Unit No. M axim um Sq. F t. Direct Radiation Lb*. Pres*.' Pump w ill Dizch. Against Horsepower M o to r' Furnished ICapacity Pump in |Gals. per M in. Dia. Receiver, In.; also Floor Space 11
H.P. Motor for 10 lb. Pressure Water Pump Capacity, C .p .m . Size Return Inlet in Inches
Pumps
Chicago Pump Company
Office and Works
2330 Wolfram Street
Chicago, 111.
QUALITY CENTRIFUGAL PUMPS, Condensation, Sump, Vacuum, Sewage, House Circulating, Fire, Pneumatic, Electric Cellar Drainers, and the
Automatic Alternator.
Arizona.
Phoenix, J. W. Ladlow
Alabama,
- BirminpAam, C. P. Leibold
California,
Lot Anode*.
Smith Booth Usher Co.
San Francisco, J. A. Lardie
Colorado,
Pueblo, M. R. Schwer A Co.
Denver, A. Wallace A Co.
Connecticut,
Hertford,
Boiler Equipment Co.
D.C., Washington, W. L. Ticer
Florida,
Coconut Grove,
Ozanne-Magmder Co.
Jacksonville, G. E. Osgood
Tampa, H. G. Carter
Georgia,
-.
Atlanta, J. R. Whitman
Savannah, Bergen A Peck
Illinois,
Peoria, C. E. Eallister Co.
Indiana,
Fort Wayne,
Domestic Sides Co.
Indianapolis,
W. P. Whittington Co.
Iowa, - Dee Moines. E. B. Carr
Sioux City, Wigman Co.
Davenport,
A. R. Boudinot
List of Representatives
Kansas. Wichita, J. M. O'Connor
Kentucky, Louisville, Wallace Hoeing,
Louisiana, New Orleans,
Nebraska, Lincoln, Cornell Supply Co. Omaha, H. A. Campbell
New Jersey, Newark, J. M. Chipman
New York,
F. H. Chisholm
Buffalo,
Maryland, Baltimore, Chicago Pump Co.
Massachusetts, Boston, Monahan Pump Equip. Co. Michigan, Detroit, Chicago Pump Co. Grand Rapids,
Busbnell-Felton, Inc. New York, Chicago Pump Co. Rochester, R. C. Schwarz Utica, H. F. Bantham
North Carolina, Charlotte, Amer. Machinery Equipl Co.
C. H. Alexander Saginaw, R. R. Kimble
Ohio, Cincinnati,
Minnesota, Minneapolis, Cash Co.
Mississippi, Jackson, Paine Machinery Co.
Mibsouri, Kansas City, Industrial Power Equip. Co. Springfield, J. B. McCarty
C. R. Lingo Engr. Sales Co. Cleveland, Chicago Pump Co. Columbus, J. T, Seidera Toledo, M. C. Griffin
Oklahoma, Oklahoma City, Federal Steam Spec. Co.
Oregon,
St. Louis,
Portland, P. W. Beggs
Foster Mechanical Equip. Pennsylvania, Co. Philadelphia,
Montana, Butte, Sullivan Valve St Engr. Co.
Culbert-Whitby Pittsburgh, F. W, Rockstraw Co.
South Carolina, Greenville, James McCabe
Tennessee, Chattanooga, Southern Sales Co. Knoxville, Morris Bradt Memphis, C. L. Ahler Nashville, Southern Sales Co.
Texas, Amarillo, Clowe A Cowan Dallas, Smith A Whitney Houston, Dalton-Heyne Co. McAUen, H. L. Draper Son Antonio, Dalton-Heyne Co.
Utah, Salt Lake City, E. G. Dewald
Virginia, Richmond, Virginia Equip. A Supply Co.
West Virginia, Charleston, H. DeB. Miner
Wisconsin. Milwaukee, Swisher Maurer A Co.
Washington, Seattle, Heating Service Co. Spoione, W. B. Starky
VERTICAL CONDENSATION PUMP AND RECEIVER
The vertical condensation pump and receiver is designed particularly to collect the return from beating coils, etc., that come hack below the floor level No concrete pit is required, the unit being adaptable to ground installation, thus using a minimum of floor space. ASK for Bulletin X33.
HORIZONTAL CONDENSATION PUMP AND RECEIVER
Horizontal condensation pumps and receivers are designed for capacities up to 150,000 sq. ft. of direct radiation and boiler pressures to suit any job. All units are mounted on one base and are assembled at the factory. Simple construc tion. quiet operation, and low operating costs are a few of
the outstanding features.
1650 1651 1652
1654 1655 1656
1658 1659 1660
1662 1663
1665 1666
1668 1669 1670
3,000 *
6,000
10,000 *
15,000 *
25,000
40,000
10 1/ 22
10 17 22
10 17 22
14 16
12 16
10 14 21
Vi 5
Vi "
1* Vi 10
V.
1*
'A 15 V. 1
V, 21 1
y 35 1
V. 55
1 m
24 " * 24 "
24 " *
204
30*
30
Vertical Condensation
Pump
Fig. 1940
"Sure Return" Condensation Pump--Fig. 1947
The "Sure Return" condensation pump and receiver is especially designed for low and medium capacities and boiler pressures up to 10 lb. AU parts are standard and interchangeable. Delivery can be made on this unit in 24 hours. Ask for Bulletin 131:
Automatic Alternator.--Provide a Chicago Pump Compony's Automatic Alternator which will automatically transfer the operation from one pump to the other. This alternator will also start the second pump in the event of the failure of thefirst pump, or will cause both pumps to operate ifnecessary.
718
Chicago Pump Company
Pumps
"CONDO-VAC" VACUUM CONDENSATION PUMPS
Single "Condo-Vac" Fig. 1990
For the efficient operation of a vacuum heating system where steam must be made to circulate quickly throughout the system, and where the condensate must be returned as quickly as possible to the boiler, the "Condo-Vac" has been highly recommended.
Many "Condo-Vacs" now giving 100 per cent service attest to its efficiency.
The "Condo-Vac pump is completely bronze fitted, having shaft, rotor, impellers, wearing rings, and impeller and rotor nuts of bronze. This is the same construction as the well known "Chicago" D-Type pumps which are noted for their long life and splendid wearing qualities.
The Receiver of the "Condo-Vac," which also serves as a base, is made of cast iron. Several ribs and post supports give this receiver great strength and assure its vibrationless rigidity when the pump is in operation. The construction ofthe receiver eliminates the necessity of a special founda tion for the pump and forms an ideal base for the pump proper. Cleapout plates are furnished for front and bac* of receiver 8nd afford adequate means of cleaning the receiver when necessary. A drain is provided for the depres sion on the top of the receiver.
A heavy cast iron base carries the motor and is ad justable for various motor heights--base provides plenty of ventilation for motor.
The new "Condo-Vac" is inexpensive to install as no special foundation iB necessary. The receiver is heavy and flat, and is altogether adequate to serve as a solid base. All piping and wiring in the unit itself is done at the factory.
ARCHITECTS' SPECIFICATIONS
DUPLEX "CONDO-VAC"
Furnish and install where indicated on plans, a duplex
"Condo-Vac," centrifugal condensation and vacuum return
line pump as manufactured by the Chicago Pump Company.
This unit shall be a complete duplex pump mounted on one
cast iron receiver together with all apparatus necessary for
duplex automatic vacuum and float switch control
Each pump shall have a capacity of direct radiation and shall have a pressure of at the pump discharge.
sq. ft. of lb.
Cast iron receiver shall be so arranged that inlet will not
be more than 12 in. from the floor. Pump casing shall be
horizontally split. Suction strainer shall be placed between
vacuum pump and receiver. Each pump shall be equipped
with two out-board bail bearings.
Control apparatus shall include two enclosed, fused, main
line switches, two enclosed float switches, two enclosed,
automatic, vacuum switches, two manual vacuum cut out
switches, and two enclosed automatic starters providing
overload and low voltage protection. Each unit shall be
controlled by its own vacuum switch and float switch, and
raping and wiring shall be so arranged that either unit ean be operated independent of the other.
All wiring and electrical connections between motors and
control apparatus will be made when equipment is assem
bled at the factory. The entire pumping equipment is to
be shipped from the factory in a complete unit, leaving
only wiring between electrical service ana motor and piping
connections between inlet to receiver and discharge of pump
to be done after pump has been shipped.
s D
2601 2602 2603 2604 2605
"CONDO-VAC" TABLES For 10 lb. Pressure at 1720 r.p.m.
.2c
.
8000 16000 26000 40000 65000
d" g
2 <U>
15 l'/l 10 2 16 3 21 5 36
12 24 39 60 96
V
Sj .it
HI gx 2*
Ms Ui
l/42 48x56
3 IVi 56x60 3 M/, 60x62 4 2 66x62 42
2609 2610 2611 2612 2613
For 20 lb. Pressure at 1720 r.o.m.
8000 I'A 5 12
2 l'/4
16000 2
9 24
3 II/4
26000 3
vh40000 5
65000
15 19 34
39 60 96
23 VA
4 42
48x56 56x60 60x62
66x62
F. C. CONDENSATION PUMP
Duplex "Condo-Vac" Fig. 1981
The F. C. or Float Controlled type condensation pump and receiver is designed for low, medium and high boiler pressures and capacities up to 1S0.000GPM. Bulletin 129.
Horizontal Condensation Pump Capacities, Horsepower and Floor Space tables may be had by asking for Bulletin.
719