American Society of Heating and Ventilating Engineers Guide, 1929
it is filling. The.air is vented from the system, either'through the vent of the trap to the atmosphere, or where this vent is connected back into the returns the air is vented separately from the trap vent through a thermostatic air trap.
Fig. 11 shows an alternating receiver properly connected for returning the condensate, from a low-pressure heating system to the boiler.. The trap, vent in this case is connected .back into the returns, with a ther mostatic air trap for relieving the air. In this arrangement a check valve op the air vent prevents.the return of air to the system during periods when the pressure in the system is below atmospheric pressure. With this arrangement or with some other special types of non-return air venting apparatus the system may be operated over long periods below atmospheric pressure, thus retaining heat over night or during warmweather with a low fire and nothing more than a vapor in the system. The pressure must eventually be raised above atmosphere, however, at certain times to drive out the air, which eventually leaks into even the tightest system, while operating below atmospheric pressure.
310
CHAPTER XIX
laundry, kitchen and hospital EQUIPMENT AND PIPING SYSTEMS !
Types* Kinds and Sizes of Apparatus Required* Steam and Hot Water Requirements; Electric Requirements, Layouts, Installation Data.
THE requirements of laundry, kitchen' arid hospital equipment vary over wide limits, because, first--there are so rriany different classes of laundries, kitchens and hospitals, second--the Operating technique varies so much. The data and methods herein given are for average operating conditions, but unusual requirements should be given special con sideration.
Piping systems for laundry, kitchen and hospital equipment, generally, should have separate flow and return lines either above or below the equipment but it is better to have the return liries below.
Traps (preferably high-pressure thermostatic) are placed on each coil or unit, and the condensation is trapped into a return main, which is itself vented, and leads by gravity to a vented receiving tank or feed water heater.
The vertical pipe in connections, especially the drop lines from over head mains may be dripped through.separate traps, although these may well be omitted as the fixture coils and traps will care for a limited amount of condensation when the fixture valves are opened up, without damage.
The steam mains should be dripped and drained in about the same manner that would be required in steam piping for any other purpose;
LAUNDRY EQUIPMENT
It is not the purpose to include custom laundries here but rather flat
work laundries for hospitals, institutions, hotels, etc. . :... ..
.:
There is a wide variety of special machines, used mostly in custom or
general laundries, that will not be mentioned herein. Some of these machines are occasionally used in flat work laundries where a limited
amount of other classes of work is to be done but usually, they occupy little floor space, use small amounts of steam, water and electricity and
when their need is felt they can be added without materially effecting the layout of the other and larger machines which require much floor space
and use considerable quantities of steam, water and electricity..
These larger machines are washing; machines; extractors, tumbler dryers, flat work ironers and similar units.