Therminol fluid Heat systems
a design, operating, and maintenance guide or low-cost, low-pressure heat transfer.
ic/rr-31
TOWOLDMONOQ39421
0616076
"Nothing contained herein Is to be WARRANTIES AS TO THE FITNESS
construed as a recommendation OR MERCHANTABILITY OF ANY
to use any PRODUCTS
proauct in comuci REFERRED TO, ino
wguiinaraannlyepeaotef nsta.tiMsfOacNtSorAyNrTeOsuMltsAKfrEomS
NO re
liance upon contained information or recommendations, and disclaims all liability for any resulting loss pr dapSage."
2-334B-0173 10 UTHO IN U.S.A.
TOWOLDMONOQ39422
Page
Therminol Economies in Indirect Heating................................................... 2 Typical Applications....................................................................................... 3 General Design Factors.................................................................................. 4
System Factors......................................................................................... 4 Fluid Factors............................................................................................. 5 Design Factors of Components..................................................................... 6 The Heater................................................................................................ 6 Determination of Heat Transfer Coefficients.......................................... 8 Pumps-- Filters-- Materials................................................................. 8-9 Expansion Tank........................................................................................ 9 Pipework.................................................................................................. 9 Expansion Tank & Cold Seal Trap........................................................... 10 Insulation -- Packing -- Valves -- Controls........................................... 11 Fire Protection -- Safety Controls........................................................... 12 Typical Systems............................................................................................... 13 Start-Up Procedure......................................................................................... 17 Operating Instructions.....................................................................................18 Safe Handling & Disposal...............................................................................19 Engineering Data............................................................................................. 20
Therminol is a registered trademark of Monsanto Company '
06lt.077
!
TOWOLDMONOQ39423
f
Therminol Heat Transfer Fluids new economies in indirect heating
Monsanto has had over two decades of experience engineering and formulating fluids for transfer of heat. Systems for using Therminol fluids have been developed that run the gamut of indirect heating and cooling applications, from chemical and petroleum processing to space heating.
Therminol fluids are available for heat transfer in a series of temperature operating ranges. The range extends from a high temperature fluid operable up to 800F to a low temperature fluid operable above 575F that still remains a liquid below -70F for cooling applications.
The major economies in using Therminol liquid heat transfer over steam or other vapor systems is the lower cost of the installation and operation. Unpressurized or low pressure Therminol liquid systems can significantly reduce capital costs. The savings in eliminating installation of large diam eter vapor piping, flash drums, safety valves and pressure control devices can amount to 25-50% of system cost. A second source of savings is in operation: the non-pressurized systems require minimum maintenance, eliminate heat lost by condensation in supply lines, and do not usually require licensed operating personnel.
The major advantages of a Therminol system over oil is greater versatility in operating temperature, better chemical stability, reduced make-up, and closer control of and faster response to temperature change as required by the operation. Therminol fluids have greater heat carrying capacities and more practical viscosities over their temperature range. In a properly designed system, Therminol fluids will give temperature control to within 2F, have little degradation sensitivity, and give long trouble-free service.
The number of divers applications for indirect heating with Therminol fluids is virtually limitless. Monsanto offers Therminol fluids suited for low, medium or high temperature operating ranges. The fluids possess various chemically-engineered use-advantages. These include better pumpabilify^ high heat carrying capacity, low pour point, thermal- and chemical stability, low vapor pressure, good viscosity index, and others. These fluid characteristics have proven advantageous in heat transfer systems such as the typical installations listed.
Monsanto's Therminol fluids are described in a brochure on each fluid that describes its essential physical and thermal properties. The following pages detail the general engineering concepts to be observed and recommendations for the design of systems, their operation and maintenance. By applying the physical constants of the particular fluid to be used to the engineering parameters described -- the system designed will be most economical to construct, efficient to operate and most satisfactory in its performance.
2 0616078
TOWOLDMONOQ39424
Therminol Fluid Heat Transfer can be used in these applications:
Tanker and Barge Heating Off Shore Oil and Gas Platform Heating Chemical Process Heating Rubber, Plastics and Paper Processing Heat Waste Heat Recovery Systems Alkyd Paints and Resin Kettle Heating Space Heating for Apartments and Public Buildings Petroleum Refining Brine Liquors Concentration and Distillation Bituminous Materials Heating Converters: Calendering, Crimpers, Hot Presses Metal Treating: Annealing, Stress-Relieving Welds and Castings Heaters Surface Coatings Curing and Commercial Baking Ovens Synthetic Fiber Production and Finishing Process Heating 4
> (I
TOWOLDMONOQ39425
General design factors in Therminol heat transfer systems
Advantages of proper design
Therminol systems provide heating and cooling at relatively low capital cost. The fluid gives long service, the system requires minimum maintenance, and installations do not usually require supervision by a licensed stationary engineer. Properly designed, the savings with Therminol systems are cumulative.
The Therminol fluid for a particular system is selected according to the temperature requirements of its operation. In any range, the fluids are ideally suited for systems that must deliver uniform heat (up to 800F), precise temperature control, and quick response to heating or cooling demand.
While there is nothing profoundly different or highly complicated about a Therminol system (compared with older liquid heat transfer systems) certain design parameters must be observed for the system to give trouble-free service, to operate efficiently, and to return all the benefits of heating or cooling with a non-pressurized liquid.
The basic engineering checkpoints of designing a system are three fold:
1) The heater: to insure non-degrading delivery of heat from the fuel,
2) The pumps and piping: to insure proper handling of the fluid and maintain the correct flux at user stations and adequate system circulation, and
3) The materials and construction: to insure compatibility and proper layout and design.
With sufficient heater capacity, good control of flow at user-stations and compatible materials, a well-designed Therminol system will give reliable,
efficient, and precise delivery of heat. Proper selection of fluid and a clean, moisture-free system will ensure minimum maintenance and trouble-free operation.
System factors
Liquid heat transfer is basically heating an adequate quantity of fluid to a practical working temperature, circulating it to heat-accepting user stations at a rate to raise or maintain the temperature of the heat-user as required by the process. Thus in designing a system, the following requirements should be considered:
1. Is the process a continuous or batch operation ?
2. What is the heat demand and temperature requirement of each heat user? The cooling
requirement?
06160B0
TOWOLDMONOQ39426
3. How much heat transfer area will be practical or available at user-stations and what coefficients of heat transfer can be expected from the product at the user surfaces?
A, Will more than one heat-user be on stream at the same time ? At the same temperature ? At different temperatures?
5. What heat losses will be expected in the physical layout of the system ?
C. Can existing heating requirements be served by incorporating in the new system to eliminate older equipment or eliminate other types of heat delivery ?
7. Are expanded heating requirements probable?
A basic starting point is to estimate the heat balances and determine the total heat demand of the system, This will guide selection of the heater capacity, delimit fluid operating temperatures, and indicate the type of Therminol fluid the system will require.
Fluid factors
Therminol heat transfer fluids are chemically and thermally stable liquids. They resist chemical and physical change at all temperatures below their maximum bulk temperature operating limits. The operating temperature limits for each Therminol fluid are specified on the product's data sheet. When not subjected to contamination or heat stress beyond their limits, Therminol fluids will give years of service without significant physical or chemical change. Simple laboratory tests should be made periodically on Therminol fluid to determine its condition as part of good system maintenance.
Therminol fluid is used as a liquid phase heating medium, so transfer of heat is by sensible mode rather than latent mode as with condensing vapor. Heated liquid, circulated at reasonable velocities over a heat-using surface, can be a more efficient and more readily controlled method of heat transfer than pressure-controlled condensing vapor systems.
Therminol fluids are designed to have physical properties that enhance their value in liquid phase heat transfer. Low vapor pressure and high boiling ranges permit operation at their maximum recommended temperatures without the need to pressurize the system. The particular types of chemical compounds used as the base stocks for Therminol fluids have always been recognized as among the most thermally stable.
As with any heat transfer fluid, the design of the system must take into account the relationship between liquid velocity and the heat load from the heat source. The liquid film in immediate contact with the heat donor surface (whether the heater fuel is electricity, gas or oil) is subjected to higher temperatures than the bulk temperature of the
balance of the fluid. The velocity of the circulating fluid, therefore, is the critical determinant of how long the film is subjected to the higher temperature. The differential between the fluid bulk temperature and the film temperature is dependent upon the fluid velocity over the surface of the heat donor and the physical properties of the fluid used. Therminol fluids have high specific heat and thermal conductivity values which make them efficient heat carriers. In selecting both the heater and the fluid, the maximum film temperature -- rather than the average -- should be considered and a reasonable margin allowed to enable the fluid to give the longest practical service life, The proper selection of fluid is important. It is the link between the heat donor and the heat user. Therminol fluids are formulated to provide a strong and efficient link for both heating and cooling demands. Each Therminol fluid is supplied with its maximum bulk fluid temperature specified. Therminol fluids are available for operating in a series of ranges, from low temperature fluids operable from below -70 to above 575? ( -- 56 to 302C) to high temperature fluids suitable for heating to 800F (427C).
v'
L
0616061
6
TOWOLDMONOQ39427
COMPONENTS
Design factors of the components of a Therminol system
The heater
The heater is the most critical component in designing a Therminol system. With the proper balance of heating capacity, temperatures and fluid velocity the service life of the heat transfer fluid is increased to the maximum. Two basic fired heater designs for Therminol fluids are available: the liquid tube and fire tube types. In liquid tube heaters, the Therminol is pumped through the tubes as it is heated; in fire tube types, Therminol flows through the "shell'' of the heater surrounding the fired tube or multiples. When bulk fluid operating temperatures of 500F (260C) (or higher) are required, a liquid tube type heater is to be preferred ... unless a specific heater design is devised to force a uniform steady flow of liquid over the heat donor surfaces. Therminol fluids transfer heat as liquid. To avoid hot spots in a Therminol heater, the fluid should be pumped over the heating surfaces at sufficient velocity so that no area of stagnant fluid occurs. Fluid velocities over the heat donor surfaces should be relatively high; generally 4 to 10 feet per second. This helps avoid excessive film temperatures that may be detrimental to heat donor surfaces and to the fluid. The following illustration shows the effect of fluid velocity on film temperature and indicates the importance of this heater design requirement.
0bl60Bi
TOWOLDMONOQ39428
EFFECT OF LIQUID VELOCITY ON FILM TEMPERATURE DURING HEATING
Low Liquid Velocity
<s
In electrical immersion heaters, all the heat delivered by the elements passes into the fluid. The wattdensity on the surface of the heat donor and the fluid velocity over it should be in proper balance to avoid excessive film temperatures. Watt-densities in the range of 8 to 10 watts/sq.in. with a minimum velocity of 4 feet/second are a practical relation. Electrical heaters are available with 18 to 22 watts/sq. in. densities that have proved satisfactory with much lower fluid velocities. With such low velocity heaters, however, the fluid selected should have a bulk operating temperature approximately 35F higher than the maximum intended use temperature,
In general, Therminol fluids will give long service life if the maximum bulk temperature does not exceed the recommended maximum bulk operating temperature for the particular fluid. When selecting a heater, it is essential that the design and capacity does not develop maximum film temperatures that exceed the ceiling for the fluid -- and the pumping capacity should be sufficient to maintain adequate fluid velocity over the heat donor surfaces.
.LIQUID 'FILM
\/ F'lm / temperature
LIQUID 'FILM
Film Temperatures
Since heating is not uniform in fired heaters, the maximum heat stress conditions must be used to determine what film temperatures will be encountered.
Example: (for a typical heater)
The film coefficient for fluid is: The bulk fluid operating temperature is: The average radiant absorption rate is: The maximum radiant absorption rate is:
Average Film Temperature
250 BTU/hr. sq. ft. F
570F
9,000 BTU/sq. ft. hr.
17,000 BTU/sq. ft. hr. 9.000
= 570 + W = 606 F
Maximum
Film Temperature
-
570
+
17'000 -250~ =
R,o=r
638 F
/ \i
I
--
0616083
I7
TOWOLDMONOQ39429
%
Determination of heat transfer coefficients
To determine overall heat transfer coefficients for the heating system, individual coefficients have to be calculated for heat donor side and the fluid service side at each user station, Film coefficients for Therminol fluids are best calculated using a Seider & Tate type* equation:
^ = 0.022 k
0.8 (DG)
b
0.4 CpH
k b
10.16
-- *= Reynolds Number (dimensionless)
c LX = Prandtl Number (dimensionless)
k
--~ = Nusselt Number (dimensionless) k lii. --- = Viscosity Correction Factor |iw
In this equation: h = The Therminol fluid's film heat transfer
coefficient D = Internal pipe diameter k = Thermal conductivity of the Therminol fluid
at bulk temperature *'b" G = Mass velocity of the Therminol fluid cP = Specific heat of Therminol at bulk
temperature "b" [i - Absolute viscosity of Therminol ub = The Therminol fluid's viscosity at bulk
temperature "b" The Therminol fluid's viscosity at wall (film) temperature "w" b = Bulk fluid temperature *A modification of the Seider & Tate equation for all liquids except water. Graphical data on Therminol film coefficients are given in each fluid's data sheet. Tabulated data is available on request.
Pumps
Pumps must have sufficient capacity and pressure head to circulate the fluid at the rate required by the particular installation. For large flow rates, the pump should generally be of the centrifugal type; any one of a number of the standard brands of high temperature pumps is suitable. For most systems, cast steel pumps are best. Pump manufacturers usually specify that above 450F (230C) a water-jacketed, deep stuffing box or a mechanical seal and watercooled bearings should be used. Mechanical seals are used widely today. On pumps with a stuffing box, at least five rings of packings should be provided, with graphite-impregnated metal foil around an asbestos core or laminar graphite rings such as Grafoil.*
When a new system is first put into operation, a slight leakage may be noticed at the pump packing. The pump gland should not be tightened however, until the system has heated up to close to the temperature of operation, Canned (glandless) pumps require no seal and have proved very serviceable in Therminol systems,
Regardless of the type of pump selected, the flow rate should be checked regularly against the pump's performance when new. To avoid shaft trouble and seal leakage, it is important to avoid pipe support stresses on the body of the pump. Each pump should be fitted with a control device to switch off the burner in case of pump failure.
If expansion loops are used in the pump section piping, they should be horizontal or vertically downward. Loops should not be vertically upwards, because this forms a trap which can collect air and vapor which seriously hamper the pump performance.
Carbonaceous deposits can also occur at the pump seal face due to leakage at high temperatures. The use of a seal flush system is helpful in preventing excessive seal wear.
Filters
In a new system, install a wire mesh strainer in the pump section.
When operating where solids and contaminants might enter the system, it is advisable to permanently install a high temperature filter by-pass line that can be isolated with valves for periodic cleaning.
Product of Union Carbide Co.
#
0616084 8
TOWOLDMONOQ39430
fr
Materials of construction (excluding heater colls)
The majority of metals normally encountered in high temperature heating systems can be used with Therminol fluids.
Materials of construction are generally selected on the basis of their suitability for operation at the specified maximum temperature, Mild steel is widely used.
The use of copper, aluminum, bronze and brass alloys etc, should be kept to a minimum mainly because of their loss of metallurgical strength at higher temperatures.
The expansion tank should be sized so that it is % full when the system is at room temperature and % full when the system is at operating temperature. It should be fitted with a sight glass at the full range and with a float operated, minimum level switch to shut off the heater in the event of accidental fluid loss,
Pipework
The most important factors in the piping layout for Therminol systems are: (A) Proper sizing for the required flow rate and (B) minimizing pressure drop. Because the system will undergo temperature changes, adequate loops to relieve expansion and contraction stress are essential. Schedule 40
The expansion tank and venting arrangements
seamless carbon steel pipe should be used throughout the system, It is characteristic of most organic heat transfer fluids (including Therminol) to have a
The expansion tank should be installed at the highest
tendency to leak through joints and fittings at high
point in the system and connected to the suction
temperatures unless these fittings are very tight.
0 side of the pumps. It should serve as the main venting point of the system.
The best way to prevent piping leakage is to weld all connections. Where access is necessary, use
The double drop leg expansion tank (see Figures a and b on page 10) provides greater flexibility of operation than a single leg tank. Venting of incondensibles, water, etc. is often difficult in a heating system. Purging out sir on start-up can also
raised-face flanges with appropriate gasketing and high-temperature bolting. Control of piping leaks is especially important, since fluid-soaked insulation poses a more serious hazard than the leaking fluid, itself. (See Section on Insulation).
be a problem. This particular arrangement ensures
When a flanged connection is made, USAS 300 lb.
flooded pump suction and uninterrupted flow on
weldneck or equivalent raised-face flanges are
start-up and allows venting as required.
recommended. The flanges should be back welded
It is preferable when designing the expansion tank to minimize air contact with fluid at temperatures exceeding 100F (40C) to prevent oxidation.
to the pipe and proper gasketing used, such as spiral wound asbestos and stainless steel gasket. Recommended flange gasketing for high temperature heat transfer fluid systems should be spiral-wound
The most effective way of preventing fluid oxidation is to blanket the system with an inert gas (such as nitrogen) as shown in Fig. a, If this is not desirable,
type conforming to API specification 601. Standard materials for spiral wound flange gaskets are Type 304 stainless steel and asbestos.
air contact can be minimized by a cold seal trap
arrangement as shown in Fig, b. Low boilers and
Important to non-leak performance with spiral wound
moisture can collect in the cold seal trap and the fluid in the trap should be discarded periodically.
gaskets is the use of raised-face flanges, alloy steel bolting and even compression of gasket during bolt
pull up.
Some systems operate without an allowance being
made for oxidation protection of the fluid in the tank,
In this case, the temperature in the expansion tank
should be kept as low as possible in order to
minimize problems which could result from fluid oxidation,
These guidelines are given to maximize fluid life which
C is particularly important in the case of the higher cost fluids. When using a nitrogen blanket, moisture
should be driven off from the fluid before the gas
pressure is set. Any vent lines should be led outside of the building so that vapors do not enter the
0616083
working area.
TOWOLDMONOQ39431
%
Figure a
Suggested Inert Gas Arrangement for Expansion Tank
For startup or venting operations, valves B, C, D. & E are opened 8nd Valve A is closed. All flow passes to expansion tank; degasses; vents; and maintains flooded pump suction.
For normal operation, valves B, C and E are closed and valves A & D are open. This arrangement provides normal return flow to pump suction with open static head line from tank to pump, Bypass line through valve D eliminates thermal siphon to expansion tank.
Figure b
Suggested Cold Seal Trap Arrangement for Expansion Tank
0616086
TOWOLDMONOQ39432
Insulation
Organic heat transfer fluids such as Thermino! exhibit a slow oxidation reaction with the air trapped inside the voids of the insulating material when system temperatures reach about 260 'C. (500 6F). Saturated insulation offers a large fuel surface in the face of poor heat dissipation conditions, end this, along with possible catalysis from the insulating material {magnesia, silicate-bonded asbestos or calcium silicate) can cause a temperature build-up in the mass. This temperature build-up can result in ignition of the fluid when the space between the piping and the saturated insulation is exposed to air (i. e., should the insulation be broken for repair, etc.).
This phenomenon is not fully understood, but appears to occur less with closed cell insulation than with the insulating materials mentioned above. Closed cell materials, then, are preferred, especially where leakage is a possibility despite all precautions.
The principle problem areas are near instrument connections, valve packing glands, flanges, and where cracks develop in relatively impermeable insulation cement adjacent to oil soaked insulation.
To obviate this problem, eliminate any source of leakage promtly. Replace leaky gaskets, oil soaked insulation, and re-pack valve stems. Cover insulation where leaks might occur with a hydraulic setting, oil-resistant cement. Install valves, where possible, with the stems in a horizontal position so that leaks will drip away from the insulation. And again, use closed cell insulating materials on suspect piping areas
Packing
Various types of packing are used to seal valve stems and small pump shafts on high temperature Thermino! systems. Flexible metal or solid graphite packings give the best service.
Graphite or Teflon impregnated, short fibre asbestos gasketing is used also, but leak-free service is not always achieved at the higher temperatures.
Generally, five rings of packing are specified on valve stems to assure a reasonable seal.
The use of metal bellows steam seals on valves is increasing and would, of course, provide absolutely leak-free service.
Valves
Cast steel valves with deep stuffing boxes are satisfactory for Thermino! systems. If it is possible, globe valves with an outside screw (as a protection against high temperatures) should be used throughout the system since they provide the only truly effective seal against Thermino/ fluids. Gate valves do not always provide a tight shut-off.
Controls
Controls for heating systems using TherminoI should be installed both on the heater itself and on the heat-using units. A wide variety of thermal-operating controls are available, and any reliable standard equipment is satisfactory.
Install heater controls to regulate the firing mechanism in direct proportion to the required output. These controls should increase or decrease the heat in-put to maintain the Thermino! at the operating temperature required by the heat-demand of the user. Small units may be operated satisfactorily by relatively simple "on-off" or "high-low" controllers; larger units will operate more uniformly if equipped with modulating temperature controls.
Install user controls to regulate the flow of the heat transfer fluid in proportion to the heat-consumption of the heat using equipment. In a multiple-user system, separate controls should be installed on each consuming unit, to assure the proper heat-delivery.
0616087
11
TOWOLDMON0039433
Fire protection
Generally speaking, where fire protection is concerned, it is best to consult your insurance company for guidance and counsel. Likewise, you will want to discuss your fire safety equipement requirements with qualified suppliers of fire protection equipment. Selection and sizing of fire protection equipment is important to safeguard the installation.
A commonly used method of preventing fire in the event of tube rupture in fired heaters is piping steam or CO2 as a snuffer into the combustion chamber of the heater. Usually a properly-sized line with a remote manual valve for activation is the preferred arrangement. This snuffer system can be automated by the use of an exhaust stack temperature switch. This switch would then energize a solenoid valve and alarm upon excessive temperature rise, automatically flooding the chamber with a fire extinguishing agent.
In practice the temperature switch is often set about 40 C (100 *F) over the normal exhaust temperature to prevent nuisance shutdowns. Where steam snuffer systems are used, it is a good idea to employ a steam trap to avoid slugging the combustion chamber with water when the system activates, or is activated manually.
Safety controls
In addition to activating controls, the system must also be fitted with the proper safety devices to meet the local code requirements. Safety controls should include:
(A) H igh temperature cutoff at the heater outlet,.. to shut off the burner in the event of an excessive temperature rise.
(B) Heater low flow cutoff ... to shut down the burner, should flow rate drop below design rates, or if a loss of flow occurs due to pump malfunction or failure.
Burners should be equipped with regular automatic ignition controls and flame failure controls. In wide-range firing, an over-fire draft control will save heat losses. Electric power failure and instrument air failure safety controls are 8lso desirable. In general, a policy of "fail-safe" instrumentation and control in the designing is essential, using good quality indicating - and recording gauges, with accuratereading scales calibrated for the particular limits of operation.
(C) Expansion tank low level switch ... to shut off the heater in the event of accidental fluid loss.
system 1
the basic system
The transfer of process heat as a liquid offers these benefits to the installation:
Precise heating levels
Closer temperature control at each user station Minimum cost installations Greater operating safety Low maintenance costs
Therminol systems are characterized by their extreme flexibility. A single heater can serve multiple "users" operating at the same or different temperature levels. The systems can be devised to deliver and to remove heat. Since the heat transfer is done with a liquid, there are no problems of condensation, pressure drop, and great heat surges.
The following diagrams illustrate the basic features of the heater off-take connections and the various arrangements of heat users that can be operated on Therminol fluids
This is the basic system configuration with a single user operating at heater outlet temperature Note: The 3-way valve diverts the unused Therminol directly back to the heater. This assures that a minimum flow will be maintained through the heater at all times. This also controls user temperature by regulating the flow of hot Therminol. This system has maximum temperature flexibility. User temperature may also be controlled by regulating the fuel supply to the heater. This method has a very limited turndown and should only be used with a continuous process with small load changes. Again, a minimum flow of Therminol must be maintained in the heater at all times.
. . 0616089
, I
TOWOLDMONOQ39435
system 2
Heating multiple users
The same system as No. 1 except several heat users are connected to the heater, all operating at the same temperature. To control temperature each user has a modulating control valve. A single minimum flow by-pass valve is used at the end of the piping loop.
An alternate method is to use a 3-way valve at every user. This usually costs more and requires additional piping. There is also a danger of starving the other users when one user is in complete by-pass.
i
0616090 14
TOWOLDMONOQ39436
' system 3
Heating several users at different temperatures
With this arrangement several heat users at different
temperatures may be operated at one time. Each temperature
zone has its own recirculating pump located at the user inlet with the temperature control valve located down stream of the user. A by-pass from the zone pump inlet is connected to the user outlet. When the temperature control valve is opened fresh high temperature Thermino! is
admitted to the zone where it is mixed and recirculated. This blending of hot and cold Therm/no/ gives precise
temperature control at some temperature below heater
outlet temperature.
This same principle can be used with System No. 1 when
the user has a very large fluid volume and small heat load.
The main recirculating pump is sized for the heat load
through the heater; while the zone pump is sized to recirculate a larger volume of blended Therminol through
the user.
Both of these arrangements will give excellent temperature control as well as a fast response to system change.
V
;
;
; j -: .i j ; ![ ,i
0616091
15
TOWOLDMONOQ39437
t
* system 4
Heating and cooling of a single user
This is a dual system for heating and cooling. For heating the user is connected in a similar way to the arrangement j in System 1, with the exception of the two additional 3-way j valves. These valves are used to establish two separate circulating systems with a common user. The zone pump ; is used on the cold side only. This arrangement operates l with a minimum of interchange between the hot and cold Therminolax cycle changeover. | Uses for this system are: s Batch type kettles to reduce turn around time. Start-up of f an exothermic reaction, followed by reaction temperature . control.
#
6i6092 16
TOWOLDMONOQ39438
&y;t ;5
Suggested start-up procedure for new systems
For a new system or one that returns to service after draining, the following check points are recommended as guides. They are supplemental to the heater manufacturers' and the heat-user processing equipment makers' recommendations and apply generally to the care of the fluid in all sizes and types of systems:
1. Check Safety and Control Devices
. . . for proper installation and functioning, making sure that the range settings are proper for the operation. Manually activate the instruments and apply all tests necessary to assure proper functioning. For protection of the system and for the expected long service life of the fluid it is vitally important that all instruments and controls function properly.
2. Check for leakage
3. Remove moisture from the system, using dry compressed air.
4. Fill the System with Thermino/
A Fill the expansion tank with Therminol, and introduce the fluid slowly into the system through the expansion tank valve until the tank is almost empty. Close the valve and again fill the tank. Open the valve allowing the fluid to enter the system and repeat until it no longer flows by gravity.
B Open all valves then start the main circulating pump in accordance with the manufacturer's recommendations. Observe the liquid level in the expansion tank, refilling as necessary until the system has been filled. Allow for the thermal expansion of Therminol in determining the cold charge level. The expansion tank should be adjusted to 70-75% full when the hot operating temperature is reached.
C Circulate the Therminol fluid through the system for about 3 to 4 hours to eliminate air pockets and to assure complete fill of the system. Before firing heater, be sure that Therminol is circulating freely.
5. Start the Heater
A Bring the system up to temperature slowly - about 35 C (95 *F) per hour. This will prevent thermal shock to heater tubes, tube/heater joints, refractory materials, etc___and allow operators to check the functioning of instruments and controls. The slow heat-up will also allow any moisture trapped in the system to escape as a vapour. B Bring System to operating temperature and put the "users" on the line. C The fluid is generally analysed within 24 hours of plant start-up and every 3 months during the first year of operation.
D Check the filter. As foreign material collects, the filter should be periodically removed and cleaned. After several days of operation with no foreign material on the screen - it may be permanently removed. The system should be heated and cooled for at least two cycles with the screen in place since the resulting expansion and contraction will loosen mill scale.
0616093
Hf M
TOWOLDMONOQ39439
OPERATING INSTRUCTIONS
Suggested operating instructions for liquid phase heating systems using Therminol fluids
The following operating suggestions are not intended to supersede or preclude those operating instructions provided by a heater or system supplier.
1, Check Safety Controls
In addition to activating controls, the heater should also be fitted with the proper safety controls to meet local code requirements.
2. Start-Up Temperature Precautions
a) Temperature of fluid at start-up is important: Consult your heater or pump supplier for the minimum recommended start-up temperature. This should correspond with the maximum permitted fluid viscosity. Failure to comply with their recommendations may lead to equipment damage.
b) If you have to start-up at low temperatures (below those specified), the fluid should be heated in a safe way, for example with electric tapes etc....
c) One way of avoiding start-up temperature problems is to keep the system idling at 105 C (221 F) especially in cold weather.
3. Procedure for Start-Up (cold fluid)
a) When the start-up temperature is O.K., start the circulating pump and check the expansion tank level to see that the Therminol is at the proper cold-start level (% full).
b) Start burner at the "low" flame setting and continue full circulation until the 7V?em?/7?o/bulk temperature reaches 105 C(221F).
c) Turn heater to full heat.
#>
4. Procedure for Start-Up (hot fluid)
Start-up after an automatic shut-down by the safety controls - (fluid should still be above 105 *C (221 *F). a) Run the circulating pump for ten minutes or so to
eliminate any vapor pockets formed when the fluid has remained static in the heater.
b) When flame is stabilized, the heater can be turned to full fire.
5. Procedure for shut-down
a) Shut off burner completely with circulating pump still operating. Continue to run the pump at full capacity for at least one hour to dissipate residual heat in the heater.
e
0616094 IB
TOWOLDMONOQ39440
b) Shut off circulating pump after one hour and switch off all heater electrical controls.
. r i^
v-
6. Planned maintenance
Regular maintenance inspection schedules should include the manufacturers' recommendations for the heater and the components as well as inspection of the Therminol fluid. The following is a list of inspection check points:
a) Lubrication of moving parts
b) Operating fidelity and the accuracy of the readings of safety controls and temperature limit controls.
c) Inspection of heater tubes, burner, refractory linings.
d) Periodic inspection of heater service. e) Inspection of the water cooling at the circulating pump.
f) Re-packing of stuffing boxes (according to the manufacturers specification).
g) Inspection of the expansion tank venting system.
h) The fluid should be analysed within 24 hours of plant start-up and every three months during the first year of operation. Afterwards, six-month checks are usually sufficient. Monsanto provides analytical procedures for sample testing and will advise on request the corrective action required should results be outside acceptable values for used fluid.
f
Safe handling and disposal
Both animal toxicity studies and manufacturing experience indicate that no special precautions are required in the handling of these products at ambient temperatures. However, it is suggested that good industrial practice relating to the avoidance of repeated and prolonged skin contact to any industrial chemical, heat transfer fluids, or petroleum product be followed. Vapors on the other hand while not dangerously toxic normally can give rise to discomfort; systems should be made as leak tight as possible.
Repairs to leaks of hot fluid should be carried out under well ventilated conditions.
More data is available on each product if required.
While it is believed that Therminol heat transfer fluids pose no serious problems with respect to the environment, as a concerned supplier to industry, Monsanto urges the user to maintain a tight system, to correct leakage promptly, and to excercise care in the handling and disposal of this and all other such products. A tight maintenance program not only protects the environment, but keeps employes comfortable, the working area clean snd the system running smoothly.
Important caution
Heat transfer fluids are intended only for indirect heating purposes. Under no circumstances should Therminol heat transfer fluids contact or in any way contaminate food, animal feed, food products, food packaging materials, pharmaceuticals or any items which may directly or indirectly be ultimately ingested by humans. Any contact may contaminate these items to the extent that their destruction may be required. Precautions against ignitions and fires should be taken with these products.
\
0
0616095
19
TOWOLDMONOQ39441
Resistance of valves and fittings to flow of fluids
A simple way to account for the resistance offered to flow by valves and fittings is to add to the length of pipe in the line a length which will give a pressure drop equal to that which occurs in the valves
if and fittings in the line.
if E Example: The dotted line shows that 3000 the resistance of a 6-inch Standard Elbow is equivalent to approximately 16 feet of 2000 6-inch Standard Steel Pipe.
Uiooo
r 500
- 300 - 200 . tUL--LJl -100 I uT _ Q. - L - 50
f- 50
#
l 0.5 0.3
E0.2
h 0.1
061609b 20
TOWOLDMONOQ39442
Steel pipe dimensions--capacities and weights*
Nominal Pipe
Size. in.
Outside Diam.,
Schedule No.
Wall Thickness,
In.
Vfe 0.405 40 0.068 80 .095
V< 0.540
40 80
.088 .119
0.675 V/ 0.840 14 1.050
1.315
40 80
40 80 160
40 80 160
40 80 160
.091 .126
.109 .147 .167
.113 .154 .218
.133 .179 250
Va 1.660 1 V? 1.900 2 2.375 ?''? 2.875 3 3.500 3V? 4.000 4 4.500
5 5.563
6 6.625
6 8625
40 80 160
40 80 160
40 80 160
40 80 160
40 80 160
40 80
40 80 120 160
40 80 120 160
40 80 120 160
20 30 40 60 80 100 120 140 160
.140 .191 .250
.145 .200 .281
.154 .218 .343
.203 .276 .375
.216 .300 .437
.226 .318
.237 .337 .437 .531
.258 .375 .500 .625
.280 .432 .562 .718
.250 .277 .322 .406 .500 .593 .718 .812 .906
Inside Diam.,
in.
0.269 .215
.364 .302
.493 .423
.622 .546 .466
.824 .742 .614
1.049 0.957 0.815
1.380 1.278 1.160
1.610 1.500 1.338
2.067 1.939 1.689
2.469 2.323 2.125
3.068 2.900 2.626
3.548 3.364
4.026 3.826 3626 3.438
5.047 4.813 4.563 4.313
6.065 5.761 5.501 5.189
8.125 8.071 7.981 7.813 7.625 7 439 7.189 7.001 6.813
Cross Sectional
Area Metal, sq. in.
Inside Sectional
Area, sq. ft.
Circumference, ft., or Surface
sq ft. per ft. of Lenoth
Outside
ln$ide
Capacity 8t 1 ft. Per Sec. Velocity
ITS-- Gal. Per Lb. Per Hr.
Min.
Water
' 0.072 .093
0.00040 .00025
0.106 .106
0075 .0563
0.179 .112
69.5 56.0
.125 .157
.00072 .00050
.141 .141
.0954 .0792
.323 .224
161.5 112.0
.167 .217
.250 .320 .384
.00133 .00098
.00211 .00163 .00118
.177 .177
.220 .220 .220
.1293 .1110
.1630 .1430 .1220
.596 .440
.945 .730 .529
298 0 220.0
472.5 365.0 264.5
.333 .433 .570
.494 .639 .837
.00371 .00300 .00206
.00600 .00499 .00362
.275 .275 .275
.344 .344 .344
.2158 .1942 .1610
.2745 .2505 .2135
1.665 1.345 0.924
2.690 2.240 1.625
832.5 672.5 462.0
1,345.0 1,120.0
812.5
.669 .881 1.107
.01040
.00891 .00734
.435 .435 .435
.362 .335 .304
4.57 3.99 3.29
2,285.0 1,995 0 1,645.0
0.799 1.068 1.429
.01414 .01225 .00976
.498 .498 .498
.422
.393 .350
6.34 5.49 4.38
3.170.0 2,745.0 2,190.0
1.075 1.477 2.190
.02330 .02050 .01556
.622 .622 .622
.542 .508 .442
10.45 9.20 6.97
5.225.0 4,600.0 3,4850
1.704 2.254 2.945
.03322 .02942 .02463
.753 .753 .753
.647
.609 .557
14.92 13.20 11.07
7,460.0 6,600.0 5,535.0
2228 3.016 4.205
.05130 .04587 .03761
.917 .917 .917
.804 .760 .688
23.00 20.55 16.90
11.500.0 10,275.0
8,450.0
2.680 3.678
.06870 .06170
1.047 1.047
.930 .882
30.80 27.70
15.400.0 13.850 0
3.173 4.407 5.578 6.621
.08840 .07986
.07170 .06447
1.178 1.178 1.178 1.178
1.055 1.002 0.950 0901
396 35.8 32.2 28.9
19,800.0 17,900.0 16,100.0 14,4500
4.304 6.112
7.953 9.696
.1390 .1263 .1136 .1015
1.456 1.456 1.456 1.456
1.322 1.263 1.197 1.132
62 3 57.7 51.0 45.5
31.150.0 28,850.0 25,500.0 22,750.0
5.584 8.405 10.71 13.32
6.570 7.260 8.396 10.48 12.76 14.96 17.84 19.93 21.97
.2006 .1810 .1650 .1469
.3601 .3553 .3474 .3329 .3171 .3016 .2819 .2673 .2532
1.734 1.734 1.734 1.734
2.258 2.258 2 258 2.258 2.258 2.258 2.258 2.258 2258
1.590 1.510 1.445 1.360
2130 2.115 2.090 2.050 2.000 1.947 1.883 1.835 1.787
90.0 81.1 73.9 65.8
161.5 159.4 155.7 149.4 142.3 135.3 126.5 120.0 113.5
45.000.0 40,500.0 36.950.0 32.900 0
80.750 0 79.700 0 77,850.0 74,700.0 71.1500 67.650.0 63.250.0 60,000.0 56,750.0
Weight of Pipe Per Ft.,
Lb
0.25 .32
.43 .54
.5? .74
.85 1.09 1.31
1.13 1.48 1.94
1.68 2.17 2.85
2.28 3.00 3.77
272 3 64 4.86
3.66 5.03 7.45
580 7.67 10.0
7.58 10.3 14.3
9.11 125
10.8 15.0 19.0 22 6
14.7 20.8 27.1 33.0
19.0 28 6 36 4 45.3
22 4 24.7 28 6 35.7 434 50.9 60.7 67.8 74.7
* Based or\ A.S.A. Standards 836.10.
. * r*., ~
061609/
TOWOLDMONOQ39443
Average properties of tubes
I
DIAMETER
THICKNESS
Externa! Internal Inches Inches
0 527 ** 0 495
0 459
0 652 0 620 0 584 0.560
0 902 0 670 0 834 0810
1 152 1.120 17. 1 084 1 060 1 032
1 402 1 370 iy? 1 334
1.282
1 620
iJ/< 1 560 1 532
1 870 1 834 2 1 782 1 760
BWG Gauge
18 16 14
18 16 14 13
18 16 14 13
18 16 14 13 12
18 16 14 13 12
16 14 13
1112
16 14 13 12 11
NOM Wall
0.049 0 065 0 083
0 049 0 065 0 083 0.095
0 049 0 065 0 083 0 095
0 049 0 065 0 083 0 095 0 109
0 049 0 065 0 083 0 095 0 109
0 065 0 083 0 095 0 109 0 120
0 065 0 083 0 095 0 109 0 120
EXTERNAL
Circumference Inches
1 9635
Surface Per
Lineal Foot Square Feet
0.1636
2 3562
0.1963
3 1416
0 2618
3 9270
0 3272
4 7124
0 3927
5 4978
0.4581
6 2832
0 5236
Lineal Feet of Tube Per Square Foot of Surface
Transverse Area
Square Inches
6.1115
0.218 0.193 0.166
5.0930 3.8197
0.334 0.302 0.268 0.246
0.639 0 595 0.546 0.515
3 0558
1.075 0 985 0 923 0 882 0.836
2 5465
1.544 1.474
1.398 1.343 1 292
2 1827
2.061 1 971
1.911 1.843 1.744
1.9099
2 746 2.642 2 573 2.489 2 433
INTERNAL
VOLUME OR CAPACITY PER LINEAL FOOT
Cubic Inches
2.616 2.316 1.992
4.008 3.624 3216 2.952
7.668 7.140 6 552 6.180
12.90 11.82 11.08 10.58 10.03
18 53 17.69 1678 16 12 15 50
24.73 23.65 22 94 22.12 2092
32.96 31.70 30.88 2987 29.20
Cubic Feel Also Area in
Square Feet
0.0015 0.0013 0.0011
0.0023 0.0021 0.0019 0.0017
00044 0.0041 0.0038 0.0036
0.0075 0.0068 0.0064 0.0061 0.0058
0.0107 0.0102 0.0097 0.0093 0.0090
00143 0.0137 0.0133 0.0128 0.0121
0.0191 0.0183 0.0179 0.0173 0.0169
United States Gallons
0 011 0.010 0.009
0.017 0.016 0.014 0.013
0033 0.031 0028 0.027
0.056 0051 0048 0.046 0.043
0.080 0076 0.073 0.070 0067
0.107 0.102 0.099 0.096 0.090
0.143 0.137 0.134 0.129 0.126
Length of Tube
Containing
One Cubic Foot
661 746 867
431 477 537 585
225 242 264 280
134 146 156 163 172
93 98 103 107 111
70
78 83
52 55 56 58 59
X
22
..........
0616098
TOWOLDMONOQ39444
Engineering conversion factors
Multiply
atmospheres atmospheres atmospheres atmospheres
British thermal units British thermal units Btu hr. Btu '(hr. sq. ft.0 F.)
Btu /hr. sq. ft.0 F.) (Btu/'hr. sq. ft.)/( F./in.)
(Btu ;hr. sq. ft.) ^( F. /ft.)
(Btu/hr. sq. ft.)/( F./ft.)
Blu/lb. F. Btu ^sec. Btu /sec. Btu/sec. Btu/sec, Btu/sq. ft. Btu/sq. (1.
centimeters centimeters cm. Hg. cm. Hg. cm. Hg. cm. Hg. cm. Hg. cm. Hg. cm./0 C. cm./sec. cm./sec. cm, /sec. cm./sec. cm./sec.
centipoises cubic centimeters cubic centimeters cubic centimeters cm.Vsec. cm.Vsec. cm.Vsec, cm.Vsec. cm.Vgrani cm.Vgram mol.
cubic feet cubic feet cubic feet
ft. of water ft. of water ft./min.
gallons (imperial) gal. (U.S.) gal. (U.S.) gal. (U.S.) gal./hr. gal./min. gal./min. gal./min. gal./min. of water
grams gram-cal. gram-cal./gram gram-cal./gram mol.
By To Obtain
14.70 lb. 'sq. in. 760 mm. Hg. 29.92 in. Hg. 33.90 ft. of water
3.930 x 10-4 2.930 x 10-4
3.927 x 10-4
1.356 k 10-4
hp. hr. kw, hr.
hp.
gram-cal./sec. cm.2 0 C.
2.035 x 10-3 watts /sq. in.0 F.
3,445 x 10-4 (gram-cal.'sec.
cm.2)/( C./cm.)
0.0173
(watts /cm,2) /-
14.88
1.0 778.2 1.4147 1.0549
( C. /cm.) (gram-cal./hr. cm.2)
/( C./cm.)
gram-cal./gram C.
ft. lb./sec. hp. kw,
107.6 0.2712 2.712
kg.-meter/sec. gram-cal. cm2 kg.-cal.'sq. meter
0.3937 0.0328
in. ft.
0.01316 0.1934 27.85 136.0 5.353
0.4461 0.2187 1.969
0.03281 0.036 0.60 0.02237
atm.
Ib./sq. in. Ib./sq, ft. kg./sq, meter in, of water ft. of water in. 0 F. ft. 'min. ft. sec. km. 'hr. meters /min. mph
2.42 0.06102
lb./ft. hr. cu. in.
3.531 * 10-' cu. ft.
2.642 x 10-4 gal.
2.119 xlO-3 cu. ft./min.
0.0864
cu. meter/day
0.01585 3.6
gal./min. liter/hr.
0.01602 0.01602
cu. ft. lb. cu. ft./lb. mol.
7.481 gal. 28.32 liters 62.43 lb. of water
62.43 0.4335
Ib./sq. ft. lb. 'sq. in.
0.508 cm. sec.
1.201 231 3785 3.785 3.71 x 10~s
2.228 xlO-3 0.227 0,06309
gal. (U.S.) cu. in. cm.3
liters
cu, ft./sec, cu. ft./sec, cu. meters/hr.
liters/sec.
500.8 lb./hr. of water
2.205 x 10-3 lb.
3.968 x 10'3 Btu 1.8 Btu/lb.
1.8 Btu/lb. mol.
Multiply
gram-cal./gram 0 C. (gram-cal. 'sec. cm.2)/( C./cm.)
hp. (boiler) hp. (boiler) hp. hr. hp. hr.
inches in. Hg. in. Hg. in. Hg. in. of water in. of water
kg./cu. meter
kilowatts kw. hr. kw. hr.
liters liters liters/min.
meters meters meters/sec, meters/sec.
ounces
poises pounds lb. of water lb. of water lb./ft. hr. lb./gal. Ib./sq. ft. Ib./sq. ft. Ib./sq. in. Ib./sq. in. Ib./sq. in. Ib./sq. in. Ib./sq. in.
refrigeration--std. ton square centimeters square centimeters square feet square feet square feet square inches square inches square inches square meters
temperature 0 C. 273 temperature 0 C. 17.8 temperature 0 F. 460 temperature 0 F. --32
tons (long) tons (long) tons (metric) tons (short) tons (short)
watts watts watts watt hours
week week week years (common)
By To Obtain
1.0 Btu /lb. 0 F. 2.903 x 103 (Btu/hr. sq. ft,)/-
( F./in.t
3.3479 x 104 Btu/hr.
9.804 kw.
2.545 x 103 Btu
0.7457
kw. hr.
2,54 0.03342
1.133 0.4912 2,458 x 10-3
0.07355
cm.
atm.
ft. of water Ib./sq. in. atm.
in. Hg.
0.06243
Ib./cu. ft.
1.341 hp. 3.413 x 10= Btu 1.341 hp. hr.
0.2642 1.057
15.851
gal. (U.S.) qt. (liq.)
gal./hr.
3.281 ft. 39.37 in. 196.8 ft./min. 2.237 mph
28.35 grams
1
453.6 0,01602 0.1198 0.413 0.1198 0.01602 4.882 0,06804 2.307 2.036 51.7
703.1
gram/cm. sec. grams cu. ft. gal.
centipoises grams/cm.3 ft. of water kg./sq, meter atm. ft, of water in. Hg. mm, Hg.
kg. sq. meter
200 1.076 x 10-3 0.1550 929 144 0.0929 6.452 6.944 x 10-3 6.452 x 10'4 10.76
Btu 'min. sq. ft. sq. in. sq. cm. sq. in, sq. meters cm.2 sq. ft. sq. meters sq. ft.
1.0 1.8 1.0 0.5555
abs. temp.0 K. temp, 0 F.
abs. temp. 0 R.
temp.0 C.
1.016x10= 2.24 x 103 2.205 x 103 907.2 2 xlO3
kg. lb.
lb. kg.
lb.
0.05692
Btu/min.
44.26 ft. Ib./min.
1.341 x lO"3 hp.
3,413 Btu
168 1.008 x 104 6.048 x 105
8.76 x 10=
hr. min. sec. hr.
0616099
TOWOLDMONOQ39445
Viscosity conversion
Read horizontally across chart to convert readings. Multiply readings in centistokes by specific gravity to obtain absolute viscosity in centipoises.
<
KINEMATIC
REDWOOD
ENGLER
SAYBOLT
kinematic
ij g ;
W !1 g a p
w n a w w g w w i'P
TOWOLDMONOQ39446
Thermino) 66 IC/FF-66
F. Max. Film 700------------- Temp.
(r I f I
i
650 Max. Bulk i
600 i
I
550
500
450 400
350 300
250 200 150
100 50
0
Pour
Point -15 F.
... wide-range liquid phase heat transfer fluid for non-pressurized indirect heating to 650 F.
Heat transfer fluids are intended only for indirect heating purposes. Under no circumstances should this product contact or in any way contaminate food, animal feed, food products, food packaging materials, pharmaceu ticals or any items which may directly or indirectly be ultimately ingested by humans. Any contact may con taminate these items to the extent that their destruction may be required. Precautions against ignitions and fires should be taken with this product.
Monsanto
"Nothing contained herein is to be construed as a recommendation to
use any product in conflict with any patent. MONSANTO MAKES NO WARRANTIES AS TO THE FITNESS OR MERCHANTABILITY OF ANY PRODUCT REFERRED TO. no guarantee of satisfactory results from reliance upon contained information or recommendations, and disclaims all liability for any resulting loss or damage."
FUNCTIONAL PRODUCTS/Monsanto Industrial Chemicals Co. I
800 North Lindbergh Blvd., St. Louis, Missouri 63166
-
0616101
j
..........Tv-.
,
TOWOLDMONOQ39447
Therminol 66...
Typical Properties
is a high-performance synthetic heat transfer fluid offering low-temperature pumpability (0F.) along with outstanding high-temperature performance -- up to 650F. Therminol 66 is ideally suited to replace organic fluids which have lower boiling points and must operate under pressure at 650F.
This fluid is designed for use in non-pressurized in direct heating systems. It delivers efficient, depend able process heat with no need for high pressures, costly "extra" equipment, or continuous supervision.
Therminol 66 is not classified as a fire-resistant heat transfer fluid. Consequently, the use of protective devices may be required to minimize fire risk. The insurer of your property should be consulted relative to this matter.
To minimize fluid oxidation, Therminol 66 systems should be blanketed with an inert atmosphere. A system relief valve should also be provided.
Therminol 66 offers long service life within its recommended operating temperature range, and is non-corrosive to metals commonly used in the design of heat transfer systems.
Composition Appearance Odor Pour Point Density <& 75F. Flash Point
Fire Point AIT
Coefficient of Expansion Boiling Range:
10%" 90% Average Molecular Weight
Modified Terphenyl Oily liquid, practically colorless Faint, characteristic --18F. 8.35 Ibs./gal. 355F. 382F. 705F. 0.00070 cc/cc/C.
644F. 745F. 240
Variations of Properties With Temperature
Temper ature
F C 0 --18 50 10
100 38 150 66 200 93 250 121 300 149 350 177 400 204 450 232 500 260 550 288 600 316 650 343 700 371
Density
lbs. gel. 8.67 8.51 8.34 8.14 7.91 7.77 7.59 7.39 7.17 7.04 6.75 6.62 6.42 6.24 6.09
lb. /ft.3 64.9 63.6 62.4 60.9 59.3 58.0 56.8 55.2 53.6 52.5 50.5 49.5 48.1 46.8 45.6
Kg./m.3 1040 1020 1000 975 950 930 910 885 860 840 810 793 770 750 730
Specific Heat
BTU/lb. F
0.320 0.350 0.380 0.405 0.430 0.455 0.480 0.505 0.530 0.555 0.580 0.605 0.630
0.655 0.680
Kcal./Kg. C
0.320 0.350 0.380 0.405 0,430 0.455 0.480 0.505 0.530 0.555 0.580 0.605 0.630 0.655 0.680
Thermal Conductivity
BTU/ft. hr. F
0.0720 0.0711 0.0703 0.0695 0.0687 0.0678 0.0670 0.0662 0.0653 0.0645 0.0637 0.0628 0.0620 0.0613 0.0605
Kcal./m. hr. C
0.1072 0.1058 0.1046 0.1034 0.1022 0.1008 0.0997 0.0985 0.0972 0.0959 0.0948 0.0935 0.0923 0.0912 0.0900
Viscosity
lb./hr. ft. 150000
617 67.8 23.6 10.1 5.86 3.75 2.57 1.88 1.40 1.08 0.87 0.82 0.65 0.49
cs 50000
250 28.0 10.0 4.40 2.60 1.70 1.20 0.90 0.69 0.55 0.46 0.44 0.36 0.28
Vapor Prassure
mrnHg. absolute Kg./om.3
0.1
-
2.0
--
20.0 50.0 100.0 200.0 350.0 760.0 1000
-
-
0.003
-
0.027 0.068 0.136 0.272 0.476 1.034 1.360
'
0616102
J
TOWOLDMONOQ39448
Thermlnot 66-Physical Properties
t i
15 <o7> 8
10 >
Therminol 66-Heat Transfer Coefficients
Therminol 66--Pressure Drop
Therminol 66-Safety of Handling
Therminol 66 is virtually non-toxic and non-irritating, posing no special handling problems. It is not ab sorbed through the unbroken skin in significant quantities, is non-irritating to the skin and only mildly irritating if eye contact occurs. Immediate flushing of the eye with copious amounts of water will avoid irritation or after-effects. It is suggested that Therminol 66 be washed off the skin with soap and water as soon as possible after contact, but no serious irritation should be observed. Handled like any other industrial chemical, Therminol 66 is quite safe to store and use.
Therminol 66 vapors are not toxic, but may cause discomfort if coming off of heated fluid. There is no vapor exposure problem when transferring the fluid from its shipping container to the heat transfer system. On the other hand, vapors emitted by
Therminol 66 heated to elevated temperatures may be mildly irritating upon prolonged exposure. In heat transfer installations, the fluid is used in a closed, non-pressurized system free from leaks and with the expansion tank vent trapped so as to con dense any vapors. Consequently, there should be little or no opportunity for workers to come in contact with vapors.
While Therminol 66 poses no serious problems with respect to the environment, as a concerned supplier to industry, Monsanto urges the user to maintain a tight system, to correct leakage promptly, and to exercise care in the handling and disposal of this and all other such products. A tight maintenance program not only protects the environment, but keeps employes comfortable, the working area clean, and the system running smoothly.
I
OblblO*.
TOWOLDMONOQ39450
Interim Product Bulletin 12/72
DEVELOPMENTAL SYNTHETIC FLOWS
THERMINOL 44 Typical Physical Properties
Operating Range, F Appearance Odor Flash Point, C.O.C., F Fire Point, C.O.C., F A.I.T., F Pour Point, F Viscosity, cs
100 F 200F 300F 400F 500F Specific Oravity, g/cc -65 F
75F 100F 200F 300F 5oo#f
t
CO0 0
c0t 1
VO0 0
-60 to 425F Clear yellow liquid Faint 405 438 705
6450 8.80 2.70 1.30 0.85 0.57
0.980 0.920 0.915 0.845 0.825 0.780
MONSANTO COMPANY 800 NORTH LINDBERGH BLVD. ST. LOUIS, MO. 63166
TO ASSIST YOU IN THE EVALUATION Of THE MOVE MODOC!, WE HAVE OBTAINED THE INFORMATION CON TAINED IN THIS BULLETIN FROM LITERATURE IOURCES AND PRELIMINARY INVESTIGATION IN OUR OWN
LABORATORIES. WHILE WE BELIEVE THE INFORMATION IS ACCURATE, WE ASSUME NO RESPONSIBILITY AND DISCLAIM ANY LIABILITY INCURRED IN USING THESE DATA OR SUGGESTIONS. ONLY QUALIFIED TECHNICAL
PERSONNEL SHOULD WORK WITH THIS PRODUCT UNTIL SUBSEQUENT STUDIES JUSTIFY ITS USE IN YOUR PROD UCTS OR PROCESSES. OBVIOUSLY NOTHING IN THIS BULLETIN SHOULD BE CONSTRUED AS A aiCOMAEKOATION TO USE ANY PRODUCT IN CONFLICT WITH EXISTING PATENTS COVERING ANY MATERIAL OR ITS USE
0616105
TOWOLDMONOQ39451
THERMINOL 44
Page Two
Specific Heat, Btu/lb.-F 0F
100*P 200P 3008 P 400*F
0.443 0.476
0.508
0.542 0.574
Thermal Conductivity, Btu/hr.-ft."F 0P
100P 200P 300P 400F
0.0847 0.0806
0.0760 0.0710
0.0651
Vapor Pressure, mm Hg 300F 400* P 500P 600P 640F
<1.0 6.0
45.0
760.0
Toxicity
Thermlnol 44 Is classified as practically non-toxic based on acute oral and acute skin absorption studies on rats and rabbits.
This product Is classified as mild skin and eye Irritant.
This product Is classified as practically non-toxic In acute vapor Inhalation tests.
This product requires no special handling precautions nor should It present an environmental hazard.
Thermlnol 44 Is Intended for indirect heating purposes only. Under no circumstances should heat transfer fluids contact or In any way contaminate food, animal feed, food products, food packaging materials, pharmaceuticals or any food related items. Any such contact may contaminate these Items to the extent their destruction may be required.
0616106
TOWOLDMONOQ39452
Themninol 55 IC/FF-55
Max. Film Temp. 635F.
F. 600------------
Max. Bulk
... low-cost liquid phase heat transfer fluid for non-pressurized indirect heating to 600 F.
-50------------
Pour
Point -20F.
Heat transfer fluids are intended only for indirect heating purposes. Under no circumstances should this product contact or in any way contaminate food, animal feed, food products, food packaging materials, pharmaceu ticals or any items which may directly or indirectly be ultimately ingested by humans. Any contact may con taminate these items to the extent that their destruction may be required. Precautions against ignitions and fires should be taken with this product.
Monsanto
"Nothing contained herein is to be construed as a recommendation to use any product in conflict with any patent. MONSANTO MAKES NO WARRANTIES AS TO THE FITNESS OR MERCHANTABILITY OF ANY PRODUCT REFERRED TO, no guarantee of satisfactory results from reliance upon contained information or recommendations, and disclaims all liability for any resulting loss or damage.1'
FUNCTIONAL PRODUCTS/Monsanto Industrial Chemicals Co. 800 North Lindbergh Blvd., St. Louis, Missouri 63166
0616107
)
TOWOLDMONOQ39453
Thermlnot 55..
Typical Properties
is a low-cost synthetic heat transfer fluid offering low-temperature pumpability (0F.) as well as excel lent high temperature (575eF.) performance. Therminol 65 is not classified as a fire-resistant heat transfer fluid. Consequently, the use of protective devices may be required to minimize fire risk, The insurer of your property should be consulted relative to this matter.
This fluid is designed for use in non-pressurized indirect heating systems. It delivers efficient, depend able process heat with no need for high pressures, costly "extra" equipment, or continuous supervision.
Therminol 55 systems should be blanketed with an inert atmosphere to minimize fluid oxidation. This fluid offers excellent thermal stability and long service life, along with its wide operating tempera ture range.
Composition Appearance Odor Pour Point Density @ 75F. Flash Point
Fire Point AIT Coefficient of Expansion Boiling Range:
10% 90% Average Molecular Weight
Synthetic Hydrocarbon Mixture Clear brown liquid Slight, characteristic --40F. 7.40 Ibs./gal. 355F. min. 410F. 675F. 0.00085 cc/cc/C.
635F. 734F. 340
Variations of Properties With Temperature
Temper ature
F c 0 --18
100 38 200 93 300 149 400 204 500 260 600 316
Density
Ibs./gal. 7.62 7.31 7.00 6.69 6.39 6.07 5.76
Ib./tU 57.1 54.8 52.4 50.1 47.8 45.5 43.1
Kg./m.5 915 878 840 803 766 729
691
Specific Heat
BTU/lb. F
0.420
0.472 0.522
0.572 0.620
0.670
0.718
Keal./Kg. C
0.420 0.472 0.522
0.572
0.620
0.670
0.718
Thermal Conductivity
BTU/ft hr. F
0.0813 0.0784 0.0753 0.0724
0.0692
0.0661
0.0630
Kcal./m. hr. C
0.1210 0.1167
0.1121 0.1077 0.1030 0.0984
0.0938
Viscosity
Ib./hr. ft. 3561 61.5 10.3 4.09 2.18 1.41 1.01
cs 1610 30.1 5.0 2.10
1.18 0.80 0.60
Vapor Pressure
mmHg. absolute
0.5 3.0 10
40 100
250
Kg./cm.2 -
0.001 0.004 0.014 0.054 0.136 0.330
0616108
TOWOLDMONOQ39454
SPECIFIC HEAT -- Btu/Lb.
Therminol 55-Physical Properties
40
35
20 o I
-50 0
100 200 300 400 500 600 TEMPERATURE -- F.
Therminol 55-Heat Transfer Coefficients
TOWOLDMONOQ39455
I Thermlnol 55--Pressure Drop
Thermlnol 55-Safety of Handling
Therminol 55 is virtually non-toxic and non-irritating, Therminol 55 heated to elevated temperatures may
posing no special handling problems. It is not ab be mildly irritating upon prolonged exposure. In
sorbed through the unbroken skin in significant heat transfer installations, the fluid is used in a
quantities, is non-irritating to the skin and only closed, unpressurized system free from leaks and
mildly irritating if eye contact occurs. Immediate with the expansion tank vent trapped so as to con
flushing of the eye with copious amounts of water dense any vapors, Consequently, there should be
will avoid irritation or after-effects. It is suggested little or no opportunity for workers to come in
that Therminol 55 be washed off the skin with soap contact with vapors.
and water as soon as possible after contact, but no
While Therminol 55 poses no serious problems with
I
serious irritation should be observed, Handled like respect to the environment, as a concerned supplier any other industrial chemical, Therminol 55 is quite to industry, Monsanto urges the user to maintain a
i safe to store and use.
tight system, to correct leakage promptly, and to
Therminol 55 vapors are not toxic, but may cause exercise care in the handling and disposal of this
discomfort if coming off of heated fluid. There is no and all other such products. A tight maintenance
vapor exposure problem when transferring the fluid program not only protects the environment, but
from its shipping container to the heat transfer keeps employes comfortable, the working area
system. On the other hand, vapors emitted by clean, and the system running smoothly.
%
|'
06X6110
TOWOLDMONOQ39456
DSVeLQPMBNTAL S YNTl-H- TIC FLUIDS
THERMIHOL 60 . Typical Physical Properties .
Operating Range, F
Appearance
Odor
,
Plash Point, C.O.C., P
Fire'Point, C.O.C., P
A.I.T., P ,
Pour Point, 8P
Viscosity, os -65F 100 P 200P 300P 500P 500F
Specific Oravlty, g/co -65P 75P 100P 200P 300 P 5oo#p
-60 to 600#F
Clear liquid
Paint
310
320
835 -80 to -90
3850
4.90
1.75 0.97 0.62 0.46
1.02 0.998 0.985 0.926 0.910 0.875
MONSANTO COMPANY 800 NORTH LINDBERGH BlVD. ST. LOUIS. MO. 63166
to All'll 0U IN tH( rVMUMlON Of TKt AtCYI MOOUCT. KAYt OHATMO tHf IMIONMATlON CON tAIAU> IN THIS feULlffIN INCH IITINAtl'*! UelNItl A\3 IMIIVimNV IN/IHIL*1iCN IN Out OWN
HICAIU<'ll WHIll *( Ilnur 1H[ lMO*6HlON l| ACCI'MII. HI liCui/t NO NiirtNMiuiii* no
0">UAlV INr Hill',ITT HtfuRPlO IN Ot'NS lll,l pill ON l,i*',| JllCNt ONIT QU*lllll0 TtliHUl Nl*{ONN(l IMOulp NONA VYI1H Ifl! NhbPVCI HIM lfi;i CJlNt St_( I, (UlllfV IH I'M IN TCU PISS
0616111
TOWOLDMONOQ39457
Therminol 6p
-2- Typical Physical Properties
Specific Heat, Btu/lb.-F 100"F 200 F 300 F 400 F
0.450 0.58a
Thermal Conductivity, BTU/hr-ft.F** 100F
0.700
Vapor Pressure, mm HQ
300F
400 F
500F
.
600F
640P
12
60
.250
760
`
Extrapolated - Additional data being obtained. Additional data being obtained.
Toxicity Therminol 60 Is classified as practically non-toxic based on acute oral and acute skin absorption studies on rats and rabbits. These products are classified as mild skin and eye Irri tants, These products are classified as practically non-toxic in acute vapor inhalation tests. These products require no special handling precautions nor should they present an environmental hazard. Therminol 60 is intended for indirect heating purposes only. Under no circumstances should heat transfer fluids contact or in any way contaminate food, animal feed, food products, food packaging materials, pharmaceuticals or any food re lated items. Any such contact may contaminate these items to the extent their destruction may be required. .
TOWOLDMONOQ39458
THERMINOL 88 HIGH TEMPERATURE HEAT TRANSFER FLUID ...for use in liquid phase between 300 and 800F
TYPICAL PROPERTIES OF THERMINOL* 88
Composition Appearanoe
Color Odor Melt Point
begins to soften completely liquid Flash Point Flame Point Autolgnltlon Temperature Coefficient of Expansion Latent Heat of Fusion Molecular Weight Bolling Range
Mixed terphenyls Crumbly wax-like flakes at room temperature. Light amber liquid above Melt Point. Yellow to light amber Faint, pleasant
140F (60C) 293F (145C) 375#F (191C) 460F (238 C)
>1000*P
0.00047 cc/cc/F 5.0-5.1 K Cal/mole 230 687-784f (364#-4l8c)
Yh IMt>m*<** WMtwtM > thM MKtin n. M MW kss|
Us* Mtf StMTMt. M HMSSaMMMttlSftl
wilMlest .> mtt* vitAwt *'*(.
ft* rnnmtm ifwm knee* ew ssrtfsl. The MmssMs
C*swm
*/ ikvh m we*nlIs* vN* ft* ms f ft*** Art* imanUsm. ferft*nwr*
mimi sssisism **<* eMii ks mmm* a a mmmmmrn la*mm m+* la a*** wm nm**
NWl **** **> MMMlalM m m*.
06I6H3
TOWOLDMONOQ39459
PHYSICAL PROPERTIES - THERMINOL 88
Density Temp,*P Rm/cc
77 1.133 200 300 1.01 4oo 0.96 500 0.92 600 0.88 700 0.83 800 0.7? 900 0.74
Kinematic Vlsooslty
os
Specific Heat
BTU/# *P
Thermal Conductivity HTU/hr-ft-P
Vapor Pressure
mm Hg
1.57 0.87
0.55 0.38 0.29
0.23
0.19
0.467
0.497 0.525 0.554 0.584
0.613 0.642
0.0738 0.0712 0.0686 0.0660 0.0634 0.0608
0.0581
1.2 11
65 260
800 1500 3000
THERMAL DECOMPOSITION Temperature, #P
<f> Polymerlzed/Hr.
700 O.OOOO65 660 0.0048 900 0.32
Therminol 88 is usable with as much as 30* polymer content whioh affect properties as follows:
Melt Point Plash & Flame Point,AIT Speolflo Oravity Viscosity Speolflo Heat Thermal Conductivity
293 to 276P No appreciable change + 7* at 800#P +35* at 800P
- i% at 800P
-13* at 800P
0616114
TOWOLDMONOQ39460
TOWOLDMON0039461
MONSANTO COMPANY
H lA l lR A N i tK t-A(,IO K.`
THERMINOL 88 Heat Transfer Correlation This equation and J-factor plot Is adequate to approximately plua/mlnua 7% and was developed for polyphenyla by A.I.
0616117
TOWOLDMONOQ39463
THERMINOL 88 Thermodynamic Diagram While we do not propose that Thermlnol 88 be used as a vapor phase heat transfer medium, we often are requested to provide a thermo dynamic network--which appears below.
TOWOLDMONOQ39464
TfMt>RATURt.
TYPICAL ELECTRICAL PROPERTIES THERMINOL 88
Dielectric Constant at 77F
2.58 at 60 cps
Volume Resistivity at 212#F at 275#F at 311F
140,000 x 109 ohm-cm. 35000 x 10^ ohm-cm 550 x 10^ ohm-cm
SOLUBILITY OF THERMINOL 88 IN MISCELLANEOUS SOLVENTS
Solvent
Grms.Thermlnol 88 per 100 ml.of solvent
25 C.
75 C.
i Fuel Oil, API 36, 18 S.U.S. t 100 F.............................................
Tntblorobenwne..................................................................................................... ! Stoddard's Solvent..................................................................................................
2-X'iiropropane....................................................................................... (Set also Fig,. 1 and 2.)
0.008 1.2 1.66 6.0 9.0
0.7
0.2 2.0 2.0
2.0
0.6 0.0
fi.4 42.0 4$ 0
60 7;
1S.0 ( 20 0 ; 200 1
_______ 1
4/fio
0616119
TOWOLDMONOQ39465
SOLUBILITY OP THERMINOL 88 IN' COMMON SOLVENTS
TOWOLDMONOQ39466
Therminol Heat Transfer Fluid Data Sheets
1 jRj
TOWOLDMONOQ39467
rX
CUSTOMER SERVICE CENTERS
AKRON, OHIO 44313 260 Springside Drive Montrose Development Park Tel. (216) 666-4111
ATLANTA, GEORGIA 30339 320 Interstate North Parkway Suite 500 Tel. (404)432-7111
BOSTON, MASSACHUSETTS 02149 Everett Station Tel. (617) 387-5010
CHICAGO, ILLINOIS 3158 Des Plaines Ave. Des Plaines, Illinois 60018 Tel. (312) 296-6688
CINCINNATI, OHIO 45206 1501 Madison Road Tel. (513) 751-6707
DETROIT, MICHIGAN 500 Northland Towers West Southfield, Michigan 48075 Tel. (313) 357-0910
HOUSTON, TEXAS 77027 1301 Post Oak Tower 5051 Westheimer Road Tel. (713) 621-9550
LOS ANGELES, CALIFORNIA 90022 6670 E. Flotilla St. Tel. (213) 723-2492
NEW YORK, NEW YORK 10036 1114 Avenue of the Americas Tal. (212) 764-5000
ST. LOUIS, MISSOURI 63166 800 N. Lindbergh Blvd. Tel. (314) 694-1000
SAN FRANCISCO BAY AREA 2710 Lafayette Santa Clara, California 95052 Tel. (408) 243-0414
SEATTLE, WASHINGTON 98121 2112 Third Avenue Tel. (206) 622-4203
WILMINGTON, DELAWARE 19810 Suite 204, Bancroft Bldg. 3411 Silverside Road Tel. (302) 478-4600
Monsanto Industrial Chemicals Co. A Unit of Monsanto Company 800 N. Lindbergh Blvd., St. Louis, Mo. 63166
Vw
:''.vava*..wsif
y
Monsanto
> i
Oblbltz
TOWOLDMONOQ39468