Document RaRqXRq6dgdBQpmB3DzX9r0Qz
RESEARCH & ENGINEERING DIVISION
The ^Estimation of Asbestos in Liquids
Introduction Since the original publication of the letter in Nature by Biles and Emerson who reported observing asbestos fibres in some beers, TBA Industrial Products Ltd has undertaken a programme of research to develop suitable electron microscopic techniques to quantity the asbestos, if any, in various liquid media. Using such techniques, a number of wines and beers have been analysed. Since then electron microscopy has been used by a number of workers. Cunningham and
2 Pontefract have reported their results on a number of beers, wines and water samples. Recently Nicholson, Maggiore and Selikoff^ have discussed their findings of asbestos in a few parenteral drugs.
Limit of detection of electron microscopic techniques In principle, a 1 p long single fibril fragment can be identified by its electron diffrae/ion pattern. However, a practicable lower limit of detection for asbestos in liquids was initially presumed to be about 100 fibrils per litre. Taking a typical fibril fragment to be about 1 ji long and 300.? in diameter, it would have a mass of
--15 -1 5 2 x 1 0 -g and 100 fibrils in a litre would be equivalent to 10 g/ litre. If a 1 5 ml sample of this liquid was taken it should contain only 1 or 2 fibrils. An electron microscopic specimen would therefore distribute the 1 or 2 fibrils on the 1000 grid squares. An analysis of such a distributioi/concentration would be statistically very unreliable, if indeed it was even practicable. In most such techniques a limited number of squares are examined, say five grid squares per specimen. If there was a probability of at least one fibril per square, then such a measurement ipay carry some weight. A concentration of 1 fibril per grid square from a 15 ml sample
--10 would be equivalent to about 60 000 fibrils per litre or 10 5/ litre. This represents a realistic limit of detection.
continued,
J s industrie p r o e m i
.id
R E S E A R C H & ENGINEERING DIVISION
- 2-
3 . Background levels It is obviously extremely important to ensure clean conditions during specimen preparation and examination, as contamination from the laboratory ware and the various analytical procedures could lead to very erroneous results. This is partly because in all electron microscopic techniques the ultimate sample examined is a minute fraction of the total sample and very large conversion factors are used to calculate the amount of asbestos actually present in the sample. Thus apy contamination to the electron microscopic specimen also gets multiplied by the same large conversion factors. Finally, f o r a given concentration, the larger the volume of the samples the larger the actual asbestos content of the sample, thus reducing the importa.nce of contamination in specimen preparation.
It is essential that background levels are measured on blanks at
the same time as test specimens. In the work reported here, blank --Q
samples have generally ranged from 10 ' g/litre to 10 g/litre.
The details of the election microscopic technique have been described 5
by Rickards and in Appendix 1 . Method A described in the appendix
was used for the beer and wine samples and method. B for the drug
samples.
4 . Samples The following samples were analysed: (a) Cans of one commercial British and one U. S. beer (b) Samples of test wines collected after differing amounts of wine had passed through the filters (c) Samples of initial water and final filtered beer collected from a brewery ( d) A sample of streptomycin sulphate obtained from a leading international pharmaceutical manufacturer (e) A series of samples simulating the manufacture of human blood protein.
continued,
/-T, '
ML. ...Ill liidustriai Products Ltd
R E S E A R C H & ENGINEERING DIVISION
5 * Results The chrysotile asbestos contents of these samples are shown in Tables I to V and are shofm in a scalar diagram in Pig 1 .
6. Discussion As mentioned in Section 3 it has been our experience that the most reliable approach is to constantly carry out blank tests, simultaneously with test specimens, and ensure that the differences observed between the two are statistically significant. In this respect it is a little surprising that Cunningham and Pontefract did not observe any asbestos fibres in their blank runs. Contamination is particularly erratic when the specimen preparation involves exposure to air, e.g. evaporation under a heat lamp (Cunningham and Pontefract) or when the nitro-cellulose film is allowed to dry (Nicholson et al).
The significance of the contamination also increases in importance as the size of the sample decreases. TEA used 15 ml samples in initial studies but now prefer to use 500 ml to 1000 ml samples. Cunningham and Pontefract used samples of 400 ml but Nicholson et al used only 1 ml. This perhaps would explain why even the background level claimed by Nicholson et al is higher than the results obtained by other investigations (Fig 1 ).
One of the striking features in Fig 1 is that the results quoted by the three sets of investigators fall into three distinct hands with no overlap between them. This is all the more surprising considering the wide range of samples examined by Cunningham and Pontefract. The results suggest that very broadly each set of workers have been measuring essentially the background level inherent in their techniques and laboratories. Because of the very small samples used by Nicholson et al, one might expect the contamination to be more significant and this is indeed the case, even their background level being higher than all the results reported by others. TEA have devoted considerable effort to ensure the statistical significance of the observed data and hence very low background
continued,
industrial Products Ltd
R E S E A R C H & ENGINEERING DIVISION
4-
levels
of
1 0-~8g/litre
to
1
9 7g/litre
have
been
achieved.
These are
~10 very close to the practicable limit of detection of 10 g/litro
referred to earlier. Cunningham and Pontefract appear to have
intermediate values in spite of their statement that their blank
runs contained no asbestos at all, i.e. they claimed their background
level as zero.
Allowing for the scatter of results it is, however, possible to
draw the following conclusions: (1) In the series of samples obtained from the brewery (Table III)
there is no evidence that the use of asbestos filters introduced any additional asbestos fibres. The same conclusion can also be reached from Cunningham and Pontefract1s results. (2) TEA examination, using 1000 ml samples of a drug, led to the lowest value recorded at TEA, a value 10 000 times less than that reported by Nicholson, Maggiore and Selikoff for a
similar drug. (3 ) When the last sample in the test series (Table II) had an
asbestos content of 10 ^g/litre, (comparable with levels reported by Nicholson et al for drugs) the electron microscope
fields of vievr were so crowded that nunerical counting was out of question. In fact an X-ray diffractometer was used to measure the amount of asbestos present by the technique
4 described by Rickards .
If therefore Nicholson et al1s results were truly representative,
then there should be sufficient asbestos in a litre of sample to give a strong X-ray diffraction pattern, since even 10 - 5 g oan be detected
5 by the TEA X-ray technique .
Conversely
if
10
--8 g
of
asbestos
were
actually
present
in
the^ 1
al
g
samples used by Nicholson et al,' it is equivalent to about 10 fibrils
of the size that they claim are present in these. (Since their
sample preparation involved actually grinding for 2 to 5 minutes
before analysis, the authors could not in fact have had any
information about the size distribution present in those actual samples). Por their electron microscopic examination, Nicholson
continued,
nr,
-
Industrial Products Ltd
RESEARCH & ENGINEERING DIVISION
' - 5-
'
et al used half the filter and hence this should have still 78
contained approximately 1Cr to 10 such fibrils (i.e. ten million to 100 million fibrils). The authors state that a known fraction of the air dried film was put in the electron microscope and two to four grid squares were examined. If, say, two squares contained 20 fibrils, then the film specimen on the grid would have about 20 x 200 fibrils, i.e. 4 x 10^ fibrils. If these calculations are justified, the implication is that only about one tenth thousandth of the air dried film was examined in the electron microscope. There is no suggestion in the paper that even a duplicate film specimen was examined.
On the basis of the data presented by Nicholson et al, it is impossible to state, with any scientific credibility that there "is an indication of significant asbestos contamination of some parenteral drugs at this time". On the other hand, investigations carried out by TEA suggest asbestos levels of 10-^g/litre. This corresponds, m terns of units used by Nicholson et al, to 10 12 grams of asbestos per gyam of injection.
CO-f/ti.'VMA.
U7-T7~Badami
A. L. Rickards
References 1 . Biles, B and Emerson, T. R. Nature 2 1 9 ,9 3 (1968) 2 . Cunningham, H. M. and Pontefract, R. Nature 2 3 2 ,3 3 2 (197"!) 3 . Nicholson, Y7. J., Maggiore, C. J. and Selikoff, I. J. Science
177, 171 (1 9 72) 4 Rickards, A. L. Analytical Chemistry, h h 1872 (1972)
5- Rickards, A. L. Analytical Chemistry, U5, 8 0 9 ,(1973)
n r: fSSV K---
industriell Products
R E S E A R C H & ENGINEERING DIVISION
TABLE__ 1
Chrysotilo Analyses of, British and P.S. Beers
Sample
U.S. Beer British Beer British Beer British Beer British Beer
Chrysotile Content (g/litre) u "T o 5 x 10 8 x 10-8
3 x10'8 4 x 10-8 8 x 10-8
TABLE 2
Chrysotile Analyses of an experimental British Wine after passing through "an asbestos cellulose sheet filter
Sample 100 gal. 9000 gal. 10000 gal 17700 gal, 20000 gal 23000 gal 25000 gal
Chrysotile Content (p/litre).
6 x 10~9 -9
7 x 10 7
1 x 10 8 -9
5 x 10 7 -9
8x10 ; o
/ 2x10'
4 x 10"^ (measured by X-ray technique)
TABLE 3
Chrysotile Analyses of Water and Beer obtained at various stages through a oom.'.ercial brewery
Sample Well head Well head Well head Water Tank Inlet Water Tank Inlet Water Tank Water Tank Fined Beer Rough Filtered Beer Rough Filtered Beer Fine Filtered Beer Fine Filtered Beer
Chrysotile Content ( g/litre)
2 x 10'y -9
4 x 10 7
3 x 10-8
8 x 10"9
2 x 10"8
2 x 10-8 -9
4 x 10 7
3 x 10-8
4
x
-9 10 7
4 X 10'8
6 x 10 c 1 x 10-9
FJ/] A
. Endustna! Products Lid
R E S E A R C H & ENGINEERING DIVISION
TABLE 4
Chrysotile Analyses of Streptomycin Sulphate
Sample
Town Water Post Asbestos Filter Post Membrane Filter
Chrysotile Content (g/litre) (g/ gran)
2x10 3 x 10-8 2 x 10-9
2 x 16 -11
3x10 -1 2
2 x 10
TABLE 5
Chrysotile Analyses of Samples Simulating ths Filtration Processes used in the Manufacture of Human Albumen
The samples were collected after passing through the filters in the
sequence given in the Table.
Sample Post 15 x 40 cm EKS sheets
Chrysotile Content C fi/litre) (g/grai)
_x oo
11 CO NO
o _!x o
1
<6 X
< 6 X 10-12
2 3 X 10"7 3 X -11
3 3 X 3 X 10
Post "Lifeguard" pleated membrane
1. 2.
3.
CO 1 oy--
4X 2 X 10-8
-11 4 X 10 2 X 10"11
NO
o 1
<6 X
< 6 X 10-12
Post 20 Cox Filter Disks 1. 2. 3.
6X 6X 3X
oo 11
CO 1 o
CD CD
6 X 10-11 -11
6 X 10 -11
3 X 10
Post 30" 0 .2 2 jam pore size llillipore pleated membrane
1. 5 X 2. <1 X
oo 11
CD CO
5 X 10-11 <1 X 10-11
i l / i: i/'i, Industria! Products Ltd
R E S E A R C H & ENGINEERING DIVISION
Well w ater. o = Analyses published by Cunningham & P ontefract, Nature 232, 332 1971. x = Analyses published by Nicholson e t al Science, 177 171 1972. A= Analyses by T. B A o f wines, beers & drugs
log g /litre .
fr r/ ` , .
JLLl .- A Industrial Products Ltd
R E S E A R C H & ENGINEERING DIVISION
APPENDIX 1
E lectron Microscopic Estimation Technique
The principle of the electron microscopic analytical technique is that chrysotile asbestos can be uniquely identified in an electron microscope by its characteristic electron diffraction pattern and morphology. Quantitative estimates are obtained by counting the number of fibres visible on an electron micrograph. Samples are prepared for electron microscopic analysis by one of two methods as follows:-
Method A12345 1. 15 ml samples are centrifuged and the residue of suspended solids
collected at the base of the tube.
2 . The residue is washed with filtered deionised water, re-centrifuged and suspended in hydrogen peroxide. A further cycle of washing and centrifuging is followed by suspension in 20/o potassium hydroxide at 5 0 ^ overnight to digest some of the organic material.
3 . After a final wa^ithe residue is suspended in 0.1 to 0 ,5 ml of acetone and centrifuged directly onto an electron microscope grid at the bottom of the collecting tube,
4 . Electron microscopic examination is carried out by first checking the suitability of the specimen followed by a general scan to establish, using selected area electron diffraction, that any fibres present on the samples are chrysotile. Provided that the distribution of the fibres on the grid is uniform, fine areas are chosen, randomly, by spinning the specimen stage controls.
5 . Fibre counting is carried out by totalling the number of fibres present on an enlarged micrograph of the recorded field of view. A convenient way of expressing the numbers of fibres is to count in units of 340ft. diameter by 1 jum length. This unit has been termed "a micron fibril", and has a mass of 2 x 10- ^5g.
(Cont'd)
. JU j^ J L i Industrial Products Ltd
RESEARCH & ENGINEERING DIVISION ' - 2-
6. The amount of asbestos present in a sample is calculated from the total length of chrysotile observed on a grid square, knowing the fraction of the total sample represented by a grid square. The final results are expressed in grams.
Method 'B* 1. One litre of sample is filtered through a 47 mm, 0 .0 5 um mean pore
size, cellulose nitrate membrane filter using either a vacuum or pressure filtration vessel. 2 . Aftex- washing and drying the sample is ashed at 45 0 C for two hours tsiking special precautions to prevent explosive ignition of the membrane^.
3 . The ashed residue is suspended in 1 ml of filtered deionised water using an ultra-sonic bath. The ultra-sonic treatment is continued for a minimum of eight hours to ensure that complete homogenisation of the sample occurs. Also, any chrycotile is released from agglomerated particles, and reduced to micron fibrils.
4 . A 10 ul drop of the suspension is dried onto a carbon coated electron microscope grid for examination.
5 . The specimen is examined in the electron microscope, and if suitable, eight fields of view are recorded at 1000x mag. taking every third grid square across a diameter of the grid.
6. A second sample from the same sample suspension is also examined so that sixteen fields of view are recorded from each sanqjle.
7 . A blank sample is prepared by substituting filtered deionised water for the sample at stage 1 and proceeding through the process as though it were a real sample. Eight fields of view are recorded from the blank sample.
(Cont'd)
J l LLi L '\ industrial Products Ltd
RESEARCH & ENGINEERING DIVISION
-3-
8. The amount of chrysotile present in the original sample is obtained by measuring the total length of chrysotile fibrils present on a grid square and relating that figure to the original sample after subtracting the value obtained from the blank, sample. The results are expressed in grams.
9 . The statistical significance of the results over the blank is determined.
Method 'A' is a technique which can be applied to liquid samples which are difficult to filter. Method 'B' is the preferred method, and has been successfully applied to the analysis of samples of airborne solids collected from the urban atmosphere5 .
/'7 7 7 ' /\
J l iu IIlJl Industrial Products Ltd
R E S E A R C H & ENGINEERING DIVISION
Asbestos In Liquids: /.ddendua
.
--9 The limits quoted aro the detection limits ( 2 x 10 g /'i ) for that particular series of samples. The sample volumes were 0 .5 1 . If the sample volumes had been 5 I > then the detection limit would have been 2 x 10~ g/l. The volume of samples is obviously important in establishing the significance of the analytical results over the laboratory background. A further factor which determines the detection limit is the amount of total solids present in the samples. If the amounts are large, then the E.M. specimens have to be diluted so that any asbestos fibres can bo identified. In this case, the total solids were low and the samples vfere made up to 1 ml after ashing, (samples of urban airborne solids are made up to 100 ml). If the solids contents had been high and we had been forced to dilute the samples to 10 ml then the detection limit would have
Q been 2 x 1 0 g/1.
The centrifuging method, which was used to obtain earlier results, uses 15 ml samples, and deposits the solids directly on to an E.M. grid. However, the final sample analysed on the E.M. grid is not very much greater than that in the ashirig method. For example
Centrifuging gives; 15 ml centrifuged on to 1 E.H. grid
Ashing gives; 1 litre filtered, ashed and transferred to 1 ml One 10 ,nl drop transferred to E.H. grid 105 ul = 1 ml 10ul=10^ml 1 .`. E.M. specimen represents j ^ t h of a litre = 10 ml
Both methods are influenced by the presence of large amounts of total solids and as the ashing method is simpler to apply and is so reliable, it is the preferred method.
A final point in understanding the detection limits of these methods, is that as the contamination from the laboratory fluctuates then the detection limit of the analytical procedure will also vary. A determination of the background is of course carried out for each sample by processing a simultaneous blank sample.
A. L..Rickards