Document RRpxZZj7Ng239mgBewKMdkzk

Monsanto from .name a location, a. E. Leisy, W. G. Krummrich Plant DATE October 13, 1975 :W. B. Papageorge - BIND REFERENCE VERSAR VISIT TO Mr. R. W . Flint`S The technical people from Versar requested information on types and control of waste effluents, both air and water from the incinerator and the operating departments. They were also interested in the control equipment operating and technical techniques. The following is a summary of information discussed. 1. Incinerator Cost of cons truction $900,000 plus site preparation and utilities Operating expenses Operating capacity Permit exists Safeguards to insure Limits of analysis Air and sewer losses High costs result of $600,000 in 1976 est. 6,000,000 pounds plus complete combustion 10 ppb No detectable amount and 0 high temperature to burn PCB to 0.4 ///day completely. They visited the incine rat ion a r ea an d asked to see tank truck, tank car, and dr urn unloa ding a reas an d we r e in teres in how we controlled th e s umps and ac tually f o 11 owe d lines (without help) to confi rm sumps wer e pumped th ro u gh s ample station. There was a n ega tive commen t about a re a a ro und drum emptying station, A block ske t c h on b 1 ac kb o ar d indi- cated flow of material for them - 2. Department Entire area curbed with all liquid flow through sampling and measuring station. HC1 scrubbed and sent to another area for PCB removal. Flow varied from 150-300 gpm depending upon operations. FeCl3 and CaOH solids to residue to incineration. Heat transfer units air cooled except for 1016 system which had water unit but run under vacuum system to prevent water contamination. Ejector tail pipes directed to sumped area. Air sampling results negative -- no PCB found. Average PCB losses from department at 0.5 pound per day or less to sewer. dSNN 330404 STLCOPCB4077048 Mr. R. W. Flint VERSAR VISIT Page 2 10/13/75 WGK 2. Department (Cont'd) ' The subject of direct contact--process water--PCB came up. Visitors considered ejectors were possible source. No others existed. The question was asked as to people tolerance to product. Information was given that there had been no case where any person had adverse reaction to the products during any time with Aroclors. They were aware that Aroclors 1221, 1242, 1254, and 1016 were now being produced, and had some knowledge as to what happened to HC1 off-gas. 3. Tank Car Loading Area sumped under cars. Procedures existed for insuring integrity of car before leaving Monsanto. Prior knowledge existed that customer owned (F.O.B. WGK). Imparted our reactions to calls for help in case of spill,etc. 4. Subjects that were referred to W.B.P. Technical papers on carboh/foam effluent studies. Soil migration studies. Bi0 - they brought up Who else burns PCB Background loss Solids disposal prior to incinerator use Sauget Treatment Plant Incinerator permit, and permit application Process info re temperatures, pressures, compositions, operating techniques and Discussion subjects were limited generally to hardware for control of effluents. 5. Information not brought up and not discussed. Personnel monitoring Current disposal of solids such as Types/locations of landfills Individual stream PCB losses Protective equipment Losses of PCB from WGK plant. Disposal of returned empty drums rags /tm attachment: Copies of written information supplied to visitors per W.B.P. STLCOPCB4077049