0.65; 5" = 1.02; 6" = 1.47; 12" = 5.88 TUBING INSIDE DIA. CAPACITY (QalTFt.): 1/8" = 0.0006; 3/16" =0.0014; 1/4" = 0.0026; 5/16" = 0.004; 3/8" = 0.006; 1/2" = 0.010; 5/8" =0.016
PURGING EQUIPMENT CODES: B = Bailer;
SAM PLED BY (PRINT) / AFFILIATION: David L. Anderson/CDM
BP = Bladder Pump;
ESP = Electric Submersible Pump;
PP = Peristaltic Pump;
SAMPLING DATA
SAMPLER(S) SIGNATURE(S):
SAMPLING INITIATED AT: I t y t 6
0 = Other (Specify)
SAMPLING ENDED AT:
PUM P DEPTH IN W ELL (feet): UNK
TUBING MATERIAL CODE: NA
FIELD-FILTERED: No
FILTER SIZE: NA
Filtration Equipment Type: NA
urn
FIELD DECONTAMINATION:
PUMP: No
TUBING: NA
DUPLICATE:
No
SAMPLE CONTAINER SPECIFICATION
SAMPLE ID CODE
NA
# CONTAINERS
2
MATERIAL CODE
PE
VOLUME I liter
SAMPLE PRESERVATION
PRESERVATIVE USED
None
TOTAL VOL ADDED IN FIELD (mL)
None
FINAL pH NA
INTENDED ANALYSIS AND/OR
METHOD
PFOA, PFOS, &
Fluorinated Cmps
SAMPLING EQUIPMENT
CODE
O-Grab
SAMPLE PUMP FLOW RATE
(mL per minute)
<100 mL
by HPLC/MS.
REMARKS: NA - Not Applicable.
UNK - Unknown.
Was the well pumping (active) prior to sampling ^ Yei) or No.
MS/MSD sample collected - Yes or (No) Collection Time:
Well has fluoride treatment -^7e^ or No.
Photograph No. c |
-2.
c a /v a /
/</ '
MATERIAL CODES:
A G = Amber Glass; C G = Clear Glass; PE = Polyethylene; PP = Polypropylene; S = Silicone; T =Teflon; O = Other (Specify)
SAM PLING EQUIPMENT CODES: A P P = After Peristaltic Pump;
B = Bailer; B P = Bladder Pump; E S P = Electric Submersible Pump;
RFPP = Reverse Flow Peristaltic Pump; SM = Straw Method (Tubing Gravity Drain); O = Other (Grab)
u o T E S : 1. The above do not constitute all of the information required by Chapter 62-160, F.A.C. 2. S t a b i l i z a t i o n C r i t e r i a f o r r a n g e o f v a r i a t i o n o f l a s t t h r e e c o n s e c u t i v e r e a d i n g s (s e e FS 2212, s e c t i o n 3)
pH: +0.2 units Temperature: 0.2 C Specific Conductance: +5% Dissolved Oxygen: all readings <20% saturation (see Table FS 2200-2); optionally, +0.2 mg/L or + 10% (whichever is greater) Turbidity: all readings < 20 NTU; optionally +5 NTU or + 10% (whichever is greater)
Revision Date: February 12, 2009
GROUNDWATER SAMPLING LOG
i SITE NAME; ECU A Water Distribution System (County-wide)
SITE LOCATION: Escambia County, Florida
.VELLNO: | / / / / A Q , UQ.
SAM PLE ID:
Ka k )
PURGING DATA
DATE: February 3 , 2010
WELL CASING
_
TUBING
WELL SCREEN INTERVAL
PUMPING WATER
PURGE PUMP TYPE:
DIAMETER (Inches): 3 O
DIAMETER (Inches): NA
DEPTH:
UNK
LEVEL (feet): UNK
Existing Pump
WELL VOLUME PURGE: 1 WELL VOLUME = (TOTAL W ELL DEPTH - STATIC DEPTH TO WATER) X W ELL CAPACITY
(only fill out if applicable)
= ( 2 3 2_
feet -
UNK
feet) X
gallons/foot =
aallons EQUIPMENT VOLUME PURGE: 1 EQUIPMENT VOL. =PU M P VOLUME +(TUBING CAPACITY X TUBING LENGTH) +FLOW CELL VOLUME
(only fill out If applicable)
= gallons +(
gallons/foot X
feet) +
gallons =
gallons
PU M P DEPTH IN W E LL (feet): UNK
TIME (CST)
VOLUME PURGED (gallons)
CUMUL. VOLUME PURGED (gallons)
/VO?
Hn
H/S
FINAL PUMP DEPTH IN W ELL (feet): UNK
PURGING
. , / PURGING
INITIATED AT: / V O * ENDED AT:
PURGE RATE (gpm)
ORP (mV)
nn
pH (standard
units)
XU
f'L i
<. (A
TEMP. (C)
Al- (,6
Al- U
COND. (gS/cm)
rS rt
DISSOLVED OXYGEN (mg/L)
/ I S
/ a ? /. ?o
TOTAL VOLUME PURGED (gallons):
TURBIDITY COLOR
(NTUs)
(describe)
ODOR (describe)
O
Clear
None
O
Clear
None
O
Clear
None
ELL CAPACITY (Gallons Per Foot): 0.75" = 0.02; 1" =0.04; 1.25" = 0.06; 2" = 0.16; 3" = 0.37; 4" =0.65; 6" =1.02; 6" = 1.47; 12" =5.88
TUBING INSIDE DIA. CAPACITY (GalVFt ): 1/8" = 0.0006: 3/16" =0.0014; 1/4" =0.0026; 5/16" = 0.004; 3/8" =0.006; 1/2" =0.010; 5/8" =0.016
PURGING EQUIPMENT CODES: B =Bailer; BP =Bladder Pump;
ESP =Electric Submersible Pump;
PP =Peristaltic Pump;
O =Other (Specify)
SAMPLING DATA
SA M PLED B Y (PRINT) / AFFILIATION: David L. Anderson/CDM
SAMPLER(S) SIGNATURE(S):
I SAMPLING | INITIATED AT: / V / 8
SAMPLING ENDED AT:
PU M P DEPTH IN W E LL (feet): UNK
FIELD DECONTAMINATION:
PUMP: No
TUBING MATERIAL CODE: NA
TUBING: NA
FIELD-FILTERED: No Filtration Equipment Type:
DUPLICATE:
NA
FILTER SIZE: No
NA
urn
SAM PLE CONTAINER SPECIFICATION
SAMPLE ID CODE
NA
It CONTAINERS
2
MATERIAL CODE PE
VOLUME I liter
SAMPLE PRESERVATION
PRESERVATIVE USED
None
TOTAL VOL ADDED IN FIELD (mL)
None
FINAL PH NA
INTENDED ANALYSIS AND/OR
METHOD
PFOA, PFOS, &
SAMPLING EQUIPMENT
CODE
O-Grab
SAMPLE PUMP FLOW RATE
(mL per minute)
<100 mL
Fluorinated Cmps
by HPLC/MS.
REMARKS: NA - Not Applicable.
UNK - Unknown.
W as the well pumping (active) prior to sampling^Yes^or No.
MS/MSD sample collected - Yes or (N O C o lle ctio n Time:
Well has fluoride treatment -^Yes)cr No.
Photograph No. / b C S
Z2.
C A .rri\ j
/cc '
MATERIAL CODES:
A G = Amber Glass; CG = Clear Glass; PE = Polyethylene; PP = Polypropylene; S = Silicone; T =Teflon; O = Other (Specify)
SAM PLING EQUIPM ENT CODES: A P P = After Peristaltic Pump;
B = Bailer; B P = Bladder Pump; E S P = Electric Submersible Pump;
RFPP = Reverse Flow Peristaltic Pump; SM = Straw Method (Tubing Gravity Drain); O = Other (Grab)
.. _ i'ES: 1. The above do not constitute all of the information required by Chapter 62-160, F.A.C. 2. S t a b i l i z a t i o n C r i t e r i a f o r r a n g e o f v a r i a t i o n o f l a s t t h r e e c o n s e c u t i v e r e a d i n g s (s e e FS 2212. s e c t i o n 3)
pH: + 0.2 units Temperature: +0.2 C Specific Conductance: +5% Dissolved Oxygen: all readings <20% saturation (see Table FS 2200-2); optionally, + 0.2 mg/Lor + 10% (whichever is greater) Turbidity: all readings <20 NTU; optionally + 5 NTU or + 10% (whichever is greater)
Revision Date: February 12, 2009
GROUNDWATER SAMPLING LOG
SITE NAME: ECUA Water Distribution System (Countv-wide)
NELL NO: [/ f / / A Q , (vJ
SAM PLE ID:
SITE LOCATION: Escambia Countv. Florida
-f,
DATE: February 3
, 2010
PURGING DATA
WELL CASING
-j
DIAMETER (inches):
TUBING DIAMETER (inches): NA
WELL SCREEN INTERVAL
DEPTH:
UNK
PUMPING WATER LEVEL (feet): UNK
PURGE PUMP TYPE: Existing Pump
W ELL VOLUME PURGE: 1 W ELL VOLUME = (TOTAL WELL DEPTH - STATIC DEPTH TO WATER) X WELL CAPACITY
(only fill out If applicable)
= ( 2 . 3 2.
feet-
UNK
feet) X
gallons/foot =
gallons
EQUIPMENT VOLUME PURGE: 1 EQUIPMENT VOL. = PUM P VOLUME + (TUBING CAPACITY
TUBING LENGTH) + FLOW CELL VOLUME
(only fill out If applicable)
= gallons + (
gallons/foot X
feet) +
gallons =
gallons
PU M P DEPTH IN W ELL (feet): UNK
TIME (CST)
VOLUME PURGED (gallons)
CUMUL. VOLUME PURGED (gallons)
/^ 2 o
AV23
/ V - 7 Ip
FINAL PUMP DEPTH IN W ELL (feet): UNK
PURGING
.
INITIATED AT: r V 0 ( ?
PURGE RATE
(9pm)
ORP (mV)
6Y8 U V<o
pH (standard
units)
TEMP. (C)
2 o .? % 2 0 -? $
COND. (pS/cm)
/8 o
I I
?/*
/g o
PURGING ENDED AT:
DISSOLVED OXYGEN (mg/L)
I I (e
/ p y /. o l
TOTAL VOLUME PURGED (gallons):
TURBIDITY (NTUs)
COLOR (describe)
ODOR (describe)
Clear Clear Clear
None None None
E L L CAPACITY (Gallons Per Foot): 0.75'' = 0.02; 1" = d.04; 1.25" = 0.06; 2" = 0.16; 3" = 0.37; 4"=0.65; 5" = 1.02; 6" = 1.47; 12" =5.88 TUBING INSIDE DIA. CA PA CITY (QaUFt): 1/8" = 0.0006; 3/16" = 0.0014; 1/4" = 0.0026; 5/16" = 0.004; 3/8" = 0.006; 1/2"=0.010; S/8* = 0.016
PURGING EQUIPMENT CODES: B = Bailer; B P = Bladder Pump;
E S P = Electric Submersible Pump;
PP = Peristaltic Pump;
O = Other (Specify)
SAM PLED BY (PRINT) / AFFILIATION: David L. Anderson/CDM
SAMPLING DATA
SAMPLER(S)SIGNATURE{S):
SAMPLING
,
INITIATED AT: ' 7 2 6
SAMPLING ENDED AT:
PU M P DEPTH IN W ELL (feet): UNK FIELD DECONTAMINATION: PUMP: No
TUBING MATERIAL CODE: NA
TUBING: NA
FIELD-FILTERED: No Filtration Equipment Type:
DUPLICATE:
NA
FILTER SIZE: No
NA
urn
SAMPLE CONTAINER SPECIFICATION
SAMPLE ID CODE
NA
# CONTAINERS
2
MATERIAL CODE
PE
VOLUME i liter
SAMPLE PRESERVATION
PRESERVATIVE USED
None
TOTAL VOL ADDED IN FIELD (mL)
None
FINAL PH NA
INTENDED ANALYSIS AND/OR
METHOD
PFOA, PFOS, &
SAMPLING EQUIPMENT
CODE
O-Grab
SAMPLE PUMP FLOW RATE
(mL per minute)
<100 mL
Fluorinated Cm ps
by HPLC/MS.
REMARKS: NA - Not Applicable.
UNK - Unknown.
W as the well pumping (active) prior to sampling rYe^> or No.
MS/MSD sample collected - Yes or C 5 g 3 Collection Time:
Well has fluoride treatment
No.
Photograph No. f t ( i? h 4 - c k 2."^
CAr-ny W+'h / c '-
MATERIAL CODES:
A G = Amber Glass; C G = Clear Glass; P E = Polyethylene; P P = Polypropylene; S = Silicone; T = Teflon; O = Other (Specify)
RAMPLING EQUIPMENT CODES: A P P = After Peristaltic Pump;
B = Bailer; B P = Bladder Pump; E SP = Electric Submersible Pump;
RFPP = Reverse Flow Peristaltic Pump; SM = Straw Method (Tubing Gravity Drain); O = Other (Grab)
i.^ T E S : 1. The above do not constitute all of the information required by Chapter 62-160, F.A.C. 2. STABILIZATION C R IT E R IA FO R R A N G E O F VARIATION O F L A S T T H R E E C O N S E C U T IV E R E A D IN G S (S E E FS 2212. SECTIO N 3)
pH: +0.2 units Temperature: 0.2 C Specific Conductance: 5% Dissolved Oxygen: all readings <20% saturation (see Table FS 2200-2); optionally, +0.2 mg/L or + 10% (whichever is greater) Turbidity: all readings <20 NTU; optionally + 5 NTU or + 10% (whichever is greater)
Revision Date: February 12, 2009
GROUNDWATER SAMPLING LOG
SITE NAME: ECU A Water Distribution System (County-wide)
SITE LOCATION: Escambia County, Florida
W ELL NO: j ^ e / C e
SAM PLE ID: ^
DATE: February J ,2010
PURGING DATA
W ELL CASING ~ TUBING
WELL SCREEN INTERVAL
PUMPING WATER
PURGE PUMP TYPE:
DIAMETER (Inches):
DIAMETER (inches): NA
DEPTH:
UNK
LEVEL (feet): UNK
Existing Pump
WELL VOLUME PURGE: 1 WELL VOLUME = (TOTAL W ELL DEPTH - STATIC DEPTH TO WATER) X W ELL CAPACITY
(only fill out if applicable)
= ( 2-V O
feet-
UNK
feet) X
gallons/foot =
gallons
EQUIPMENT VOLUME PURGE: 1 EQUIPMENT VOL. = PU M P VOLUME +(TUBING CAPACITY X TUBING LENGTH) + FLOW CELL VOLUME
(only fill out if applicable)
= gallons + (
gallons/foot X
feet) +
gallons =
gallons
PU M P DEPTH IN W ELL (feet): UNK
TIME (CST)
VOLUME PURGED (gallons)
CUMUL. VOLUME PURGED (gallons)
iq ss
W St /5c f
FINAL PU M P DEPTH IN W ELL (feet): UNK
PURGE RATE (gpm)
ORP (mV)
V -20 1/2.3
pH (standard
units)
r .3 7
S -.2- ? s '. 2-3-
PURGING INITIATED AT: / V S Z
PURGING ENDED AT:
TEMP. (C)
COND. (pS/cm)
DISSOLVED OXYGEN (mg/L)
2 2 - ILj 2 2 . IH
7-4
S~.fl
1*
TOTAL VOLUME PURGED (gallons):
TURBIDITY (NTUs)
o
COLOR (describe)
Clear Clear Clear
ODOR (describe)
None None None
ELL CAPACITY (Gallons Per Foot): 0.75" =0.02; 1" =0.04; 1.25" = 0.06; 2" =0.16; 3" =0.37; 4" =0.65; 5" = 1.02; 6" =1.47; 12" =5.88 TUBING INSIDE DIA. CAPACITY (Gal./Ft.): 1/8" =0.0006; 3/16" = 0.0014; 1/4" = 0.0026; 5/16" =0.004; 3/8" =0.006; 1/2" =0.010; SIB"= 0.016
PURGING EQUIPMENT CODES: B = Bailer;
SA M PLED B Y (PRINT) / AFFILIATION: David L. Anderson/CDM
BP =Bladder Pump;
ESP =Electric Submersible Pump;
PP = Peristaltic Pump;
SAMPLING DATA
SAMPLER(S)SIGNATURE(S):
SAMPLING
.
INITIATED AT: I S (ij
O =Other (Specify)
SAMPLING ENDED AT:
PU M P DEPTH IN W ELL (feet): UNK FIELD DECONTAMINATION: PUMP: No
TUBING MATERIAL CODE: NA
TUBING: NA
FIELD-FILTERED: No Filtration Equipment Type:
DUPLICATE:
NA
FILTER SIZE: No
NA
urn
SAM PLE CONTAINER SPECIFICATION
SAMPLE ID CODE
NA
#
CONTAINERS
2
MATERIAL CODE
PE
VOLUME
1liter
SAMPLE PRESERVATION
PRESERVATIVE USED
None
TOTAL VOL ADDED IN FIELD (mL)
None
FINAL pH NA
INTENDED ANALYSIS AND/OR
METHOD
PFOA, PFOS, &
Fluorlnated Cmps
SAMPLING EQUIPMENT
CODE
O-Grab
SAMPLE PUMP FLOW RATE
(mL per minute)
<100 mL
by HPLC/MS.
REMARKS: NA - Not Applicable.
UNK - Unknown.
Was the well pumping (active) prior to sampling ^ Y e i> o r No.
MS/MSD sample collected - Yes af^Ng) Collection Time:
Well has fluoride treatm ent-as)or No.
C ftr.-n y
/3 fc\
Photograph No. / 2- C 8 e 4 c V \ 2.")
MATERIAL CODES:
A G = Amber Glass; C G = Clear Glass; PE = Polyethylene; P P = Polypropylene; S = Silicone; T =Teflon; 0 = Other (Specify)
I SAM PLING EQUIPM ENT CODES: APP = After Peristaltic Pump;
B = Bailer; B P = Bladder Pump; E S P = Electric Submersible Pump;
RFPP = Reverse Row Peristaltic Pump; SM = Straw Method (Tubing Gravity Drain); O = Other (Grab)
.. - (ES: 1. The above do not constituteall of the information required by Chapter 62-160, F.A.C.
2. Stabilization Criteria for range of variation of last three consecutive readings (see F S 2212. section 3)
pH: + 0.2 units Temperature: + 0.2 C Specific Conductance: +5% Dissolved Oxygen: all readings < 20% saturation (see Table FS 2200-2); optionally, + 0.2 m g/Lor + 10% (whichever is greater) Turbidity: all readings < 20 NTU; optionally + 5 NTU or + 10% (whichever is greater)
Revision Date; February 12, 2009
GROUNDWATER SAMPLING LOG
SITE NAME: ECUA Water Distribution System (Countv-wide)
SITE LOCATION: Escambia County, Florida
W ELL NO:
SAM PLE ID:
DATE: February
, 2010
PURGING DATA
WELL CASING
TUBING
WELL SCREEN INTERVAL
PUMPING WATER
PURGE PUMP TYPE:
DIAMETER (inches): 3
DIAMETER (inches): NA
DEPTH:
UNK
LEVEL (feet): UNK
Existing Pump
WELL VOLUME PURGE: (only fill out if applicable)
gallons
1W ELL VOLUME = (TOTAL W ELL DEPTH -
= ( 2.V 0
feet -
STATIC DEPTH TO WATER) X WELL CAPACITY
UNK
feat) X
gallons/foot =
EQUIPMENT VOLUM E PURGE: 1 EQUIPMENT VOL. = PUM P VOLUME + (TUBING CAPACITY X
(only fill out if applicable)
= gallons + (
gallons/foot X
TUBING LENGTH) + FLOW CELL VOLUME
feet) +
gallons =
gallons
PUM P DEPTH IN W ELL (feet): UNK
TIME (CST)
VOLUME PURGED (gallons)
CUMUL. VOLUME PURGED (gallons)
/r* *
/ r /o
/r/3
FINAL PU M P DEPTH IN W ELL (feet): UNK
PURGING
PURGING
INITIATED AT: ^ S 2 . ENDED AT;
PURGE RATE (gpm)
ORP (mV)
pH (standard
units)
TEMP. (C)
COND. (nS/cm)
DISSOLVED OXYGEN (mg/L)
ml
-22-02.
S', fev
mi
? ./g in
22.-o 1 22. 0 3
**
r. U S'. U S
TOTAL VOLUME PURGED (gallons):
TURBIDITY (NTUs)
COLOR (describe)
ODOR (describe)
o
Clear
None
Clear
None
Clear
None
,E L L CAPA CIT Y (Gallons Per Foot): 0.75" = 0.02; 1" = 0.04; 1.25" = 0.06; 2" = 0.16; 3" = 0.37; 4" = 0.65; 5" = 1.02; 6" = 1.47; 12" = 5.88 TUBING INSIDE DIA. CAPACITY (Gal/Ft.): 1/8 =0.0006; 3/16" = 0.0014; 1/4" = 0.0026; 5/16" =0.004; 3/8" = 0.006; 1/2" = 0.010; 5/8" = 0.016
PURGING EQUIPMENT CODES: B = Bailer; B P = Bladder Pump;
E S P = Electric Submersible Pump;
PP = Peristaltic Pump;
O =Other (Specify)
SAMPLING DATA
SAM PLED BY (PRINT) /AFFILIATION: David L. Anderson/CDM
^AMPLER(S) SIGNATURE(S):
SAMPLING
.^ . i
INITIATED AT: / b /
SAMPLING ENDED AT:
PU M P DEPTH IN W ELL (feet): UNK FIELD DECONTAMINATION: PUMP: No
TUBING MATERIAL CODE: NA
TUBING; NA
FIELD-FILTERED: No Filtration Equipment Type:
DUPLICATE:
NA
FILTER SIZE: No
NA
urn
SAMPLE CONTAINER SPECIFICATION
SAMPLE ID CODE
NA
#
CONTAINERS
2
MATERIAL CODE
PE
VOLUME
1liter
SAMPLE PRESERVATION
PRESERVATIVE USED None
TOTAL VOL ADDED IN FIELD (mL)
None
FINAL
PH___ NA
INTENDED ANALYSIS AND/OR
METHOD
PFOA, PFOS, &
Fluorlnated Cmps
SAMPLING EQUIPMENT
CODE
O-Grab
SAMPLE PUMP FLOW RATE
(mL per minute)
<100 mL
by HPLC/MS.
REMARKS: NA - Not Applicable.
UNK - Unknown.
Was the well pumping (active) prior to sampling^Ye^) or No.
MS/MSD sample co llected -Y e s o r/ 'N ip C o l lection Time:
Well has fluoride treatment - { S to r No.
CA rn\f
3 la .
Photograph No. 13 C B f v V c K -2_')
MATERIAL CODES:
AG =Amber Glass; CG =Clear Glass; PE =Polyethylene; PP =Polypropylene; S = Silicone; T =Teflon; O =Other (Specify)
SAM PLING EQUIPMENT CODES: A P P = After Peristaltic Pump;
B = Bailer; B P = Bladder Pump; E S P = Electric Submersible Pump;
R FPP = Reverse Flow Peristaltic Pump; SM = Straw Method (Tubing Gravity Drain); 0 = Other (Grab)
i.^ T E S : 1. The above do not constitute all of the Information required by Chapter 62-160, F.A.C. 2. S t a b il iz a t io n C r it e r ia f o r r a n g e o f v a r i a t i o n o f l a s t t h r e e c o n s e c u t i v e r e a d i n g s (s e e F S 2 2 1 2 , s e c t i o n 3)
pH: + 0.2 units Temperature: + 0.2 C Specific Conductance: +5% Dissolved Oxygen: all readings <20% saturation (see Table FS 2200-2); optionally, +0.2 mg/L or + 10% (whichever is greater) Turbidity: all readings < 20 NTU; optionally 5 NTU or + 10% (whichever is greater)
Revision Date: February 12, 2009
GROUNDWATER SAMPLING LOG
SITE NAME: ECUA Water Distribution System (County-wide)
SITE LOCATION: Escambia County, Florida
W ELL NO: / ) j - J o . V
SAM PLE ID:
DATE: February 3 2010
PURGING DATA
WELL CASING
, q TUBING
WELL SCREEN INTERVAL
PUMPING WATER
DIAMETER (inches): ' D
DIAMETER (inches): NA
DEPTH:
UNK
LEVEL (feet): UNK
W ELL VOLUME PURGE: 1 W ELL VOLUME = (TOTAL W ELL DEPTH - STATIC DEPTH TO WATER) X WELL CAPACITY
(only fill out if applicable)
= ( JZ8 0
,e0t -
UNK
feet) X
PU RGE PUMP TYPE: Existing Pump
gallo ns/foot =
EQUIPMENT VOLUME PURGE: 1 EQUIPMENT VOL. = PUMP VOLUME + (TUBING CAPACITY X
(only fill out if applicable)
gallons + (
galtons/foot X
PUM P DEPTH IN W E LL (feet): UNK
TIME (CST)
VOLUME PURGED (gallons)
CUMUL. VOLUME PURGED (gallons)
FINAL PUMP DEPTH IN W ELL (feet): UNK
PURGE RATE
(gpm)
ORP (mV)
pH (standard
units)
PURGING INITIATED AT:
TEMP. (C)
COND. (gS/cm)
TUBING LENGTH) + FLOW CELL VOLUME
feet)+
PURGING ENDED AT:
gallons =
gallons
TOTAL VOLUME PU RGED (gallons):
DISSOLVED OXYGEN (mg/L)
TURBIDITY (NTUs)
COLOR (describe)
ODOR (describe)
Clear
None
Clear
None
Clear
None
/V c
T a N \ PI<Z.
ELL CAPACITY (Gallons Per Foot): 0.75" = 0.02; 1" = 0.04; 1.25'' = 0.06; 2" = 0.16; 3" = 0.37; 4" = 0.65; 5" = 1.02; 6*' = 1.47; 12" = 5.88 TUBING INSIDE DIA. CAPACITY (Gal./Ft.): 1/8* = 0.0006; 3/16" = 0.0014; 1/4" = 0.0026; 5/16" = 0.004; 3/8" = 0.006; 1/2" = 0.010; 5/8" = 0.016
PURGING EQUIPMENT CODES: B = Bailer; BP = Bladder Pump;
ESP = Electric Submersible Pump;
PP = Peristaltic Pump; O = Other (Specify)
SAMPLING DATA
SAM PLED BY (PRINT) /AFFILIATION: David L. Anderson/CDM
SAMPLER(S) SIGNATURE(S):
SAMPLING INITIATED AT:
SAMPLING ENDED AT:
PU M P DEPTH IN W ELL (feet): UNK
TUBING MATERIAL CODE: NA
FIELD-FILTERED: No
FILTER SIZE: NA urn
Filtration Equipment Type: NA
FIELD DECONTAMINATION:
PUMP: No
TUBING: NA
DUPLICATE:
No
SAMPLE CONTAINER SPECIFICATION
SAMPLE IDCODE
NA
#
CONTAINERS
2
MATERIAL CODE
PE
VOLUME I liter
SAMPLE PRESERVATION
PRESERVATIVE USED
None
TOTAL VOL ADDED IN FIELD (mL)
None
FINAL PH NA
INTENDED ANALYSIS AND/OR
METHOD
PFOA, PFOS, &
Fluorinated Cmps
SAMPLING EQUIPMENT
CODE
O-Grab
SAMPLE PUMP FLOW RATE
(mL per minute)
<100 mL
by HPLC/MS.
N A -N c ri Applicable. K
W as the well pumping (active) prior to sam pling-Y es or No.
UNK-Unknown.
D-
l~i\as
o. r\
C A -r-rn * d.r+Vt / o ' .
MS/MSD sample collected - Yes or No. Collection Time:
f
Well has fluoride treatment - Yes or No.
Photograph No. ^4/ C * V t.V \ 2 .
UlO-ll U t MATERIAL CODES:
i'A A C + C o . -P<v 3 - V Y AG =Amber Glass; CG =Clear Glass;
A c 4PE =Polyethylene;
o r A'o fu4vrt<J. OS'<3. oiL + W , f r iQ . PP =Polypropylene; S = Silicone; T =Teflon; O =Other (Specify)
SAMPLING EQUIPMENT CODES: APP = After Peristaltic Pump;
B = Bailer; BP = Bladder Pump; ESP = Electric Submersible Pump;
RFPP =Reverse Flow Peristaltic Pump; SM = Straw Method (Tubing Gravity Drain); O = Other (Grab)
CES: 1. The above do not constitute all of the information required by Chapter 62-160, F.A.C.
2. S T A B I L I Z A T I O N C R I T E R I A F O R R A N G E O F V A R IA T IO N O F L A S T T H R E E C O N S E C U T I V E R E A D I N G S ( S E E F S 2212. S E C T IO N 3)
pH: + 0.2 units Temperature: + 0.2 C Specific Conductance: +5% Dissolved Oxygen: all readings < 20% saturation (see Table FS 2200-2); optionally, + 0.2 mg/L or + 10% (whichever is greater) Turbidity: all readings < 20 NTU; optionally + 5 NTU or + 10% (whichever is greater)
Revision Date: February 12, 2009
GROUNDWATER SAMPLING LOG
SITE NAME: ECUA Water Distribution System (Countv-wide)
SITE LOCATION: Escambia County, Florida
W ELL NO: ^
y
SAM PLE ID:
DATE: February "R ,2010
PURGING DATA
W ELL CASING
, TUBING
WELL SCREEN INTERVAL
PUMPING WATER
PURGE PUMP TYPE:
DIAMETER (inches): *- & DIAMETER (inches): NA
DEPTH:
UNK
LEVEL (feet): UNK
Existing Pump
W ELL VOLUME PURGE: 1 W ELL VOLUME = (TOTAL W ELL DEPTH - STATIC DEPTH TO WATER) X WELL CAPACITY
(only fill out if applicable)
,
gallons
=( 4 0 1
feet-
UNK
feet) X
gallons/foot =
EQUIPMENT VOLUME PURGE: 1 EQUIPMENT VOL. = PU M P VOLUME + (TUBING CAPACITY (only fill out If applicable)
TUBING LENGTH) + FLOW CELL VOLUME
= gallons + (
gallons/foot X
feet) +
gallons =
gallons
PU M P DEPTH IN W ELL (feet): UNK
TIME (CST)
VOLUME PURGED (gallons)
CUMUL. VOLUME PURGED (gallons)
FINAL PUMP DEPTH IN W ELL (feet): UNK
PURGE RATE (gpm)
ORP (mV)
pH (standard
units)
PURGING INITIATED AT:
TEMP. (C)
COND. (pS/cm)
PURGING ENDED AT:
DISSOLVED OXYGEN (mg/L)
TOTAL VOLUME PURGED (gallons):
TURBIDITY (NTUs)
COLOR (describe)
ODOR (describe)
Clear
None
Clear
None
yVc> S A l ^ p L Z r
Clear
None
/ELL CAPACITY (Gallons Per Foot): 0.75" = 0.02; 1'' = 0.04; 1.25" = 0.06; 2" = 0.16; 3" = 0.37; 4" = 0.65; 5" =1.02; 6" = 1.47; 12" = 5.88 TUBING INSIDE DIA. CAPACITY (Gal./Ft.): 1/8" = 0.0006: 3/16" = 0.0014; 1/4" = 0.0026; 5/16" = 0.004: 3/8" =0.006; 1/2" = 0.010; 5/8" = 0.016
PURGING EQUIPMENT CODES: B = Bailer;
SAM PLED BY (PRINT) /AFFILIATION:
David L. Anderson/CDM
BP = Bladder Pump;
ESP = Electric Submersible Pump;
PP a Peristaltic Pump;
SAMPLING DATA
SAMPLER(S) SIGNATURE(S):
SAMPLING INITIATED AT:
O = Other (Specify)
SAMPLING ENDED AT:
PU M P DEPTH IN W ELL (feet): UNK
TUBING MATERIAL CODE: NA
FIELD-FILTERED: No
FILTER SIZE: NA
Filtration Equipment Type: NA
urn
FIELD DECONTAMINATION:
PUMP: No
TUBING: NA
DUPLICATE:
No
SAMPLE CONTAINER SPECIFICATION
SAMPLE ID CODE
#
CONTAINERS
MATERIAL CODE
VOLUME
NA 2
P E 1liter
SAMPLE PRESERVATION
PRESERVATIVE USED
None
TOTAL VOL ADDED IN FIELD (mL)
None
FINAL
PH NA
INTENDED ANALYSIS AND/OR
METHOD
PFOA, PFOS, &
Fluorlnated Cmps
SAMPLING EQUIPMENT
CODE
O-Grab
SAMPLE PUMP FLOW RATE
(mL per minute)
<100 mL
by HPLC/MS.
REMARKS: NA - Not Applicable.
UNK - Unknown.
Was the well pumping (active) prior to sampling - Yes or No.
MS/MSD sample collected - Yes or No. Collection Time:
Well has fluoride treatment -<Yes)or No.
T k < * J'i'A- W A T
TAj ft c>
MATERIAL CODES:
AG =Amber Glass; CG =Clear Glass;
Photograph No. 1S' C.dA<=V\-2.")
r^-l\ ftb 1i'-fi4A-''*r\. /b t i
C A jV n ^
PE =Polyethylene; PP =Polypropylene; S = Silicone; T =Teflon;
2 / t> .
O =Other (Specify)
SAMPLING EQUIPMENT COOES: APP = After Peristaltic Pump;
B = Bailer; BP = Bladder Pump; ESP = Electric Submersible Pump;
RFPP = Reverse Flow Peristaltic Pump; SM = Straw Method (Tubing Gravity Drain); O = Other (Grab)
...TES: 1. The above do not constituteall of the information required by Chapter 62-160, F.A.C.
2. STABILIZATIO N C R IT E R IA FO R RANGE O F VARIATION O F LA S T TH R EE CO N SECU TIV E READ IN G S (S E E F S 2 2 1 2 , SECTIO N 3)
pH: +0 .2 units Temperature: +0 .2 C Specific Conductance: +5% Dissolved Oxygen: all readings < 2 0 % saturation (see Table FS 2 2 0 0 -2 ); optionally, +0 .2 mg/L or +1 0 % (whichever is greater) Turbidity: all readings <2 0 NTU; optionally +5NTU or +1 0 % (whichever is greater)
Revision Date: February 12, 2009
GROUNDWATER SAMPLING LOG
SITE NAME: ECUA Water Distribution System (County-wide)
AWELL NO: L F --
SAM PLE ID:
SITE LOCATION: Escambia County, Florida
JDATE: February
,2010
PURGING DATA
WELL CASING DIAMETER (inches):
3o
TUBING DIAMETER (inches): NA
WELL SCREEN INTERVAL
DEPTH:
UNK
PUMPING WATER LEVEL (feet): UNK
PURGE PUMP TYPE: Existing Pump
W ELL VOLUME PURGE: 1 W ELL VOLUME = (TOTAL WELL DEPTH - STATIC DEPTH TO WATER) X WELL CAPACITY
(only fill out if applicable)
_ .,, =( 3 V g
feet-
UNK
feet) X
gallons/foot =
gallons
EQUIPMENT VO LU M E PURGE: 1 EQUIPMENT VOL. = PU M P VOLUME + (TUBING CAPACITY X TUBING LENGTH) + FLOW CELL VOLUME
(only fill out if applicable)
= gallons + (
gallons/foot X
feet) +
gallons =
gallons
PU M P DEPTH IN W ELL (feet): UNK
TIME (CST)
VOLUME PURGED (gallons)
CUMUL. VOLUME PURGED (gallons)
FINAL PUMP DEPTH IN W ELL (feet): UNK
PURGE RATE (gpm)
ORP (mV)
pH (standard
units)
PURGING INITIATED AT:
TEMP. (C)
COND. (pS/cm)
PURGING ENDED AT:
DISSOLVED OXYGEN (mg/L)
TOTAL VOLUME PURGED (gallons):
TURBIDITY (NTUs)
COLOR (describe)
Clear
ODOR (describe)
None
Clear
None
S f\ ya P i . r
Clear
None
ELL CAPACITY (Gallons Per Foot): 0.75" = 0.02; 1" = 0.04; 1.25" = 0.06; 2" = 0.16; 3" = 0.37; 4" = 0.65; 5" =1.02; 6" =1.47; 12" = 5.88
TUBING INSIDE DIA. CAPACITY (Gal./Ft.): 1/8" = 0.0006; 3/16" = 0.0014; 1/4* = 0.0026; 5/16" =0.004; 3/8" = 0.006;
1/2" = 0.010; 5/8" =0.016
PURGING EQUIPMENT CODES: B = Bailer;
SA M PLED B Y (PRINT) / AFFILIATION: David L. Anderson/CDM
BP = Bladder Pump;
ESP = Electric Submersible Pump;
PP = Peristaltic Pump;
SAMPLING DATA
SAMPLER(S) SIGNATURE(S);
SAMPLING INITIATED AT:
O = Other (Specify)
SAMPLING ENDED AT;
PU M P DEPTH IN W ELL (feet): UNK
TUBING MATERIAL CODE; NA
FIELD-FILTERED: No
FILTER SIZE: NA
Filtration Equipment Type: NA
urn
FIELD DECONTAMINATION:
PUMP: No
TUBING: NA
DUPLICATE:
No
SAMPLE CONTAINER SPECIFICATION
SAMPLE ID CODE
NA
# CONTAINERS
2
MATERIAL CODE PE
VOLUME I liter
SAMPLE PRESERVATION
PRESERVATIVE USED
None
TOTAL VOL ADDED IN FIELD (mL)
None
FINAL
PH NA
INTENDED ANALYSIS AND/OR
METHOD
PFOA, PFOS, &
SAMPLING EQUIPMENT
CODE
O-Grab
SAMPLE PUMP FLOW RATE
(mL per minute)
<100 mL
Fluorinated Cmps
by HPLC/MS.
REMARKS: N A - N o t Applicable.
UNK-Unknown.
W as the well pumping (active) prior to sampling - Yes or No.
MS/MSD sample collected - Yes or No. Collection Time:
Well has fluoride treatment -CYeskir No.
Photograph No. / ! o - / 8 (_B a A-c Y\ 2 " )
^ \( i,'n 4 i-n A r'C S , A* po\*a<tr c A r . ' n y d i'+ ^ 2 . / S' .
MATERIAL CODES:
A G =Amber Glass; C G = Clear Glass; PE = Polyethylene; PP = Polypropylene; S = Silicone; T =Teflon; O = Other (Specify)
SAM PLIN G EQUIPMENT CODES: A PP = After Peristaltic Pump;
B = Bailer; B P = Bladder Pump; E S P = Electric Submersible Pump;
R FPP = Reverse Flow Peristaltic Pump; SM = Straw Method (Tubing Gravity Drain); O = Other (Grab)
wTES: 1. The above do not constitute all of the information required by Chapter 62-160, F.A.C.
2. Stabilization Criteria for range of variation of last three consecutive readings (see F S 2212. section 3)
pH: 0.2 units Temperature: + 0.2 C Specific Conductance: + 5% Dissolved Oxygen: all readings < 20% saturation (see Table FS 2200-2); optionally, + 0.2 mg/L or + 10% (whichever is greater) Turbidity: all readings < 20 NTU; optionally + 5 NTU or + 10% (whichever is greater)
Revision Date: February 12, 2009
Form FD9000-8 CALIBRATION LOG (FDEP SOP FT 1000-FT 1500, FD 1000-FD 4000) -11 1 * 0 5
^5Project/Ste:: 3 Pi
JB oJl -
u s ^ - i l r _________
Date: F * ir . / - 3 , <2c>/o
Meter#
S 'S 'b ( & / ( ? ' )
Tem perature (Quarterly)
F o r D a te o f L a s t T e m p e ra tu re V e rific a tio n s e e
in lo o b o o k
D .is s o l,,v e d. O_ xy g en D^E P1S5QO0P .in.i.t.ia.ls
_D a t.e
T im e
cPhraorbgee
PGr oa jbne
CAL CAL CAL CAL
ICV ICV ICVCCV^ ICV C C V
-3 /o
ofcs-o O f OO
mg/L
Tem p c
% DO
Saturation mg/L
(from chart)
Pass or Fail
A c c e p ta n c e Criteria:+/-0.3mg/l
7 ?5
CAL ICV C CV C AL ICV C C V CAL ICV C C V CAL ICV C C V
pH
DEP SOP FT 1100
Initials
Date
CAL CAL CAL CAL CAL CAL CAL CAL CAL
ICV c v l ICV C C V I ICV C C V ICV C C V ICV C C V ICV C C V ICV C C V ICV C C V ICV JIcCgCy J
bJJb-
M aintenance: W eekly pH Slope:
Notes:
j; - / -fa Z -l-h * 2 ,-7 '*'= * 2-(-/<=>
X -?-*>
T im e
Standard SU
Exp. Date
4 T" /to
Lot#
e>T :c o
/e
/ Specific Conductance Probe Cleaned? Y e s No
P P P P
Bottle #
Slope
Reading SU
Pass or Fail
A c c e p t a n c e Criteria: +/- 0.2 S U
y- M
7 .o g /6./
j.y e
?. at / o .o e
Ct>
jy .o i
L -T ?
Cel)
Dissolved Oxygen Membrane Changed: Y e s Q ^
Perform only in Calibrate Mode:
Perform only in Run Mode: Perform only in Run Mode:
C A L - Calibrate ICV - Initial Calibration Verification C C V - Continuing Calibration Verification
Page
p. 110
p. 111
Date of C alib ration: '/ z 7 A &
Field Equipment Calibration Record
D evice ( M ake and M odel) C a lib ra tio n S ta n d a rd s
Calibrated by:
7P h u . . p h
3TT
Loca tio n of Instrum ent Use:
+ A t t u r f M r& R u J / i 9 . * //3 5
/
<u+0> 7 > la o Z . * # *
r
0 A F > ? `> <? f o f r c c l
m V.
Date of Equipm ent Use:
2 .-/-/D 2 -X -/* 2 -3-A&
T a ti) A - i - f j t t f t c h "
C o ri.) CZCV
" ' CCI/
V*lv
Soci *
>
b fc.
Camp Dresser & McKee 50 Hampshire St.
Cambridge, MA 02140
p. 112
Date o f C alibration:
\/Z7/l0 7/
Field Equipment Calibration Record
(D e v ic e M a k e a n d M o d el)
C alib ration Standards
C alibrated by.
O ittrQ
..
'T o
T/f
*/fesfc
ZO 160
tir /j
o
Location of Instrum ent Use:
F<fZ/J-rd
F a trt/t& 'rl
Date of Equipm ent Use:
C a m p Dresser & McKee 50 Hampshire St.
Cambridge, MA 02140
D ate o f C a lib ra tio n :
\/Z7/(0 ^ ~ r~
Field Equipment Calibration Record
D e v ic e ( M a k e an d M o d e l)
C a lib ra tio n S ta n d a rd s
H * <n '/an P 0 J #7*0 'T uiK Z t 7>iry l * 2 0 ti r o
l
S 'a s
C a lib ra te d by:
L o c a tio n o f In s tru m e n t U se:
FTBrtrtft'Z* r i
D a te o f E q u ip m e n t U se:
p. 113
Dam p Dresser & M cK ee 50 H am pshire St.
Cam bridge, M A 0 2 1 4 0
p. 114
O
D
xipuaddv
Baron & Budd, P.C.
Emerald Coast Utilities Authority Production Well Sampling Escambia County, Florida
Analytical Data/Chain-of-Custodies (Hard Copy and Compact Disk)
p. 115
Appendix D
A C Columbia C . J Analytical Services"
p. 116
www.caslab.com
February 22, 2010
Analytical Report for Service Request No: K1000911
David Anderson Camp Dresser & McKee, Incorporated 325 John Knox Road Building M, Suite 100 Tallahassee, FL 32303
RE: Baron & Budd P.C/95779-75319
Dear David:
Enclosed are the results of the samples submitted to our laboratory on February 02, 2010. For your reference, these analyses have been assigned our service request number K1000911.
Analyses were performed according to our laboratory's NELAP-approved quality assurance program. The test results meet requirements of the current NELAP standards, where applicable, and except as noted in the laboratory case narrative provided. For a specific list of NELAP-accredited analytes, refer to the certifications section at www.caslab.com. All results are intended to be considered in their entirety, and Columbia Analytical Services, Inc. (CAS) is not responsible for use of less than the complete report. Results apply only to the items submitted to the laboratory for analysis and individual items (samples) analyzed, as listed in the report.
Please call if you have any questions. My extension is 3281. You may also contact me via Email at PDivvela@caslab.com.
Respectfully submitted,
Columbia Analytical Services, Inc.
Pradee, Project Chemist
PD/afs
Page 1 of 3/ 1)
ASTM A2LA CARB CAS Number CFC CFU DEC DEQ DHS DOE DOH EPA ELAP GC GC/MS LUFT M MCL
MDL MPN MRL NA NC NCASI ND NIOSH PQL RCRA SIM TPH tr
Acronyms
p. 117
American Society for Testing and Materials
American Association for Laboratory Accreditation
California Air Resources Board
Chemical Abstract Service registry Number
Chlorofluorocarbon
Colony-Forming Unit
Department of Environmental Conservation
Department of Environmental Quality
Department of Health Services
Department of Ecology
Department of Health
U. S. Environmental Protection Agency
Environmental Laboratory Accreditation Program Gas Chromatography
Gas Chromatography/Mass Spectrometry
Leaking Underground Fuel Tank
Modified
Maximum Contaminant Level is the highest permissible concentration of a
substance allowed in drinking water as established by the USEPA.
Method Detection Limit
Most Probable Number
Method Reporting Limit
Not Applicable
Not Calculated
National Council of the Paper Industry for Air and Stream Improvement Not Detected
National Institute for Occupational Safety and Health
Practical Quantitation Limit
Resource Conservation and Recovery Act
Selected Ion Monitoring
Total Petroleum Hydrocarbons
Trace level is the concentration of an analyte that is less than the PQL but greater than or equal to the MDL.
2
Inorganic Data Qualifiers
# 'Die result is an outlier. See case narrative. # The control limit criteria is not applicable. See case narrative. B The analyte was found in the associated method blank at a level that is significant relative to the sample result as defined by the
DOD orNELAC standards. E The result is an estimate amount because the value exceeded the instrument calibration range. J The result is an estimated value that was detected outside the quantitation range. U The analyte was analyzed lor, but was not detected ("Nnn-detect") at or above the MRL/MDL.
D O D -Q S M 4 l d e fin itio n : Analyte was not detected and is reported as less than the LOD or as defined by the project. The detection limit is adjusted for dilution, i The MRL/MDL or LOQ/LOD is elevated due to a matrix interference. X bee case narrative. Q See case narrative. One or more quality control criteria was outside the limits.
Metals Data Qualifiers
# The control limit criteria is not applicable. See case narrative. J The result is an estimated value that was detected outside the quantitation range.
E The percent difference for the serial dilution was greater than 10%, indicating a possible matrix interference in the sample.
M The duplicate injection precision was not met. N The Matrix Spike sample recovery is not within control limits. See case narrative. S The reported value was determined by the Method of Standard Additions (MSA). \ j The analyte was analyzed for, but was not detected ("Non-detect") at or above the MRL/MDL.
D O D -O S M 4 } d e fin itio n : Analyte was not detected and is rqxirted as less than the LOD or as defined by the project. The detection limit is adjusted for dilution. W The post-digestion spike for furnace AA analysis is out of control limits, while sample absorbance is less than 50% of spike absorbance. i The MRL/MDL or LOQ/LOD is elevated due to a matrix interference.
X See case narrative. + The correlation coefficient for the MSA is less than 0.995. Q See case narrative. One or more quality control criteria was outside the limits.
Organic Data Qualifiers
# The result is an outlier. See case narrative. # The control limit criteria is not applicable. Sec case narrative. A A tentatively identified compound, a suspected aldol-condensation product. B The analyte was found in the associated method blank at a level that is significant relative to the sample result as defined by the
DOD orNELAC standards. C The analyte was qualitatively continued using GC/MS techniques, pattern recognition, or by comparing to historical data. D The reported result is from a dilution. E The result is an estimate amount because the value exceeded the instrument calibration range. J The result is an estimated value that was detected outside the quantitation range. N The result is presumptive. The analyte was tentatively identified, but a confirmation analysis was not performed,
p The GC or HPLC confirmation criteria was exceeded. The relative percent difference is greater than 40% between the two
analytical results. y The analyte was analyzed for, but was not detected ("Non-detect") at or above the MRL/MDL.
D O D -Q S M 4 1 d e fin itio n : Analyte was not detected and is reported as less than the LOD or as defined by the project. The detection limit is adjusted for dilution. i The MRL/MDL or LOQ/LOD is elevated due to a chromatographic interference.
X See case narrative. Q See case narrative. One or more quality control criteria was outside the limits.
Additional Petroleum Hydrocarbon Specific Qualifiers
F The chromatographic fingerprint of the sample matches the elution pattern of the calibration standard.
L The chromatographic fingerprint of the sample resembles a petroleum product, but the elution pattern indicates the presence of a greater amount of lighter molecular weight constituents than the calibration standard.
H The chromatographic fingerprint of the sample resembles a petroleum product, but the elution pattern indicates the presence of a greater amount of heavier molecular weight constituents than the calibration standard.
O 'file chromatographic fingerprint of the sample resembles an oil, but does not match the calibration standard. Y The chromatographic fingerprint of the sample resembles a petroleum product eluting in approximately the correct carbon range,
but the elution pattern does not match the calibration standard. Z The chromatographic fingerprint does not resemble a petroleum product.
3
P- 118
p. 119
Columbia Analytical Services, Inc. Kelso, WA
State Certifications, Accreditations, and Licenses
Program
Alaska DEC UST Arizona DHS Arkansas - DEQ California DHS Colorado DPHE Florida DOH Hawaii DOH Idaho DHW Indiana DOH Louisiana DEQ Louisiana DHH Maine DHS Michigan DEQ Minnesota DOH Montana DPHHS Nevada DEP New Jersey DEP New Mexico ED North Carolina DWQ Oklahoma DEQ Oregon - DHS South Carolina DHEC Utah DOH Washington DOE Wisconsin DNR Wyoming (EPA Region 8)
Number
UST-040 AZ0339 88-0637 2286
-
E87412
-
-
C-WA-01 3016 LA050010 WA0035 9949 053-999-368 CERT0047 WA35 WA005
-
605 9801 WA200001 61002 COLU C1203 998386840
-
ACIL
m ig rili
4
Case Narrative
p. 121
COLUMBIA ANALYTICAL SERVICES, INC.
Client: Project: Date Received: Sample Matrix:
Camp Dresser & McKee. Inc. Baron & Rudd, P C 02/02/1() to 02/03/1() Water
Service Request No.:
K1000911
CASE NARRATIVE
All analyses were performed consistent with the quality assurance program of Columbia Analytical Services, Inc. (CAS). This report contains analytical results for samples designated for Tier III validation deliverables including summary forms and all of the associated raw data for each of the analyses. When appropriate to the method, method blank results have been reported with each analytical test.
Sample Receipt
Nineteen water samples were received for analysis at Columbia Analytical Services between 02/02/10 and 02/03/10. The samples were received in good condition and consistent with the accompanying chain of custody form. The samples were stored in a refrigerator at 4C upon receipt at the laboratory.
Perfluorinated Sulfonic Acids and Perfluorinated Carboxylic Acids by HPLC/MS
Surrogate Exceptions: The recovery of Perfluoro-n-[ 1,2-13C2]undecanoic Acid in Field Blank 2, Bronson "Raw", W & Avery "Raw", West Well Plant "Treated", F:Scott "Raw", Bronson "Treated" MS. and Bronson "Raw" DMS was outside the control limits listed in the results summary. The limits are default values temporarily in use until sufficient data points are generated to calculate statistical control limits. Based on the method and historic data, the recoveries observed were in the range expected for this procedure. No further corrective action was taken.
The recovery of Perfluoro-n-[ 1,2,3,4-13C4] butanoic acid, Perfluoro-n-[l,2-13C2]undecanoic Acid and Perfluoro-n[I,2-13C2]dodecanoic Acid in University Parkway "Treated" were outside the control limits listed in the results summary. The limits are default values temporarily in use until sufficient data points are generated to calculate statistical control limits. Based on the method and historic data, the recoveries observed were in the range expected for this procedure. No further corrective action was taken.
The recovery of Perfluoro-ii-[l,2-13C2]undecaiioic Acid and Perfluoro-n-[l,2-13C2]dodecanoic Acid in McCory "Treated", Lillian "Raw", ", Lillian "Treated", West Pensacola "Raw", West Pensacola "Treated", W & Avery "Treated", West Well Plant "Raw", F:Scott "Treated", and Bronson "Raw" DMS were outside the control limits listed in the results summary. The limits are default values temporarily in use until sufficient data points are generated to calculate statistical control limits. Based on the method and historic data, the recoveries observed were in the range expected for this procedure. No further corrective action was taken
No other anomalies associated with the analysis of these samples were observed.
Approved by
Date
6
Chain of Custody Documentation
Columbia Analytical Services*
1317 South 13th Ave
CHAIN OF CUSTODY
Kelso, WA 98626 (360)577-7222 (800)695-7222x07 FAX (360) 636-1068
PAGE
SR#: m
m
CO C#
123
RELINQUISHED BY:
Signature Printed Name
Date/Time
'Firm
-- ------------------------------------------------ ------------------------------------------------------------------------------
V \ "RECEIVED BY:
Z-l /0
Stonature a . fiv A L
D ate /T im e C ,o fj\
Printed Nam e
Firm
H \ rsRELINQUISHED BY:
Printed Nam e
Firm
RECEIVED BY:
Signature ^n'rited Nam e
C -A i Firm
RCOC #1 07 0 `
Columbia Analytical Services
CHAIN OF CUSTODY
1317 South 13th Ave. Kelso. WA 98626 (360)577-7222 (800)695-7222x07 FAX (360) 636-1068
PROJECT NAME PROJECT NUMBER
/Ko X i\ .d ? Z
t 'i n
(V.KV t dPROJECT MANAGER A v ^ e i l A M i v \
COMPANY-ADDRESS
_________ m _____________ rt______
\riX -- T|rx/rv\vA\ \f>\h _ (l A
2 in
C/TY'STATE ZIP
T a LU W
E-MAIL ADDRESS
a/V W --
tro
SAMPLER'S SIGNATURE
S A M P L E I.D. U / a V j c M TrsvL<%J '* X r> o 5/X veL,V Ojs, / ^
K c a j i i f i J*t ciA -f
DATE 2.1O 2 -/-/C
2 -/7 0 Z 'U *
T IM E IZ 'iS mo 13 S S
m is
O a a c a, ^ ^ U ^ 11
O
2 --Q Z / .X
mu
l i o8
L A B I.D. MATRIX
6^ Y KJ
Z
z
a.
6 -UJ 6 -^
2_ 2~
lU 2 -
6-U 3 ' Z
PAGE 'Z ,
SR#: k ./ O ^ 1
OF -2_
COC #
REM ARKS
Y X
Y
_X
X
-
REPO RT REQUIREMENTS
___ 1. Routine Report: Method Blank, Surrogate, as required
II. Report Dup., M S, M S D as required
III. Data Validation Report (includes all raw data)
X IV. C L P Deliverable Report
INVOICE INFORMATION P .O .# B ill To:
Total Metals: Al A s Sb Ba Be B C a Cd C o C r Cu Fe Pb Mg Mn Mo Ni K Ag Na Se Sr Tl Sn V 2 n Hg Dissolved Metals. Al A s Sb Ba Be B C a Cd Co C r Cu Fe Pb Mg Mn Mo Ni K Ag Na Se Sr Tl Sn V Zn Hg
"INDICATE STATE H YD RO CARBO N PR O CED U RE: AK C A Wl NO RTH W EST OTHER: TU RN ARO U N D REQ UIREM ENTS SPECIAL INSTRUCTIONS/COMMENTS: _____ 24 h r . _____ 48 hr. _____ 5 Day
Standard (10-15 working days)
_____ Provide FAX Results
(CIRCLE ONE)
X V. EDD
RELINQUISHED BY:
Signature Printed Name
DateTTime Firm
Requested Report Date
V fv
RECEIVED BY:
IS W
U ./O / 6 i o
Signature
D ate -T im e
n ftL--a L . M -XuaifcA
c X fA
Printed Nam e
Firm
\
t \ IV R ELIN Q U ISH E D BY:
//fix
X.}.f o
Printed Nam e
Firm
-^gTWiifflr.. Signature., JU X , K e nm Printed Nam e
l
Firm
RCOC *1 07 Of
Columbia Analytical Services-
CHAIN OF CUSTODY
1317 South 13th Ave. Kelso, W A 98626 (360) 577-7222 (800) 695-7222x07 FAX (360) 636-1068
"" "
PROJECT NUMBER
<=J ^
-
H v J ,A
^5"3/T '
7,^P> C
D iL iv v M /v tM /fvOMPROJECT MANAGER
^
avi
A VL iVvilVVVXA Ulj?COMPANY/ADDRCSS w A
a
|A
/
t-f) C^~i\
I1
/1
VfIfi/
Ci TY/ STATE/ Zl P
_______ ~ __e -m ail a o g r ess
., ,
_J
' A A I sJls^rjp a trrLr
7
PHONE'
SAMPLER'S SIGNATURE"
FAX #
^ ^
1-2
S^ _ 1
of i /
J7 oAt//
fj//
S A M P L E l.D.
DATE
T IM E
/ ^ 7/ /,LA B l.D. MATRIX
f 14 - W O
n^ 2-
AJo
T ~ fT fi lr
A*0 "
2 ..2 -/0
^ v
a . 27
PAGE
SR#: Y ()i\() u/ / /
OF 3
COC #
REM ARKS
X
REPO RT REQUIREMENTS
___ 1. Routine Report: Method Blank, Surrogate, as required
___ II. Report Dup., MS, M S D as required
___ III. Data Validation Report (includes all raw data)
IV. C L P D eliverable Report
^ V. EDD
INVOICE INFORMATION P.O . # _____________________ B ill To:
Circle which metals are to be analyzed: Total Metals: A l A s S b B a B e B C a C d C o C r C u Fe P b Mg M n M o Ni K A g N a S e Sr T l S n V Zn Hg
Dissolved Metals: A l A s S b B a B e B C a C d C o C r C u F e P b M g M n M o Ni K A g N a S e S r T l S n V Zn Ftg
INDICATE STATE H YD R O C A R B O N PR O C E D U R E : A K CA Wl N O RTH W EST OTHER:.
TU RN ARO U N D REQ UIREM EN TS SPECIAL INSTRUCTIONS/COMMENTS:
_____ 24 hr.
_____ 48 hr.
. (CIRCLE ONE)
_____ 5 Day
Standard (10-15 working days) Provide FAX Results
C o n ta in e r S u p p ly N u m b er
16394
Requested Report Date
16394
RELINQUISHED BY:
Signature Printed Name
D ate /T im e Firm
\ RECEIVED BY:
|j
Signature n Printed Nam e
D ate/T im e c* ^
Firm
^
\ RELINQUISHED BY:
Signature , 0 A v-'-J A tA J e c A Printed Nam e
D ate/T im e C j O lA\
Firm
RECEIVED BY:
S ig n ature Printed Name
"Firm
/o zc
RCOC 1 07
125