Document Ra7mx0kymv5E1dgy6rYrqkx6k

Boilers and Radiators National Radiator Company General Offices: JOHNSTOWN, PA. New York. 47 W. 42nd Street Philadelphia. 121 N. Broad Street Baltimore. 2622 Frisby Street Washington. 1228 H Street Johnstown, Pa. New York New Rochelle Branches Richmond^ 1538 E. Cary Street Pittsburgh. 1402 Arrott Building Cleveland, 6308 Kinsmam Road Cincinnati, Suite 826-827 Union Central Building Plants New Castle, Pa. Trenton, N. J. Warehouses Baltimore Washington Richmond Cleveland Manufacturers National Smokeless, Novus Upright and Sectional, Acme Round, - Radium Gas and Hot Water Supply Boilers, also Aero and Premo Radiators. Seven-Column Patents Applied For AEltp RADIATORS The Aero Radiator was designed by Engineers with more than 30 years experience in radiator manufacture. In the Aero line is represented a real effort to simplify the multiplicity of radiator patterns and heights. Large buildings are now warmed with the more modern, efficient, eco nomical and easily controlled vapor.and vacuum systems. These neces sitate the use of a radiator pattern with top and bottom nipple connection-- the type known as a water section. The demand for the straight steam section, with bottom nipple connection only, is consequently negligible. The Aero Radiator is made in one type only--the top and bottom nipple connected section. It is tapped top and bottom both ends. The top tappings are plugged and the bottom tappings bushed to size required. AU radiators are vented for both steam and hot water. One vent is plugged. Any Aero Radiator can be used for either steam, hot water or vapor. Aero Radiators are made in three patterns--Three, Five and Seven Column. A total of 16 heights composes the entire line. Roughing-in measurements are standard. AU sections measure 2H in. from center to center. The Three-Column pattern is 5J in. wide, the Five-Column pattern 8H in wide and the Seven-Column pattern 12 in. With these widths and standard roughing-in measurements they can be used on any standard specification. Aero radiators are sold at the same price as standard radiation. * 278 National Radiator Company Boilers and Radiators Outlets No. and Size Size Smoke Pipe II National Smokeless Boiler Patented Sectional-View LIST PRICES AND RATING .si J*Size Steam Water Rating Rating Number Grate* Grate Area tq. ft. Com bustion Height Height Cham Water Top Height Includ- ber Area sq. ft. Line Outlet* Inches Inches Triromings Width Boiler Inches Width Length Includ- Includ- Jo* Trim Smoie- Size Base Inches mings hood Inches Inches I 25- 9 2525 4175 9 5 6.11 75-10 2825 4675 10 6 7.27 25-11 3125 5175 11 / 8.43 25-12 3425 5675 12 8 9.59 31- 9 31-10 31-11 31-12 31-13 3625 4050 4475 4900 5325 5975 6675 7375 8075 8775 9 10 11 12 13 5 8.55 6 10.24 7 11.93 8 13.62 9 15.31 36- 9 36-10 36-11 36-12 36-13 36-14 36-15 36-16 5125 8475 5750 9500 6375 10,525 7000 11,550 7625 12,575 8250 13,600 8875 14,625 9500 15,650 9 10 II 12 13 14 15 16 5 11.50 6 13.75 7 16.00 8 16.25 9 20.50 9 20.50 10 22.75 10 22.75 48- 9 9200 15,100 9 5 18.23 48-1(1 10,325 16,950 10 6 21.76 48^11 11,450 18,800 tl. 7 2533 48-12 12,575 20,650 12 8 28.88 48-13 13,700 22,5a 13 9 32.43 48-14 14,825 24,350 14 9 32.43 48-15 15,950 26,2a 15 to 35.98 48-16 17,075 20,050 16 10 35.98 3.48 3.48 3.48 3.48 5.07 5.07 5.07 5.07 5.07 6.75 6.75 6.75 6.75 6.75 9.50 9.50 1205 10.65 10.65 10.65 10.65 10.65 1430 14.20 17.75 49 57% 49 57%. 49 57% 49 57% 52 61 52 61 52 61 52 61 52 61 60% 60% 60% 60'/4 60% 60% 60% 60% 70 70 70 70 70 70 70 70 68 80 68 80 68 80 68 80 68 . 80 68 80 68 80 68 60 65% 65% 65% 65% 71% 71% 71% 71% 71'/, 78% 78% 78% 78% 78% 78% 78% 78y. 89 89 89 89 89 . 89 89 89 36% 36% 36% 36% 50 50 50 SO 50 56 56 56 56 56 56 56 56 67 67 67 67 67 67 67 67 40% 40% 40% 40% 54 54 54 54 54 60 60 60 60 60 60 60 60 71 71 71 71 71 71 71 71 74% 27%, 605/, 3-4' 81% 27%x67% 3-4' 88% 27%x74% 3-4' 95% 27%, 815/, 3-4' 12 12 12 12 79% 88 95% 103 110% 33%, 65% 3-5' 33%z 74 3-5' 33%, 81% 3-5' 33%x 89 3-5' 33%, 96% 3-5' 15 15 15 <5 15 87% 41'%, 73% 3-5' 95% 41%x 81% 3-5' 104% 4I%* 90% 3-5' H7% 4I%* 98% 3-5' 121 4l%xl07 4-5' 129% 41%s1IS% 4-3' 137% 4l%xl23% 4-3' 146% 51%,132% 4-3' 16 16 16 16 16 16 16 16 109% 53%, 89% 3-6' 20 119% 53%z 99% 3-6' 20 130% 53%,110% 4-6' 20 141% 53%xl2l% 4-6' 20 151% 53%,I31% 5-6' 20 162% 53%,142% 3-6' 20 173 53%xl53 5-6' 20 183% 53%*163% 3-6' 20 The National Up-Draft Smokeless Boiler wiU conform to any smoke ordinance. Burning smoke depends upon'the temperature to which the air discharged over the fire is preheated. The National Preheating Air device heats air to in excess of 1000 deg. It is discharged into the smoke and gases as they pass over the Refractory Bridge wall into the Combustion-Chamber. - The National Smokeless Boiler will clear to the No. 1 Smoke Screen in from 10 to 15 seconds and to a clear stack in less than one minute after firing a charge of'green coal. National Smokeless boilers show an average increase of 28 per cent in evaporation on the same fuel charge and consequently are very economical in operation. The volume of preheated air necessary to burn smoke varies with the state of com bustion. The air should be gradually decreased and cut off almost completely during a period of about 20 minutes from the time fuel is charged. Unless this is done the preheated air has a tendency to chiU rather than increase the gas temperatures and Sylph-Oil Air the boiler efficiency and evaporation is decreased.' Regulator The Sylph-Oil Regulator operates the Preheating Air Device automatically and Patents Applied positively can be regulated to close the air intake in any time from one half-a minute For to one hour after fuel is charged. 279