Document Ra9jz85q86Koqe8M43mVBoJjX
J
`i
8L
194
Air System Equipment
DOLE REFRIGERATING COMPANY
5918 N. Pulaski Road, Chicago 46, 111.
103 PARK AVENUE, NEW YORK 17, N. Y.
Canada: Dole Refrigerating Products Limited, 29 Brock St., N., Oakville, Ontario
EXPORT DIVISION AND NEW YORK BRANCH--C- C. Ryan
102 Park Avenue New York 17, N. Y. Phone: MUrrybO) 5-0693
NORTH EAST--C. J. Teear 55 Webster Street
Saratoga Springs, N. Y. Phase: >785
ATLANTIC CENTRAL--A. J. LANE 625 St. George Read
Raleigh, North Carolina Phone: TEnjpJe 2-4923
SOUTH EAST--D- A. DeMore 2518 Pineview Drive Decatur, Georgia Phone: Drake 3-1140
DOLE DISTRICT MANAGERS
CHICAGO--H. DeBanftb 5910 N. Pulaski Road Chicago 46, Illinois Phone: IRring 8-3442
NORTH CENTRAL--A. W. Monroe 5910 No. Pulaaki Road Chicago 46, IUinota Phone: IRving 84442
EAST CENTRAL--A. B. Brady 467 Melrose Avenue Columbia jt Ohio
Phone: Allberet 8-5255
SOUTH CENTRAL--J. A. WUkeraon 7241 Canterbury Drive St. Louie 21, Uiaaouri Phone: EVergreea 1.1781
SOUTH WEST--R. II. Tafel
10347 Plummer Drive Dallas, Texas
Phone: BRoadway 9-8282
PACIPIC SOUTH WEST-H. E. Clay 1437 S. Los Angeles Street Loe Angeles 16, California
- phone: Richmond 7-5121
PACIFIC NORTH WEST--R. L. Ballinger 663 Maritime Building Seattle 4, Washington Phone: Main 2-0(85
CANADIAN BRANCH Dole Refrigerating Products Limited
29 Brock Street, North Oakville, Ontario
Ray F. Kempt. Manager Gordon L. Timb a, Saks Representative
-
MANUFACTURERS OF AIR CONDITIONING AND REFRIGERATION EQUIPMENT
ICE-CEL ACCUMULATOR UNITS LATENT HEAT ICE STORAGE SYSTEMS FOR AIR CONDITIONING
HOLDOVER CAPACITIES AND BUILD-UP TIME FOR STANDARD ICE-CEL UNITS
STANDARD LHS-12 LHS-21
ICE-CEL
or
or
UNITS LHS 12* LHS 2lx
LHS-H LH^Slx
EXTERIOR ICE-CEL TANK
ICE-CEL INTERIOR X-UNIT
APPLICATION
DOLE ICE-CELS are used wherever the air-conditioning load is high for a relatively short period of time, such as in churches, mortuaries, auditoriums, lodge halls, cafe terias, offices, theaters, motels, retail stores.
OPERATION
The ICE-CEL consists of an assembly of DOLE Vacuum Plates submerged in a tank of water. A condensing unit is connected to and refrigerates the plates, causing ice to build up on their surface. A control is available to stop the condensing unit when the ice has reached any desired thickness. When cooling is to begin, chilled water from the ICE-CEL is pumped through a water coil in the air stream. In passing over ihi coil, the air gives up its heat to the water which is then returned to the ICE-CEL for re-chilling and re-circulation.
COMPRESSOR REQUIREMENTS
Since the compressor capacity can be spread over the whole day, if necessary, rather j.Kn just for the duration of the actual cooling period, a much smaller condensing unit, together with a correspondingly smaller cooling tower or evaporative condenser, can be used. This eliminates the need for water economisers. Also a compressor used for other purposes and not needed full time can have its idle periods devoted to build ing up ice on the ICE-CEL to be used while the compressor is doing its regular job. As a result, operating costs are kept at a minimum, especially in areas where demand power rates are in effect. The existing power service to the building is usually ade quate.
H HP 1 HP 1H HP 2 HP 8 HP 5 HP 7WHP 10 HP IS HP 29 HP
NOTE: Add !0 percent if starting water over 60 deg Add 6 percent if starting water between 40 deg-50 deg. 8.T. indicates approximate suction temperstax* at end of ice buildup. Condensing units rnnaikr or larger than shown not recommended.
ENGINEERING SERVICE
Complete' Engineering Catalog BAE and further technical information avail able on request. Our staff of engineers will help you with your refrigeration problems at no charge or obligation. A DOLE application engineer is located near you to give you prompt service. Write, wire, or phone.
Air System Equipment (uingmUag HuUMiy
Atlanta 3, Ga. Boston IS, Mass. Buffalo, N. Y. Charlotte 2, N. C.
Chicago 6, 111.
Cincinnati 2 Ohio
Dallas 1, Texas Kansas City 8, Mo. Los Angeles 14, Calif.
Memphis 3, Tenn. New Obleans 12,
La.
Frick Company New York Citt 17 Oblando, Fla.
Waynesboro, Penna.
Palo Alto, Calif. San Francisco 4,
Calif.- (sub-branch)
Seattle 1, Wash.
(sub-branch)
Distributors in
Principal Cities
Air Conditioning, Refrigerating, Ice Making and Food Freezing Equipment
e 195
Philadelphia 4, Penna.
Pittsburgh 22. Penna.
St. Louis 3, Mo. Washington 5,
D. C.
Unit Air Conditioners, 3. 5, & 7H hp.
AIR CONDITIONING
Complete Frick systems, including original designs, in all
sixes: also refrigeration for use with equipment supplied by
others. Thousands of installations, the world over, attest the
value of Frick air conditioning, which has SO years experience
behind it. See Frick Bulletin 60S on hospital work; BOS on in
stallations and systems; Btt on unit conditioners; and tlfi on
Frick air conditioned storages, which are revolutionising the
cold storage industry. Estimates cheerfully furnished.
Frick "ECLIPSE"
Compressors, 2, 3, 4, 6
or 9 cylinders.
LOW-PRESSURE REFRIGERATION
Bulletin 100.
Small commercial units, "ECLIPSE" multi-cylinder com
pressors, and larger heavy-duty enclosed compresors, handling refrigerants 12 or 22, provide a complete and efficient line to
meet your exact needs. We build unit air conditioners, central systems, plain and finned coils, water coolers, condensers, con
trols, valves and fittings: no job too special for Frick Engi-
Combined Units
AMMONIA REFRIGERATION
with "ECLIPSE" Com
pressors. Bulletin 100..
Heavy-duty vertical compressors, with 2 or 4 cylinders, in
sizes from 2Yt to 1000 tons of refrigeration: handle refrigerant
22 equally well. Useful life of these dependable
aver
ages 40 years. Highly economical for cooling water on air condi
tioning, and for neat-pump service, in addition to regular re
frigeration duty. Booster systems, developed by Frick Engineers
30 years ago,-provide power savings at low temperatures.
"ECLIPSE" compressors, with 3, 6,.or 9 cylinders, also supplied
for ammonia work.
Heavy-duty Industrial
Compressors, 3 in. by
SERVICE
3 in. to 17% in. by 12 in. Bulletins 112, 516
We supply the most complete service, including recommenda
& 651.
tions, estimates, design, manufacture, installation, test and
maintenance. One responsibility, one superior standard. Quota
tions cheerfully furnished through Branch Offices and world
wide Distributor organizations.
The Two Office Buildings of the American National Insurance Co. at
Galveston, Texas, are Air Condi tioned Throughout with Frick "ECLIPSE" Com
Low Pressure Refrig
erating Units, Open
Drive or AccessibleHermetic Types.
Bulletin 97.
The Barnes Hospital---Washington University Medical
Center, at St. Louis, has Eleven Frick Air Condition ing Units and 42 Frick Compressors on various Cooling Services.
Four of these Frick "ECLIPSE" Compressors were used
over 17 years for Air Conditioning the TVA Offices in
Knoxville, Tenn. Replaced with Four New "ECLIPSE*' Machines.