Document RX382eoE385Dp9EnKqN2Lv3B
DATE: SUBJECT: FROM: THRU: TO:
UNITED STATES ENVIRONMENTAL PROTECTION AGENCY REGIONS
77 WEST JACKSON BOULEYARD CIDCAGO, ILLINOIS 60604
DEC o 6 2018
CLEAN AIR ACT INSPECTION REPORT C&D Scrap Metal Recyclers Co., Inc., Houston, Texas
Scott Connolly, Environmental Engineer AECAB (IL/IN)
Nathan Frank, Section Chief AECAB (IL/IN)
File
BASIC INFORMATION
Facility Name: C&D Scrap Metal Recyclers Co., Inc
Facility Location: 6775 Bingle Road, Houston, Texas 77092
Date of Inspection: November 8, 2018
EPA Inspectors: 1. Scott Connolly, Environmental Engineer 2. Natalie Topinka, Environmental Scientist
Other Attendees 1. Chris Garcia, Operations Manager, C&D Scrap Metal 2. Dennis Laviage, President & CEO, C&D Scrap Metal 3. Brian Shipp, Trader & Manager, C&D Scrap Metal
Contact Email Address: dl@cdscrapmetal.com
Purpose of Inspection: To determine compliance with the Clean Air Act
Facility Type: Metal shredding and recycling yard
Regulations Central to Inspection: 40 C.F.R. Part 82, Subpart F: Recycling and Emissions Reduction
Arrival Time: 3:23 pm Departure Time: 4:24 pm
Inspection Type: f;gJ Unannounced Inspection D Announced Inspection
OPENING CONFERENCE
f;gJ Credentials Presented f;gJ CBI warning to facility provided
The following information was obtained verbally from Dennis Laviage unless otherwise noted.
Process Description: The C&D Scrap Metal facility is a scrapyard that accepts various post-consumer and industrial ferrous and non-ferrous metals. The facility accepts white goods, appliances, cars and refrigeration components. The facility sorts light iron, aluminum, copper scrap, and other metals into piles of like material. Metals are bailed in ferrous and non-ferrous bailers and loaded onto trucks for transport to a metal shredding or non-ferrous metal recycling facility.
Staff Interview: Facility staff stated that it requires appliances to be drained of refrigerants prior to acceptance appliances. The scale ticket, that all suppliers sign contains a statement certifying that refrigerants have been recovered from appliances prior to arrival at the facility. The facility owns refrigeration recovery equipment but does not and has never used it to recover refrigerants from appliances or vehicles. The facility accepts sealed units and copper tubing separately and stated that appliances make up a relatively small percent of its business.
TOUR INFORMATION
EPA toured the facility: Yes
Data Collected and Observations: Compressors formerly part ofhome refrigeration units were observed in the sealed units bin. Ferrous metal is bailed when it arrives at the facility and bailed metal is stacked into piles.
Photos and/or Videos: were taken during the inspection. A photo log is contained in Appendix A.
Field Measurements: were not taken during this inspection.
CLOSING CONFERENCE
Requested documents: 1. Scale Ticket (one copy obtained)
Page 2 of 4
Compliance Assistance: Facility staff were provided a copy of 40 C.F.R. Part 82, Subpart F and were informed that the verification statement on the scale ticket needs to have the, name and address of the person recovering the refrigerant and the date that it was recovered.
Concerns: The facility verification statement does not contain all ofthe required information.
SIGNATURES
Report Author: ~~~-~~~~~-- Date: ({ /z 1; II <l,
Section Chief: --""-.,...._..:;,:,::.L_ _:.......,:::....____,_.....__ _ Date:
/Z/4d'f?
I /
I
Page 3 of4
Facility Name: C&D Scrap Metal Recyclers Co., Inc Facility Location: 6775 Bingle Road, Houston, Texas Date of Inspection: November 8, 2018
APPENDICES AND ATTACHMENTS
1. Appendix A: Digital Image Log
Page 4 of 4
Facility Name: C&D Scrap Metal Recyclers Co., Inc
Facility Location: 6775 Bingle Road, Houston, Texas
Date of Inspection: November 8, 2018
APPENDIX A: DIGITAL IMAGE LOG
1. Photographer Name: Natalie Topinka
3. Company/Facility Name:
C&D Scrap Metal Recyclers Co., Inc
5. Number of Images:
3
2. Date of Inspection:
November 8, 2018
4. Street Address, City, State:
6775 Bingle Road, Houston, Texas
6. Archival Record Location:
https://usepamy.sharepoint.com/:f:/g/personal/connolly_scott_epa_gov/Evc on2zOSU1BgFfYkqabaYcBMVj5RtkHWLvk:MUB58APBSg? e=wu.Ox2N
Image Number
1
File Name PB070025.JPG
2
PB070026.JPG
3
PB070027.JPG
Date and Time 11/7/2018 17:26 11/7/2018 17:48 11/7/2018 17:52
Latitude and Lomritude 29.86397, 95.487748
. 29.863889, 95.4875
29.863889, 95.4875
Description of Image
Entrance to the C&D facility office and warehouse Refrigerator compressor in sealed units bin C&D ferrous metal scrap pile, bailer and bailed metal pile
Appendices Page 1 of 1