Document Ra9jz85q86Koqe8M43mVBoJjX

J `i 8L 194 Air System Equipment DOLE REFRIGERATING COMPANY 5918 N. Pulaski Road, Chicago 46, 111. 103 PARK AVENUE, NEW YORK 17, N. Y. Canada: Dole Refrigerating Products Limited, 29 Brock St., N., Oakville, Ontario EXPORT DIVISION AND NEW YORK BRANCH--C- C. Ryan 102 Park Avenue New York 17, N. Y. Phone: MUrrybO) 5-0693 NORTH EAST--C. J. Teear 55 Webster Street Saratoga Springs, N. Y. Phase: >785 ATLANTIC CENTRAL--A. J. LANE 625 St. George Read Raleigh, North Carolina Phone: TEnjpJe 2-4923 SOUTH EAST--D- A. DeMore 2518 Pineview Drive Decatur, Georgia Phone: Drake 3-1140 DOLE DISTRICT MANAGERS CHICAGO--H. DeBanftb 5910 N. Pulaski Road Chicago 46, Illinois Phone: IRring 8-3442 NORTH CENTRAL--A. W. Monroe 5910 No. Pulaaki Road Chicago 46, IUinota Phone: IRving 84442 EAST CENTRAL--A. B. Brady 467 Melrose Avenue Columbia jt Ohio Phone: Allberet 8-5255 SOUTH CENTRAL--J. A. WUkeraon 7241 Canterbury Drive St. Louie 21, Uiaaouri Phone: EVergreea 1.1781 SOUTH WEST--R. II. Tafel 10347 Plummer Drive Dallas, Texas Phone: BRoadway 9-8282 PACIPIC SOUTH WEST-H. E. Clay 1437 S. Los Angeles Street Loe Angeles 16, California - phone: Richmond 7-5121 PACIFIC NORTH WEST--R. L. Ballinger 663 Maritime Building Seattle 4, Washington Phone: Main 2-0(85 CANADIAN BRANCH Dole Refrigerating Products Limited 29 Brock Street, North Oakville, Ontario Ray F. Kempt. Manager Gordon L. Timb a, Saks Representative - MANUFACTURERS OF AIR CONDITIONING AND REFRIGERATION EQUIPMENT ICE-CEL ACCUMULATOR UNITS LATENT HEAT ICE STORAGE SYSTEMS FOR AIR CONDITIONING HOLDOVER CAPACITIES AND BUILD-UP TIME FOR STANDARD ICE-CEL UNITS STANDARD LHS-12 LHS-21 ICE-CEL or or UNITS LHS 12* LHS 2lx LHS-H LH^Slx EXTERIOR ICE-CEL TANK ICE-CEL INTERIOR X-UNIT APPLICATION DOLE ICE-CELS are used wherever the air-conditioning load is high for a relatively short period of time, such as in churches, mortuaries, auditoriums, lodge halls, cafe terias, offices, theaters, motels, retail stores. OPERATION The ICE-CEL consists of an assembly of DOLE Vacuum Plates submerged in a tank of water. A condensing unit is connected to and refrigerates the plates, causing ice to build up on their surface. A control is available to stop the condensing unit when the ice has reached any desired thickness. When cooling is to begin, chilled water from the ICE-CEL is pumped through a water coil in the air stream. In passing over ihi coil, the air gives up its heat to the water which is then returned to the ICE-CEL for re-chilling and re-circulation. COMPRESSOR REQUIREMENTS Since the compressor capacity can be spread over the whole day, if necessary, rather j.Kn just for the duration of the actual cooling period, a much smaller condensing unit, together with a correspondingly smaller cooling tower or evaporative condenser, can be used. This eliminates the need for water economisers. Also a compressor used for other purposes and not needed full time can have its idle periods devoted to build ing up ice on the ICE-CEL to be used while the compressor is doing its regular job. As a result, operating costs are kept at a minimum, especially in areas where demand power rates are in effect. The existing power service to the building is usually ade quate. H HP 1 HP 1H HP 2 HP 8 HP 5 HP 7WHP 10 HP IS HP 29 HP NOTE: Add !0 percent if starting water over 60 deg Add 6 percent if starting water between 40 deg-50 deg. 8.T. indicates approximate suction temperstax* at end of ice buildup. Condensing units rnnaikr or larger than shown not recommended. ENGINEERING SERVICE Complete' Engineering Catalog BAE and further technical information avail able on request. Our staff of engineers will help you with your refrigeration problems at no charge or obligation. A DOLE application engineer is located near you to give you prompt service. Write, wire, or phone. Air System Equipment (uingmUag HuUMiy Atlanta 3, Ga. Boston IS, Mass. Buffalo, N. Y. Charlotte 2, N. C. Chicago 6, 111. Cincinnati 2 Ohio Dallas 1, Texas Kansas City 8, Mo. Los Angeles 14, Calif. Memphis 3, Tenn. New Obleans 12, La. Frick Company New York Citt 17 Oblando, Fla. Waynesboro, Penna. Palo Alto, Calif. San Francisco 4, Calif.- (sub-branch) Seattle 1, Wash. (sub-branch) Distributors in Principal Cities Air Conditioning, Refrigerating, Ice Making and Food Freezing Equipment e 195 Philadelphia 4, Penna. Pittsburgh 22. Penna. St. Louis 3, Mo. Washington 5, D. C. Unit Air Conditioners, 3. 5, & 7H hp. AIR CONDITIONING Complete Frick systems, including original designs, in all sixes: also refrigeration for use with equipment supplied by others. Thousands of installations, the world over, attest the value of Frick air conditioning, which has SO years experience behind it. See Frick Bulletin 60S on hospital work; BOS on in stallations and systems; Btt on unit conditioners; and tlfi on Frick air conditioned storages, which are revolutionising the cold storage industry. Estimates cheerfully furnished. Frick "ECLIPSE" Compressors, 2, 3, 4, 6 or 9 cylinders. LOW-PRESSURE REFRIGERATION Bulletin 100. Small commercial units, "ECLIPSE" multi-cylinder com pressors, and larger heavy-duty enclosed compresors, handling refrigerants 12 or 22, provide a complete and efficient line to meet your exact needs. We build unit air conditioners, central systems, plain and finned coils, water coolers, condensers, con trols, valves and fittings: no job too special for Frick Engi- Combined Units AMMONIA REFRIGERATION with "ECLIPSE" Com pressors. Bulletin 100.. Heavy-duty vertical compressors, with 2 or 4 cylinders, in sizes from 2Yt to 1000 tons of refrigeration: handle refrigerant 22 equally well. Useful life of these dependable aver ages 40 years. Highly economical for cooling water on air condi tioning, and for neat-pump service, in addition to regular re frigeration duty. Booster systems, developed by Frick Engineers 30 years ago,-provide power savings at low temperatures. "ECLIPSE" compressors, with 3, 6,.or 9 cylinders, also supplied for ammonia work. Heavy-duty Industrial Compressors, 3 in. by SERVICE 3 in. to 17% in. by 12 in. Bulletins 112, 516 We supply the most complete service, including recommenda & 651. tions, estimates, design, manufacture, installation, test and maintenance. One responsibility, one superior standard. Quota tions cheerfully furnished through Branch Offices and world wide Distributor organizations. The Two Office Buildings of the American National Insurance Co. at Galveston, Texas, are Air Condi tioned Throughout with Frick "ECLIPSE" Com Low Pressure Refrig erating Units, Open Drive or AccessibleHermetic Types. Bulletin 97. The Barnes Hospital---Washington University Medical Center, at St. Louis, has Eleven Frick Air Condition ing Units and 42 Frick Compressors on various Cooling Services. Four of these Frick "ECLIPSE" Compressors were used over 17 years for Air Conditioning the TVA Offices in Knoxville, Tenn. Replaced with Four New "ECLIPSE*' Machines.